POWER NOTES O <br />15. <br />NEW SERVICE DISCONNECTS AND METERS FOR SERVICE DISTRIBUTION. SEE POWER RISER DIAGRAM, SHEET E301, FOR ADDITIONAL <br />INFORMATION. <br />1. <br />PROVIDE (1) CAT 5 CABLE TO OFFICE COMPUTER AND (2) CAT 3 CABLES TO TELEPHONE BOARD. TERMINATIONS AT EACH END BY SAL <br />VENDOR. VERIFY ROUTING AND REQUIRED LENGTHS PRIOR TO ROUGH -IN. - <br />16. <br />PROVIDE 60A/3P NEMA 1, NON -FUSED DISCONNECT AND CONNECTION TO OWNER FURNISHED BALER. VERIFY REQUIREMENTS AND <br />REQUIRED TERMINATIONS AND PROVIDE ACCORDINGLY. <br />2. <br />2-COMPARTMENT POWER POLE FOR POWER AND COMMUNICATION CONDUCTORS. VERIFY REQUIRED CAPACITY, STYLE AND LENGTH <br />WITH OWNER AND PROVIDE ACCORDINGLY. <br />17. <br />OUTLET BOX AND CONNECTION TO OWNER FURNISHED HAND DRYER. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. MAKE ALL <br />REQUIRED TERMINATIONS. <br />3. <br />PROVIDE (2) 1" CONDUITS WITH PULL STRING FOR CCTV. EACH CONDUIT SHALL TERMINATE IN A FLUSH MOUNTED OUTLET BOX IN <br />WALL AND ABOVE CEILING IN AN ACCESSIBLE LOCATION. VERIFY OUTLET BOX LOCATIONS PRIOR TO ROUGH -IN. <br />18. <br />EXISTING ROOFTOP UNIT TO REMAIN AS -IS. FIELD VERIFY TO MAINTAIN ALL EXISTING ELECTRICAL CONNECTIONS. <br />4. <br />PROVIDE 4'X8' UL LISTED FIRE RETARDANT PLYWOOD TELEPHONE BACKBOARD WITH TOP AT T AFF. PROVIDE #6 BARE CU GROUND <br />19. <br />PROVIDE 60A/3P NEMA 3R, NON -FUSED, PULL TYPE DISCONNECT AND CONNECTION TO OWNER FURNISHED UNI-LIFT. VERIFY ACTUAL <br />BONDED TO NEAREST BUILDING STEEL AND TERMINATED TO CU GROUND BAR (ILSCO #D167-10 OR EQUIVALENT). LOCATE QUAD <br />REQUIREMENTS AND LOCATION. <br />RECEPTACLE ON BOTTOM RIGHT CORNER OF BOARD. EXTEND (1) 2" C TO MAIN TELEPHONE DEMARK ON EXTERIOR OF BUILDING. <br />20, <br />MAIN SWITCHBOARD AND BRANCH PANELBOARDS, IN THIS ROOM, ARE EXISTING TO REMAIN AND BE REUSED FOR NEW <br />5. <br />PROVIDE FLUSH MOUNTED OUTLET BOX AT 6'-4" A.F.F. WITH (1) 1" CONDUIT (EMPTY W/PULLWIRE) TO ABOVE CEILING FOR MUSIC AND <br />CONSTRUCTION. REFER TO RISER DIAGRAM AND PANEL SCHEDULES FOR NEW CIRCUITING AND/OR REQUIRED MODIFICATIONS AND <br />INTERCOM TERMINATE IN AN ACCESSIBLE LOCATION WITH INSULATING BUSHING <br />PROVIDE ACCORDINGLY. <br />6. <br />JUNCTION BOX AND CONNECTION TO AIR CURTAIN. VERIFY LOCATION AND TERMINATIONS AND PROVIDE ACCORDINGLY. <br />21. <br />EXISTING EXHAUST FAN TO REMAIN. FIELD VERIFY EXISTING CIRCUIT AND CONTROL AND MAINTAIN ACCORDINGLY. <br />7. <br />DUPLEX RECEPTACLE IN CEILING FOR CUSTOMER AWARENESS MONITOR. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. PROVIDE ALL <br />22. <br />PROVIDE (1) 2" CONDUIT (EMPTY W/PULLWIRE) FROM TOP OF TELEPHONE BOARD TO MAIN TELEPHONE SERVICE DEMARK BOARD <br />NECESSARY SUPPORTS. <br />LOCATED IN FRONT MEZZANINE OF ADJACENT SPACE. VERIFY ROUTING, LENGTH, AND TERMINATIONS PRIOR TO ROUGH -IN. <br />8. <br />COIL AND CAP CONDUCTORS IN JUNCTION BOX ABOVE CEILING FOR FUTURE CHECK -STAND. <br />GENERAL NOTES <br />9. <br />OUTLET BOX AND CONNECTION TO OWNER FURNISHED