Laserfiche WebLink
- <br />CLEAR ANODIZED <br />ALUM. FRAME WITH <br />INSULATED GLAZING <br />4 <br />C) C)SECTIONAL OVERN <br />I <br />� a <br />z <br />ti <br />PADLOCKING TRACK LATCH <br />TYPE A AT BOTH TRACKS <br />TYPE D <br />180' DOOR VIEWER @ +60" AFF <br />1-3/4", PAINTED, FLUSH HOLLOW I <br />PRE FINISI-IED <br />MARATHON PACKAGF <br />CHUTE SECURITY DOOR <br />SLIDE BOLT WITH LATCH \ <br />AND CHAIN FOR G,C, <br />SUPPLIED BEST PADLOCK <br />I <br />FINISH FLR. <br />TYPE K <br />ri__�DOOR YE13 <br />�,A_!LO SCALE: N.T.S. <br />IYPE E <br />TYPE H <br />IAICH Al <br />BOTH SIDES <br />CENTERED 180' <br />VIEWER AT 5'-0" <br />A.F.F. <br />DOOR TYPE NOTES <br />THE FOLLOWING ARE THE ROSS MINIMUM ACCESSIBILITY REQUIREMENIS FOR OPERABLE INTERIOR <br />/ EXTERIOR DOORS AT ROSS STORES REGARDLESS OF LESSER OR ABSENI REQUIREMENTS OF <br />GOVERNMENTAL AUTHORITY. MERE SHALL BE NO CASTS WHERE THE OPERABLE DOORS AT ROSS <br />STORES DO NOI MEET THE FOLLOWING MINIMUM REQUIREMENTS. LANDLORD MUST ENSURE THAT <br />IF HIGHER OR MORE STRINGENT STANDARDS ARE REQUIRED BY GOVERNMENTAL AUTHORITY THAT <br />THOSE HIGHER STANDARDS ARE MET. <br />1. DOORS MUST BE A MINIMUM OF 3'-0" WIDE AND 6'-8" HIGH. <br />2, DOORS MUST OPEN A MINIMUM OF 90 DEGREES. <br />3. CLEAR WIDTH OF DOORWAYS MUST BE 32" MINIMUM, <br />4. DOUBLE DOORS / AUTOMATIC DOORS AT IFAST ONE LEAF MUST COMPLY WITH ITEMS 1 <br />THROUGH 3 ABOVE, <br />5. THE BOTTOM 10" OF Al,I DOORS, EXCEPT AUTOMATIC AND SLIDING DOORS, SHALL HAVE A <br />SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR <br />FOOTREST WITHOIJI CRFAHNG A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS <br />ARE USED, A 10" HIGH SMOOTH PANEL SHALL BE INSIAI I_I I) ON TIIE PUSH SIDE OF THE DOOR, <br />WHICH ALLOWS THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT A TRAP OR <br />HAZARDOUS CONDITION, <br />6. M S MAXIMUM EFFORT TO OPERATE DOOR SHALL NOT EXCEED 5 LBS, FOR EXTERIOR AND <br />INTERIOR DOOR, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED <br />DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSAIING DEVICES OR <br />AUIOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE <br />DOORS ARE REQUIRED THE MAXIMUM EFFORI 10 OPERATE THE DOOR MAY BE INCREASED TO <br />THE MINIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, BUI SHALT- NOT <br />EXCEED 15 1,13S. <br />/. IF IHE DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE <br />ADJUSTED SO THAT FROM AN OPEN POSITION OF /0 DEGREES, THE DOOR Will- TAKE AT LEAST <br />3 SECONDS TO MOVE TO A POINT 3" FROM THE LATCH, MEASURED TO THE LANDING EDGE OF <br />DOOR, <br />8. