Laserfiche WebLink
GENERAL NOTES <br />THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOeSI,7E PRIOR TO <br />STARTING ANY WORK AND NOTIFY ENGINEER/ARCHITECT IN WRITING IMMEDIATELY FOR ANY <br />DISCREPANCIES OR THE BUILDER SHALL ACCEPT FULL RESPONSIBILITY FOR ANY ERRORS OR <br />OMISSIONS. <br />00 NOT 'SCALE THE DRAWINGS, <br />THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE MEANS AND METHODS OF <br />CONSTRUCTION AND TO PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE AND THE <br />P�OPLE AT WORK OR OTHERS DURING THE� CONSTRUCTION, <br />THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO SUPERVISE AND COORDINATE ALL THE WORK <br />OF ALL TRADES <br />THE GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF CHASES, OPENINGS, INSERTS, SLEEVES, <br />PADS, DEPRESSIONS, FINISHES AND WALL OPENING S, <br />DO NOT LOAD THE SLAB -ON -GRADE OR SUPPORTED SLAB WITH ERECTION CRANES (DR ANY ERECTION <br />ECUIP:MENT. THE SLABS HAVE NOT DESIGNED FOR CRANE LOADS AND WILL REOUIRE AN INCREASE IN <br />THICKNESS AND/OR REINFORCEMENT, OBTAIN ARCH,/ENG, APPROVAL ON PROPOSED CRANE SUPPORT <br />PLAN BEFORE COMMENCING WORK, <br />00 NOT STORE OR STACK CONSTRUCTION MATERIALS ON POURED OR ERECTED FLOORS/ROOFS IN <br />EXCESS OF 750/c OF LIVE LOAD. GENERAL CONTRACTOR WILL ENSURE THAT ALL SUB -CONTRACTORS <br />ARE INFORMED OF LOADING RESTRICTIONS, AVOID IMPACT WHEN PLACING MATERIALS ON POURED OR <br />ERECTED FLOORS OR ROOF, <br />NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED, OR OTHERWISE REDUCED IN STRENGTH <br />SUBMIT MINIMUM FOUR (4) COPIES OF SHOP DRAWINGS AS REQUIRED, ALLOW ONE WEEK FROM DATE <br />OF RECEIPT FOP, REVIEW, <br />ENGINEER ACCEPTS NO RESPONSIBILITY FOR GRADE BEAMS, SLABS, FOOTINGS, AND OTHER <br />STRUCTURAL ELEMENTS UNTIL REVIEW OF APPROVED TRUSS, CONCRETE PLANK, AND OTHER SHOP <br />[DRAWINGS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER, <br />DIMEN$ION��__k COOIjDINATION <br />DIMENSIONAL INFORMATION, PRICING, ALL DETAILS AND CONSTRUCTION SHALL BE BASED ON THE <br />ENTIRE SET OF CONTRACT DOCUMENTS, COORDINATE THE REQUIREMENTS OF ALL PROFESSIONALS, <br />USE INFORMATION FROM APPROVED SHOP DRAWINGS TO SUPPLEMENT CONTRACT DOCUMENTS WHERE <br />NECESSARY, REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO PROCEEDING. IF- A CONFLICT <br />EXISTS, THE MORE STRINGENT GOVERNS, <br />THE CONTRACTOR MUST USE STRUCTURAL DRAWINGS IN CONJUCTION WITH ARCHITECTURAL, CIVIL, <br />PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS TO COORDINATE LOCATION OF DEPRESSED <br />SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, OPENINGS, PEGLE7S, SOLT SETTINGS, SLEEVES <br />DIMENSIONS, ETC, (DRAWINGS NOT BE SCALED) DISCREPANCIES BETWEEN INFORMATION PRESENTED <br />WITHIN PROJECT SPECIFICATIONS AND WITHIN STRUCTURAL NOTES ON PLANS SHALL BE BROUGHT TO <br />THE ATTENTION OF THE ENGINEER BY THE CONTRACTOR PRIOR TO PRESENTING HIS OR HER SID� IF <br />SUCH A DISCREPANCY IS DISCOVERED SUBSEQUENT TO SIDDING.'THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR IMPLEMENTING THE OPTION SUBSEQUENTLY SELECTED BY THE ENGINEER AT NO <br />ADDITIONAL COST, CONTRACTORS SHALL BE RESPONSIBLE FOR FINAL VERIFICATION OF ALL <br />DIMENSIONS, ELEVATIONS, CLEARANCES, ETC, OF THE FRAMING SHOWN ON THE STRUCTURAL <br />DRAWINGS AGAINST INFORMATION PROVIDE[) BY MANUFACTURERS OF- SELECTED MECHANICAL <br />EQUIPMENT PRIOR TO PRECEDING WITH ANY RELATED PORTION OF WORK, ITEMS REQUIRING SUOH <br />REVIEW SHALL INCLUDE ELEVATORS iELEVATOR PITS, BEAMS ABOVE ELEVATOR DOORS, ETC.) <br />ESCALATORS, DUCTS, COOLING TOWERS, ETC, CONTRACTOR SHALL BE SOLELY RESPONSIBLE. FOR <br />ANY REMEDIAL WORK AND FOR ITS IMPACT ON THE WORK SCHEDULE RESULTING FROM FAILURE TO <br />PROVIDE EARLY NOTIFICATION OF SUCH CONFLICTS TO THE DESIGN TEAM. POTENTIAL CONFILICTS, <br />ERRORS OR OMISSIONS PRESENT WITHIN THE DRAWING'S (WHETHER WITHIN STRUCTURAL DRAWINGS <br />OR BETWEEN STRUCTURAL, ARCHITECTURAL AND M.E,P. DRAWINGS) SHALL BE IDENTIFIED BY THE <br />CONTRACTOR DURING HIS/HER EARLY REVIEW 012 THE PROJECT DOCUMENTS, SUCH CONFLICTS, <br />ERRORS OR OMISSIONS SHALL BE COMMUNICATED TO THE ARCHITECT IN WRITING PRIOR TO <br />COMMENCEMENT OF WORK, IN THE EVENT OF FAILURE TO PROVIDE SUCH A NOTICE AND SUFFICIENT <br />TIME FOR A RESPONSE, THE CONTRACTOR $HALL BECAME RESPONSIBLE FOR COST OF ALL WORK <br />OR REMEDIAL WORK RESULTING FROM SUCH CONFLICTS, ERRORS OR OMISSION, AS WELL As FOR ITS <br />IMPACT ON THE PROJECT SCHEDULE, (CONTRACTOR AGREES THAT HE WILL HOLD OWNER, <br />ARCHITECT, ENGINEER AND/OR ANY OF THEIR EMPLOYEES OR AGENTS, HARMI-ESS FROM ANY AND <br />ALL DAMAGE AND CLAIMS WHICH MAY ARISE BY A REASON OF ANY NEGLIGENCE ON THE PART OF <br />THE CONTRACTOR, OR ANY OF HIS SUBCONTRACTORS, (DR ANY MATERIAL AND EGUIPMENT SUPPLIES, <br />AND/OR ANY OF THEIR EMPLOYEES OR AGENTS, IN THE PERFORMANCE OF THIS CONTRACT� IN CASE <br />ANY ACTION IS BROUGHT AGAINST THE OWNER, OR ARCHITECT OR ENGINEER OR ANY OF THEIR <br />EMPLOYEES OR AGENTS, CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DEFENSE THEREOF, <br />TO THE FULL SATISFACTION OF LATTER PARTY, <br />WHERE CRITICAL DIMENSIONS CANNOT BE DETERMINED FROM THE PLANS, OR WHERE NEW WORK <br />ADJOINS EXISTING CONSTRUCTION, OR WHERE ONE MATERIAL ADJOIN$ A PREVIOUSLY PLACED <br />MATERIAL WITH A MORE RESTRICTIVE TOLERANCE THAN IN -PLACE MATERIAL, CONTRACTOR $HALL <br />TAKE FIELD MEASUREMENTS AS REQUIRED TO COMPLETE SHOP DRAWINGS AND INSTALLATION, <br />REPORT ANY DISCREPANCIES EXCEEDING 3% BETWEEN FIELD MEASUREMENT DIMENSIONS AND SCALED <br />DRAWING DIMENSIONS 'TO ARCHITE07 BEFORE PROCEEDING WITH WORK, DO NOT SCALE DRAWINGS� <br />USE DIM��NSIONS <br />WHERE A LINE, OF STRUCTURE, OPENING LOCATION, 09 DIMENSION IS CRITICAL AND BASED ON <br />REQUIREMENTS OF ANOTHER TRADE OR SUBCONTRACTOR, THAT SUBCONTRACTOR SHALL SUBMIT A <br />SHOP DRAWING WITH THE REQUIRED DIMENSIONAL INFORMATION UPON WHICI-I THE CONTRACTOR <br />$IHALL BASE THE LAYOUT AND CONSTRUCTION, THIS PROCEDURE Is MANDATORY FOR CURTAIN WALL <br />SYSTEMS, ARCHITECTURAL PRECAST SYSTEMS. AND ALL MECHANICAL AND ELECTRICAL OPENINGS. <br />THE ENGINEER WILL CLOUD OR OTHERWISE INDICATE REVISIONS TO THESE DOCUMENTS ONLY AFTER <br />THEY HAVE BEEN ISSUED FOR CONSTRUCTION OR FINAL PRICING, CHANGES PRIOR TO THAT DATE <br />WILL NOT BE CLOUDED, CHANGES ANID/OR REVISIONS AFTER THE CONSTRUCTION OR FINAL PRICING <br />ISSUE WILL BE CLOUDED IN AN ATTEMPT TO BRING TO THE CONTRACTOR'S ATTENTION ANY MAJOR <br />ITEMS� HOWEVER, IT SHALL BE SOLELY THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE <br />PRICING AND CONSTRUCTION OF ALL REQUIREMENTS OF THESE DOCUMENTS, INCLUDING REVISIONS <br />(FLAGGED OR UN -FLAGGED) WITH ALL OF HIS SUPPLIERS AND SUBCONTRACTOR& REVISION$ ARE <br />IDENTIFIED BY A REVISION NUMBER WITHIN A TRIANGLE, ALL REVISIONS ISSUED ON A SINGLE DATE <br />WILL BE IDENTIFIED BY 'THE SAME NUMBER, <br />CONSTRUCTION TO COMPLY WITH REQUIREMENTS OF THE GOVERNING, BUILDING CODE, AND ALL <br />OTHER APPLICABLE FEDERAL, STATE, AND LOCAL CODES, STANDARDS, REGULATIONS AND LAWS, <br />DETAILS LABELED AS "TYPICAL DETAILS" ON DRAWINGS AND DETAIL SHEETS, APPLY TO ALL <br />SITUATIONS THAT ARE SWILAR OR SAME AS THOSE SPECIFICALLY DETAILED, SUCH DETAILS APPLY <br />WHETHER OR NOT THEY ARE KEYED AT EACH LOCATION ON PLAN DRAWINGS, QUESTIONS REGARDING <br />APPLICASILITY OF DETAILS SHALL BE RESOLVED BY THE ARCHITECT OR ENGINEER, <br />CONSTRUCTION DOCUMENTS MUST GET APPROVAL FROM PERMITTING AGENCIES, THUS IT IS <br />UNDERSTOOD THIS SET OF STRUCTURAL DRAWINGS IS NOT ON FINAL FORM UNTIL IT SEARS THE <br />BUILDING DEPARTMENT PLANS REVIEW PROCESS STAMP AND SIGNATURE OF APPROVAL. <br />S OP DRAWING—SA— <br />S—T RU _CT U R &L—S- 0 Ml TMA Ll <br />SUBMIT TO THE ENGINEER FOUR ORIGINALS ONLY AFTER THEY HAVE- BEEN REVIEWED BY THE <br />CONTRACTOR, IF ADDITIONAL COPIES OF ANY MATERIAL ARE REQUIRED, PLEASE PROVIDE SUCH. <br />HOWEVER ONLY THREE COPIES WILL BE MARKED BY THE ENGNEER, <br />UNDER NO CIRCUMSTANCES WILL THE USE OF STRUCTURAL DRAWINGS PREPARED BY THIS OFFICE BE <br />PERMITTED FOR SHOP DRAWING OR BACKGROUND USE, THIS INCLUDES BOTH PHOTOGRAPHIC AND <br />ELECTRONIC REPpOoUCTiON, SHOP DRAWING$ SHALL BE PREPARED ENTIRELY BY THE VENDOR OR <br />SUBCONTRACTOR GENERATING SUCH SUBMITTAL, <br />THE USE OF ANY DRAWING PREPARED BY THIS OFFICE AS BACKGROUND