My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7350 Dairy Rd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
7350 Dairy Rd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 1:21:39 PM
Creation date
1/21/2025 3:43:12 PM
Metadata
Fields
Template:
Building Plans
Street #
7350
Location
Dairy Rd
Contractor
Ryan Companies
Building Plans - Permit #
17782
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOOR HARDWARE DESCRIPTION <br />01- <br />DOUBLEACTING DOOR: SEE HARDWARE SET AS PROVIDED IN ARCHITECTURAL <br />SPECIFICATION SECTION 087100. <br />02- <br />EXTERIOR DOOR W/PANIC HARDWARE. SEE HARDWARE SET AS PROVIDED IN <br />A HITE RAL ECIFI TION CTIO 8710 <br />03- <br />NEW PATIENT ROOM DOORS: PRIVACY FUNCTION - MORTISE LOCK WITH INTERIOR <br />THUMB TURN AND EMERGENCY KEY OVERRIDE ON THE EXTERIOR OF THE DOOR. <br />INTERIOR SIDE OF DOOR ALLOWS EGRESS AT ALL TIMES. DOOR IS FULLY GASKETED. <br />04- <br />NEW PATIENT TOILET ROOM DOORS: PRIVACY FUNCTION - MORTISE LOCK WITH <br />INTERIOR THUMB TURN AND EMERGENCY KEY OVERRIDE ON THE EXTERIOR OF THE <br />DOOR. DOORS SWING OUT FROM PATIENT TOILET ROOMS AND ALLOW EGRESS FROM <br />WITHIN THE TOILET ROOMS AT ALL TIMES. <br />05- <br />NEWSTORAGEROOMDOORS: STORAGE FUNCTION - MORTISE LOCK WITH KEYENTRY <br />FROM THE EXTERIOR/ CORRIDOR SIDE OF THE DOOR. DOOR IS OUTFITTED WITH A <br />CLOSER, IS FULLY GASKETED AND ALLOWS EGRESS FROM WITHIN THE STORAGE ROOM <br />AT ALL TIMES. <br />06- <br />NEW DOUBLE EGRESS PAIR: DOOR AND HARDWARE ARE RATED FOR 90 MINUTE <br />DOOR. DOOR IS EQUIPPED WITH PANIC BAR, MAGNETIC HOLD OPENS, AND CLOSER. <br />DURING NORMAL OPERATION, THE DOORS ARE HELD OPEN BY THE MAGNETIC HOLD <br />OPEN. THE MAGNETIC HOLD OPENS RELEASE THE DOORS UPON SOUNDING OF THE <br />FIRE ALARM SYSTEM. PANIC BARS ALLOW EGRESS AT ALL TIMES FROM THE <br />EGRESSING SIDE OF THE DOOR. THE DOOR IS FULLY GASKETED. <br />2 <br />J <br />2 <br />/ <br />J\ <br />DOOR <br />NUMBER <br />DOOR PANEL <br />SIZE <br />FIRE <br />RATING <br />DOOR <br />FRAME <br />WIDTH <br />HEIGHT <br />MATERIAL <br />FINISH <br />TYPE <br />MATERIAL <br />TYPE <br />C100 <br />7' - 6" <br />7' - 0" <br />90 MIN <br />SCWD <br />P1 <br />3 <br />EXIST. <br />EXIST. <br />N2 <br />4'- 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N2T <br />3'- 0" <br />T - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N3 <br />4' - 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N3T <br />3'- 0" <br />T - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N5 <br />4' - 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N5T <br />T - 0" <br />7' - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N7T <br />4'- 0" <br />7' - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N8T <br />4'- 0" <br />7' - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N15 <br />3' - 0" <br />7' - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N16 <br />4' - 0" <br />7' - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N16T <br />T - 0" <br />T - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N19 <br />4'- 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N19T <br />3'- 0" <br />7' - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N20 <br />3' - 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N21 <br />4' - 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST, <br />N21T <br />3' - 0" <br />T - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N24 <br />4'- 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N24T <br />3' - 0" <br />T - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N25 <br />4'- 0" <br />7' - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N25T <br />3'- 0" <br />T - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N26 <br />4'- 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N26T <br />3' - 0" <br />7' - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N28 <br />4' - 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N28T <br />3'- 0" <br />7' - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N31 <br />4'- 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N31T <br />3' - 0" <br />T - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N32 <br />4'- 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N32T <br />T - 0" <br />7' - 0" <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N33 <br />3'- 0" <br />T - 0" <br />SMOKE <br />SCWD <br />P1 <br />1 <br />EXIST. <br />EXIST. <br />N100 <br />4'- 0" <br />T - 0" <br />-- <br />ALUM. <br />ALUMN. <br />2 <br />ALUMN. <br />A <br />EXISTING WALL ASSEMBLY. <br />STUCCO OVER METAL LATH / 1" <br />RIGID INSULATION 15/8" <br />SHEATHING W/ WEATHER <br />Q <br />BARRIER 13 5/8" METAL STUDS <br />W <br />2 <br />U <br />U) <br />O <br />PATCH AND REPAIR <br />STUCCO AS NEEDED <br />I — <br />Of <br />w <br />LL <br />LLI <br />WEATHER BARRIER. PATCH AND <br />Of <br />REPAIR. PROVIDE NEW FLASHING <br />AND SEALANT. <br />REFER TO SCHED. <br />/ <br />/ <br />/ <br />0 <br />W <br />2 <br />U <br />W <br />O <br />I — <br />Of <br />W <br />LL <br />W <br />cIf <br />REFER TO SCHED. <br />DOOR SCHEDULE <br />DETAILS HARDWARE <br />HEAD JAMB PANIC HARDWARE HARDWARE GROUP <br />-- -- Yes 06 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 01 <br />-- -- 01 <br />-- -- 05 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 05 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 03 <br />-- -- 04 <br />-- -- 05 <br />6/A6.01 7/A6.01 Yes 02 <br />REFER TO SCHED. <br />CV <br />T <br />N <br />QLU <br />/ \ <br />U / \ <br />0 / \ U <br />0 U) <br />LL] <br />\ / O <br />i j \ LL:/ w <br />LL <br />of\\ Q /LL:/ LLI <br />2 1/2" REFER TO 2 1/2" <br />SCHED. TT <br />M <br />REMARKS <br />DOUBLE EGRESS PAIR W/ PANIC BAR AND MAGNETIC HOLD OPEN <br />DOUBLE ACTING DOOR W/ WIRE BRUSHING AT EDGES <br />DOUBLE ACTING DOOR W/ WIRE BRUSHING AT EDGES <br />ACCESS CONTROL - PANIC BAR <br />2" 4'-0" 2" <br />111111 7- <br />3 <br />i.01 <br />N <br />2" REFER TO SCHED. 2" <br />SCHEDULED STOREFRONT - <br />INSTALL PER FLORIDA PRODUCT 1 2 3 A B C <br />APPROVALFL8787.3 STOREFRONT DOUBLE ACTING EXISTING DOUBLE <br />FLORIDA PRODUCT APPROVAL: EGRESS <br />8786.3 <br />3 <br />STOREFRONT HEAD DETAIL <br />7 <br />DOOR & FRAME ELEVATIONS <br />1 <br />3" = 1'-0"" <br />3/8" = 1 "-0'" <br />NOTE: PROVIDE ANCHORS AT HEAD AT 2'-0" O.C. MIN WHEN <br />FRAME FOR PAIR OF DOORS IS GREATER THAN 5'-0". <br />EXISTING MTL. STUDS - <br />5/8" GYP BD <br />REPAIR/REPLACEAS <br />VARIES SEE <br />NEEDED. <br />I <br />_ <br />VARRIES SEE <br />SEALANT EACH SIDE <br />I <br />PARTITION TYPE <br />EXISTING PAINTED GYP BOARD - <br />I <br />PERIMETER NEOPRENE <br />PATCH AND REPAIR INTERIOR WALL <br />AND BASE AS NEEDED <br />I <br />I <br />PARTITION TYPE <br />SMOKE SEAL SYSTEM BY <br />I <br />_I I <br />NATIONAL GUARD <br />GYP. BD. - NUMBER <br />CONTINUOUS SEALANT <br />I \ <br />D <br />PRODUCT OR EQUAL <br />OF LAYERS AS <br />NUMBER OF LAYERS <br />SCHEDULED <br />EXISTING WALL ASSEMBLY. 