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" AND 44" <br />ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE <br />IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, <br />PANIC B AS, PUSI-I-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE <br />PASSAGE WITHOUT REQUIRING THE ABILITY 10 GRASP THE OPENING HARDWARE, <br />9. WHERE THE PLANE OF THE DOORWAY IS OFFSET 8 OR MORE INCHES FROM ANY <br />OBSTRUCTION WITHIN 18" MEASURED LATERAI I Y ON IHE LATCH SIDE, THE DOOR SHALL BE <br />PROVIDED WITH MANEUVERING CLEARANCE FOR FRONT APPROACH. <br />10, <br />. FLOOR OR LANDING ON EACH SIDE OF THE DOOR TO BE LEVEL AND CLEAR. l FVl I ARE <br />A <br />IN THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF 60" IN LENGTH, LEVEL AREA <br />OPPOSITE THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF 44-48" IN LENGTH, <br />DEPENDENT UPON DIRECTION OF THE APPROACH & EXISTENCE OF A LATCH & CLOSER. SURFACE <br />SLOPE OF THE LEVEL AREA SHALL NOT EXCEED 1:50 GRADIENT (2%). <br />11. TIFF WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL <br />EXTFND 24" PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS & 18" PAST THE <br />STRIKE EDGE FOR INTERIOR DOORS. <br />DOOR SCHEDULE - <br />DOOR NUMBER <br />TYPE <br />W <br />H <br />D <br />IIARDWARE TYPE (SEE NOTE 7L) <br />1 STOREFRONT <br />A <br />11'-0" <br />7'-0" <br />- <br />KEYED LOCKSET <br />SLIDING DOOR <br />C°J VESTIBULE <br />J <br />8' 6" <br />7'-0" <br />- <br />NO LOCKSET <br />°J SLIDING DOOR <br />DFI AYED EXIT DEVICE <br />C) EXIT <br />D <br />3'-0" <br />7'-0" <br />1 3/4" <br />(SEE NOIL 15) <br />EXTERIOR OPERABLE HARDWARE <br />� PROCESSING ROOM <br />IT <br />3'-0" <br />7'-0" <br />1 3/4" <br />PANIC DEVICE <br />(SEE NOTE 20) <br />�.`'./ MAN DOOR <br />NO EXTERIOR OPERABLE HARDWARE <br />DELAYED EXIT DEVICE <br />EXIT <br />D <br />3'-0" <br />7' 0" <br />1 3/4" <br />(SEE NOTE 15) <br />NO EXTERIOR OPERABIC HARDWARE <br />17 TRASII COMPACTOR <br />K <br />S-4" <br />S-4" <br />- <br />CASE OPENING, SLIDEB01_T, BEST PADLOCK & CHAIN <br />(.SEE NODE 4A) <br />17 RECEIVING <br />- <br />SLIDE BOLT EACH SIDE <br />(I7B OVERHEAD <br />(SEE NOTE 19) <br />18 ROOF IIATCI1 <br />- <br />2'-6" <br />3'-0" <br />- <br />- <br />19 ROOF ACCESS <br />D <br />3'-0" <br />6'-0" <br />1 3/4" <br />KEYED DEADBOLT WITH THUMB TURN, <br />FULL WEATHERING & RAIN HOOD <br />- <br />- <br />- <br />�A) SHUTTERNF <br />- <br />LEGEND <br />ALUM <br />ALUMINUM <br />HM <br />HOLLOW METAL <br />SC <br />SOLID CORE <br />MTL <br />METAL <br />TCR <br />THERMACORE <br />CAF <br />CLEAR ANODIZED FINISH <br />PC <br />PLASTIC HONEYCOMB CORE <br />MATERAAI <br />FINISII <br />REMARKS <br />DOOR FRAME <br />ALUM <br />ALUM <br />CAF <br />FACfOKY /-PIN INTERIOR CYLINDER AND OUTSIDE BLANK <br />54" NOM CLEAR OPENING. (SEE NOTE 1). PACKAGE HEIGHT 13'-6" <br />44" NOM CLEAR OPENING; SEE SHEET A1.2 (SEE NOTE 1) PACKAGE HEIGHT 13'-6" <br />ALUM <br />ALUM <br />CAT- <br />HM <br />HM <br />PAINT <br />STOP FACE MOUNT SFI F CLOSER (PREPAINT TO MARCH INT, DOOR COLOR). BEST 7-PIN MORTISE CYL., PRFPARF DR & <br />FRAME FOR CONCEALED INSTALLATION; CONNECTION RCQ'D TO FIRL DEFECTION SYSTEM. (SEE NOTE 2.9) <br />HM <br />HM <br />PAINT <br />- <br />180 DEGREE VIEWER (SEE NOTE 12), STOP FACE MOUNT SELF -CLOSER, FULL CANOPY, HF.�S, I /-PIN CYL, 'D' HANDLE <br />AT INTERIOR ABOVE ARROW EXIT DEVICE AT +54" A.F,F. TO CLOSE DOOR (SEE NOTE 24) <br />HIM <br />HM <br />PAINT <br />STOP FACE MOUNT SELF CLOSER (PPREPAINT TO MATCH INT. DOOR COLOR). BEST 7-PIN MORTISE CYL., PREPARE DR & <br />FRAME FOR CONCEALED INSTALLATON; CONNECTION RFQ'D TO FIRE DETECTION SYSTEM (SEE NOTE 29) <br />MTL <br />MTL <br />PAINT <br />DOOR, FRAME & CHUTE IN MARATHON RAM -JET COMPACTOR PACKAGE (WITH SLIDEBCLT & LATCH FOR PADLOCK) BY <br />G.C., SILL AT +40", INSURE ADEQUATE SLOPE IN CHUTE. <br />TCR <br />MTL <br />PAINT <br />INSULATED SECTIONAL OVERHEAD DOOR, TWO SLIDE BOLTS AT 36", PADLOCKS EACH SIDE (SEE NODE 9B), VERTICAL <br />OVERHEAD PARKING, 180' VIEWER CENTERED IN EACH (SFF NOTE 12) <br />MTL <br />MTL <br />PAINT <br />BES I PADLOCK (SEE NOTE 4A); SAFETY POLE, SCC DETAILS 3 & 4/A1.1; BILCO OR APPROVED EQUAL <br />HM <br />HM <br />PAIN I <br />BEST 7-PIN CYLINDER, DRIP EDGE, SIGN WORK CAVITY ACCESS LOCATED ON ROOF. DOOR SILL/THRESHOLD TO BE <br />1'-0" ABOVE FINISHED ROOF. <br />- <br />- <br />VERIFY WHERE REQUIRED, SEE NOIT 8.2 ON SHEET G1,1 <br />GENERAL HARDWARE NOTES <br />A. SEE DETAIL 4/A51 FOR TYPICAL HEAD DETAILS AT EXTERIOR HOLLOW METAL DOORS & FRAMES IN CMU WALL, U.O.N. <br />ROOM FINISH SCHEDULE <br />ROOM <br />FLOOR <br />(SEE <br />NOTE <br />6) <br />WALLS <br />WALL <br />FINISH <br />CEILING <br />OTHER <br />COLUMNS <br />DOOR <br />REMARKS <br />FRAMES <br />- _ <br />AND <br />TRIM <br />- <br />43 <br />C) <br />c <br />� <br />w <br />W <br />I <br />�` <br />I <br />0 <br />w <br />Elf <br />w <br />w <br />C) <br />z <br />Imo- <br />m <br />a <br />z <br />W <br />z <br />C <br />c <br />W <br />W <br />- <br />c <br />'I <br />t <br />C) <br />C� <br />U <br />x <br />w <br />a <br />n- <br />cn <br />cn <br />cn <br />V) <br />\ <br />C] <br />� <br />U <br />W <br />u <br />Z <br />C/) <br />J <br />J <br />J <br />U <br />- <br />I- <br />C! <br />C <br />2 <br />d <br />� <br />CD <br />LEI <br />U <br />4 <br />�1 <br />C)-cC <br />a <br />r� <br />m <br />C ) <br />C9 <br />ca <br />c_ <br />W <br />r <br />z <br />o <br />W <br />s <br />0 <br />>= <br />� <br />� <br />5 <br />� <br />it <br />U) <br />cam, <br />5 <br />w <br />Ili <br />� <br />w <br />.• <br />-J <br />~ <br />W <br />L� <br />'ice- <br />U7 <br />w <br />C= <br />C7 <br />LL <br />C7 <br />C <br />U <br />LL <br />J <br />1- <br />= <br />d <br />d <br />F-- <br />J <br />d <br />Z <br />C> <br />7' <br />O of <br />C D <br />_ <br />L,J <br />U) <br />� <br />C] <br />W <br />« <br />W <br />V) <br />Y <br />CD <br />J <br />tZ. <br />Z <br />.1 <br />_J <br />W <br />C5 <br />I,_I <br />V) <br />O <br />Y <br />CD <br />`. L <br />l,-I <br />V) <br />C� <br />m <br />W <br />V) <br />m <br />W <br />M <br />� <br />4 <br />o <br />< <br />V) <br />n' <br />W <br />J <br />0 <br />x <br />m <br />C) <br />,J-_ <br />Q <br /><C <br />c+)O <br />d- <br />7 <br />Chi <br />x <br />w <br />(l <br />a <br />_ <br />a <br />20 <br />_ <br />C) <br />d- <br />x <br />w <br />J <br />w <br />c <br />cc <br />n <br />= <br />w <br />Q <br />x <br />W <br />CAL, <br />x <br />W <br />2n <br />� <br />CC <br />U <br />x <br />a <br />o <br />o_ <br />N0. <br />NAME <br />101 <br />SALES FLOOR <br />- <br />102 <br />PROCESSING ROOM <br />GENERAL FINISH SCHEDULE NOTES <br />A. NOT USED <br />B. NOT USED <br />C. STRAIGHT RUN HILL ON SALES FLOOR 10 BE FULL, ALIGNED TILES WHERE POSSIBLE. OBTAIN MOST RECENT LAYOUT FROM ROSS CONSTRUCTION REPRESENTATIVE <br />PRIOR 10 INSTALLATION, FOLLOW MANUFACTURER'S INSTALLATION MANUAL, SHADE MATCHING MUST BE CHECKED. <br />D. Al AEI. DRYWALL, TAPE, FILL AND SAND EXPOSED DRYWAI_I_ JOINIS AND SURFACES TO PRODUCE A SMOOTH UN -TEXTURED SURFACE, PRIMED AND READY FOR <br />SPECIFIED FINISH. FEATHER COATS ONTO ADJOINING SURFACES SO THAT CAMBER IS MAXIMUM 1/32 INCH. ALL WORK SHALL BE IN ACCORDANCE WITH GYPSUM <br />ASSOCIATION SPECIFICATION GA 216, FINISH AS SPECIFIED. <br />E. ALL EXPOSED CONCRETE OR MASONRY WALL SURFACES SHALL BE CLEANED, SEALED AND PAINTED. <br />F. CONCRETE STALER TO BE APPLIED TO NEW & EXISTING CONCRETE SLABS (INCLUDING THE SALES FLOOR) PER ROOM FINISH & MATERIAL. NOTE 6 & 7. <br />DOOR AND HARDWARE NOTES <br />1. STOREFRONT