<br />ASME T&P RELIEF
<br />II
<br />VALVE: DWV DRAIN
<br />III
<br />DISCONNECT SWITCH -1� FULL SIZE ROUTED
<br />BY ELECTRICAL. r _1 TO MSB
<br />II
<br />SUBCONTRACTOR
<br />THERMAL EXPANSION TANK:
<br />VACUUM BREAKER: �I�
<br />AMTROL "THERM-X-TROL" ST-5
<br />LAVATORY
<br />36 WATTS OR EQUAL i
<br />OR HAND SINK
<br />CHECKVALVE I
<br />HEAT TRAP
<br />GATE VALV
<br />i
<br />COLD WATER -�
<br />I
<br />I
<br />J.R. SMITH
<br />MOUNT SOV AT i y
<br />--
<br />HOT WATER
<br />2698
<br />#
<br />5'0" AFF MAX. i
<br />DOWN IN WALL
<br />rIL-----_
<br />III
<br />_
<br />1/2" TYPE "L"
<br />DIELECTRIC UNIONS
<br />COPPER PRIMER,
<br />SAFEWASTE TO TRAP
<br />I
<br />FLOOR DRAIN
<br />SERVICE DRAIN VALVE
<br />WATER
<br />HEATER
<br />FLOOR
<br />' •
<br />DRAIN: SCHEDULE
<br />40 PVC, ROUTED
<br />TO MSB I
<br />_
<br />SAFETY PAN: 24
<br />GAGE GALVANIZED
<br />- - - - - -
<br />SHEET METAL, 1-1/2"
<br />MOUNTED ON 2
<br />- -
<br />DEEP, SOLDERED
<br />COURSES OF.CMU
<br />LIQUIDTIGHT
<br />WATER HEATER DETAIL
<br />FLOOR DRAIN TRAP PRIMER
<br />DETAIL
<br />ON CMU SUPPORT
<br />14
<br />AIR ADMITTANCE
<br />VALVE
<br />3"
<br />FCO
<br />PLUMBING FIXTURE SCHEDULE
<br />ROUGH -IN
<br />MARK
<br />FIXTURE, MODEL #, DESCRIPTION
<br />WASTE
<br />VENT
<br />CW
<br />HW
<br />P-1
<br />HAND SINK, EAGLE FOODSERVICE EQUIPMENT, MODEL HAS-10-FDP.
<br />1-1/2"
<br />2"
<br />1/2"
<br />1/2"
<br />PROVIDED BY TENANT, INSTALLED BY CONTRACTOR. EQUIPPED WITH.FAUCET,
<br />1-1/4" CP P-TRAP, CP STOPS, SUPPLIES.
<br />P-2
<br />TRIPLE COMPARTMENT SINK, EAGLE FOOD SERVICE EQUIPMENT, MODEL
<br />3"
<br />2"
<br />1/2"
<br />1/2"
<br />414-16-3-18. PROVIDED BY TENANT, INSTALLED BY CONTRACTOR. PROVIDE.
<br />T&S MODEL B-231 FAUCET WITH 12"-NOZZLE, PROFLOW BASKET STRAINER
<br />IK1431SS, CP STOPS, KEY OPERATED TRAPS AND FLOOR MOUNTED LEGS.
<br />P-3
<br />DRINKING FOUNTAIN, DUAL LEVEL, HANDICAPPED
<br />1-1/2"
<br />2"
<br />1/2"
<br />HALSEY TAYLOR HRFSEBP, STAINLESS STEEL, 1-1/2" 20 GAUGE CP P-TRAP,
<br />LESS CO, STOP AND SUPPLIES. MOUNT LOWER BOWL NOZZLE AT 30" A.F.F
<br />FOR ADA.
<br />P-4
<br />WATER CLOSET, HANDICAPPED
<br />3"
<br />2"
<br />1/2"
<br />ELJER PRESERVER #091-4985 WHITE ELONGATED, 1.6 GALLON FLUSH, TANK
<br />TYPE WATER CLOSET, ELJER #124-2105 WHITE SEAT WITH NO COVER, CP
<br />STOP AND SUPPLY.