4" <br />jBRICK FACE! 1" AIR GAP / 5/8" <br />AS SCHEDULED <br />METAL STUDS <br />I , I SHEATHING W! WEATHER BARRIER <br />-I I 35/8"METAL STUDS <br />3 5/8„ METAL STUDS <br />SEALANT (EACH SIDE) <br />I%I <br />SEALANT (EACH SIDE) <br />WEATHER BARRIER. PATCH AND <br />REPAIR. PROVIDE NEW FLASHING <br />H.M. DOOR FRAME <br />AND SEALANT. <br />CONTINUOUS SEALANT <br />H.M. DOOR FRAME <br />RABBIT BEYOND <br />SCHEDULED STOREFRONT- <br />INSTALL PER FLORIDA PRODUCT <br />LIGHTLY PACKED FIBERGLASS <br />SOLID CORE DOOR <br />APPROVAL FL8787.3 <br />OR MINERAL WOOL <br />INSULATION <br />DOOR - REFER TO SCHEDULE <br />DOOR - REFER TO SCHEDULE <br />DBL ACTING DOOR FRAME <br />NOTE: PROVIDE MANUFACTURER'S RECOMENDATION <br />2X FRT BLOCKING <br />HEAD REINFORCING FOR DOORS OVER T-0" WIDE. <br />DBL METAL STUD FRAMING <br />PROVIDE MIN DOUBLE CHANNEL. <br />STOREFRONT JAMB DETAIL 8 DOOR HEAD DETAIL 4 DBL ACTING DOOR JAMB DETAIL 3 HEAD DETAIL -DOUBLE EGRESS 2 <br />31" = 1 "-01 <br />" 31" = 1 "-01 <br />" 31" = 1 "-0"" 31" = 1 "-01 <br />" <br />REFER TO SCHED k <br />V.I.F. REFER TO SCHED. <br />1'-1" <br />- <br />NV <br />1. INTERIOR SIGNS SHALL COMPLY WITH CHAPTER 7 OF THE <br />7 �. TYR <br />2014 EDITION OF THE FLORIDA ACCESSIBILITY CODE <br />(MIN.) <br />EXISTING WALL ASSEMBLY. <br />STUCCO OVER METAL LATH/7" <br />I I � <br />�4 <br />2. SUBMIT SHOP DRAWINGS INDICATING SIZE, SHAPE <br />011 <br />6.� <br />RIGID INSULATION 1518" <br />SHEATHING W/WEATHER <br />'11001 <br />- <br />91, AND DETAILS OF CONSTRUCTION OF LETTER AND00 <br />\ / <br />BARRIER 13 5/8" METAL STUDS <br />SIGNS. <br />\ / 04 <br />AREA OF 3. THE CHARACTERS AND BACKGROUND OF SIGNS SHALL <br />- LL: <br />FLEXIBLE WIND ABATEMENT SCREEN <br />ANCHORED TO STRUCTURE- <br />�� <br />18" MIN <br />REFUGE <br />BE A NON -GLARE FINISH. CHARACTERS AND <br />SEE DOOR SCHED. X N - <br />~ > <br />NSTALLPER NOAN0.15-0316.09 <br />CENTER ON <br />SYMBLOLS SHALL CONTRAST WITH THEIR BACKGROUND. <br />/ \ <br />TACTILE <br />CHARACTERS \ <br />4. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT <br />/ \ <br />\\ <br />x TO THE LATCH SIDE OF THE DOOR. <br />/ TYR / \ <br />Z <br />— g 5. COPY FOR SIGNS SHALL BE APPROVED BY ARCHITECT. <br />i 16 01 <br />E0 CD 6. INSTALL SIGNS WITH 1/16" DOUBLE SIDED FOAM TAPE. <br />- <br />7. SIGNS CONTAINGING TACTILE CHARACTERS SHALL BE <br />EXISTING WINDOW SYSTEM <br />\ <br />LOCATED SO THAT A CLEAR FLOOR SPACE OF 18" X 18" <br />A <br />MIN., CENTERED ON THE TACTILE CHARACTERS, IS <br />IMPACT RESISTANT <br />PROVIDED BEYOND THE ARC OF ANY DOOR SWING. <br />STOREFRONT <br />NOA NO. 15-0528.24 <br />WINDOW SHUTTER DETAIL <br />9 <br />ADA SIGNAGE REQUIREMENTS <br />6 <br />WINDOW ELEVATIONS <br />5 <br />3"" = 1'-0"' <br />' <br />1/2" = 1 "-01 <br />" <br />3/8" = 1 "-01 <br />tudlo+�---' <br />California I Florida I Nevada <br />2211 E. 7TH Avenue, Tampa, Florida 33605 <br />P:239.357.4983 AA26002373 <br />Peninsula Engineering, INC. <br />MEP&FP <br />2016 Alden Road Orlando, FL 32803 <br />P: 407.246.1688 <br />F: 407.246.1664 <br />LBA INTERIORS <br />INTERIOR DESIGNER <br />5650 DTC PARKWAY, SUITE 100 <br />ENGLEWOOD, CO. 80111 <br />P:303.773.0436 <br />F:303.773.0053 <br />REVISIONS: <br />1 <br />1 07/29/2016 <br />JAHCA COMMENTS <br />2 <br />1 11/23/2016 <br />1 REVISION 1 <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 <br />R J CT TITLE: <br />P YRH I LLS HEALTH & <br />REHAB CENTER <br />SKILLED NURSING -10 BED <br />CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL. 33540 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />DOOR WINDOW SCHEDULE <br />A6mOl <br />© 2015 Studio+ <br />C:\Users\LevvN\Documents12016.04.20 - CENTRAL - ADVENTIST - ZEPHYRHILLS HEALTH AND REHAB CENTER LevvN.rvt <br />
The URL can be used to link to this page
Your browser does not support the video tag.