INDICATES ACCEPTANCE OF <br />TERMS AND CONDITIONS BY OUR OFFICE FOR THEIR USE AND STIPULATED COMPENSATION MUST BE <br />DELIVERED TO OUR OFFICE PRIOR TO SUBMITTAL OF SHOP DRAWINGS, OTHERWISE, SHOP DRAWINGS <br />WILL BE RETURNED NON REVIEWED, <br />REVIEW OF SHOP DRAWINGS IS NOT CONDUCTED FOR DETERMINING 'THE ACCURACY AND <br />COMPLETENESS OF DETAILS OR FOR SUBST ANTI ATING FABRICATION INSTAI-LATION INSTRUCTION OR <br />PERFORMANCE OF EQUIPMENT OF SYSTEM, ALL OF WHICH $HALL REMAIN THE SOLE RESPONSIBIL17Y <br />OF THE CONTRACTOR, <br />REVIEW OF SHOP DRAWINGS DOES NOT CONSTITUTE APPROVAL OF SAFETY PRECAUTIONS, <br />CONSTRUC71ON MEANS, METHODS, SEQUENCES OR PROCEDURES, NOR DOES IT INDICATES Al:)PROVAL <br />OP ASSEMBLY OF WHICH THE ITEM IS A COMPONENT, COORDINATION OP ALL TRAcES SHALL REMAIN <br />THE SOLE RESPONSIBILITY OF THE CONTRACTOR, CONTRACTOR MUST REVIEW ALL QUANTITIES AND <br />DIMPINSIONS, <br />ALLOW ADEQUATE TIME FOR TRANSIT, AND PROCESSING BEFORE FABRICATION OUR OFFICE WILL <br />REVIEW AN AVERAGE SUBMITTAL WITHIN 15 C ALENDAR DAYS OF RECEIPT DRAWINGS RECEIVED AFTER <br />3:00 PM WILL BE STAMPED AS RECEIVED THE FOLLOWING DAY, REVIEW OF SHOP DRAWINGS IS <br />LIMITED TO TWO REVIEWS PER SUBMITTAL WITHIN THE SCOPE OF BASIC SERVICES, THAT IS ONE <br />INITIAL REVIEW AND ONE ADDITIONAL REVIEW ONCE MARKED ITEMS HAVE BEEN CORRECTED, REVIEW <br />OF ADDITIONAL SUBMITTALS WILL BE CONSIDERED ADDITIONAL SERVICES, FOR WHICH THE <br />CONTRACTOR MAY BE HELD RESPONSIBLE, THOSE ADDITIONAL SERVICES FEES WILL BE IN <br />ACCORDANCE WITH THE TERMS OF THE AGREEMENT FOR THIS PROJECT, OUR OFFICE WILL MARK <br />ONLY THREE SETS OF DRAWINGS REGARDLEE3S OF HOW MANY COPIES HAD BEEN SUBMITTED, ONI-Y <br />AFTER DRAWINGS BEAR EVIDENCE OF BEEN REVIEWED AND APPROVED BY THE CONTRACTOR. SHOP <br />DRAWINGS SUBMITTED 'TO OUR OFFICE WITHOUT CONTRACTORS APPROVAI, WILL BE RETURNED UN <br />REVIEWED. <br />SPECIALTY OR DELEGATED ENGINEERING SHOP DRAWING& BY DEFINITION A DELEGATED ENGINEER IS <br />A FLORIDA REGISTERED PROFESSIONAL ENGINEER, NOT THE ENGINEER OF RECORD, WHO SPECIALIZED <br />IN AND WHO UNDERTAKES 'THE DESIGN OF STRUCTURAL COMPONENTS OR STRUCTURAL SYSTEMS <br />INCLUDED IN A SPECIFIC SUBMITTAL PREPARED POR THIS PROJECT, <br />THE DELEGATED OR SPECIALTY ENGINEER SHALL BE AN EMPLOYEE OR OFFICER OF A FABRICATQR, <br />AN EMPLOYEE OR OFFICER OF AN ENTITY SUPPLYING COMPONENTS TO A FABRICATOR, OR AN <br />INDEPENDENT CONSULTANT RETAINED BY THE FABRICATOR OR HIS SUPPLIER, <br />SUBMITTAL AND RE -SUBMITTAL FOR CUSTOM DESIGNED, MANUFACTURED OR FABRICATED <br />LOAD -CARRYING MEMBERS, COMPONENTS OR ITEMS, SUBJECT TO FORCES OR STRESSES AND THEIR <br />CONNECTION OR ANCHORAGE REQUIRE A DELEGATED OR SPECIALTY ENGINEER, <br />THE FOLLOWING SYSTEMS AND COMPONENTS REQUIRE FABRICATION, AND ERECTION DRAWINGS <br />ALONG WITH SIGNED AND SEALED CALCULATIONS BY A DELEGATED ENGINEER: <br />- ALUMINIUM OR LIGHT GAGE STEEL, EXTERIOR WALL SYSTEMS, <br />-GLAZING AND STORE FRONT SYSTEMS, INCLUDING MULLIONS AND CONNECTIONS <br />-POST-TENSIONED CONCRETE MEMBERS <br />-PREFABRICATED WOOD TRUSSES <br />-PRECAST CONCRE�,TE COMPONENTS: WALLS, COLUMNS, JOISTS <br />-CONCRETE TILT -UP WALLS AND COMPONENTS <br />-SHORING AND RE-SHCRING DRAWINGS <br />ALL. SUBMITTALS SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT AND APPLICABLE CODES, AS WELL <br />AS THE DESIGN CRITERIA WHICH SHOULD NOT BE IN CONFLICT WITH THOSE SPECIFIED ON THE <br />CONTRACT DOCUMENTS, THE APPLICABLE B,UILDING CODE NOR THE SPECIFICATIONS, <br />IN CASE OF CONFLICT REQUEST FOR CLARIFICATION MUST BE SUBMITTED IN WRITING TO A/E, OR <br />THE MOST STRINGENT CRITERIA MUST BE USED, SUBMITTAL MOST SHOW ALL DETAILS, PLANS AND <br />NECESSARY INFORMATION FOR THE PROPER FABRICATION AND INSTALLATION OF SYSTEM OR <br />COMPONENTS, CALCULATIONS AND DRAWINGS MUST CLEARLY IDENTIFY SPECIFIC PRODUCTS UTILIZED <br />SINCE GENERIC PRODUCTS WILL NOT BE ACCEPTED, <br />ALL SHOP DRAWINGS AND CALCULATIONS MUST BEAR THE IMPRESSED SEAL, DATE AND SIGNATURE <br />OF THE DELEGATED OR SPECIALTY ENGINEER, IN CASE THAT COMPUTER PRINT-OUTS ARE SUBMITTED <br />THOSE MUST BE ACCOMPANIED WITH DESCRIPTIVE INFORMATION