<br />P-5
<br />LAVATORY, WALL HUNG, HANDICAPPED
<br />1-1/2"
<br />2"
<br />1/2"
<br />1/2"
<br />ELJER #051-1308 WITH ELJER #805-1065 WALL CARRIER, WITH DELTA
<br />#520-MPU FAUCET AND SINGLE LEVER HANDLE, 1-1/4" CP P-TRAP, CP
<br />STOPS, SUPPLIES. PROVIDE TRU-BRO #102-EZ INSULATION KIT.'
<br />P-6
<br />INSIDE HOSE BIBB
<br />SEE
<br />PLAN
<br />CHICAGO FAUCET #952 WITH VACUUM BREAKER AND INLET FLANGED LOCK
<br />SHIELD CAP 293-6. WITH REMOVABLE HANDLE AND CHROME ESCUTCHEON.
<br />MSB
<br />MOP SERVICE BASIN EQUAL TO:
<br />3"
<br />2"
<br />3/4"
<br />3/4"
<br />ZURN 1996-36 36"x24" MOLDED STONE MOP SERVICE BASIN WITH ZURN 843M1
<br />FAUCET AND PAIL HANGER. VERIFY WITH SAVE -A -LOT SPECIFICATIONS AND
<br />CONSTRUCTION MANAGER.
<br />EWH-50
<br />ELECTRIC WATER HEATER
<br />3/4"
<br />3/4"
<br />A.O." SMITH DEL-50
<br />R-16 FOAM INSULATED, GLASS -LINED 50 GALLON TANK, THREE (3) YEAR
<br />WARRANTY WATER HEATER. 32" HIGH x 26" DIAMETER, 6.0 kW ® 208/1
<br />PHASE ELECTRIC HEATER. U.L. LISTED AND ASHRAE 90.1-1999 APPROVED.
<br />FD-1
<br />FLOOR DRAIN
<br />3"
<br />2"
<br />1/2"
<br />ZURN Z415-6B-P
<br />6" FLOOR DRAIN WITH TRAP -PRIMER CONNECTION AND TYPE "B" STRAINER.
<br />FS-1
<br />FLOOR SINK
<br />3"
<br />2"
<br />1/2"
<br />ZURN Z1900
<br />12"x12" FLOOR SINK, 6" SUMP DEPTH WITH TRAP -PRIMER CONNECTION AND
<br />SEDIMENT BUCKET.
<br />GI
<br />GREASE INTERCEPTOR
<br />3"
<br />2"
<br />ZURN GT2700-50
<br />IN -FLOOR GREASE INTERCEPTOR WITH INLET FLOW CONTROL. 50 GPM FLOW
<br />WITH 100 LB GREASE CAPACITY. VENT AS REQUIRED.
<br />3" HD
<br />NOTES
<br />1.
<br />APPROVED MANUFACTURERS OF FIXTURES ARE ZURN, AMERICAN STANDARD, ELJER AND KOHLER.
<br />3"
<br />HD
<br />2.
<br />3.
<br />4.
<br />APPROVED MANUFACTURERS OF DRAINS AND CLEANOUTS ARE
<br />ALL SUPPLIES SHALL BE PROVIDED WITH CP BRASS ANGLE
<br />ALL EXPOSED TRAPS AND WASTE ARMS SHALL BE CP BRASS
<br />J.R. SMITH, ZURN AND WADE.
<br />STOPS BY EASTMAN OR BRASSCRAFT.
<br />BY MCGUIRE OR EQUAL.
<br />V
<br />V
<br />5.
<br />PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS EQUAL TO
<br />JR SMITH.
<br />. lom=
<br />rVA"!
<br />IF LVIVIUIIVV VI-IVLI\P•%L IVV 1 LJ
<br />1. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES. THIS SHALL INCLUDE THE
<br />2007 FLORIDA BUILDING CODE AND THE 2007 FLORIDA PLUMBING CODE, WITH 2O09 AMENDMENTS.
