Laserfiche WebLink
0__ <br />6 1/8" <br />1 1/4" 3 5/8" 1 1/4" <br />TYP. <br />3 5/8" <br />2 LAY[ <br />TYPE' <br />.-. <br />MAX 1/4" SPACE <br />BETWEEN BOTTOM OF <br />GYP BD & FLOOR. <br />PROVIDE SEALANT IN <br />SPACE (TYP BOTH SIDES) <br />2 HOUR FIRE/ SMOKE PARTITION - PER UL #U419 <br />6 1/8" TYPICAL WALL THICKNESS - STC RATING 50 <br />10" BLOWNI INSULATION <br />3 5/8" <br />ADD 7/8" MET. HAT <br />CHANNELS AT 24" O.C. <br />5/8" TYPE "C" GYP. BD. - <br />EXIST. 5/8" TYPE "X" GYP BD. ON 3 <br />5/8" METAL STUDS (1 HR WALL) <br />GA # WP1200 <br />MAX 1/4" SPACE BETWEEN <br />BOTTOM OF GYP. BD. & FLOOR. <br />PROVIDE SEALANT IN SPACE (TYP. <br />BOTH SIDES) AS PER UL U419. <br />EXISTING ROOF <br />ASSEMBLY <br />1" AIR SPACE <br />BLDG. WRAP <br />VAPOR BARRIER <br />5/8" SHEATHING <br />5/8" TYPE "X" GYP. BD. <br />v1TL. STUD <br />: RS <br />X" GYP. BD. TYP. <br />EXISTING 2 HR RATED <br />WALL ASSEMBLY - PATCH <br />& REPAIR PER UL. 419 <br />WOOD TRUSSES <br />2X WOOD BLOCKING <br />EXISTING 1 HR RATED <br />EID ASSEMBLY <br />3-5/8" METAL CHANNEL <br />BASE - <br />REFER TO FINISH PLAN <br />PARTITION TYPES 01 <br />3" = 1'-0" <br />EXISTING TWO LAYERS TYPE <br />"X" GYP BD. OF HAZARDOUS <br />AREAS <br />ADD ONE LAYER 5/8" TYPE "C" GYP. BD. <br />TAPE & SEAL JOINTS (TYP.) <br />REMOVE 6" OF GYP, BD. ONE SIDE, <br />INSERT IMPALING CLIPS, INSERT <br />THERMAFIBRER SAFING, REPLACE GYP. <br />BD., TAPE & FINISH. <br />BATT INSULATION PER UL I J419 <br />METAL CHANNEL <br />BASE - REFER TO FINISH PLAN <br />A ADDED TYPE "X" GYP. BD. EACH SIDE. <br />B HEAT DISSIPATION OF THE METAL TRACK ITSELF. <br />C THE GYPSUM LAYERS OF THE ONE HOUR WALLS PROVIDE ADDITIONAL PROTECTION. <br />D THE AREA OF EXPOSURE IS A SMALL PERCENTAGE OF THE WHOLE AREA, THEREFORE <br />ACTUAL TEMPERATURE RISE WOULD BE LESS. <br />E SAFING ADDED FOR CONTINUITY OF CEILING MEMBRANE <br />1 HOUR FIRE/ SMOKE PARTITION - PER UL #U419 <br />4 7/8" TYPICAL WALL THICKNESS - STC RATING 45 <br />■ <br />studio+ <br />California I Florida I Nevada <br />2211 E. 7TH Avenue, Tampa, Florida 33605 <br />P:239.357.4983 AA26002373 <br />Peninsula Engineering, INC. <br />MEP&FP <br />2016 Alden Road Orlando, FL 32803 <br />P: 407.246.1688 <br />F: 407.246.1664 <br />LBA INTERIORS <br />INTERIOR DESIGNER <br />5650 DTC PARKWAY, SUITE 100 <br />ENGLEWOOD, CO. 80111 <br />P:303.773.0436 <br />F:303.773.0053 <br />REVISIONS: <br />1 07/29/2016 JAHCACOMMENTS <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 <br />�Q <br />ARSI 53' <br />I V /1i1T _ 0 `- T 1116 <br />FPJ T TITLE: <br />Y RHILLS HEALTH & &AB CENTER <br />SKILLED NURSING -10 BED <br />CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL. 33540 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />PARTITION TYPES <br />C-',Users\LevvN\Documents12016.04.20 - CENTRAL - ADVENTIST - ZEPHYRHILLS HEALTH AND REHAB CENTER LevvN.rvt <br />PARTITION TYPES 2 if A5ml 1 <br />© 2015 Studio+ <br />