DOORS <br />A. DOORS % 1, 1A & 2A SHALL BE STANLEY DURA-GLIDE 3000 BI-DINECTIONAL OPERATION AND BE FITTED WITH STANDARD STANLEY HARDWARE. <br />B, DOORS NO. 2 & 2B SHAI I BE STANI EY DURA-GI Ilk 6000 UNI-DIRECTIONAL OPERATION AND BE FITTED WITH STANDARD STANLEY HARDWARE. <br />C. DOORS 2 & 1A REQUIRES 7-PIN EXTERIOR/INTERIOR CYLINDER. <br />DOOR 1 REQUIRES 7-PIN INTERIOR CYLINDER ONLY. <br />DOORS 2A & 2B TO HAVE NO LOCKSET. <br />D. ALL EXPOSED HOLES IN STOREFRONT DOORS ARE TO BE FILLED WITH FLUSH BIANKS FINISHED TO MATCH DOOR ALUMINUM <br />E• ALL STORE FRONT DOORS SHALL BE PROVIDED WITH CODE REQUIRED ACCESSIBILITY SIGNING AS REQUIRED BY LOCAL AUTHORITY. <br />F. NO THUMB TURNS, <br />2. INILROR DOORS OPENING TO A PERPENDICULAR WALL MUST HAVE WALL STOPS WITH CONC'LALLD MOUNTING MOUNTED TO SOLID IN WALL BLOCKING. HALER <br />23OW CONVEX WALL STOP 2-3/9" DIA, 1-3/16" PROJECTION, 626 SATIN CHROME FINISH, <br />3. DOORS WITHIN ACCESSIBLE PAIH OF 1RAVEL TO BE OPENABLE WITH A SINGLE EFFORT BY LEVER, PANIC BAR OR PUSH/PU11 HARDWARE. DOOR <br />OPENING HARDWARE TO BE BETWEEN 30" 10 44" A.F.F., EXCEPT AS PROVIDED BY CODE (SEE 1 ABOVE). <br />4. PADLOCK <br />A. ROOF HATCH AND COMPACTOR DOOR PROVIDE ONE (1) EACH 7-PIN BEST 91B72-M1 PADLOCK WITH CHAIN (BY G,C.) <br />B. OVERHEAD DOOR PROVIDE TWO (2) EACH 7-PIN BEST 41B72-M1 PADLOCK WITH CHAIN (BY G.C.) PER DOOR. <br />5. DOORS OTHER THAN STOREFRONT WHICH RFQUIRF CLOSERS SHALL RECEIVE AN "LCN" #9091 CLOSER, AS INDICATED IN SCHEDULE. DOOR CLOSERS TO BE <br />ADJUSTED TO PROVIDE FOR A MAXIMUM EFFORT TO OPERATE OF 5 POUNDS FOR INTERIOR DOORS AND 8.5 POUNDS FOR EXTERIOR DOORS. EFFORT MAY <br />INCREASE TO 15 POUNDS MAXIMUM AT FIRE DOORS, CLOSERS MUST ALLOW THREE SECONDS 10 MOVE DOOR FROM A 70 DECREE OPEN POSITION TO A POINT <br />3" FROM THE LATCH. IF CONFLICT WITH CODE, FIRE & LIFE SAFETY CODE SHALL PREVAIL. DO NOT USE HOLD OPEN DEVICES. <br />6. THRESHOLDS SHALL NOT EXCEED 1/2" IN HEIGHT <br />7. LOCKSETS/LATCHSETS <br />A, INTERIOR LOCKSETS TO BE BEST #93K7AB14C626 W/ CURVED RETURN LEVERS LOCKSETS 10 AVIF BEST 7 PIN CYLINDER <br />B. INTERIOR LAICHSEIS TO BE BEST #93KON14C626 W/ CURVED RETURN LEVERS <br />C. MANAGER OFFICE AND EQIPMENT CLOSET TO RECEIVE BEST #93K7-D-14C626 W/ CURVED RETURN LEVERS AND BEST 7-PIN CYLINDER <br />D. CASH OFFICE TO RECEIVE BEST 45117-TD-14-11-626 MORTISE LOCK W/ INTERLOCKING DEADBOLT COMBINATION. BEST 7-PIN CYLINDER W/ CURVED <br />RETURN LEVERS <br />E. All I ATCI ISFT AND I OCKSCTS TO BE BEST. NO SUBSTITUTIONS WILL BE ACCEPTED <br />8. WOOD AND H.M. DOORS TO