My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7326 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7326 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 2:51:35 PM
Creation date
1/21/2025 3:42:25 PM
Metadata
Fields
Template:
Building Plans
Street #
7326
Location
Gall Blvd
Contractor
North River Builders
Building Plans - Permit #
11495
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BASIC OPERATION - GENERAL NOTES <br />1. ENSURE ALL ELECTRICAL CONNECTIONS ARE TIGHT AND CORROSION <br />FREE. <br />2. ALL SECONDARY DUCT RUNS TO BE STANDARD MANUFACTURED <br />ROUND DUCT WRAPPED WITH 1 " VINYL COATED INSULATION. <br />3. INSTALL 45' SIDE TAKEOFF (STO) WITH VOLUME AIR CONTROL DAMPERS <br />AT ALL ROUND BRANCH TAKE OFFS, AS SHOWN ON DRAWING. <br />4. USE OF FLEX DUCTS FOR FINAL CONNECTION TO CEILING SUPPLY <br />DIFFUSERS IS ALLOWED WITH THE LENGTH OF FLEX DUCT LIMITED <br />TO 4'-0" MAX. DO NOT USE FOR RETURN DUCT. <br />5. THE CONTRACTOR SHALL PROVIDE A COMPLETE AND OPERATING <br />MECHANICAL SYSTEM, INCLUDING ALL INCIDENTAL ITEMS AND <br />CONNECTIONS NECESSARY FOR PROPER OPERATION ARE <br />CUSTOMARILY INCLUDED. EVEN THOUGH EACH AND EVERY ITEM <br />MAY NOT BE INDICATED. CONTROL DAMPERS ARE LOCATED. <br />6. THE DRAWINGS INDICATE THE GENERAL LAYOUT REQUIREMENTS <br />FOR EQUIPMENT, FIXTURES, PIPING, DUCTWORK, ETC. FINAL LAYOUT <br />SHALL BE GOVERNED BY ACTUAL FIELD CONDITIONS WITH ALL <br />MEASUREMENTS VERIFIED AT THE SITE. <br />7. THE RECOMMENDED QUANTITY OF VENTILATION AIR FOR THIS <br />INSTALLATION IS 10,183 IN ACCORDANCE WITH ASHRAE 62-89. <br />8. CONTRACTOR SHALL VERIFY THE NUMBER OF SMOKE DETECTORS <br />AND/OR FIRESTATS WITH LOCAL AUTHORITIES. <br />9. FINAL LOCATION OF THERMOSTATS IS TO BE COORDINATED WITH <br />NOVAR. CONTACT MR. CARROLL FITZGERALD AT 1-800-348-1235, <br />ext 5638 FOR MORE INFORMATION. <br />10. MOUNTING HEIGHT OF THE THERMOSTAT IN THE WOMEN'S FITTING <br />ROOMS IS TO BE 84" A.F.F. <br />I <br />$ - REOSTAT SWITCH PROVIDED WITH FAN, CONTACT <br />NATIONAL. ACCOUNTS FOR INFORMATION. <br />IECHANICAL CONTRACTOR TO FURNISH AND INSTALL <br />DAPTACURBS WHEN REPLACEMENT OF EXISTING <br />0OFTOP EQUIPMENT IS REQUIRED. CONTACT NATIONA, <br />ICCOUNTS FOR INFORMATION. <br />PROCESSING ROOM SHALL RECEIVE FLEXIBLE DUCT. <br />MFG. DUCT SOX, FABRIC OPTION POLYTEX, MODEL <br />OPTION HIGH THROW. NATIONAL ACCOUNT CONTACT: <br />DENNIS WILSON 815-219-9920 dwllson0ductsox com <br />CUT51DE AIR CAL CUL AT I ON5 <br />(BASED ON ASHRAE STANDARD 622001) <br />OUTSIDE AIR REQUIRED: <br />SALES AREAS: <br />21586/1000 x 15= 323 OCCUPANTS <br />323 OCCUPANTS x1(o CFM= 5180CFM <br />MERCHANDISE HANDLING, RECEIVING t STORAGE AREAS: <br />3286 SF. x .06 CFM/SF- = 191 CFM <br />RESTROOMS <br />5 WATER CLOSETS AND 1 URINAL x 15 CFM= 450 CFM <br />TOTAL OUTSIDE AIR CFM REQUIRED: 5821 CFM <br />OUTSIDE AIR PROVIDED <br />RTU-1 - 440 CPl <br />RTU-2 = 352 CFM <br />RTU-3 = 1100 CFM <br />RTU-4 - 1100 CFM <br />RTU-5 - 440 CFM <br />RTU-6 = 1100 CFM <br />RTU-1 = 1100 CFM <br />RTU-8 - 264 CFM <br />RTU-9 = 264 CFM <br />TOTAL O.A. PROVIDED = 6160 CFM <br />MECHANICAL 5"T M5OL5 <br />AND A55RE V I AT I ON5 LEGEND <br />AFF. <br />ABOVE FINISHED FLOOR <br />-G—G- <br />GAS PIPING OF SIZE NOTED <br />AMB. <br />AMBIENT TEMPERATURE <br />-D D- <br />CONDENSATE DRAIN PIPING OF SIZE NOTED <br />BHP <br />BRAKE HORSEPOWER <br />BTUH <br />BRITISH THERMAL UNITS PER HOUR <br />I <br />UNION <br />CLA <br />CO2 <br />CENTERLINE <br />CARBON DIOXIDE <br />�p <br />DUCT MOUNTED SMOKE DETECTOR <br />CONTR. <br />CFM <br />CONTRACTOR <br />CUBIC FEET PER MINUTE <br />SUPPLY AIR DIFFUSER <br />DB <br />DRY BULB TEMPERATURE <br />DIA• <br />DIAMETER <br />Z <br />RETURN OR EXHAUST GRILLE <br />DN• <br />DOWN <br />EA. <br />EXHAUST AIR <br />F <br />VOLUME DAMPER (VD) <br />EF <br />EXHAUST FAN <br />THERMOSTAT <br />ESP <br />EXTERNAL STATIC PRESSURE <br />EXH. <br />EXHAUST <br />® <br />REMOTE TEMPERATURE SENSOR <br />FIN. FL. <br />FLA <br />HNISHED FLOOR <br />FULL LOAD AMPERES <br />G02 <br />CARBON DIOXIDE SENSOR <br />HP <br />HORSEPOWER <br />0 <br />PIPE RISER <br />MBH <br />ONE THOUSAND (IWO) BTUH <br />C- <br />PIPE DROP <br />MFR <br />N.I.C. <br />MANUFACTURER <br />NOT IN CONTRACT <br />SHUT OFF VALVE <br />NOM. <br />NOMINAL <br />N <br />CHECK VALVE <br />N•T,S. <br />NOT TO SCALE <br />O•A. <br />OUTSIDE AIR <br />'�- <br />OAI <br />OUTSIDE AIR INTAKE <br />1 <br />DUCT RISE OR DROP (R=RISE, D=DROP) <br />OBD <br />OPPOSED BLADE DAMPER <br />Rp <br />R.A. <br />RETURN AIR <br />RPM <br />RTU <br />REVOLUTIONS PER MINUTE <br />ROOF TOP UNIT <br />DISCHARGE OR SUPPLY AIR DUCT <br />SA <br />S.F. <br />SUPPLY AIR <br />SQUARE FEET <br />RETURN OR EXHAUST AIR DUCT <br />S.P. <br />TSP <br />STATIC PRESSURE <br />TOTAL STATIC PRESSURE <br />OUTSIDE AIR SUPPLY DUCT <br />TYP. <br />UH <br />TYPICAL <br />UNIT HEATER <br />POINT OF CONNECTION/ELEVATION/INVERT <br />WB <br />WET BULB TEMPERATURE <br />W.G. <br />WATER COLUMN <br />1�i C�4AN I CAL <E%t'EED NOTES <br />O