AUTOMATIC DOOR. VERIFY LOCATION AND TERMINATIONS AND PROVIDE <br />1. <br />ALL 120V CIRCUIT LENGTHS GREATER THAN 100 FT SHALL BE INCREASED TO #10 AWG AND TO # 8 AWG WHEN GREATER THAN 160 FT. <br />ACCORDINGLY. <br />INCREASE CONDUIT FOR 40% FILL. <br />10. <br />RECEPTACLE FOR PALLET JACK BATTERY CHARGER. VERIFY LOCATION WITH OWNER PRIOR TO ROUGH -IN. <br />2. <br />REFER TO HVAC WIRING SCHEDULE FOR CIRCUITING REQUIREMENTS OF SAME. <br />11. <br />PROVIDE 208V/3P/30A RECEPTACLE FOR MEAT GRINDER. VERIFY NEMA CONFIGURATION OF ACTUAL EQUIPMENT AND PROVIDE <br />3. <br />WORKING CLEARANCE SHALL BE AFFORDED TO ALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC 110.26. <br />CORRESPONDING RECEPTACLE. <br />N <br />4. <br />ALL 15 & 20A, 120V RECEPTACLES WITHIN 6FT OF A SINK SHALL BE GFCI PROTECTED. <br />12. <br />PROVIDE WEATHERPROOF RECEPTACLE FOR EVAPORATOR CONDENSATE HEAT TRACE. VERIFY REQUIRED LOCATION. <br />w <br />13. <br />PROVIDE DOORBELL (EDWARDS #340-4G5), PUSHBUTTON (EDWARDS #1786C-B) AND TRANSFORMER (EDWARDS #592). LOCATE BELL PER <br />3 <br />OWNER'S DIRECTION. <br />14. <br />EXISTING METER AND SECONDARY FEEDER TO BE REMOVED. REFER TO POWER RISER DIAGRAM, SHEET E301, FOR ADDITIONAL <br />q <br />INFORMATION. <br />0 <br />POWER PLAN <br />DUCT DETECTOR NOTE <br />120 VOLT DUCT DETECTOR WITH REMOTE TEST SWITCH. <br />DUCT MOUNTED SMOKE DETECTORS ARE FURNISHED, <br />INSTALLED, AND LOW VOLTAGE WIRED BY MECHANICAL <br />CONTRACTOR. 120 VOLT POWER TO THE DETECTOR SHALL BE <br />PROVIDED AND WIRED BY THE ELECTRICAL CONTRACTOR. <br />S = SUPPLY SIDE R = RETURN SIDE <br />HVAC & PLUMBING EQ. WIRING SCHEDULE <br />UNIT <br />NUMBER <br />DISCONNEC <br />I BRANCH CIRCUIT <br />SWITCH <br />FUSES <br />CONDUIT <br />WIRE <br />PANEL <br />RTU-1 <br />N3R/60/3/240V <br />45 <br />1" <br />3#6 & 1#10 E.G. <br />H-29,31,33 <br />EWH-50 <br />N1/60/2/240V <br />N.F. <br />3/4" <br />2 #8 & 1 #10 EG <br />H-21,23 <br />ARTISTIC SOLUTIONS HALO, INC. <br />(CONSULTANTS) <br />ASHLEIGH ADAMOSKY <br />6822 22ND AVE. N. <br />SUITE 335 <br />ST. PETERSBURG, FL 33710 <br />813-495-0917 <br />ASHB0769HOTMAIL.COM <br />p <br />o � <br />w a 0 <br />us <br />w <br />z o <br />722 ' <br />STATE OF <br />��r4rtio�t►eeeee <br />w <br />z <br />w <br />i— <br />C) <br />o <br />a <br />ozIr <br />J0 <br />� <br />J <br />_ <br />o <br />1 <br />O <br />_ <br />LL <br />Q <br />U) <br />w <br />z <br />Lu <br />T_ <br /><=0 <br />o <br />0.. <br />o <br />Q� <br />w <br />� <br />a <br />Cn <br />N <br />w <br />z <br />O <br />SAVE - -LOT <br />RENOVATION <br />PROJECTADDRESS: <br />RESS; <br />TOWNVIEW SQUARE aHOPRIr, �`�FNTER <br />7:320 GALL BLVD, <br />7PPL{°fRHIL.LS, FLORIDA :3.35< 1, <br />PA SCO COUNTY <br />SUPERVALU <br />COMPANY <br />CLIENT ADDRESS: <br />100 CORPORATE OF-FIC,E DR <br />EARTH CITY, 1 ISSOURI <br />DATE <br />DESCRIP7IC<N <br />-0 -10 <br />OWNER REVIEW' <br />POWER PLAN <br />ASH <br />PROJECT #: 710-009 <br />E201 <br />09-02-10 <br />a <br />N-r it <br />