HAVE 3 FULL BEARING MORTISE HINGES WITH NON REMOVABLE HINGE PINS, DOOR CLOSERS, AND DOOR STOPS (INTERIOR DOORS), <br />FINISH US26D (SAIIN CHROME). HINGES ON All EXTERIOR HIM MAN DOORS ARE TO BE STAINLESS STEEL. <br />9. HOLLOW METAL FRAMES SHALL BE 18 GA. PRESSED, FLUSH TYPE WITH MITERED AND WELDED CORNERS. CASH OFFICE FRAME SHAII BE 16 GA. H.M. FLUSH <br />TYPE WITH DOUBLE STUDS AT JAMBS, FRAMES ARE TO BE REINFORCED AND PREPARED FOR HARDWARE. PROVIDE 4" HEAD FOR FRAMES IN EXTERIOR CMU <br />OPENINGS WHERE APPROPRIATE TO MATCH MASONRY COURSING, <br />10, HM DOORS ARE TO BE 18 GA., FACTORY PRIMED STEEL, FLUSH TYPE WITH INSULATED WEATHER SEALED CORE; STIFFENING; HARDWARE REINFORCING; CLOSED <br />TOP & BOTTOM CHANNELS; AND HANDED FOR INDICATED SWING, DO NOT USE UNIVERSAI_ TYPE DOORS. <br />11, SOLID CORE WOOD DOORS SHALL BE PAINT GRADE BIRCH SKINS WITH SOLID STAVE CORES. <br />12. DOOR VIEWER TO BE ADVANCED SAFETY DEVICES MODEL #DS238-SLVR. <br />13. DOOR TYPE 'IF" SHALL RECEIVE A 4%20"H VISION LIFE IN A WELDED STEEL FRAME. FINISH TO MATCH DOOR. SEE DOOR REMARKS FOR GLASS TYPE: CLEAR <br />OR ONE-WAY. <br />14. DOOR TYPES "C" "F" & "G" SHALL RECEIVE ON THE HALL SIDE A 12" KICK PLATE BY BROOKLINE INDUSTRIES. FINISH BMHA 626 W/ COUNTERSUNK SCREW <br />HOLES. <br />15. DOOR "B" TO BE ELIASON, EASY -SWING P-11 PLUS (PLASTIC HONEYCOMB CORE), 103 'WHITE' FINISH WITH 904 CENTER WINDOW SET IN 103 'WHITE' <br />MOLDING, AND PAINTED HOLLOW METAL FRAME, WITH 5X18 JAMB GUARDS <br />16. GENERAL CONTRACTOR TO PROVIDE CONSTRUCTION CORES FOR ALL EXTERIOR DOORS PRIOR 10 TURN OVFR. AT TIME OF TURN OVER CONTRACTOR IS TO TURN <br />OVER TO ROSS STORE MANAGER CORE EXTRACTION KEY. <br />17, ROSS STORE MANAGER TO BE RESPONSIBLE FOR REKEYING STORE. <br />18, SAIFS FLOOR EXIT DOORS NO. 3 AND NO, 5 ARE TO BE EQUIPPED WITH THE ALARM LOCK PUSH BAR MODEL 715 DELAYED EXIT DEVICE WITH BEST 7-PIN <br />MORTISE CYLINDER AND CONCEALED INSTALLATION USING VON DUPRIN EPT-10 POWER TRANSFER HINGE AND DETECTION SYSTEM WITH TIME -DELAY BY-PASS <br />CONTROL, SEE FRAME PREP DETAILS 1 & 2 / DE1.0. (INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS). IF STORE REQUIRES HURRICANE SHUTTERS <br />IHEN DOOR #3 IS TO BE EQUIPPED WITH INSIDE/OUTSIDE KEY CONTROL IN ADDITION TO DELAYED EXIT EGRESS DEVICE. <br />c r c - - <br />19. DOOR E IS A �91 SERIES THERMACORE INSULATED STEEI SECTIONAL - - <br />0 AL DOOR BY THE OVERHEAD DOOR CORPORATION, DALLAS, TEXAS; 8 0' X 8 0; <br />STANDARD BULB -TYPE BOTTOM SEAL AND OPTIONAL HEADER SEA[- AND JAMB WEATHERSTRIPPINC; 2" TRACK; MANUAL 011LRA110N; COLOR: WHITE; WITH TWO (2) <br />INTERIOR MOUNTED SLIDE LOCKS, ONE AT EACH SIDE AT +36' AFF. INCLUDE TWO (2) HIS1 418/2 PADLOCKS. <br />20. EXIT DOOR N0. 