AS OF THE INPUT AND OUTPUT FOR <br />THEIR PROPER EVALUATION, SUCH DESCRIPTION OF COMPUTER PRINT-OUTS MUST BE SIGNED AND <br />SEALED AS WELL WITH A NOTE INDICATING FULL ACCEPTANCE AND LIABIL17Y OVER THE RESULTS OF <br />SAID COMPUTER PROGRAM, REVIEW BY OUR OPPICE OR OF SUBMITTAL S IS LIMITED TO VERIFYING <br />THAT THE SPECIFIC STRUCTURAL. SUBMITTAL HAVE BEEN FURNISHED; THAT THE STRUCTURAL <br />SUBMITTAL HAVE BEEN SIGNED AND SEALED BY THE DELEGATED ENGINEER; THAT THE SPECIFIED <br />CRITERIA$, AND DESIGN INTENT HAVE BEEN FOLLOWED AND UNDERSTOOD BY THE DELEGATED <br />ENGINEER� AND THAT THE CONFIGURATION SET FORTH IN THE STRUCTURAL SUBMITTAL IS <br />CONSISTENT WITH THE CONTRACT DOCUMENTS, <br />NO DETAIL CHECK OF DIMENSIONS OR QUANTITIES WILL BE MADE SINCE THIS TO BE PERFORMED BY <br />THE GENERAL CONTRACTOR, <br />SUBMITTALS NOT MEETING THE ABOVE CRITERIA WILL BE RETURNED NON REVIEWED, <br />CON9FLET-9 <br />A CERTIFIED TESTING AGENCY $HALL PERFORM INDUSTRY -STANDARD TESTING INCLUDING SLUMP <br />TESTS AND CYLINDER BREAKS TO ENSURE CONFORMANCE WITH PLANS AND spFcIFICATIONS, SUBMIT <br />REPORTS TO ARCHITECT AND E.NGINEER, <br />REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO A.S,T.M, A615 GRADE 60 �Py z 60 <br />KSI) AND CONCRETE STRENGTH $HALL BE 3000 PSI AT 28 DAYS. <br />WELDED FIRE FABRIC SHALL BE W/6x6 W2.OxW2,0 WWF CONFORMING WITH A,S,I-,M. Ai86. <br />TIE WIRES SHALL CONFORM WITH A,S.TM, A82 <br />REINFORCING INSTALLATION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE RECENT Aci <br />CODE� <br />REBARS IN BEAMS, COLUMNS AND SLABS SHALL BE FULLY SECURED PRIOR TO FINAL POUR, <br />REINPORCING STEEL SHALL BE CLEAN AND FREE FROM FOREIGN DEBRIS, NONMETALLIC COATINGS, THE <br />REINPORCEMENT STEEL SHALL ALSO BE FREE FROM RESIDUES SUCH AS OIL, MUD, DIRT, SCALE ANY <br />PITTING AND NICKS THAT IS MORE THAN 2% OF THE TOTAL CROSS SECTIONAL AREA OF ANY RESAR. <br />REINFORCING STIFEL SHALL HAVE THE FOLLOWING <br />MINIMUM CCVER� <br />ANY CONCRETE POUR AGAINST EARTH 3" <br />ANY FOOTINGS TOP, L907TOM AND SIDES 3 <br />SEAMS PRIMARY REINFORCEMENT AND STIRRUPS 1,5" <br />COLUMNS PRIMARY REINP., TIES AND SPIRALS 1.5.1 <br />SLAB ON GRADE BOTTOM COVER 2" <br />SLABS 1. 5 " <br />VERTICAL BARS IN CONCRETE COLUMNS MUST BE CONTINUOUS, REBARS SHALL BE LAPPED <br />EQUIVALENT TO 48 DIA, OF LARGER SIZE LAPPING BARS OR MIN, 30" OR OTHERWISE AS NOTED. <br />LAPPING BARS MUST BE SECURED WITH MINIMUM WITH 3 TWIST TIES. <br />VERTICAL COLUMN REINFORCEMENT MUST LAP WITH HORIZONTAL REBARS IN BEAMS A LENGHT <br />EQUIVALENT 15 BAR DIA. OF LARGER SIZE LAPPING BARS OR MIN. 12" OR OTHERWISE AS NOTED, <br />LAPPING BAR$ MUST BE SECURED WITH MIN, (21 TWIST TIES, <br />VERTICAL COLUMN REINFORCEMENT MUST LAP WITH HORIZONTAL REBARS IN FOOTER AND SLAB A <br />LENGTH EQUIVALENT 16 BAR Dik OF LARGER SIZE LAPPING BARS OR MIN. 12" OR OTHERWISE As <br />NOTED, LAPPING BARS MUST BE SECURED WITH MIN. (2) TWIST TIES, <br />CORNERS BAR$ IN CONCRETE BEAMS MUST LAP WITH MAIN BARS IN BEAMS A LENGTH EQUIVALENT <br />TO 42 BAR DIA. OF LARGER SIZE LAPPING BARS OR MIN. 36" OR OTHERWISE AS NOTED, LAPPING <br />BARS MUST BE SECURED WITH MIN. (4) TWIST TIES, <br />CORNERS BARS IN CONCRETE FOOTERS MUST LAP WITH ALL MAIN F007ER REBARS A LENGTH <br />EQUIVALENT TO 42 BAR DIA, OF LARGER SIZE LAPPING BARS OR MIN, 36" OR OTHERWISE AS NOTED, <br />LAPPING BARS MUST BE SECURED WITH MIN� (4) TWIST TIES, <br />CONTRACTOR IS RESPONSIBLE FOR THE ADEQUACY OF FORMS AND SHORING AND FOR SAFE <br />PRACTICE IN THEIR USE AND REMOVAL. CONTRACTOR TO MAINTAIN FLOORS 100% SHORED. <br />CONTRACTOR SHALL ERECT FORM WORK IN STRICT COMPLIANCE WITH ACI 347, PROVIDE CHAMPERS <br />AT ALL CORNERS IN CONCRETE MEMBERS EXPOSED TO VIEW, FORM WORK TO REMAIN IN PLACE <br />UNTIL CONCRETE HAS ATTAINED ENOUGH STRENGTH 70 SUPPORT ALL DEAD LOADS PLUS A MINIMUM <br />OF 50 P.S,F, OF ADDITIONAL CONSTRUCTION LOAD, <br />Fp_uNDAT ON N9TE_$ <br />CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION, <br />DO NOT SCALE THE DRAWINGS, GO BY 0IMENSIONS ONLY, <br />A CERTIFIED TESTING AQENCY $HALL PERFORM INDUSTRY -STANDARD SOIL DEN11.51TY TESTS To <br />ENSURE CON50RMANCE WITH GEOTECHNICAL