MECHANICAL CONTRACTOR SHALL PROVIDE TEMPORARY HEAT/COOL THERMOSTATS TO BE USED FOR <br />RTU CONTROLS DURING INSTALLATION, TESTING AND BALANCING. LOCATE T'STATS AT SAME <br />LOCATION THAT THE FUTURE NOVAR TEMPERATURE SENSOR WILL BE INSTALLED . MOUNT T'STATS AT <br />60' AFF EXCEPT IN FITTING ROOMS WHERE THEY ARE TO BE MOUNTED AT 84' AFF. <br />O2 RTU IS LOCATED DIRECTL" ABOVE TYPE 'H' CONCENTRIC SUPPLY AND RETURN AIR DIFFUSER/GRILL . <br />CONTRACTOR SHALL EXTEND DUCT OPENINGS ON BACK SIDE OF DIFFUSER/GRILL UP TO RTU ABOVE <br />AND TRANSITION TO SAME SIZE AS UNIT SUPPLY AND RETURN AIR OPENINGS. ALL CONDITIONS AND <br />LOCATIONS MUST BE VERIFIED PRIOR TO FABRICATING ANY DUCTWORK. <br />O TYPE 'H' CONCENTRIC SUPPLY AND RETURN AIR DIFFUSER HAS TWO DUCT OPENINGS ON TOP FOR <br />32'x18' SUPPLY AND RETURN AIR DUCT CONNECTIONS. CONTRACTOR SHALL EXTEND THESE TWO <br />OPENINGS A MINIMUM OF 30' ABOVE THE BACK OF THE DIFFUSER/GRILL TO ALLOW FOR SIDE <br />CONNECTION OF 26',0 SUPPLY AND RETURN AIR DUCT . <br />O4 TYPE 'C' SIDEWALL GRILL/REGISTER MOUNTED AT 10'-0' AFF TO BOTTOM. PROVIDE INSULATED <br />GALVANIZED STEEL BOOT THROUGH WALL PENETRATION AND PROVIDE SQUARE TO ROUND TRANSITION <br />. SEE AIR DEVICE SCHEDULE FOR ADDITIONAL INFORMATION. REGISTER TO BE PROVIDED WITH <br />GASKET AND OPPOSED BLADE DAMPER <br />O ROOF MOUNTED EXHAUST FAN PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR <br />F'ROVIDE WITH FACTORY ROOF CURB AND SPEED CONTROLLER. EXTEND 8'0 EXHAUST DUCT UP FROM <br />TYPE GI EXHAUST INTAKE GRILL TO FAN INLET • VERIFY FAN CONNECTION REQUIREMENTS IN FIELD . FAN <br />TO BE CONTROLLED BY NOVAR BMS SYSTEM.COORD[NATE INSTALLATION WITH LANDLORDS ROOFING <br />CONTRACTOR SEE EXHAUST FAN SCHEDULE FOR ADDITIONAL INFORMATION. <br />O ELECTRIC UNIT HEATER TO BE PROVIDE AND INSTALLED AS SCHEDULED BY THE MECHANICAL <br />CONTRACTOR, BLOWER MOTOR CONNECTION BY ELECTRICAL CONTRACTOR SEE DETAIL ON DRAWING <br />SHEET M2. CONTRACTOR SHALL PROVIDE TEMPORARY T'STAT CONTROLLED FOR USE UNTIL BMS <br />SYSTEM IS INSTALLED AND ACTIVATED. SEE UNIT HEATER SCHEDULE ON DRAWING SHEET M2. <br />07 RECEIVING / PROCESSING ROOMN AIR DISTRIBUTION SHALL BE VIA FLEXIBLE FABRIC DUCT AS <br />MANUFACTURED BY 'DUCT SOX. CONTACT DENNIS WILSON AT 815-219-9920 FOR PURCHAISING AND <br />ADDITIONAL INFORMATION. <br />O DROP DOWN INSULATED SUPPLY AIR PLENUM FRAM ABOVE AND CAP BOTTOM FOR SIDE CONNECTION <br />OF BRANCH DUCTS. PROVIDE SQUARE TO ROUND TRANSITION ON ALL SUPPLY AIR TAKE -OFFS FROM <br />SUPPLY PLENUM. VERIFY