4 IS TO BE EQUIPPED WITH THE ARROW 330 PANIC DEVICE WITH LOW HAIIFRY ALERT, BEST 7-PIN CYLINDER AND BMHA 626 FINISII, <br />21. ANY QUESTION OR PROBLEMS W/ LOCKING HARDWARE SHOULD BE DIRLCI1-1) 10: BEST LOCK CORPORATION (SEE SHEET AO.0 FOR CONTACT INFO.). <br />22. UNLESS OTHERWISE REQUIRED BY LOCAL AUTHORITY, INSTALL ACCESSIBLE TOILET ROOM SIGNING CENTERED AI 60" AFF ON THE WALL ADJACENT TO THE <br />STRIKE SIDE OF THE DOOR, MINIMUM 9"x9" WITH CONTRASTING AND RAISED PICTOGRAPH, SANS SERIF LETTERING AND GRADE 2 BRAILLE. (ROSS STANDARD <br />ACCFSSIBI F TOILET ROOM SIGNING WILL BE PROVIDED FOR g.c• INSTALLATION THROUGH ROSS CONSTR. RFPRFSFNTATIVE) ALL OTHER SIGNING REQUIRED BY ADA <br />OR LOCAL AUTHORITY, WHETHER Al IOILET ROOMS OR ELSEWHERE IN THE BUILDING, MUST BE PROVIDED AND INSTALLED BY TIFF GENERAL <br />CONTRACTOR. <br />23, DOORS NO, 6 AND 20 SHALL BE CONTROLLED BY A IRILOGY T2 LEVER DIGITAL LOCK (DL 2700 IC / 26D) BY ALARM LOCK SYSTEMS (SFF SHEET A0.0 FOR <br />CONTACT INFO). USE BEST 7-PIN CORE. <br />24, ALL EXTERIOR DOORS ARE 10 BE FULLY WEATHERSTRIPPFD INCLUDING A RAIN DRIP AND DOOR BOTTOM, HAVE ACCESSIBLE THRESHOLDS (EXCEPT DOOR 19) <br />AND CONCRETE LANDINGS (OR SIDEWALK). EXTERIOR DOORS OPENING ON TO TRAFFIC AREAS ARE TO BE PROTECTED BY PIPE BOLLARDS. <br />25. PROVIDE VON DUPRIN - MODEL 5211 ELECFRIC STRIKE WITH LOCKNETICS (SCHLAGE) 701 RD MOMENTARY WALL SWITCH (800) 950-4573. <br />26. SECURITY SHUTTERS - ANODIZED ALUMINUM SECURITY STUTTER BY QMI SECURITY SOLUTIONS, VERTICAL TRACK MOUNTED AT INTERIOR TO STOREFRONT <br />MULLIONS, LOCKING MECHANISM AND LIFTS MOUNTED AT 36" A.F.F. AT DOORS AND AT 27" A,F.F. AT WINDOWS; SLAT TYPE AL5-E; STYLE PUNCH 51; 10" <br />HOUSING MOUNTED TO STOREFRONT VERTICAL MULLIONS, CONTROL TYPE SPRING A-7-13, VERIFY WHERE REQUIRED, SUPPLIED AND INSTALLED BY ROSS LP. <br />ROOM FINISH &MATERIALS NOTES <br />COORDINATE ALL ORDERS AND DELIVERIES WITH THE LISTED VENDORS, NO SUBSTITUTIONS Will BE ALLOWED, <br />1, NEW CONCRETE MUST BE TREATED WITH THE CRE ESEAL CS2000 SPRAY APPLY SYSTEM (15 YR. WARRANTY) APPLIED IN ACCORDANCE WITH MANUFACTURERS <br />NSIRUCTIONS. THE CS2000 2-DAY SYSTEM MUST BE USED ON EXISTING SLABS. <br />2, SLABS MUST BE DESIGNED AND PREPARED TO TEST AND MAINTAIN MOISTURE VAPOR EMISSIONS AT OR BELOW 5-LBS PER 1000 SF PER 24-HRS USING THE <br />CALCIUM CHLORIDE METHOD (ILSI RESULTS SHALL BE PROVIDED TO