My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7350 Dairy Rd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
7350 Dairy Rd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 1:21:39 PM
Creation date
1/21/2025 3:43:12 PM
Metadata
Fields
Template:
Building Plans
Street #
7350
Location
Dairy Rd
Contractor
Ryan Companies
Building Plans - Permit #
17782
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />KEY NOTES <br />D1 EXISTING 2 HOUR FIRE -SMOKE BARRIER.SEE ALLOWABLE BUILDING AREA INCREASE <br />CALCULATIONS & CODE ANALYSIS ON LS1.10 (BELOW) , <br />D2 CONSTRUCTION BARRIER AND WALK -OFF MAT - SEE DETAILS. <br />D3 NEGATIVE AIR MACHINE W/ HEPA FILTER. VENT HIGH WITH BAFFLE. DISCHARGE IN <br />DIRECTION OF ARROW. TYPICAL FOR EACH ROOM. COORDINATE WITH MECHANICAL. <br />ALLOWABLE BUILDING AREA <br />INCREASE CALCULATIONS & CODE <br />ANALYSIS <br />Determination of building construction type and occupancy classification is a <br />FBC Type V-A -per Table 601 and Type V-III per NFPA 220. <br />Maximum square footage of each building area to be 9,500 per FBC Table <br />503. An area increase of 300% is allowable for a fully sprinklered facility. 9500 <br />+(300%X 9500=28500SF)=38,000SF. Additional area increases are not <br />necessary. <br />Each building area is separated by 2 Hour Fire walls to maintain a maximum of <br />38,000 SF <br />2 Hour Fire /Smoke (minimum) walls are used where these divisions also <br />correspond to the required smoke compartment arrangement each to be a <br />maximum of 22,500 SF. <br />The 2 hour fire / smoke wall between the i'iew skilled nursing unit and existing <br />units is a 2 hour fire/smoke wall used as a smoke compartment wall and a Fire <br />Section separation wall. It is not required to be a horizontal exit for travel <br />distance reasons. <br />EMERGENCY <br />POTABLE WATER <br />STORAGE SHED <br />DRIVE WAY / PARKING LOT <br />GENERAL NOTES <br />REFER TO ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING. <br />EXITING TABULATIONS (SKILLED NURSING) E <br />COMPART. COMPART. OCCUP. SQ FT / # OF INCHES/ INCHES/ PROV.10, <br />:a <br />AREA TYPE OCCUP. OCCUP. OCCUP. REQ'D. <br />STR. STR. tud <br />1 A-1 .2 26.6 90 <br />10,300SF SLEEP 120 86 California I Florida Nevada <br />11,140 SF JANCILLARY1 240 1 47 1 1 12211 E. 7TH Avenue, Tampa, Florida 33605 <br />1A-2 1 2,070 SF JANCILLARYI 240 1 9 1 .2 1 1.8 1 112 P: 239.357.4983 AA26002373 <br />1B-1 <br />4,780 SF <br />SLEEP <br />120 <br />40 <br />.2 <br />12.2 <br />180 <br />Peninsula Engineering, INC. <br />4,940 SF <br />ANCILLARY <br />240 <br />21 <br />MEP&FP <br />�y <br />::. <br />2016 Alden Road Orlando, FL 32803 <br />..................................................................................................................................................................................................................................... <br />4,220 SF <br />........... <br />SLEEP <br />...... <br />120 <br />............. <br />36 <br />................ <br />P: 407.246.1688 <br />1 C-1 <br />.2 <br />8.2 <br />90 <br />F: 407.246.1664 <br />1,120 SF <br />ANCILLARY <br />240 <br />5 <br />R> <br />472 <br />LBA INTERIORS <br />4,850 SF <br />SLEEP <br />120 <br />41 <br />INTERIOR DESIGNER <br />1 D-1 <br />.2 <br />13.2 <br />45 <br />5650 DTC PARKWAY, SUITE 100 <br />5,800 SF <br />ANCILLARY <br />240 <br />25 <br />EN LEW 111 <br />G 00D CO 80 <br />IfR. 1101,11°..; <br />1 E-1 <br />5,460 SF <br />SLEEP <br />120 <br />46 <br />.2 <br />9.2 <br />45 <br />P:303.773.0436 <br />(NEW <br />F:303.773.0053 <br />FIRE 54,670SF 356 72.2 562 <br />SECT 1C <br />LIFE SAFETY LEGEND <br />X EXIT SIGN <br />LEA" ='_ 11c" HORN - STROBE - HORN/STROBE I <br />O <br />FVC <br />PULL STATION <br />SMOKE DETECTOR <br />FIRE EXTINGUSHER CABINET <br />FIRE VALVE CABINET <br />EXIT EGRESS CAPACITY: XX <br />CAPACITY IN NUMBER OF PERSONS <br />•������������• DEAD END CORRIDOR <br />—, 11 —, —, 0 1 COMMON PATH OF TRAVEL <br />TRAVEL DISTANCE TO SMOKE <br />COMPARTMENT <br />TRAVEL DISTANCE TO EXIT <br />1 HR RATED <br />WALL/PARTITION <br />,y............................... ...... 2 HR RATED <br />WALL/PARTITION <br />_......... ........... 3 HR RATED <br />WALL/PARTITION <br />d HR RATED <br />__.___._._.. - ......_.._.._ WALUPARTITION <br />___........._.............................................__.._.... FIRE SMOKE <br />WALL/PARTITION <br />AREA NOT IN CONTRACT <br />OVERALL LIFE SAFETY FLOOR PLAN 1 <br />lit = 20'-0" <br />KEY PLAN (N.T.S.): <br />PRO., <br />AREA <br />PROJECT <br />PROJECT NORTH <br />TRUE NORTH <br />LA <br />REVISIONS: <br />1 1 07/29/2016 JAHCA COMMENTS <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 <br />.1 r\4 4-p , <br />ao <br />WWRHILLS <br />ITLE: <br />HEALTH & <br />REHAB CENTER <br />SKILLED NURSING -10 BED <br />CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL. 33540 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />ARCHITECTURAL LIFE <br />SAFETY FLOOR PLAN <br />LS1 ■ <br />l 0 © 2015 Studio+ <br />C:\Users\LevvN\Documents\2016.04.20 - CENTRAL - ADVENTIST - ZEPHYRHILLS HEALTH AND REHAB CENTER LevvN.rvt <br />