<br />2. REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING. INSTALLATION TO INCLUDE ALL PLUMBING FOR
<br />COMPLETE SYSTEMS DEPICTED ON THE PLANS.
<br />3. COORDINATE WITH OTHER TRADES TO PREVENT CONFLICTS WITH HVAC DUCTS, ELECTRICAL LIGHTING
<br />AND STRUCTURAL ELEMENTS.
<br />4. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL FIXTURES SHOWN ON THE PLUMBING
<br />FIXTURE SCHEDULE. VERIFY MOUNTING HEIGHT AND CONNECTION SIZES OF ALL PLUMBING
<br />FIXTURES PRIOR TO INSTALLATION.
<br />5. ALL WORK, BOTH MATERIAL AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR
<br />FROM ACCEPTANCE BY THE OWNER.
<br />WATER PIPING
<br />1. THE WATER PIPING SHALL BE TYPE "K" COPPER BELOW GRADE, WITH VINYL SLEEVE FOR
<br />ANTI -CORROSION, AND TYPE "L" ABOVE GROUND WITH WROUGHT COPPER FITTINGS (ASTM
<br />B16.22-89) AND SOLDER JOINTS.
<br />2. THE WATER SERVICE TO THE SPACE IS EXISTING TO REMAIN.
<br />3. THE MAIN BACKFLOW PREVENTER IS EXISTING TO REMAIN.
<br />4. THE SITE WATER METER IS EXISTING TO REMAIN.
<br />5. SUPPORT ALL PIPING WITH PIPE HANGERS EQUAL TO GRINNEL.
<br />6. PROVIDE EACH FIXTURE WITH A SHUT-OFF SUPPLY STOPS. EXPOSED STOPS AND SUPPLY PIPING
<br />SHALL BE CHROME PLATED, WITH CHROME ESCUTCHEON PLATE AND SET SCREW. STOPS SHALL BE 8"
<br />AFF FOR WATER CLOSETS AND 16" AFF FOR LAVATORIES.
<br />7. PROVIDE UNIONS FOR ALL CONNECTIONS TO SERVICEABLE EQUIPMENT. UNIONS SHALL BE
<br />DIELECTRIC WHERE DISSIMILAR METALS ARE CONNECTED.
<br />8. INSULATE ALL HOT WATER PIPING WITH I" ARMAFLEX OR in FIBERGLASS EQUAL TO MANVILLE
<br />MICRO-LOK AP-T. VAPOR SEAL ALL BUTT JOINTS.
<br />9. PROVIDE WATER HAMMER ARRESTORS, EQUAL TO JR SMITH 5000 SERIES, IN ACCORDANCE WITH PDI
<br />STANDARD WH-201. FIELD FABRICATED SHOCK ABSORBERS ARE NOT ACCEPTABLE.
<br />10. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE.
<br />11. STERILIZE ALL WATER PIPING IN ACCORDANCE WITH HEALTH DEPARTMENT REGULATIONS.
<br />12. TEST ALL WATER PIPING AT 100 PSIG FOR SIX HOURS OR AS REQUIRED BY THE JURISDICTION.
<br />13. PROVIDE SHUT OFF VALVES FOR ALL EXTERIOR HOSE BIBS AND WALL HYDRANTS.
<br />14. PROVIDE SERVICE VALVES AT EACH BRANCH SUPPLY LINE, AS DEPICTED ON THE PLAN. ALL
<br />VALVES, CHECK STOPS, ETC. SHALL BE RATED FOR 125 LB SERVICE. VALVES SHALL BE BALL OR
<br />GATE TYPE, GLOBE VALVES ARE NOT ACCEPTABLE. VALVES SHALL BE INSTALLED IN AN
<br />ACCESSIBLE LOCATION FOR SERVICING AND OPERATION.
<br />SANITARY, WASTE AND VENT PIPING
<br />1. SANITARY WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC DWV (ASTM-2665) WITH SOLVENT
<br />WELDED JOINTS.
<br />2. SLOPE OF SANITARY AND WASTE PIPING SHALL BE UNIFORM, WITH A MINIMUM OF in PER FOOT FOR
<br />2" AND A MINIMUM OF In PER FOOT FOR LARGER PIPING.
