Laserfiche WebLink
MAIN ELECTRIC ROOM <br />BUILDING WALL <br />FRONT OFFICE <br />COMPRESSOR <br />RACK ON ROOF <br />400U <br />125IG <br />COORDINATEWITH POWER COMPANY1200 ............................. _._...._.._................................... . ...... _.__...._<.._..__........_............_............. ._.... _....... _........... _.-................ .._...... _............ ..:.._..... _ ..__. _..__..._.._...__. ._.__..._._._.............__...__.....__._... _....... ....._........__..._............. _........... _.._ -._...W....-__.............__.... <br />TO REMOVE EXISTING C.T.'S INSIDE <br />TRANSFORMER AND ASSOCIATED <br />UTILITY METER <br />EXISTING UTILITY Co. I t (N) (N) (E) (E) (E) (E) (E) (.E) (E) (E) (E) (N) <br />PAD MOUNTED I f ( 1200A 800A I c I.'t�NEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL I PANEL <br />��ihrI7C.NI3t?ARD � �. � �._ ,. .. <br />TRANSFORMER 1O I._... ,:_..! • 3 3 • 3 INIS .3' 'El 'L' K N. CD' 13C'.' 'AB' 'EC! 'CR' <br />1200A 800A 3000 A 125A <br />N3R N3R I�IALI� Sid I'CII MLO <br />g I I.20/208V I 120/208V <br />208 .1.20Y <br />,.: /� C.T. C.T. 8 3IrIt, 4el <br />L�T 3ph, 4w <br />I IL..1`1'i CAB. CAB. TRANSFORMER <br />FEEDER SCHEDULE <br />SYMBOL <br />COPPER <br />NOTES <br />CONDUCTORS (THWN/THHN) <br />CONDUIT SIZE <br />PER SET <br />SETS <br />PHASE & NEUTRAL <br />GROUND <br />1200S <br />4 <br />4 #350 KCMIL <br />-- <br />3-1/2" <br />EXISTING CONDUITS TO BE REUSED. <br />800S <br />3 <br />4 #300 KCMIL <br />- <br />3" <br />1200 <br />4 <br />4 #350 KCMIL <br />1 #3/0 <br />3" <br />125IG <br />1 <br />4 #1 <br />2 #6 <br />1-1/2" <br />1 #6 E.G. & 1 #6 I.G. <br />40OU <br />1 <br />4 #500 KCMIL <br />1 #3 <br />3-1/2" <br />RATED FOR 380A MAXIMUM LOAD <br />ABBREVIATIONS: <br />S = SERVICE <br />T = UPSIZED EG DUE TO TAPPED CONDUCTORS PER NEC 250.122(G) <br />P = PHASE ONLY (SINGLE PHASE WITH NEUTRAL OR THREE PHASE WITH NO NEUTRAL) <br />U = UNDER -RATED (WIRE RATED LESS THAN THE FULL AMPACITY RATING OF THE BREAKER) <br />IG = ADDITIONAL GROUND CONDUCTOR FOR ISOLATED GROUND <br />E= EXISTING <br />FAULT CURRENT CALCULATION <br />UTILITY/ORIGIN VOLTS: <br />208 <br />TRANSFORMER KVA <br />1500 <br />UTILITY/ORIGIN FAULT: <br />85635 <br />FEEDER <br />ORIGIN <br />DESTINATION <br />ORIGIN <br />DESTINATION <br />LENGTH <br />WIRE <br />SIZE <br />SETS <br />X/R RATIO <br />FAULT <br />X/R RATIO <br />FAULT <br />UTILITY XFMR <br />800A MAIN <br />20 <br />CU <br />600 <br />2 <br />12.00 <br />85635 <br />5.65 <br />69457 <br />UTILITY XFMR <br />1200A MAIN <br />15 <br />CU <br />350 <br />4 <br />12.00 <br />85635 <br />6.50 <br />78390 <br />1200A MAIN <br />PANEL MDP <br />5 <br />CU <br />350 <br />4 <br />6.50 <br />78390 <br />5.71 <br />76168 <br />PANEL MDP <br />IPANEL CR <br />250 <br />1 CU <br />r--17-1 <br />1 <br />5.71 <br />76168 <br />1 0.31 <br />1 3526 <br />GENERAL NOTES: <br />1. PANEL AIC RATING MUST BE GREATER THAN OR EQUAL TO DESTINATION FAULT VALUE IN TABLE ABOVE. <br />2. THE FAULT CURRENT STUDY IS BASED ON THE TRANSFORMER SIZE INDICATED ABOVE. <br />3. THE ELECTRICAL CONTRACTOR SHALL CONFIRM UTILITY TRANSFORMER AVAILABLE FAULT CURRENT PRIOR TO ORDERING GEAR. <br />4. THE ELECTRICAL CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF FAULT CURRENT IS DIFFERENT THAN INDICATED ABOVE. <br />5. SERIES RATING OF CIRCUIT BREAKERS IS PERMITTED IN ALL LOCATIONS WHERE PERMITTED BY LOCAL JURISDICTION. <br />6. WHERE SERIES RATING IS UTILIZED, PROVIDE MANUFACTURERS TESTING DOCUMENTATION FOR ALL BREAKERS WITH SUBMITTALS. <br />7. FEEDER LENGTHS INDICATED IN THIS TABLE ARE NOT TO BE USED FOR BIDDING PURPOSES. CONTRACTOR SHALL DETERMINE FEEDER LENGTH <br />FOR BIDDING PURPOSES AND NOTIFY ENGINEER IF THEIR PROPOSED ROUTING IS MORE THAN 10% DIFFERENT THAN SHOWN. <br />JNO SCALE <br />RISER NOTES O <br />1. COORDINATE WITH PROGRESS ENERGY FLORIDA (PEF) REPRESENTATIVE FOR <br />DISCONNECTION AND REMOVAL OF EXISTING SERVICE CONDUCTORS AND <br />INSTALLATION OF NEW SERVICE FEEDERS AND CONDUITS INTO SECONDARY <br />COMPARTMENT OF TRANSFORMER. <br />2. PROVIDE NEW NEMA 3R METER SOCKET PER PET SPECIFICATIONS. EXTEND #4 CU <br />GROUND TO GROUNDING ELECTRODE SYSTEM. <br />3. C.T. CABINET PER PET SPECIFICATIONS, CT'S BY PER <br />4. PROVIDE NEW 1200 AMP SERVICE FEEDER IN EXISTING 3-1/2" CONDUITS. <br />5. CONTRACTOR SHALL LEAVE A MINIMUM 6'-0" SLACK CONDUCTOR FOR <br />TERMINATION BY POWER COMPANY. <br />6. PROVIDE NEW SECONDARY SURGE ARRESTOR,120/208V-3 PHASE WITH UL OWHX <br />LISTING. <br />7. PROVIDE NEW SERVICE GROUND. <br />8. TERMINATE NEW SERVICE CONDUCTORS AT LINE SIDE OF DISCONNECT. LOAD <br />SIDE CONTINUATION TO BE AT TIME OF FUTURE TENANT BUILD -OUT UNDER <br />SEPARATE CONTRACT AND COVER. <br />RISER GENERAL NOTES <br />1. VOLTAGE DROP IN ACCORDANCE WITH FLORIDA BUILDING CODE 13-413.1AB.1 & <br />13-413.1AB.2 HAS BEEN TAKEN INTO ACCOUNT FOR THIS PROJECT. <br />Lu <br />z <br />Lu <br />F_ <br />CU <br />CD <br />O <br />z <br />J <br />J <br />°- <br />_J <br />0 <br />o <br />J <br />0 <br />LL <br />vJ <br />' <br />W <br />z <br />Lu <br />O� <br />.Q <br />= <br />O <br />U <br />> <br />::) <br />0 <br />Qa <br />C/) <br />N <br />IL <br />W <br />z <br />0 <br />A E -A- LT <br />TENANT BUILD411"J"ll- <br />ENO' T <br />_ RO�gplq f[_("g�lti�t�;l"q ESS: <br />E���f4°F'a'�'ii€;:'.Ys4 Qi3A#"k ... (ky �i,°s '.. ..t `+,"i� CENTER <br />7320 GAI ,,,I.,. BLVD. <br />PA CO COLJNTY <br />SUPERVALU <br />COMPANY <br />10 (1,00RII > F F I C E D R, <br />EARTH 0I Y, tvIISOURI <br />DATE <br />DESCRIPTION <br />0 -02-10 <br />OWNIER FTEVIEW <br />