SUPPLY AIR CONNECTION SIZE PRIOR TO FABRICATING ANY DUCTWORK <br />O SMOKE DETECTOR IN RETURN AIR STREAM FOR AUTO SHUT DOWN OF BLOWER SYSTEM TO BE <br />PROVIDED AND INSTALLED BY EQUIPMENT MANUFACTURER. SMOKE DETECTOR TO BE INTERLOCKED <br />WITH BMS SYSTEM AFTER INSTALLATION. SMOKE DETECTOR SHALL BE MONITORED BY LANDLORDS <br />FIRE ALARM COMPANY. <br />10 DROP DOWN RETURN AIR DUCT FROM UNIT ABOVE , SAME SIZE AS UNIT OPENING AND TRANSITIONAL AS <br />INDICATED. MOUNT TYPE 'D' RETURN AIR GRILL IN BOTTOM OF HORIZONTAL SECTION OF DUCT. THIS <br />DUCTWORK AND RETURN AIR GRILL WILL BE VISABLE FROM BELOW. INSTALL IN A WORKMAN LIKE <br />MANNER AND PAINT AS DIRECTED BY OWNERS FIELD REPRESENTATIVE. SEE AIR DEVICE SCHEULE <br />FOR ADDITIONAL INFORMATION. <br />11 ROOF MOUNTED HVAC UNIT WITH ELECTRIC HEAT AND FACTORY ROOF CURB TO BE PROVIDE BY THE <br />MECHANICAL CONTRACTOR AS SCHEDULED. CONTRACTOR MUST FAMILIARIZE HIMSELF WITH THE <br />OWNERS HVAC CONTROL REQUIREMENTS AND ENSURE THAT EACH RTU 18 PREPAIRED TO RECEIVE THE <br />ELECTRONIC THERMOSTAT MODUAL PROVIDED BY NOVAR SEE NOVAR SYSTEM INSTALLATION <br />DRAWINGS AND TJ MAXX SPECIFICATION 1180 FOR ADDITIONAL INFORMATION. <br />12 DROP DOWN INSULATED RETURN AIR PLENUM FROM ABOVE AND CAP BOTTOM FOR SIDE CONNECTION <br />OF BRANCH DUCTS. VERIFY RETURN AIR CONNECTION SIZE PRIOR TO FABRICATING ANY DUCTWORK <br />13 ROOF MOUNTED EXHAUST FAN PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR <br />PROVIDE WITH FACTORY ROOF CURB AND SPEED CONTROLLER. EXTEND 10'0 EXHAUST DUCT UP <br />FROM TYPE GI EXHAUST INTAKE GRILL TO FAN INLET. VERIFY FAN CONNECTION REQUIREMENTS IN <br />FIELD. FAN TO BE CONTROLLED BY NOVAR BMS SYSTEM.COORD[NATE INSTALLATION WITH <br />LANDLORDS ROOFING CONTRACTOR SEE EXHAUST FAN SCHEDULE FOR ADDITIONAL INFORMATION. <br />14 TYPE 'H' CONCENTRIC SUPPLY AND RETURN AIR DIFFUSER/GRILL TO BE PROVIDED AND INSTALLED <br />BY THE MECHANICAL CONTRACTOR SEE AIR DEVICE SCHEDULE FOR ADDITIONAL INFORMATION. <br />15 ROOF MOUNTED EXHAUST FAN PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR <br />PROVIDE WITH FACTORY ROOF CURB AND SPEED CONTROLLER. DROP DOWN 16'xi6"O EXHAUST <br />PLENUM FROM ABOVE AND CAP BOTTOM FOR SIDE CONNECTION OF EXHAUST DUCTS FROM TYPE 'G' <br />EXHAUST INTAKE GRILLS AS INDICATED. PROVIDE VOLUME CAON DAMPERS AT EACH BRANCH <br />CONNECTION. VERIFY FAN CONNECTION REQUIREMENTS IN FIELD . FAN TO BE CONTROLLED BY NOVAR <br />BMS SYSTEM. COORDINATE INSTALLATION WITH LANDLORDS ROOFING CONTRACTOR SEE EXHAUST FAN <br />SCHEDULE FOR ADDITIONAL INFORMATION. <br />16 PROVIDE INSULATED GALVANIZED STEEL PLENUM ON BACK OF TYPE 48'x24' 'G' RETURN AIR GRILL TO <br />ALLOW FOR CONNECTION OF 26'O RETURN AIR DUCT. <br />L <br />L = 1 /4 W, 4" MIN. <br />PROVIDE NYLON I 1 <br />BEARING ON <br />DAMPER SHAFT <br />PROVIDE MANUAL <br />BUTTERFLY DAMPER <br />IN BRANCH TAKE- <br />OFF WHERE SHOWN <br />ON PLAN <br />PROVIDE STAND- / <br />OFF INSULATION <br />BRACKET ON <br />INSULATED DUCTS <br />90? <br />\ SEE PLANS FOR <br />RUNOUT SIZES <br />450 SPIN -IN FITTINGS <br />L W/ SCOOPS ARE <br />NOT ACCEPTABLE <br />FLEXMASTER MODEL STO <br />aEBR4NGH DUCT F I tT INCH DETA1 L6 <br />SCALE: NO SCALE <br />atR4NSI T f ON AND D f FFU:ER CONNECt I ON <br />3 SCALE: NO SCALE <br />HANGING <br />MOLDED RETURN A <br />TRANSITION <br />RETURN GRILLE <br />INSULATED METAL <br />DUCT <br />DIFFUSER BOX <br />FLUSH DIFFUSER <br />1 <br />aCONCENTRIC plF:;:UfDr=;R DET4 f L <br />SCALE: NO SCALE <br />r'f 9 C�4AN I C 4 L PL41�! <br />W <br />I� <br />Z <br />--.••...���� <br />N <br />o <br />Z <br />O LL b <br />•,� <br />co w <br />3 V <br />N <br />Z <br />O <br />H <br />J v <br />N �_ w <br />y ro a <br />N <br />�U <br />� <br />� � * � �•Q� <br />r <br />T <br />• <br />FRO <br />N <br />W <br />LJJ <br />O <br />Nbd O <br />tiul <br />cS 4-' <br />O 0) <br />� U1 <br />Q� S <br />_' U <br />d d <br />:5 U1 <br />_p U1 <br />S d <br />U <br />O <br />U £ <br />d <br />• CDs <br />5- <br />d <br />L� <br />V) <br />t <br />U) <br />0 <br />W <br />� <br />O <br />C3 <br />U <br />•� <br />U <br />Lo <br />N <br />LLn <br />IJ �O <br />r�_ <br />4- <br />•Y > <br />O <br />c <br />N <br />00 <br />(n <br />Ln <br />a <br />� <br />OC) <br />���V)0 <br />N <br />� 0 <br />W_ <br />Z <br />W <br />'u <br />V <br />Z <br />rl <br />0 <br />CD <br />= <br />Cie <br />< <br />m <br />w <br />� <br />J <br />O <br />w <br />O <br />"' <br />m <br />J <br />Z <br />Q <br />= <br />Co <br />CN <br />F — <br />1-, <br />N <br />W <br />z <br />m <br />o <br />o <br />r-- <br />0 <br />m <br />� <br />N <br />Y <br />r- <br />= <br />= <br />N <br />o <br />a <br />o <br />�a <br />• <br />_-. - - <br />. _. _-.� �.-.. .. ... --f •a-• . .. '.. ... ::.� : .. -. .. a. • <br />F <br />r <br />t <br />.. •r. .._ ..5... - <br />• o . <br />J'- .rwa..ic .: tea.-gy- <br />ss J� <br />. - C _mil._ <br />�a- <br />• <br />• <br />a * n r •- <br />• <br />_ <br />e <br />
The URL can be used to link to this page
Your browser does not support the video tag.