<br />3. EXPOSED WASTE DRAINS IN RESTROOMS SHALL BE CHROME PLATED BRASS TUBING WITH MATCHING
<br />CHROME ESCUTCHEON PLATE.
<br />4. PROVIDE INTERIOR AND EXTERIOR CLEANOUTS AS REQUIRED BY CODE.
<br />5. FURNISH 4 LB LEAD OR 8 OZ COPPER VENT FLASHING FOR INSTALLATION BY THE GENERAL
<br />CONTRACTOR FOR ALL VENTS THROUGH ROOF. VERIFY TYPE OF ROOFING PRIOR TO INSTALLATION.
<br />6. TEST SANITARY, WASTE AND VENT PIPING USING A 10 FOOT WATER COLUMN FOR 2 HOURS OR AS
<br />REQUIRED BY THE JURISDICTION.
<br />WATER DEMAND (SILVER
<br />RING)
<br />CW
<br />HW
<br />TOTAL
<br />CITY
<br />TOTAL
<br />EACH
<br />EACH
<br />EACH
<br />EACH
<br />ALL
<br />P-1 HAND SINK
<br />1.5
<br />1.5
<br />2.0
<br />2
<br />4.0
<br />P-2 TRIPLE COMPARTMENT SINK
<br />2.0
<br />2.0
<br />3.0
<br />2
<br />6.0
<br />P-3 DRINKING FOUNTAIN
<br />0.5
<br />0.0
<br />0.5
<br />1
<br />0.5
<br />P-4 WATER CLOSET
<br />5.0
<br />0.0
<br />5.0
<br />2
<br />10.0
<br />P-5 LAVATORY
<br />1.5
<br />1.5
<br />2.0
<br />2
<br />4.0
<br />MSB MOP SERVICE BASIN
<br />2.0
<br />2.0
<br />3.0
<br />1
<br />3.0
<br />TOTAL WSFU 27.5
<br />TOTAL GPM = 22 PIPE SIZE = 1"
<br />GREASE INTERCEPTOR SIZING
<br />TRIPLE COMPARTMENT SINK (19"x18"x13" DEEP)
<br />(13,338 CU. IN.) / (231 CU. IN. / GAL) = 57.74 GALLONS
<br />57.74 GALLONS x 0.75 CAPACITY = 43.31 GALLONS
<br />USING A 1 MINUTE DRAIN PERIOD = 43.31 GPM REQUIRED. „
<br />50 GPM CAPACITY PROVIDED.
<br />r
<br />Q
<br />Y
<br />a
<br />cc
<br />'n
<br />z
<br />o
<br />�
<br />1 J
<br />w
<br />!
<br />Li
<br />z
<br />w
<br />w
<br />z
<br />w
<br />U
<br />Z
<br />O� o
<br />I J
<br />a J o
<br />Jp = LL
<br />UQ =>- Z)
<br />> LIJ o
<br />�W N a
<br />z
<br />0
<br />SAVE -A -LOT
<br />TENANT BUILD -OUT
<br />RENOVATION
<br />PROJECT ADDRESS:
<br />TOWNVIEW SQUARE SHOPPING CENTER
<br />7320 GALL BLVD.
<br />ZEPHYRHILLS, FLORIDA 33541
<br />PASCO COUNTY
<br />SUPERVALU
<br />COMPANY
<br />CLIENT ADDRESS:
<br />100 CORPORATE OFFICE DR.
<br />EARTH CITY, MISSOURI
<br />DATE DESCRIPTION
<br />09-02-10 OWNER REVIEW
<br />09-08-10 PERMIT DRAWINGS
<br />PLUMBING
<br />DETAILS
<br />SEEDS Engineering, Inc. ASH
<br />PROJECT #: 710-009
<br />27730 Santa Anita Blvd. p: (813) 902-2515
<br />Wesley Chapel, FL 33544 f: (813) 902-2516
<br />jmakar@seedseng.com P 10 1
<br />Florida Certificate of Authorization No. 28278 09-09-10