SOIL REPORT, SUBMIT REPORTS 'TO ARCHITECT AND <br />ENGINEER, <br />THERE $HALL BE A 12 HOUR TIME DELAY FOR IMPOSING A LOAD ON A SLAB AFTER CONCRETE <br />PLACEMENT <br />FOUNDATION DESIGN IS BASED ON 2500 PSF NET ALLOWABLE SOIL BEARING CAPACITY� <br />ALL REINFORCING STEEL SHALL BE GRADE 60, AND CONCRETE STRENGTH SHALL BE 3000 PSI AT 28 <br />DAYS, <br />SPLICES IN REINFORCING BARS SHALL NOT BE LESS THiAN 36 BAR DIAMETERS AND REINFORCING <br />SHALL BE CONTINUOUS AROUND ALL CORNERS AND CHANGES IN DIRECTION, CONTINUITY SHALL BE <br />PROVIDED AT CORNERS OR CHANGES IN DIRECTION BY BENDING THE LONGITUDINAL STEEL AROUND <br />THE CORNER 48 BAR DIAMETERS OR BY ADDING MATCHING REINFORCING STEEL WHICH $HALL EXTEND <br />48 BAR DIAMETERS FROM EACH CORNER OR CHANGE IN DIRECTION, <br />COLUMN AND WALL CENTERLINES SHALL COINCIDE WITH FOOTING CENTERLINES UNLESS OTHERWISE <br />NOTED, <br />SEE FOUNDATION PLAN FOR TOP ELEVATION OF ALL ISOLATED COLUMN FOOTINGS AND PADS <br />THE SOIL UNDER ALL FOOTINGS AND GROUND SLABS SHALL BE TREATED WITH AN APPROVED <br />PRE -CONSTRUCTION TERMITICIDE TREATMENT WITH A CERTIFICATE OF COMPLIANCE ISSUED TO THE <br />BUILDING DEPARTMENT PER FBC 1816 AND 2326.5, <br />REINFOR ED UNIT <br />C f.-MASONRY NOTES <br />THE REINFORCED UNIT MASONRY DESIGN FOR 'THIS STRUCTURE IS BASED ON RATIONAL ANALYSIS PER <br />F,B,C, SECTION 2118, <br />5,6�C, 2122.1 STATES THAT THE PROVISIONS O:F ACI 530-08/ASCE 5-10, BUILDING CODE REQUIREMENTS <br />FOR MASONRY STRUCTURES, AND THE COMMENTARY ON BUILDING CODE REQUIREMENTS FOR <br />MASONRY STRUCTURES, ARE HEREBY ADOPTED AS A MINIMUM: HOWEVER, THE REOUIREMENT OF THE <br />STANDARD SHALL NOT SUPERCEDE THE SPECIFIC REQUIREMENTS OF THIS CHAPTER, <br />REINFORCED UNIT MASONRY SHALL BE STELL REINFORCED SOLID UNIT MASONRY OR STEEL <br />REINFORCED GROUTED HOLLOW UNIT MASONRY. THE DESIGN OF BUILDINGS AND STRUCTURES Or: <br />REINFORCED UNIT MASONRY $HALL BE BY PROFESSIONAL ENGINEER OR REGISTRED ARCHITECH, <br />MASONRY UNIT $HALL CONFORM TO A,S,T,M. C90-90 AND SHALL HAV�- A MINIMUM PRISM STRENGTH <br />OF 1500 PSI IN 28 DAYS IN ACCORDANCE WITH A.S,T,M,, E-447�84. UNITS SHALL BE A MINIMUM OF- 48% <br />SOLID, <br />USE TYPE "S" MORTER IN ACCORDANCE WITH A,S,T.M, C-270,92, MASONRY UNITS SHALL HAVE 3/8 <br />FULL BEDDING, MCRTER PROTRUDING INTO CELL CAVITIES, THAI' ARE REINFORCED AND GROUTED, <br />SHALL BE REMOVED, ALLOW MIN. OF 24 HRS FOR MORTER TO CURE BEFORE PLACING GROUT. <br />GROUT TO BE USED IN FILLED CELLS SHALL BE OF PEA ROCK PUMP MIX WITH A MIN, COMPRESSiVE <br />STRENGTH OF 3000 PSI IN 28 DAYS IN ACCORDANCE WITH F3,0, 2122.6.5 THE SLUMP SHALL BE 9" (;1) <br />AND PLACE IN ACCORDANCE WITH P,B,C, 2122.6.,9.3. <br />GROUTED CELLS WITH REINFORCING SHALL HAVE A MINIMUM IF (1) # 6 VERTICAL AT EACH CORNER, <br />EACH SIDE OF WALL OPENINGS, AND MAXIMUM OF 4'-0" THEREAFTER, <br />TIE BEAM AND FILLED CELLS SHALL BE PLACED IN SEPARATE LIFTS AND CONSOLIDATED As REQUIRED <br />TO COMPLETELY FILL EACH CELL, CLEAN OUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF <br />ALL PILL�D CELLS FOR INSPECTION, <br />REINFORCING BARS SHALL BE NEW BILLET STEEL PER A,S,T,M, A615-94, GRADE 60, LAP REINFORCING <br />AS NOTED ON PLANS, <br />CONCRETE MASONRY BLOCKS SHALL BE INSTALLED WITH MASONRY JOINT REINF-ORCEMENT AT OTHER <br />COURSE. REINFORCEMENT SHALL BE CONTINUOUS WITH (2) BLOCK WIDTH LAPSE AT ENDS AND SHALL <br />BE INSERTED INTO CELLS OR TIE COLUMNS MIN, 4" <br />THE MINIMUM SIZE OF HORIZONTAL JOINT REINFORCEMENT SHALL BE GAUGE 9 "LADDER" TYPE <br />0EINFORCEMIENT. <br />STANDING SEAM ROOFING NOTES: <br />ALL AREAS WHERE MASTIC TO BE APPLIED SHOULD BE WIPED CLEAN WITH A MILD DETERGANT OR <br />AN ALL PURPOSE CLEANER BEFORE MASTIC APPLICATION, <br />ALL EXPOSED FASTENERS SHOULD PENETRATE THE SEALANT FOR THE MOST WEATHER TIGHT <br />CONNECTION IN ROOF AND WALLS WHERE APPLICABLE <br />ALL SHEET METAL ROOF PANELS SHALL HAVE STRUCTURAL QUALITY ASTM A-792, WITH A MIN, <br />COATING THICKNESS AS PIE�R AZ-55 DESIGNATION, AND WITH MIN. Pyz60 ks! <br />ALL SCREWS TO BE HEX HEAD, SELF DRILLING, NON CORROSIVE <br />ALL ROOF PANEL SIDELAPS AND ENDLAPS SHALL HAVE A CONTINCUS STRIP OF MASTIC SEALER <br />STRUCTURAL STEEL NOTE <br />STELL WORK SHALL CONFORM TO THE A.I.S.C, SPECIFICATIONS FOR THE DESIGN, FABRICATION AND <br />ERECTION OF STRUCTURAL STEEL BUILDINGS LATEST EDITION. <br />STEEL TUBING SHALL CONFORM TO kS.T.M. A500 GRADE S. <br />STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL BE A,S.T,M, GRADE A�572 Py - 50 KSI, ALL OTHER <br />,SHAPES SHALL BE A.S,T,M, A36, UNLESS NOTED OTHERWISE. <br />BRACE AND MAINTAIN ALL STEEL IN ALIGNMENT UNTIL OTHER PARTS OF CONSTRUCTION NECESSARY <br />FOR PERMANENT SUPPORT ARE COMPLETED, CPNTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING <br />TEMPORARY SHORING AS REQUIRED FOR THE STABILITY OF THE STEEL FRAME UNTIL ALL <br />STRUCTURAL ELEMENTS HAVE BEEN COMPLETED AND BUILDING IS ENCLOSED, <br />ALL W9LDINGS SHALL CONFORM TO tHE REQUIREMENTS OF THE STANDARD CODE FOR WELDING IN <br />BUILDING CONSTRUCTION OF THE AMERICAN WELDING SOCIETY, WELDING ELECTRODES SHALL. BE <br />E70XX- LOW HYDROGENE FOR SHIELD AND METAL ARC WELDING. <br />SHOP WELDING AND FIELD WELDS SHALL BE PERFORMED BY CERTIFIED WELDERS ONL,Y, <br />PRESSURE TREATED WO!QD NOTE, <br />ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED OR SEPARATED WITH (2) <br />LAYERS OF 30 LB. BUILDING PAPER. THE USE OFF CCA PRESSURE TREATED LUMBER Is PROHIBITED. <br />FOR INTERIOR APPLICATIONS (NOT EXPOSED TO WEATHER) PROVIDE SODIUM BORATE (SBX) TREATED <br />LUMBER, FOR EXTERIOR USE PROVIDE COPPER AZOLE (CA] OR AKALINE COPPER QUATERNARY (ACQ) <br />LUMBER, FASTENERS AND CONNECTORS ACCEPTABLE FOR USE WITH PRESSURE TREATED LUMBER <br />SHALL BE HOT DIPPED GALVANIZED, HOT DIPPED GALVANIZED CONNECTORS SHALL MEET ASTM A653, <br />CLASS G185 STANDARDS, HOT DIPPED GALVANIZED FASTENERS SHALL MEET ASTM A153 STANDARDS, <br />FASTENER$ USED TOGETHER SHALL BE SAME TYPE (E,G, HOT DIPPED NAILS WITH HOT DIPPED JOIST <br />HANGERS), TYPE 304 AND 316 STAINLESS STEEL PRODUCTS ARE REQUIRED FOR MAXIMUM <br />CORROSION RESISTANCE, <br />MECHANICAL FASTENER NOTES <br />EXPANSION ANCHORS SHALL BE "POWER STUD" BY RAW[. OR "TRU-BOLT" BY ITW RAMSET/REDHEAD <br />OR ENGINEER APPROVED EQUAL, <br />ADHESIVE ANCHORS SHALL BE "POWER"EPOON" BY ITW RAMSET/REDHEAD OR ENGINEER APPROVED <br />OR EQUAL. <br />MASONRY SCREWS"TAPCON " BY ITW RAMSET/REDII OR ENGINEER APPROVED OR EQUAL <br />POWER ACTUATED FASTENERS (PAFI RAMSET/REDHEAD , HILTI <br />aim" <br />BOLTS SHALL CON70RM TO ASTIM STANDARD A325, <br />ALL BOLT HOLES SHALL BE STANDARD SIZE VVITH 1/16 INCH MAXIMUM TOLERANCE. <br />BOLT'S TO BE HOT DIPPED GALVANIZED OR ZINC COATED, <br />BOLTS TO HAVE WASHERS ON BOTH ENDS, <br />WASHERS TO BE HOT DIPPED GALVANIZED OR ZINC COATED. <br />REINFORCING STEEL: <br />REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 GRADE 60 (Fy , 60KSII. <br />WELDED WIRE PABRIC $HALL BE 6"x6"-#1Qx#10 CONPORMING WITH ASTV A185. <br />TIE -WIRES $HALL CONFORM WITH ASTM A82. <br />REINFORCING INSTALLATION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE RECENT ACI <br />CODE, <br />REEARS IN BEAMS, COLUMNS. AND SLABS SHALL BE FULLY SECURED PRIOR To FINAL POUR, <br />REINFORCING STEEL SHALL BE CLEAN AND FREE FROM FOREIGN DEBRIS, NONMETALLIC COATINGS. <br />THE REINFORCEMENT STEEL $HALL ALSO BE FREE FROM RESIDUES SUCH AS OIL. MUD, DIRT, SCALE <br />ANY PITTING AND NICKS THAT IS MORE THAN 2% OF THE TOTAL CROSS -SECTIONAL AREA OF ANY <br />REBAR, <br />REINFORCING STEEL. SHALL HAVE THE FOLLOWING MINIMUM COVER: <br />ANY CONCRETE POURED AGAINST' EARTH 10" <br />ALL FOOTINGS TOP, BOTTOM AND SIDES 3,0" <br />BEAMS PRIMARY REINFORCEMENT AND STIRRUPS <br />TOP AND BOTTOM SIDES 1,15" <br />SLAF3-ON-GRADE BOTTOM COVER SLABS 2.0" <br />CQI_UMNS PRIMARY REINFORCEMENT, TIES AND SPIRALS 1,5" <br />VERTICAL COLUMN REINFORCEMENT MUST LAP WITH HORIZONTAL REBARS IN BEAMS A LENGTH <br />EQUIVALENT� TO 15 BAR DIAMETER OF LARGER SIZE LAPPING BARS OR MINIMUM 12 INCHES OR <br />OTHERWISE AS NOTED, LAPPING BAR$ MUST BE SECURED WITH MINIMUM 2 TWIST TIES. <br />VERTICAL COLUMN REINFORCEMENT MUST LAP WITH HORIZONTAL REBARS IN FOC)TER AND SLAB A <br />LENGTH EQUIVALENT TO 16 BAR DIAMETER OF LARGER SIZE LAPPING BAR$ OR MINIMUM 12 INCHES OR <br />OTHERWISE AS NOTED. LAPPING BAR$ MUST