My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7320 Gall Blvd (7)
Zephyrhills
>
Building Department
>
Building Plans
>
7320 Gall Blvd (7)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 8:08:36 PM
Creation date
1/21/2025 3:42:09 PM
Metadata
Fields
Template:
Building Plans
Street #
7320
Location
Gall Blvd
Contractor
Gerardi Construction
Building Plans - Permit #
11103
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />)VE <br />NG <br />BY <br />■ <br />n FIRE PROTECTION PLAN <br />SPRINKLER DRAWING NOTES <br />1. <br />PROVIDE WET PIPE SPRINKLER SYSTEM TO PROVIDE COMPLETE COVERAGE THROUGHOUT <br />9. <br />PROVIDE ADDITIONAL DRAINS REQUIRED TO COMPLY WITH NFPA 13. <br />18. <br />CONTRACTOR TO CONDUCT FLOW TEST AND HYDRAULIC CALCULATIONS TO VERIFY THAT SYSTEM <br />BUILDING AND DRY PIPE SYSTEM UNDER CANOPY AS REQUIRED BY LOCAL AUTHORITY TO <br />COMPLIES WITH THE REQUIREMENTS OF NFPA 13 FOR ORDINARY HAZARD GROUP 2. <br />COMPLY WITH 2O02 EDITION OF NFPA 13, 2007 FLORIDA FIRE PREVENTION CODE, <br />10. <br />FLUSH AND TEST SYSTEM IN ACCORDANCE WITH NFPA 13. <br />SAVE -A -LOT CRITERIA, AND AUTHORITY HAVING JURISDICTION. <br />19. <br />SPRINKLER HEADS SHALL BE ORDINARY HAZARD AND ORDINARY DEGREE TEMPERATURE RATED <br />11. <br />CONTRACTOR SHALL PREPARE SHOP DRAWINGS BASED UPON THESE PLANS AND OBTAIN <br />UNLESS PROXIMITY TO A HEAT SOURCE REQUIRES A HIGHER RATING PER NFPA-13. <br />2. <br />CONTACT SAVE -A -LOT REPRESENTATIVE FOR INFORMATION ON SPRINKLER SYSTEM <br />APPROVAL OF AUTHORITY HAVING JURISDICTION, PRIOR TO CONSTRUCTION. IF THE DESIGN <br />REQUIREMENTS. <br />DEPICTED ON THESE DRAWINGS EXCEEDS THE MINIMUM REQUIREMENTS OF NFPA 13 OR THE <br />21. <br />AT FINISHED SPACES SPRINKLER HEADS ARE TO BE LOCATED IN MODULAR TILES 12 INCHES <br />AHJ, COMPLY WITH THESE DRAWINGS UNLESS WRITTEN APPROVAL IS REQUESTED OF AND <br />FROM CEILING GRID AND CENTERED UNIFORMLY AND SYMMETRICALLY IN SPACES WITH HARD <br />3. <br />SPRINKLER PIPE SHALL BE PER NFPA STANDARDS. BRANCHLINES TO BE ALLIED X-L PIPE <br />OBTAINED FROM THE ENGINEER OF RECORD PRIOR TO BIDDING. IF APPROVAL IS NOT <br />CEILINGS. <br />WITH THREADED FITTINGS, SCHEDULE 40 PIPE WITH THREADED FITTINGS OR SCHEDULE 10 <br />REQUESTED AND THE DEVIATION IS INCORPORATED INTO THE SHOP DRAWINGS, APPROVAL OF <br />PIPE WITH WELDED OUTLETS AND GROOVED JOINTS. CROSS MAINS TO BE ALLIED X-L PIPE <br />SHOP DRAWINGS DUE TO THE FAILURE OF THE ENGINEER OF RECORD TO DETECT THE <br />22. <br />PROVIDE FLOW SWITCHES ON RISERS AND TAMPER SWITCHES ON ALL CONTROL VALVES, <br />WITH THREADED FITTINGS OR 'THIN WALL' (PER NFPA) WITH WELDED OR GROOVED OUTLETS <br />DEVIATION WILL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO MEET THIS <br />INCLUDING THE PIV (FIELD VERIFY). PROVIDE CONDUIT FROM PIV (AS APPLICABLE) TO <br />AND JOINED WITH GROOVED FITTINGS. ARMOVERS AND DROPS SHALL BE SCHEDULE 40. ALL <br />REQUIREMENT. IN THAT CASE, THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL MAKE ANY <br />FIRE CONTROL PANEL IN BUILDING FOR PIV TAMPER SWITCH WIRE. <br />PIPE SHALL HAVE A CORROSION RESISTANCE RATIO OF 1.0 OR GREATER AND BE UL LISTED <br />MODIFICATIONS NECESSARY TO COMPLY WITH THIS REQUIREMENT. <br />AND FMG APPROVED. FITTINGS SHALL BE OF TYPE APPROVED AND LISTED FOR THE TYPE OF <br />23. <br />THE RISER