Laserfiche WebLink
io <br />F�OCIFTCIF LA I T SCHEDULE <br />MARK <br />MANUFACTURER <br />MODEL <br />AIRFLOLL <br />OUTSIDE AIF <br />AM51ENI <br />EXT. SP <br />DX COOLING COIL <br />ELECTRIC <br />HEAT <br />ELECTRICAL <br />(CFM) <br />(CFM) <br />(OAT) <br />C IN. W.C. ) <br />EAT <br />TOTAL <br />SENSIBLE <br />INPUT <br />OUTPUT <br />V , PH , HZ <br />MCA <br />MOCP <br />EER <br />AF'P@O�XXIIM ATE <br />REMARKS <br />( DB/WB) <br />l BTU/H) <br />l BTU/H) <br />KW) <br />(1'1BH) <br />HP <br />(SEER)�� <br />RTU-1 <br />YORK <br />ZJ060E20 <br />2000 <br />440 <br />105 <br />0.15 <br />80/61 <br />60,000 <br />39,000 <br />20 <br />68 <br />480/3/60 <br />33B <br />35 <br />13.00 <br />1150 <br />1-5 <br />RTU-5 <br />STD <br />RTU-2 <br />YORK <br />ZJ04SE15 <br />1600 <br />352 <br />105 <br />0.15 <br />80/61 <br />48000 <br />35,000 <br />15 <br />51 <br />480/3/60 <br />263 <br />30 <br />13.00 <br />1060 <br />1-5 <br />STD <br />RTU-3 <br />RTU-4 <br />YORK <br />ZJ15OE24N <br />5000 <br />1100 <br />105 <br />0.15 <br />80/6l <br />110,000 <br />121,000 <br />24 <br />82 <br />48S13D/60 <br />42.1 <br />45 <br />11.00 <br />1560 <br />1-5 <br />RTU-6 <br />RTU-1 <br />RTU-8 <br />YORK <br />ZJ120EIS <br />4000 <br />264 <br />105 <br />0.15 <br />80/6l <br />120,000 <br />90,000 <br />18 <br />62 <br />48S/,3D/60 <br />313 <br />35 <br />11-00 <br />130S <br />1-5 <br />RTU-8 <br />YORK <br />ZJ036EO5 <br />1200 <br />264 <br />105 <br />0.15 <br />80/6-1 <br />3fo,000 <br />2-1,000 <br />5 <br />17 <br />4W13D/60 <br />12.8 <br />15 <br />13.00 <br />1000 <br />1-5 <br />ST <br />ACCESSORIES: <br />A. 110V DUPLEX WATER PROOF MAINTENANCE RECEPTACLE. SMOKE DETECTOR- <br />5. NOVAR CONTROLS - FIELD INSTALLED BY NOVAR CONTROLS CONTRACTOR BY TJX. <br />NOTES: <br />1. CONTRACTOR IS TO PROVIDE AND INSTALL ROOF TOP UNIT AND 14' HIGH FACTORY FABRICATED ROOF CURB. <br />2. CONTRACTOR IS TO PROVIDE 1' FARR 30/30 FILTERS, OR EQUAL, ON ALL RTU'S . <br />3. UNITS COME WITH A 5 MINUTE TIME DELAY ON COMPRESSOR START. <br />4. SET 2 POSITION OUTSIDE AIR DAMPER WITH MINIMUM POSITION AS SPECIFIED ABOVE . OUTSIDE AIR <br />DAMPER SHALL FULLY <br />CLOSE UPON UNIT SHUTDOWN . <br />5. PROVIDE TEMPORARY THERMOSTAT. <br />6. PROVIDE AND INSTALL CO2 SENSORS. <br />1. PROVIDE -AND INSTALL 18/10 T'STAT CABLE FOR SENSOR <br />IDIFFUeEfR, <br />MARK <br />MANUFACTURER <br />MODEL <br />TYPE <br />NECK SIZE <br />(L' x W') <br />FACE SIZE <br />(L' x W') <br />FRAME TYPE <br />NC <br />REMARKS <br />A <br />TITUS <br />TMS <br />SQUARE SUPPLY DIFFUSER <br />PER PLAN <br />24'x24' <br />TYPE 3 <br />30 <br />WHITE <br />5 <br />TITUS <br />TMS <br />SQUARE SUPPLY DIFFUSER <br />PER PLAN <br />24'x24' <br />TYPE 1 <br />30 <br />WHITE <br />C <br />TITUS <br />300FL <br />RECTANGULAR SUPPLY DIFFUSER <br />PER PLAN <br />12'x6' <br />TYPE 1 <br />30 <br />WHITE . PROVIDE BOOT W/ SQUARE <br />TO ROUND TRANSITION. <br />D <br />TITUS <br />TMS <br />SQUARE SUPPLY DIFFUSER <br />PER PLAN <br />12'xl2' <br />TYPE 3 <br />30 <br />WHITE <br />E <br />TITUS <br />50F <br />EGGGRATE RETURN GRILL <br />PER PLAN <br />24'x24' <br />TYPE 3 <br />30 <br />WHITE <br />F <br />TITUS <br />350 RL <br />RECTANGULAR RETURN AIR GRILL <br />PER PLAN <br />14'x14' <br />TYPE 1 <br />30 <br />WHITE. PROVIDE BOOT W/ SQUARE <br />TO ROUND TRANSITION. <br />G <br />TITUS <br />50F <br />EGGCRATE EXHAUST GRILL <br />PER PLAN <br />16'x16' <br />PER PLAN <br />30 <br />WHITE <br />H <br />RTS <br />510-50 <br />CONCENTRIC SUPPLY/RETURN <br />(2) 18'x32' <br />48'x42' <br />PER PLAN <br />30 <br />WHITE <br />ELECTRIC LAIT <br />HEATED <br />MARK <br />MANUFACTURER <br />MODEL NO. <br />KW IN <br />BTUH OUT <br />VOLTS/PHASE <br />REMARKS <br />EUH-1 <br />MARKEL <br />P31FI5130CA1N <br />20 KW <br />68200 <br />480/3 <br />VERTICAL MOUNT WITH <br />WALL/CEILING BRACKET <br />EXHAJ5T FAN SCHEDJLE <br />MARK <br />MANUFACTURER <br />MODEL <br />AIRFLOW <br />(CFM) <br />EXT. SP <br />(IN W.G.) <br />V , PH , HZ <br />MOTOR <br />SIZE (HP) <br />EF-1 <br />COOK <br />90SQN10D <br />250 <br />25' <br />120/1/60 <br />1/6 <br />Er--2 <br />COOK <br />90SQNIOD <br />200 <br />.25' <br />120/1/60 <br />1/6 <br />EF-3 <br />COOK <br />120C13D <br />1095 <br />25' <br />120/1/60 <br />1/4 <br />EF-4 <br />COOK <br />90SQN10D <br />250 <br />25' <br />120/1/60 <br />1/6 <br />aDUCT I-4aNG3 <br />SCALE. -NONE <br />L ROOF JOIST <br />__----HANGER WIRE <br />SHEET MTL. DUCT HANGER <br />RECTANGULAR DUCT <br />EXTERNAL INSULATION SHALL <br />BE RUN CONTINUOUS THRU <br />HANGERS <br />IMPORTANT NOTICE: <br />STANDARD LEADTIME FOR YORK RTU HVAC EQUIPMENT IS FOUR (4) WEEKS <br />MANUFACTURING PLUS ONE (1) WEEK TRANSPORTATION DEPENDING ON THE <br />LOCATION IN THE 48 STATES. ANY NON STANDARD OPTION MAY ADD TO <br />THE STANDARD MANUFACTURING LEADTIME AND WILL BE CONFIRMED AT <br />PLACEMENT OF ORDER HVAC EQUIPMENT WITH FACTORY TECHNICOAT <br />COATING OF CONDENSER COILS WILL HAVE AN ELEVEN (I1) WEEK <br />LEADTIME. <br />'G- ROOF JOIST <br />------HANGER WIRE <br />SHEET MTL. DUCT HANGER <br />SPIRAL DUCT <br />__-----EXTERNAL INSULATION SHALL <br />BE RUN CONTINUOUS THRU <br />HANGERS <br />ROUND DUCT HANCsER DETAIL', <br />Z SGALE:NgJE ' <br />2' WIDE MIN. DUCT STRAP <br />48' O.G. MAX. <br />RIGID ROUND METAL DUCT <br />EXTERNALLY INSULATED <br />RIGID ROUND DUCT ELBOW <br />EXTERNALLY INSULATED <br />INSULATED FLEXIBLE DUCT <br />MAX. LENGTH 5'-0' <br />FIRE DAMPER <br />(LOCATION WHE <br />REQUIRED) I <br />VOLUME DAMPER <br />(FOR FINAL BALANCE <br />ADJUSTMENT)- . <br />aHVAC D <br />SCALE -NONE <br />DIFFUSER <br />SPIN -IN FITTING-/ <br />WITH BALANCING DAMPER <br />AND 457 EXTRACTOR <br />(DAMPER USED FOR <br />ROUGH BALANCING) <br />IL ING <br />UCTUJOfR< DETAIL <br />METAL SUPPLY DUCT <br />EXTERNALLY INSULATED <br />GENERAL <br />A. THE GENERAL CONDITIONS OF THE GENERAL SPECIFICATIONS, ALONG <br />WITH ALL APPLICABLE INSTRUCTIONS TO BIDDERS, SHALL FORM A <br />PART OF THIS SECTION OF THE SPECIFICATIONS. <br />B. REFERENCE IS MADE TO REQUISITES FOR BIDDERS AND CONTRACTORS <br />UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, WHICH SHALL <br />BE CONSIDERED BINDING, UNLESS OTHERWISE NOTED UNDER THIS <br />SECTION. <br />.SCOPE <br />EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE <br />CONSTRUCTION DETAILS, BOTH ON TENANT CONSTRUCTION DRAWINGS AND <br />LANDLORD'S AS REFERRED TO, BEFORE SUBMITTING HIS BID AS NO <br />ALLOWANCES WILL BE MADE BECAUSE OF CONTRACTOR'S UNFAMILIARITY <br />WITH THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE <br />AS REQUIRED BY THE PACE OF THE GENERAL CONSTRUCTION. <br />INSPECTION OF SITE <br />ALL PROPOSALS SHALL PRECLUDE THAT CONTRACTOR IS FAMILIAR WITH <br />J0551TE CONDITIONS AND UTILITY LOCATIONS AND THE LACK OF SPECIFIC <br />INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR <br />OF ANY RESPONSIBILITY. <br />PERMITS <br />ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION <br />OF THE WORK SHALL BE SECURED AMC) PAID FOR BY THE SUBCON- <br />TRACTOR INVOLVED. <br />CODE REQUIREMENTS <br />ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS <br />OF THE SPECIFICATIONS, DRAWINGS OR AS DIRECTED BY THE OWNER, <br />AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, AND/OR <br />REGULATIONS OF THE GOVERNING BODIES, WHETHER SO SHOWN OR NOT, <br />AMC) ALL MODIFICATIONS REQUIRED BY SUCH AUTHORITIES SHALL BE <br />MADE BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO OWNER <br />MATERIALS AMC) WORKMANSHIP <br />A. ALL MANUFACTURED ARTICLES, MATERIALS, AMC) EQUIPMENT SHALL <br />BE APPLIED AS RECOMMENDED BY THE MANUFACTURERS, AND UN- <br />LESS OTHERWISE SPECIFIED SHALL BE NEW, AND FREE FROM ANY <br />AND ALL DEFECTS. LIKE MATERIALS USED SHALL BE OF THE SAME <br />MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. <br />B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COM- <br />PETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE <br />MANNER WORK SHALL BE PROPERLY PROTECTED DURING CON- <br />STRUCTION AND COMPLETION, INSTALLATION SHALL BE THOROUGHLY <br />CLEANED OF ALL DEBRIS PRESENT AS A RESULT OF THIS CONTRACT <br />AND SHALL BE REMOVED FROM THE PREMISES, DO NOT ABANDON. <br />CODES AND REGULATIONS <br />EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, <br />RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS <br />DRAWN AND SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THE <br />DRAWINGS AND SPECIFICATIONS ARE At A VARIANCE, HE SHALL PROMPTLY <br />NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF <br />ANY SUBCOMTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY <br />TO LAWS, ORDINANCES, RULES AND REGULATIONS AND WITHOUT GIVING <br />SUCH NOTICE, THE SUBCONTRACTOR SHALL BEAR ALL COSTS ARISING <br />THEREFROM. <br />PROTECTION OF WORK AND PROPERTY <br />A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE <br />PROTECTION OF ALL HIS WORK FROM DAMAGE AND SHALL PROTECT <br />THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS <br />WORK ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT SUCH AS <br />MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND NOT <br />TO HIS FAULT OR NEGLIGENCE, SHALL BE THE RESPONSIBILITY OF <br />THE SUBCONTRACTOR HE SHALL ADEQUATELY PROTECT ADJACENT <br />PROPERTY AS WELL. <br />B. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS <br />FOR THE SAFETY OF THEIR EMPLOYEES ON THE WORK AND SHALL <br />COMPLY WITH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL <br />BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR <br />INJURY TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE <br />THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL <br />MAINTAIN ALL INSURANCE REQUIRED TO PROTECT HIMSELF, THE <br />OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST <br />PROPERTY DAMAGE AND PUBLIC LIABILITY. <br />CHANGES IN THE WORK <br />THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA <br />WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING <br />FROM THE WORK, WITH CONTRACT SUM BEING ADJUSTED ACCORDINGLY. <br />COOPERATION <br />ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN <br />CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT <br />IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE SUF- <br />FICIENT TIME AT THE PROPER STAGE OF CONSTRICTION TO FULFILL HIS <br />CONTRACTS. CONTRACTORS SHALL CONTACT OWNER FOR INSTRUCTIONS <br />SHOULD ANY QUESTIONS ARISE BETWEEN TRADES AS TO THE INSTALL- <br />ATION OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR <br />SHOULD It APPEAR DESIRABLE TO ANY GENERAL CONSTRICTION WHICH <br />WOULD AFFECT THE APPEARANCE OR STRENGTH OF THE STRUCTURE. <br />SUBSTITUTION OF MATERIALS <br />MANUFACTURERS ARE LISTED ON PLANS TO ESTABLISH A STANDARD. <br />THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF IN <br />THE OPINION OF THE TENANT, THE SUBSTITUTE MATERIAL IS OF QUALITY <br />EQUAL TO OR BETTER THAN THE MATERIAL SPECIFIED, AMC) WILL SERVE <br />WITH EQUAL EFFICIENCY AND DEPENDABILITY, FOR THE PURPOSE OF <br />WHICH THE ITEMS SPECIFIED WERE INTENDED. <br />SHOP DRAWINGS <br />SHOP DRAWINGS AMC) CATALOG DATA ON ALL MAJOR ITEMS OF EQUIPMENT <br />AND SYSTEMS, AND OTHER SUCH ILLUSTRATIVE MATERIAL THAT MAY BE <br />CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THIS <br />CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND/OR CON- <br />STRUCTION MODIFICATIONS. <br />DRAWINGS AND SPECIFICATIONS <br />A. THE DRAWINGS DIAGRAMMATICALLY INDICATE THE LOCATIONS OF THE <br />VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND <br />THE METHOD OF CONNECTING AMC) CONTROLLING THEM. It IS NOT <br />INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS <br />REQUIRED FOR A COMPLETE SYSTEM. <br />B. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE CONTRACTOR, <br />TO ANY ITEMS SHOWN ON CONTRACT DRAWINGS, SHOP DRAWINGS, <br />DESCRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES <br />SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. <br />RESPONSIBILITY <br />A. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY <br />AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS CONTRACT. <br />HE SHALL PRODUCE COMPLETE AMC) FULLY OPERATIONAL SYSTEMS AMC) <br />PROVIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS WORK, <br />REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR <br />INDICATED. FOR EXAMPLE, ON SINK INSTALLATIONS, ESCUTCHEONS SHALL <br />BE PROVIDED FOR COUNTERTOP PENETRATIONS, ALTHOUGH THEY WERE <br />NOT SPECIFICALLY IDENTIFIED IN THE CONTRACT DOCUMENTS. <br />B. CONTRACTOR SHALL SUPPLY TO LANDLORD AND TENANT A CERTIFIED <br />AIR BALANCE REPORT AT COMPLETION OF PROJECT. THIS SHALL BE <br />REQUIRED FOR BOTH REMODELED AND NEW STORES. <br />HEATING, VENTILATING AMC) AIR CONDITIONING <br />GENERAL <br />A. THE WORK COVERED BY THIS SECTION OF THESE SPECIFICATIONS <br />SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE RESPECTIVE <br />DRAWINGS, INFORMATION OR INSTRUCTIONS TO BIDDERS, GENERAL <br />CONDITIONS, ADDENDA, OR DIRECTIVES WHICH MAY BE ISSUED BY <br />THE OWNER, SHALL BE COMPLIED WITH IN EVERY ASPECT. <br />B. THE LISTING HEREIN OF AN ARTICLE OR MATERIAL, OPERATION OR <br />METHOD, REQUIRES THAT THE CONTRACTOR SHALL FURNISH AND <br />INSTALL EACH ITEM LISTED, UNLESS SPECIFICALLY NOTED TO THE <br />CONTRARY. THE CONTRACTOR SHALL PERFORM EACH OPERATION <br />PRESCRIBED OR LISTED ACCORDING TO THE CONDITIONS STATED. <br />EXAMINATION OF SITE <br />ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST <br />EXAMINE THE SITE AND ALL EXISTING CONDITIONS AFFECTING HIS WORK <br />ALL PROPOSALS SHALL SPECIFY, IN WRITING, ALL SUCH CONDITIONS <br />THAT MAY ALTER OR AFFECT THE WORK UNDER THIS