BE SECURED BY MINIMUM 2 TWIST TIES. <br />CORNER BARS IN CONCRETE BEAMS MUST LAP WITH MAIN BARS IN BEAMS A LENGTH EQUIVALENT '70 <br />42 BAR DIAMETER OF LARGER SIZE BARS OR MINIMUM 36 INCHES OR OTHERWISE AS NOTED. <br />LAPPING BARS MUST BE SECURED WITH MINIMUM 4 TWIST TIES, <br />CORNER BARS IN CONCRETE POOTERS MUST LAP WITH ALL MAIN FOOTER REBARS A LENGTH <br />EQUIVALENT TO 42 BAR DIAMETER OF LARGER SIZE BARS OR MINIMUM 36 INCHES OR OTHERWISE AS <br />NOTED, LAPPING BARS SHALL BE SECURED WITH MINIMUM 4 TWIST TIES, <br />WELDING: <br />WELDING WORK SHALL BE COMPLETED IN <br />ACCORDANCE WITH THE RECENT AWI CODE, <br />WELDS SHALL BE WITH E70XX ELECTRODES. <br />WELDING SHALL BE COMPLETED AND CERTIFIED BY A LICENSED AND APPROVED WELDER. <br />ST9EL 1018-T -NOTES <br />A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD <br />INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECIFICATIONS, SUBMIT REPORTS TO <br />ARCHITECT AND ENGINEER, <br />ALL DESIGN, FABRICATION AND ERECTION OF S�TEEL JOISTS AND BRIDGING SHALL BE IN STRICT <br />ACCORDANCE WITH THE CURRENT SPECIFICATIONS OF STEEL JOIST INSTITUDE AND REOOMMFNDED <br />CODE OF STANDARD PRACTICE, <br />THE ENDS OF ALL BRIDGING LINES TERMINATING AT WALLS OR BEAMS SHALL BE ANCHORED To <br />THE WALL OR BEAM. <br />ALL STEEL JOIST ARE TO BE CAMBERED AS SPECIFIED BY S,Jl <br />PROVIDE BOTTOM AND/OR TOP CHORD EXTENSIONS AS SHOWN ON DRAWINGS. <br />UNLESS NOTED OTHERWISE, MIN, JOIST BEARING SHALL BE 2 1/2" FOR K-SERIES JOIST, 4" FOR LH, <br />DLH AND SLH 16-18, AND 6" POP SLH 19-25 ON A STEEL MEMBER OR EMBEDDED PLATE, <br />BRIDGING $HALL BE FURNISHED AND INSTALLED TO MEET THE SIZE AND SPACING REQUIREMENTS <br />OF THE S,J,I, STANDARD SPECIFIATIONS FOR OPEN WEB STEEL JOISTS. ALL BRIDGING AND <br />BRIDGING ANCHORS SHALL BE COMPLETELY INSTALLED BEFORE CONSTUCTION LOADS ARE PLACE <br />ON THE JOISTS. ALL JOIST 40'-0" OR LONGER REQUIRE A ROW OF BOLTED BRIDGING TO BE <br />IMPLACE BEFORE SLAKENING OF HOISTING LINES, OTHER JOISTS REQUIRE SIMILAR BRIDGING <br />(CONSULT LATES S,J,I, SPECIFICATIONS) <br />CONTRACTOR TO FURNISH HAR JOIST CERTIr-ICATIONS SIGNED AND SEALED BY AN ENGINEER <br />REGISTRED IN THE STATE OF FLORIDA, <br />FOR NET UPLIFTS SEE NET UPLIFT PLAN, PROVIDE UPLIFT BRIDGING. <br />ALL ITEMS SQSPENDE�D FROM JOIST-S, (1,E,, CAT WALKS, SALCONIE, OPERABLE PARTITIONS, ETC,) <br />SHALL BE INSTALLED AFTER DEAD LOAD HAS BEEN APPLIED. <br />ANY STEEL JOIST WITHIN A 4'.0" DISTANCE FROM A PARALLEL SUPPORT SHALL BE FABRICATED IN <br />SUCH A WAY THAT CAMBER OF THE JOIST NOT CAUSE A PROBLEM INSTALLING 'THE METAL DECK, <br />TIE BEAM Rg!NF R(-,ING t4gM <br />TIE COLUMN REINFORCING BAR SPLICES SHALL BE LAPPED 30" MINIMUM, <br />VERTICAL REINFORCING BARS SHALL BE PLACED IN CONCRETE FILLED CELLS AND SHALL EXTEND <br />INTO THE FOOTINGS AND INTO THE BEAM, ALL SUCH BARS SHALL BE CONTINUOUS FROM FOOTING <br />TO TIE BEAM, AND SHALL TERMINATE AT EACH END WITH A STANDARD ACI HOOK, <br />SPLICES IN TIP BEAM REINFORCING STEEL ON STRAIGHT RUNS SHALL BE PROVIDED <br />BY LAPPING MINIMUM 30". <br />SPLICES IN TIE BFAM REINFORCING STEEL AROUND CORNERS SHALL BE PROVIDED <br />BY BENDING TWO BARS, ONE OUTSIDE TOP AND ONE OUTSIDE BOTTOM AROUND CORNER 30" <br />MINIMUM, OR BY ADDING TWO 45 BARS, ONE OUTSIDE TOP AND ONE OUTSIDE BOTTOM WHICH <br />EXTENDS 30" EACH WAY FROM CORNER, <br />TIE SEAMS $HALL HAVE (4) 0 3 TIES AT 12 INCHES O,C, AT CORNERS AND AT EACH SEND AND <br />AT 36 INCHES 0,0, ELSEWHERE, PER F.6,C. 212t2.3-2, <br />LIGHTGAGE M 'TAL-ERAMM <br />A CERTIFIED TESTING AGENCY $HALL BE ENGAGED TO PERFCRM INDUSTRY STANDARD <br />INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECIFICATIONS. SUBMIT <br />REPORTS TO ARCHITECT AND ENGINEER OF RECORD. <br />CONNECT STEEL STUDS AND TRACKS TO A36 STEEL OR CONCRETE WITH (2) POWDER <br />ACTUATED FASTENERS (PAF) AT EACH STUD AND CONNECT STEEL STUDS AND TRACKS <br />TO EACH OTHERS WITH (2) 48-'18 SCREWS AT EACH STUD (TYPICAL UNLESS NOTED <br />OTHERWISE) SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND EXTEENDS OF <br />STEEL STUD WORK, <br />NOTE: "POWDER ACTUATED FASTENERS P0:1 REFERS TO OA45 DIA. SHANK DOMED -HEAD, <br />LOW