PROVIDING SERVICE COVERAGE TO THE TENANT SPACE IS TO BE SEPARATE AND <br />PIPE SELECTED. DRY PIPE SYSTEM PIPING SHALL BE GALVANIZED. <br />12. <br />IF CONFLICTS EXIST OR ALLOCATED SPACE IS INADEQUATE, CONTRACTOR TO NOTIFY <br />INDEPENDENT OF OTHER AREAS OF COVERAGE. <br />ARCHITECT PRIOR TO BIDDING AND OBTAIN WRITTEN INSTRUCTIONS FOR RESOLUTION. <br />4. <br />ALL DEVICES TO BE UL LISTED OR FM APPROVED. <br />13. <br />PIPE AND FITTINGS SHALL BE TYPE SPECIFICALLY IN NFPA 13. SCHEDULE 5 PIPE WITH <br />5. <br />ALL MATERIAL, METHODS AND DESIGN SHALL BE PER 2002 EDITION OF NFPA 13. <br />PRESS ON FITTING AND NON-METALLIC PIPE SYSTEMS ARE NOT ALLOWED. <br />6. PROVIDE ALL HANGERS INCLUDING TRAPEZE HANGERS AS REQUIRED TO COMPLY WITH NFPA 13. 14. SEAL ALL OPENINGS THROUGH CEILINGS AND PARTITIONS TO RE-ESTABLISH THE FIRE <br />RATING OF THAT CEILING OR PARTITION. SEE ARCHITECTURAL DRAWINGS FOR RATINGS. <br />7., PROVIDE SPARE SPRINKLERS AND SPRINKLER WRENCH IN METAL CABINET PER NFPA 13. <br />15. ALL PIPING IN AREAS WITH DROPPED CEILINGS SHALL BE CONCEALED ABOVE THE CEILING. <br />8. COORDINATE EXACT LOCATIONS OF SPRINKLERS AND PIPING WITH CEILING, ELECTRICAL, <br />MECHANICAL AND STRUCTURAL ELEMENTS OF BUILDING. MAKE MODIFICATION WITHOUT 16. RAISE OR RELOCATE ANY PIPE REQUIRED TO PERFORM ALL WORK WITHIN STORE, <br />ADDITIONAL COST TO THE OWNER. <br />17 CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND PAY ALL RELATED FEES. <br />1 <br />N <br />LEGEND <br />CHROME RECESSED PENDENT SPRINKLER <br />O <br />BRASS UPRIGHT SPRINKLER <br />O <br />DRY PENDENT SPRINKLER <br />0 <br />BRASS SIDEWALL SPRINKLER <br />D <br />L"! <br />DESIGN CRITERIA <br />1. RETAIL SPACE AND STORAGE ROOM ARE ORDINARY <br />HAZARD GROUP 2. a.MAXIMUM SPRINKLER COVERAGE IS <br />130 SQ FT. <br />b.DENSITY IS 0.20 GPM / SQ FT. <br />c.HYDRAULIC DESIGN AREA IS 1500 SQ FT. <br />d.HOSE STREAM ALLOWANCE IS 250 GPM. <br />NOTE: THIS PRECLUDES ANY HIGH PILED STORAGE AS <br />DEFINED BY NFPA 13. <br />2. RESTROOMS, OFFICES, AND BREAKROOMS ARE <br />LIGHT HAZARD. a.MAXIMUM SPRINKLER COVERAGE IS <br />225 SQ FT. <br />b.DENSITY IS 0.10 GPM / SQ FT. <br />c.HYDRAULIC DESIGN AREA IS 1500 SQ FT. <br />d.HOSE STREAM ALLOWANCE IS 100 GPM. <br />3. SHOPPING CART STORAGE AREA <br />a.MAXIMUM SPRINKLER COVERAGE IS 130 SQ FT. <br />b.DENSITY IS 0.15 GPM / SQ FT. <br />c.HYDRAULIC DESIGN AREA IS 1500 SQ FT. <br />d.HOSE STREAM ALLOWANCE IS 250 GPM. <br />ry <br />w <br />z <br />w <br />U <br />OZ_ <br />J <br />Ja <br />J <br />o <br />o <br />LLI <br />>. <br />Z) <br />LLJQ <br />T. <br />> <br />a� <br />w <br />q <br />a <br />u) <br />W <br />N <br />a <br />z <br />0 <br />SAVE -A -LOT <br />TENANT BUILD -OUT <br />RENOVATION <br />PROJECT ADDRESS: <br />TOWNVIEW SQUARE SHOPPING CENTER <br />7320 GALL BLVD. <br />ZEPHYRHILLS, FLORIDA 33541 <br />PASCO COUNTY <br />SUPERVALU <br />COMPANY <br />CLIENT ADDRESS; <br />100 CORPORATE OFFICE DR. <br />EARTH CITY, MISSOURI <br />DATE DESCRIPTION <br />09-02-10 OWNER REVIEW <br />09-08-10 PERMIT DRAWINGS <br />FIRE <br />PROTECTION <br />PLAN <br />ASH <br />P.E. 45847 PROJECT #: 710-009 <br />Charles A. Davis, P.E. <br />4004 Woodacre Lane (813) 968-3270 FP1 00 <br />Tampa, Florida 33624 fax: (813) 960-9724 09-09-10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.