My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7350 Dairy Rd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
7350 Dairy Rd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 1:21:39 PM
Creation date
1/21/2025 3:43:12 PM
Metadata
Fields
Template:
Building Plans
Street #
7350
Location
Dairy Rd
Contractor
Ryan Companies
Building Plans - Permit #
17782
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D1 EXISTING 2 HOUR FIRE -SMOKE BARRIER.SEE ALLOWABLE BUILDING AREA INCREASE <br />CALCULATIONS & CODE ANALYSIS ON LS1.10 (BELOW) <br />D2 CONSTRUCTION BARRIER AND WALK -OFF MAT - SEE DETAILS. <br />D3 NEGATIVE AIR MACHINE W/ HEPA FILTER. VENT HIGH WITH BAFFLE. DISCHARGE IN <br />DIRECTION OF ARROW. TYPICAL FOR EACH ROOM. COORDINATE WITH MECHANICAL. <br />ALLOWABLE BUILDING AREA <br />INCREASE CALCULATIONS & CODE <br />ANALYSIS <br />Determination of building construction type and occupancy classification is a <br />FBC Type V-A -per Table 601 and Type V-III per NFPA 220. <br />- Maximum square footage of each building area to be 9,500 per FBC Table <br />503. An area increase of 300% is allowable for a fully sprinklered facility. 9500 <br />+(300%X 9500=28500SF)=38,000SF. Additional area increases are not <br />necessary. <br />Each building area is separated by 2 Hour Fire walls to maintain a maximum of <br />38,000 SF <br />2 Hour Fire /Smoke (minimum) walls are used where these divisions also <br />correspond to the required smoke compartment arrangement each to be a <br />maximum of 22,500 SF. <br />The 2 hour fire / smoke wall between the new skilled nursing unit and existing <br />units is a 2 hour fire/smoke wall used as a smoke compartment wall and a Fire <br />Section separation wall. It is not required to be a horizontal exit for travel <br />distance reasons. <br />EMERGENCY <br />POTABLE WATER <br />STORAGE SHED <br />DRIVE WAY / PARKING LOT <br />1 tiff-n 7/8" 56'-8" 183'-8" <br />GENERAL NOTES <br />REFER TO ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING. <br />EXITING TABULATIONS (SKILLED NURSING) <br />COMPART. COMPART. OCCUP. SQ FT / # OF INCHES/ INCHES/ PROV. <br />AREA TYPE OCCUP. OCCUP. OCCUP. REQ'D.STR. STR. <br />tudio+ <br />1 A-1 <br />10,300 SF SLEEP 120 86 .2 26.6 90 California I Florida I Nevada <br />11,140 SF IANCILLARYI 240 47 2211 E. 7TH Avenue, Tampa, Florida 33605 <br />1A-2 1 2,070 SF JANCILLARYI 240 1 9 1 .2 1 1.8 1 1 112 P: 239.357.4983 AA26002373 <br />1B-1 <br />4,780 SF <br />SLEEP <br />120 <br />40 <br />2 <br />12.2 <br />180 <br />Peninsula Engineering, INC <br />4,940 SF <br />ANCILLARY <br />240 <br />21 <br />MEP.&FP <br />2016 Alden Road Orlando, FL 32803 <br />SEP "I <br />P: 407.246.1688 <br />4,220 SF <br />SLEEP <br />120 <br />36 <br />1 C-1 <br />.2 <br />8.2 <br />90 <br />F: 407.246.1664 <br />1,120 SF <br />ANCILLARY <br />240 <br />5 <br />LBA INTERIORS <br />�I <br />; ° v <br />�. <br />�. <br />. <br />INTERIOR DESIGNER <br />4,850 SF <br />SLEEP <br />120 <br />41 <br />1 D-1 <br />.2 <br />13.2 <br />45 <br />5650 DTC PARKWAY, SUITE 100 <br />5,800 SF <br />ANCILLARY <br />240 <br />25 <br />ENGLEWOOD CO.80111 <br />ggg <br />1 E-1 <br />5,460 SF <br />SLEEP <br />120 <br />46 <br />.2 <br />9.2 <br />45 <br />P:303.773.0436 <br />(NEW <br />F:303.773.0053 <br />WOr]R��K+` <br />FIRE <br />54,670SF <br />356 <br />72.2 <br />562 <br />SECT 1 C <br />LIFE SAFETY LEGEND <br />EXIT SIGN <br />E� M,—DU\— HORN - STROBE - HORN/STROBE <br />ElPULL STATION <br />OSMOKE DETECTOR <br />EC <br />FIRE EXTINGUSHER CABINET <br />FVC FIRE VALVE CABINET <br />EXIT EGRESS CAPACITY: XX <br />F�] CAPACITY IN NUMBER OF PERSONS <br />ft—m m — mm DEAD END CORRIDOR <br />COMMON PATH OF TRAVEL <br />TRAVEL DISTANCE TO SMOKE <br />COMPARTMENT <br />TRAVEL DISTANCE TO EXIT <br />1 HR RATED <br />WALUPARTITION <br />2 HR RATED <br />WALUPARTITION <br />3 HR RATED <br />WALUPARTITION <br />4 HR RATED <br />WALUPARTITION <br />FIRE SMOKE ' <br />WALUPARTITION <br />AREA NOT IN CONTRACT <br />OVERALL LIFE SAFETY FLOOR PLAN 1 <br />1 " = 20'-0" <br />KEY PLAN (N.T.S.): <br />PP!% <br />AREI <br />PROJECT <br />PROJECT NORTH <br />TRUE NORTH <br />LA <br />71/ <br />REVISIONS: <br />1 1 07/29/16 JAHCA COMMENTS <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 <br />PR'ITLE: <br />ZEC TRHILLS HEALTH & <br />REHAB CENTER <br />SKILLED NURSING -10 BED <br />CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL. 33540 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />ARCHITECTURAL LIFE <br />SAFETY FLOOR PLAN <br />LS1 ■ <br />l 0 <br />© 2015 Studio+ <br />u-n u s e rsta a n rw o c t,rrm <br />0/1 n/0n1 0 i-r_0-rQ ORA <br />HEALTH AND REHAB CENTER_danr.rvt <br />
The URL can be used to link to this page
Your browser does not support the video tag.