ROSS CONSTRUCTION MANAGER), THE PROCESSING ROOM, ELECTRICAL ROOM AND OTHER <br />AREAS OF THE SLAB NOT RECEIVING FINISH TILE OR CARPET ARE TO RECEIVE A TWO COAT APPLICATION OF A PENETRATING LOW VISCOSITY EPDXY OR ACRYLIC <br />SEALER; AT EXISTING SLABS ADD A LIGHT -GRAY COLOR, SUCH AS GARLAND 122 LICHT-GRAY, 10 EPDXY FOR UNIFORM FLOOR FINISH. <br />3. NEW CONCRETE MUST BE TREATED WITH THE CRETESEAL CS2000 SPRAY APPLY SYSTEM (15 YR. WARRANTY) APPLIED IN ACCORDANCE WITH MANUFACTURERS <br />INSTRUCTIONS, THE CS2000 2-DAY SYSTEM MUST BE USED ON EXISTING SLABS. <br />r• r <br />c <br />4, SLABS MUST BE DESIGNED AND PREPARED TO TEST MOISTURE - <br />AND MAINTAIN MOhTJRE VAPOR EMISSIONS AT OR BELOW 5 LBS PER 1000 SF PER 24-IIR� USING THE r r c .a <br />CALCIUM CHLORIDE METHOD. TEST RESULTS SHALL BE PROVIDED CONSTRUCTION <br />TO ROSS ON�TRUCTION MANAGER), THE PROCESSING 'T ( ) ROOM, LLLG RICAI_ ROOM AND OTHER <br />AREAS OF THE SLAB NOT RECEIVING FINISH TILE OR CARPET ARE TO RECEIVE A TWO -COAT APPLICATION OF A PENETRATING LOW VISCOSITY EPDXY OR ACRYLIC <br />SEALER; AT EXISTING SLABS ADD A LIGHT -GRAY COLOR, SUCH AS GARLAND 122 LIGHT-CRAY, TO EPDXY FOR UNIFORM I-LOOR FINISH. <br />Proj. Mgr. <br />JU <br />Job. Capt. <br />SG <br />Drawn by <br />JT <br />Rev'd by <br />RB <br />RON BARR, A.I.A. <br />STATE OF FLORIDA <br />AR 0016160 <br />S <br />cc C <br />S = L <br />U <br />i a i <br />w <br />i D i <br />z <br />O 5 <br />Q o <br />z X c <br />5 <br />m F <br />��Wt <br />o a F <br />Z <br />1 <br />T C <br />C COPYRIGHT 2012 <br />BARR ARCHITECTURAL STUDIO <br />,f 1111, <br />Ing, <br />A <br />liu <br />a <br />t <br />Ip <br />I <br />6� RIP <br />1" <br />' <br />L <br />kia <br />`I <br />A�° <br />al <br />�I FS <br />I <br />u <br />hl <br />imM1�S <br />Revisions: <br />CADFILE No. <br />s <br />ICI <br />aE <br />j, <br />�] <br />a1„lII <br />h>R •a a <br />jj <br />Al9 <br />n ! <br />a Y 1ill <br />li 1.40 <br />a d <br />62 <br />0 <br />150 <br />C7 <br />(0 <br />C <br />CIO <br />4J <br />�= <br />N <br />C: <br />u_ <br />N <br />T <br />V <br />ai <br />a <br />W <br />' <br />a <br />d' <br />Lo <br />� <br />401 <br />C, <br />,E <br />. <br />"' <br />,C <br />as <br />uo <br />3 <br />� <br />E <br />L <br />o <br />0 <br />L <br />� <br />� <br />U <br />ACA <br />Lo <br />m <br />A- <br />U <br />a <br />N <br />U <br />L0 <br />i <br />Sheet Title <br />ROOM FINISH <br />AND DOOR <br />SCHEDULES <br />Scale: AS NOTED <br />Date: Sheet No. <br />01-31-2013 <br />Project No. <br />A6.0 <br />12-027 <br />