CONTRACT. <br />SCOPE <br />FURNISH ALL MATERIALS, EQUIPMENT, AND LABOR NECESSARY FOR A <br />COMPLETE AND FULLY OPERATIONAL HEATING, VENTILATING, AND AIR <br />CONDITIONING SYSTEM EXCEPT AS SPECIFICALLY EXCLUDED BY DRAWINGS <br />AND/OR BY TENANT'S DIRECTIONS. <br />EQUIPMENT <br />A. I. EXISTING TO REMAIN. <br />B. FILTERS - FILTERS SHALL BE OF THE THROW AWAY TYPE WHEREVER <br />POSSIBLE. IF FILTERS ARE BY NECESSITY THE PERMANENT TYPE, <br />THEY MUST BE OF THE CLEANABLE, HIGH VELOCITY TYPE AND <br />SHALL BE AMERICAN AIR FILTERS, AIR MAYS, EVANS, OR <br />APPROVED EQUAL. FILTERS SHALL BE OF THE OPTIMUM THICKNESS <br />AND DESIGN FACE VELOCITY SHALL NOT EXCEED 500 FPM. <br />INSTALLATION OF THE AIR CONDITIONING UNIT SHALL NOT IMPEDE <br />OR CONFLICT WITH ACCESS TO FILTERS. IF THE FILTERS ARE IN <br />FRAME HOLDERS, HOLDERS SHALL BE PROVIDED WITH A LEFT <br />HANDLE. <br />C. EXHAUST FANS <br />1. AS INDICATED ON SHEET Mi. <br />D. ALL AIR HANDLING UNITS SHALL BE EQUIPPED WITH PROGRAMABLE <br />THERMOSTAT CAPABLE OF BEING ADJUSTED TO 551F <br />HEATING AMC) 857E COOLING. DESIGN AND STANDARD CONDITIONS <br />FOR THERMOSTAT OPERATION SHALL BE AS FOLLOWS: <br />COOLING: 157F MAXIMUM OCCUPIED COOLING TEMPERATURE <br />857F COOLING NIGHT SETBACK - <br />HEATING: 107F MAXIMUM OCCUPIED HEATING TEMPERATURE <br />607F HEATING NIGHT SETBACK <br />FAN: CONTINUOUS IN OCCUPIED AND RECOVERY MODE AND WITH <br />HEATING OR COOLING EQUIPMENT IN UNOCCUPIED MODE. <br />DEADBAND: CAPABLE OF MAINTAINING A 57F DEADBAND. <br />CLOCK: i DAY CAPABLE OF -1 DIFFERENT DAY SCHEDULES. <br />OVERNIGHT: HAVE A 2 HOUR OVERRIDE ACCESSIBLE TO MANAGER <br />BACKUP: CAPABLE OF MAINTAINING PROGRAMMED SETTING FOR AT <br />LEAST 10 HOURS WITHOUT POWER <br />BEAM <br />BEAM <br />X <br />N <br />CLEVIS HANGER <br />OVERSIZED FOR <br />INSULATION <br />WITH 18' ROLLED <br />SLEEVE FOR <br />SUPPORT IS07 - <br />all PIPEANCzER DETAIL <br />SCALE: <br />HANGER SPACING AND ROD SIZE <br />PIPE <br />MAX <br />ROD <br />SIZE <br />SPAN <br />SIZE <br />1/2' <br />-1' <br />3/8, <br />3/4' <br />i' <br />3/5, <br />1' <br />l' <br />3/8, <br />11/4' <br />i' <br />3/8, <br />11/2" <br />9' <br />3/5, <br />2' <br />10' <br />3/8, <br />2 1/2' <br />11' <br />1/2' <br />3 <br />12' <br />1/2' <br />31/2' <br />13' <br />1/2' <br />4' <br />14' <br />5/8' <br />5' <br />16' <br />5/5, <br />6' <br />17' <br />3/4' <br />8' <br />19' <br />3/4' <br />10, <br />22' <br />1/5" <br />12' <br />23' <br />I/8" <br />14' <br />25' <br />1' <br />16' <br />21' <br />1' <br />18' <br />28' <br />1' <br />20' <br />30' <br />11/4, <br />24 <br />32' <br />11/4" <br />4k (It ssuihrr <br />DUCTWORK <br />J <br />`��. •�......,�.��y,�, <br />A. SQUARE/RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED OF NEII <br />_ <br />F <br />N <br />lz <br />0.6' <br />�, <br />GALVANIZED PRIME GRADE SHEET STEEL OF THE FOLLOWING GAUGES 0' <br />N <br />Z <br />ra . N o <br />DUCT SIZE GAUGEo <br />N <br />O <br />=? w r:J. <br />12' AND LESS NO. 2fo U.S. GAUGE <br />`~ <br />s > <br />.✓` o r o- <br />13' TO 30' NO. 24 U.S. GAUGE <br />Q <br />b - �, <br />31' TO 54' NO. 22 U S. GAUGE " <br />N <br />W <br />U-i <br />• . <br />i ........ <br />55' TO 84' NO. 20 U.S. GAUGE <br />E <br />,,r� Q�;. • <br />86' AND OVER NO. 18 U.S. GAUGE <br />r'r'r"`• <br />ALL EXHAUST AMC) RELIEF AIR DUCTS SHALL BE GALVANIZED STEEL. <br />B. SQUARE AND RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED AS <br />FOLLOWS: <br />SIZE METHOD <br />11' AND LESS 'S' AND DRIVE CLEATS <br />18' TO 30' 'L' STANDING SEAMS ON <br />V -0' CENTERS <br />31' TO 54' 1-1/4' STAND ING SEAMS <br />ON V-0' CENTERS <br />ROUND DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED <br />PRIME GRADE SHEET STEEL OF THE FOLLOWING GAUGES: <br />DUCT SIZE (DIAMETER) DUCTS FITTINGS <br />8' AND LESS 24 22 <br />V TO 18" 22 20 <br />IV TO 30' 20 18 <br />ALL SO DEGREE ELBOWS FOR ROUND DUCTWORK SHALL BE FIVE (5) <br />PIECE. ALL LONGITUDINAL SEAMS SHALL BE FORMED BY PITTSBURGH <br />LOCKS. JOINTS SHALL BE SWAGGED WITH ONE-HALF INCH (1/2') <br />OVERLAP. <br />C. ALL SUPPLY AIR DUCTS (HEATING AND COOLING), RETURN AIR <br />DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED STEEL WITH <br />MINIMUM 2' (INSTALLED R-5 MIN.) THICK EXTERNAL INSULATION <br />WITH VAPOR BARRIER <br />D. CONTRACTOR SHALL SUPPLY AMC) INSTALL INSECT SCREENS ON ALL <br />DUCT OPENINGS WHICH TERMINATE OUTDOORS. INSECT SCREENS <br />SHALL BE 10 GAUGE, ONE -HALF INCH (1/2') MESH IN REMOVABLE <br />GALVANIZED STEEL FRAMES. <br />E. ALL DUCTWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE <br />PROCEDURES DESCRIBED IN THE LATEST EDITION OF THE AMERICAN <br />SOCIETY OF HEATING REFRIGERATION AMC) AIR CONDITIONING ENGINEERS <br />GUIDE (ASHRAE), FABRICATED AMC) INSTALLED IN ACCORDANCE WITH <br />THE METHODS RECOMMENDED IN THE SHEET METAL AMC) AIR CON- <br />DITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA) LOW <br />VELOCITY DUCT MANUAL, LATEST EDITION. <br />I. ALL JOINTS, LONGITUDINAL AMC) TRANSVERSE SEAMS, AND <br />CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING <br />WELDMENTS± MECHANICAL FASTENERS WITH SEALS, GASKETS, OR <br />MASTICS± MESH AND MASTIC SEALING SYSTEMS± OR TAPES. TAPES AND <br />MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL <br />181A OR UL 1815. ALL LONGITUDINAL AND TRANSVERSE JOINTS, <br />SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING <br />AT STATIC PRESSURES LESS THAN OR EQUAL TO 2' W.G. SHALL BE <br />SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS <br />(ADHESIVES), MASTIC -PLUS -EMBEDDED FABRIC SYSTEMS OR TAPES <br />INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. <br />2. MECHANICAL FASTENERS AMC) SEALS, MASTICS, OR GASKETS MUST <br />BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR <br />DISTRIBUTION EQUIPMENT. <br />F. FLEXIBLE AIR DUCT FOR CONNECTIONS BETWEEN S.M. DUCT AND <br />DIFFUSER SHALL BE AIR DUCT LISTED BY UNDERWRITERS LABORATORIES <br />UNDER UL STANDARD 181 AS A GLASS 1 FLEXIBLE AIR DUCT AND <br />COMPLYING WITH NFPA STANDARDS SOA AND S08. DUCT SHALL BE <br />FACTORY MADE AND COMPOSED OF A CPE LINER DUCT PERMANENTLY <br />BOUNDED TO A COATED SPRING STEEL WIRE HELIX AND SUPPORTING A <br />FIBER GLASS INSULATING BLANKET. R.-5.0 LOW PERMEABILITY OUTER <br />VAPOR BARRIER OF FIBER GLASS REINFORCED FILM LAMINATE SHALL <br />COMPLETE THE COMPOSITE. <br />HANGERS AND SUPPORTS <br />A. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND <br />LESS SHALL BE SUPPORTED BY MEANS OF BAND IRON HANGERS <br />OF NO. 18 U.S. GAUGE ATTACHED TO DUCT BY MEANS OF RIVETS, <br />SCREWS OR CLAMPS, AMC) FASTENED TO STRUCTURE ABOVE BY <br />TOGGLE BOLTS OR OTHER MEANS. EACH SECTION OF DUCTWORK <br />SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. VERTICAL DUCTS <br />SHALL BE SUPPORTED WITH 1-1/4' x 1-1/4' x 1-1/4' ANGLES <br />AT FLOOR PENETRATIONS. <br />B. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND <br />MORE SHALL BE SUPPORTED BY MEANS OF ANGLE IRON TRAPEZE <br />HANGERS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST <br />ONE PAIR OF SUPPORTS. <br />FLASHING <br />A. CONTRACTOR SHALL PROVIDE WATER TIGHT 24 GA. SHEET METAL <br />FLASHINGS AT ALL EXTERIOR WALLS AND ROOF PENETRATIONS. <br />B. ALL CUTTING OF ROOF OPENINGS, SUPPORTS FOR ROOF OPENINGS, <br />PITCH PANS, ROOF CURBS, FLASHINGS, COUNTER FLASHINGS, REPAIR <br />TO ROOF, ETC. ASSOCIATED WITH HVAC SUBCONTRACTOR SHALL BE <br />INCLUDED IN THE RESPONSIBILITY OF THE HVAC SUBCONTRACTOR. <br />HE SHALL EMPLOY THE LANDLORD'S ROOFERS FOR THIS WORK TO <br />MAINTAIN THE ROOF WARRANTY. <br />DAMPERS <br />A. SPLITTER DAMPERS SHALL BE FABRICATED OF SHEET STEEL NOT <br />LESS THAN NO. 16 U.S. GAUGE WITH THE LEADING EDGE HEMMED. <br />EACH DAMPER TO BE SIZED ADEQUATELY TO COVER THE SMALLER <br />OF THE TWO OPENINGS IT CONTROLS. DAMPERS SHALL BE <br />CONTROLLED AS FOLLOWS: <br />EXPOSED OR ACCESSIBLE DUCTWORK - LOCKING QUADRANTS EQUAL <br />TO YOUNG REGULATOR NO. 1 WITH DAMPER ROD END BEARINGS ON <br />OPPOSITE END. <br />CONCEALED DUCTWORK - LOCKING QUADRANT EQUAL TO YOUNG <br />REGULATOR NO. 315 (CHROMIUM PLATED WITH DAMPER ROD END <br />BEARINGS ON BOTH ENDS). <br />B. VOLUME DAMPERS SHALL BE OF THE OPPOSED INTERLOCKING TYPE <br />AS MANUFACTURED BY AMERICAN FOUNDRY AND FURNACES CO. <br />(AFFCO) OR EQUAL. BLADES SHALL BE OF NO. Ifo GAUGE SHEET <br />METAL AND SHALL NOT EXCEED 48' IN LENGTH OR 12' IN WIDTH. <br />BLADES SHALL BE ON ONE-HALF INCH (1/29 DIAMETER RUSTPROOF <br />AXLE. BEARINGS TO BE OF THE SELF-LUBRICATING FERRULE TYPE. <br />C. FIRE DAMPERS SHALL BE SUPPLIED AND INSTALLED BY HVAC CON- <br />TRACTOR AT DUCT PENETRATIONS IN FIRE RATED WALLS, FLOORS, <br />CEILINGS AND ROOF AS REQUIRED. COORDINATE WITH LANDLORD, <br />LOCAL FIRE MARSHALL AND ALL CODES AND GOVERNING AUTHORITES <br />HAVING JURISDICTION. <br />D. FIELD FABRICATED TURNING VANES SHALL BE ACCEPTABLE IN <br />SQUARE ELBOWS. PROVIDE AND INSTALL BARBER-COLMAN AIRTURNS <br />OR EQUAL. TURNING VANES SHALL BE OF THE SAME GAUGE METAL <br />AS THE DUCT IN WHICH THEY ARE INSTALLED. RADIUS ELBOWS <br />SHALL HAVE A CENTER LINE RADIUS OF ONE AND ONE-HALF (1-1/2) <br />TIMES THE DUCT WIDTH. <br />DUCTWORK - EXCEPTIONS <br />DUCTWORK FOR EXHAUST OR OUTSIDE SUPPLY AIR SHALL BE ALL <br />METAL AND CONSTRICTED ACCORDING TO RECOMMENDED PRACTICES <br />OF THE LATEST ISSUE OF ASHRAE. <br />SUPPORT OF DUCT SYSTEM <br />HANGER DESIGN SHALL BE AS DESCRIBED IN THE LATEST EDITION OF <br />THE "SMACNA' MANUAL. RE INFORCEMENT MEMBERS MAY BE USED TO <br />SUPPORT DUCT SYSTEM PROVIDED DETAILS OUTLINED IN THE 'SMACNA' <br />MANUAL ARE ADHERED TO. <br />DUCTS SHALL BE SUPPORTED AT ALL TURNS AND TRANSITIONS AND NOT <br />MORE THAN 8'-0' O.G. STRAIGHT DUCTS UP TO 59" MAX. DIMENSIONS <br />SHALL BE SUPPORTED 6'-O' O.G. DUCTS OVER 60' MAX. DIMENSIONS <br />SHALL BE SUPPORTED At 4'-O' O.G. <br />REINFORCEMENT <br />ALL DUCTS SHALL BE REINFORCED ACCORDING TO THE LATEST EDITION <br />OF SMACNA MANUAL. MATERIALS FOR REINFORCEMENT MEMBERS SHALL <br />BE GALVANIZED STEEL. ALL SCREWS AND WASHERS SHALL BE PLATED <br />OR GALVANIZED. <br />TESTING AND ADJUSTING <br />CONTRACTOR SHALL DEMONSTRATE OPERATION OF SYSTEM TO FULL <br />SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW IN ACCORDANCE <br />WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD VOLUME <br />READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT. <br />OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO <br />THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: <br />A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED <br />MAINTENANCE ACTIONS. <br />B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. <br />C. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION <br />INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND <br />CONTROL SEQUENCE DESCRIPTIONS± DESIRED OR FIELD -DETERMINED <br />SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL <br />DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL <br />SYSTEMS, IN PROGRAMMING COMMENTS. <br />OPERATE. <br />D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO <br />ALL PIPING SHALL WITHSTAND AIR PRESSURE TESTING PER <br />GOVERNING PLUMBING CODE. <br />GUARANTEE <br />ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED <br />FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE <br />COMPLETED SYSTEM SHALL BE FULLY OPERATIIONAL AND ACCEPTANCE <br />BY TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK <br />FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THIS <br />SUBCONTRACTOR WITHOUT ADDITIONAL COST TO THE TENANT. <br />ACCESSORY ITEMS <br />ALL MANUAL DAMPERS, FIRE DAMPERS, TURNING VANES, REGISTER CON- <br />NECTIONS, ACCESS DOORS OR OTHER ASSOCIATED ACCESSORIES SHALL <br />BE INSTALLED ACCORDING TO THE LATEST EDITION OF 'SMACNA' MANUAL. <br />SPRINKLER SYSTEM <br />A. SHOP DRAWINGS -THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP <br />DRAWINGS TO THE TENANT'S LANDLORD AND TO THE APPROPRIATE <br />AUTHORITIES AND INSURANCE UNDERWRITER FOR THEIR APPROVAL. <br />A COPY OF THE APPROVAL LETTER FROM THESE AUTHORITIES SHALL <br />BE FORWARDED TO THE TENANT, LANDLORD AND DESIGN ARCHITECT. <br />B. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: <br />1. SHOW WINDOWS: <br />HIGH TEMPERATURE, FULLY RECESSED, PAINT TO MATCH CEILING <br />2. AREAS WITH CEILINGS: <br />FULLY RECESSED, PAINT TO MATCH CEILING <br />3. PUBLIC AREAS WITH OPEN TO DECK CEILINGS: <br />CHROME, UPRIGHT <br />4. STOCK AREAS OPEN TO DECK: <br />BRASS, UPRIGHT <br />NOTE FOR GENERAL CONTRACTOR: <br />IT IS THE RESPONSIBILITY OF THE TENANT'S GENERAL CONTRACTOR TO <br />MAKE USE OF APPLICABLE NOTES AND SPECIFICATIONS LISTED ON THIS <br />SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB. <br />0 <br />kid 0 <br />75 +> <br />d 4-' <br />O 0) <br /><n <br />Q� S <br />+' U <br />d d <br />:5 In <br />IELn <br />S d <br />U <br />O <br />U E <br />d <br />o S <br />D) <br />• d <br />d <br />L <br />LL- <br />V) <br />U) <br />N <br />N <br />V) <br />W d <br />c <br />O <br />D <br />U <br />0 <br />LC) <br />41 <br />i <br />0 O <br />OX <br />�•U:2L� <br />c <br />CN " <br />C O <br />cf) <br />-s-- Ln <br />(D <br />U) t) <br />Lu <br />Z <br />Lu <br />!u <br />V <br />z <br />O <br />= <br />Q C) <br />t� <br />w � <br />—) O <br />w <br />=) J <br />O `L <br />m � <br />J_ J <br />Z <br />¢ _ <br />0 <br />O <br />CN <br />CN <br />H- <br />I� N <br />w <br />a <br />z <br />z <br />0 <br />F <br />EL <br />w <br />U <br />w <br />0 <br />I <br />k <br />a <br />0 <br />w <br />rn <br />0 <br />or..- <br />I <br />o <br />� <br />z <br />O <br />N <br />U <br />:0 <br />� LAJ <br />LLj <br />C:) <br />d <br />�12 <br />