VELOCITY POWDER ACTUATED FASTENERS AS MANUFACTURED BY POWERS RAWL <br />OR APPROVED EQUAL WITH MINIMUM CAPACITIES AS POLLOWS� <br />IN 3000 PSI CONCRETE: 1 X" PENETRATION <br />186# PULLOUT & 225# SHEAR <br />IN A30 STEELi A" MATERIAL - <br />430# PULL�UT & 660# SHEAR <br />(PIN MUST BE FULLY PENETRATED THE MATERIAL BY <br />Y4'* MINIMUM) <br />STELL STUDS SHALL MEET FOLLOWING DESIGN <br />CRITERIA; GALV 0-20 ASTM A525, MINIMUM <br />YIELD STRESS SHALL BE 60,000 PSI FOR 129a, 14ga, <br />16ga AND 33000 PSI FOR 18ga & 20ga <br />NO STRUCTURAL MEMBER SHALL 85 CUT, NOTOHED, OR OTHERWISE <br />REDUCED IN STRENGTH BEYOND THE SCOPE OF THIS PLAN WITHOUT <br />CONSUL-TING ENGINEER OF RECORD, <br />REPORT ANY 1316CREPENCIE3 TO ENGINEER IMM901ATELY <br />CENTER OF NEW STEEL COLUMN - CENTER OF NEW PAD FOOTING <br />ECCENTRICITY 18 NOT ALLOWED U.O.N. <br />ALL FIELD CONDITIONS SIHALL BE VERIFIED BY THE CONTRACTOR <br />PRIOR TO COMMENCING THE CONSTRUCTION <br />ADEOUATE VERTICAL AND HORIZONTAL SHORING $HALL BE <br />PROVIDED TO SAFELY SUPPORT ALL LOADS DURING <br />INSTALLATION <br />Dg-SIGN CRITERIA <br />ALL WORK $HALL COMPLY WITH THE FLORIDA BUILDING CODE 2010 <br />EDITION ALONG WITH ALL APPLICABLE STATE AND LOCAL CODES, <br />ORDINANCES AND REGULATIONS <br />APPLICABLE BUILDING & DESIGN CODES: <br />1) FLORIDA BUILDING CODE 201Q EDITION <br />2) ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL <br />CONCRETE, THEE LATEST EDITION <br />3) CRSI MANUAL OF STANDARD PRACTICE, THE LATEST EDITION <br />41 STRUCTURAL WELDED WIRE REINFORCEMENT OF STANDARD <br />PRACTICE, WIRE REINFORCEMENT INSTITUTE <br />5) ACI 530/ASCE 5 BUILDING CODE RECUIREMENTS FOR <br />MASONRY STRUCTURES, THE LATEST EDITION <br />DESIGN LOADS: <br />1) WIND DESIGN LOADS; <br />WIND LOADING SHALL COMPLY TO ASCE 7.10 <br />WIND VELOCITY 14 0 M P H <br />EXPOSURE CATEGORY C <br />RISK CATEGORY 11 <br />INTERNAL PRESSURE COEFFICIENT 0,18 <br />Kd - 0,85 <br />MEAN ROOF HEIGHT 20'-0" <br />NET UPLIFTS SHOWN HEREIN ARE BASED ON (GROSS UPLIFT) <br />PER ASCE 7.10 ASD DESIGN (O,GW� NO FURTHER REDUCTION <br />ALLOWED), COMPONENTS & CLADDING ZONES 1, 2 AND 1 <br />ZONE 1 ........... ............... ........ ... I - 28,0 PSF <br />ZONE 2, � .......... .... .. .............. ....... � - 46�O PSF <br />ZONE3, _ ............. ......... ...... ...................... - 69,0 PSF <br />a - END ZONE DISTANCE .......................... - - 8'� C " <br />a <br />a -END ZONE DISTANCE <br />ROOF ZONES <br />THE PRESSURES PROVIDED IN THE TABLE <br />ARE INFORMATiON <br />PURPOSES ONLY, IT IS APPLICABLE ONLY <br />FOR GENERAL <br />CONDITIONS AND DOES NOT COVER ANY <br />SUPPORT BUILDING, <br />REFER TO BUILDING CODE FOR SPECIFIC <br />CONDITIONS AND <br />REFER TO WINDOW/DOOR SCHEDULES FOR OPENING PRESSURES <br />2) ROOF DESIGN LOADS: <br />ROOF LIVE LOAD <br />30 PSF <br />ROOF DEAD LOAD <br />30 PSF <br />ROOF DEAD LOAD FOR UPLIFT DESIGN <br />0 PSF <br />SLAB -ON -GRADE LIVE LOAD <br />100 PSF <br />TO THE BEST CP ENGINEER'S KNOWLEDGE. <br />THE STRUCTURAL <br />PLANS AND SPECIFICATIONS HAVE BEEN <br />DESIGNED IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODE 2010 <br />EDITION <br />TAYLAN KA'LKAN, P.E. <br />ENGINEERING PLUS <br />FL. PZ # 67349 & C.A. # 26538 <br />19528 SEDGEFIELD TERRACE <br />BOCA RATON, FL 33498 <br />(561) 756 4106 (561) 479 3743 fax <br />Proj Mgr: <br />AS <br />Job Capt: <br />AB <br />Drawn by: <br />AB RON BARR, AIA <br />Rev'ci by; STATE OF FLORIDA <br />RB AR 00 16160 <br />6 W l- <br />z <br />LLJ <br />E <br />E� <br />aw <br />U. Lu <br />k § g , 0 <br />ge r:z F_ W <br />J�j <br />1v PIN <br />W <br />M Fo- 2 2 <br />Z Z <br />u W-0 00 <br />z6— 9 <br />m mInzv <br />z <br />.11111 FUM >_ U. 6 <br />0 <br />�011!_ - m 0 0 d <br />W P L) z W § W <br />(9 Feopv)�6w-q- <br />F_ F- W <br />0 0 <br />Is <br />0 COPYRIC-?'HT 2012 <br />BARR ARCHITECTURAL STUDIO <br />L <br />i1c <br />IC <br />JL 1% <br />qf Ah <br />Q) <br />N <br />U- <br />iz <br />0 <br />E <br />(D <br />ft <br />Sheet TItIe: <br />or' ME N T Rl F <br />FEAU,rURE <br />Irm OFFMA M I N G <br />Scale: <br />Date: Sheet No: <br />2/5/2013 1 <br />Project. No.: owl <br />