Laserfiche WebLink
Al <br />KEY NOTES <br />D1 EXISTING 2 HOUR FIRE -SMOKE BARRIER.SEE ALLOWABLE BUILDING AREA INCREASE <br />CALCULATIONS & CODE ANALYSIS ON LS1.10 (BELOW) <br />D2 CONSTRUCTION BARRIER AND WALK -OFF MAT - SEE DETAILS. <br />D3 NEGATIVE AIR MACHINE W/ HEPA FILTER. VENT HIGH WITH BAFFLE. DISCHARGE IN <br />DIRECTION OF ARROW. TYPICAL FOR EACH ROOM. COORDINATE WITH MECHANICAL. <br />ALLOWABLE BUILDING AREA <br />INCREASE CALCULATIONS & CODE <br />ANALYSIS <br />Determination of building construction type and occupancy classification is a <br />FBC Type V-A -per Table 601 and Type V-III per NFPA 22C. <br />Maximum square footage of each building area to be 9,500 per FBC Table <br />503. An area increase of 300% is allowable for a fully sprinklered facility. 9500 <br />+(300%X 9500=28500SF)=38,000SF. Additional area increases are not <br />necessary. <br />Each building area is separated by 2 Hour Fire walls to maintain a maximum of <br />38,000 SF <br />2 Hour Fire /Smoke (minimum) walls are used where these divisions also <br />correspond to the required smoke compartment arrangement each to be a <br />maximum of 22,500 SF. <br />The 2 hour fire / smoke wall between the new skilled nursing unit and existing <br />units is a 2 hour fire/smoke wall used as a smoke compartment wall and a Fire <br />Section separation wall. It is not required to be a horizontal exit for travel <br />distance reasons. <br />GENERAL NOTES <br />REFER TO ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING. <br />LIFE SAFETY INFORMATION <br />CODE SECTION <br />NUMBER OF EXITS - PER FBC TABLE 1021. <br />EXIT SEPERATION - PER FBC SECTION 1015.2.1 <br />EXIT ACCESS TRAVEL DISTANCE - PER FBC TABLE 1016.2 <br />COMMON PATH OF TRAVEL - PER FBC SECTION 1014.3 <br />I DEAD END CORRIDORS - PER FSBC SECTION 1018.4 1 1 <br />CORRIDOR EXIT ACCESS WIDTH - PER FBC SECTION 1018.2 <br />DOORS - PER FBC SECTION 1008.1.1 <br />I SMOKE COMPARTMENT - PER N FPA SECTION 20.3.7.3 1 1 <br />LIFE SAFETY LEGEND <br />m EXIT SIGN <br />E]KI�\ \— HORN - STROBE - HORN/STROBE <br />PULL STATION <br />SMOKE DETECTOR <br />FEC <br />FIRE EXTINGUISHER CABINET <br />_-1 <br />FVC FIRE VALVE CABINET <br />EXIT EGRESS CAPACITY: XX <br />CAPACITY IN NUMBER OF PERSONS <br />•— m—m—m• DEAD END CORRIDOR <br />COMMON PATH OF TRAVEL <br />TRAVEL DISTANCE TO SMOKE <br />COMPARTMENT <br />TRAVEL DISTANCE TO EXIT <br />1 HR RATED <br />WALL/PARTITION <br />................................................... 2 HR RATED <br />WALL/PARTITION <br />3 HR RATED <br />WALL/PARTITION <br />4 HR RATED <br />____ _.__.__._..__. __.. _.__._.._......... WALL/PARTITION <br />FIRE SMOKE <br />WALL/PARTITION <br />AREA NOT IN CONTRACT <br />ENLARGED LIFE SAFETY FLOOR PLAN 1 1 <br />1 /8" = 1'-0" <br />KEY PLAN (N.T.S.): <br />PROJ <br />AREA <br />PROJECT <br />PROJECT NORTH TRUE NORTH <br />Peninsula Engineering, INC. <br />MEP&FP <br />2016 Alden Road Orlando, FL 32803 <br />P: 407.246.1688 <br />F: 407.246.1664 <br />LBA INTERIORS <br />INTERIOR DESIGNER <br />5650 DTC PARKWAY, SUITE 100 <br />ENGLEWOOD, CO. 80111 <br />P:303.773.0436 <br />F:303.773.0053 <br />REVISIONS: <br />1 1 07/29/2016 JAHCA COMMENTS <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 <br />AR97653 <br />a� <br />TITLE: <br />2;EHf(RHILLS HEALTH & <br />REHAB CENTER <br />SKILLED NURSING -10 BED <br />CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL. 33540 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />ENLARGED LIFE SAFETY <br />FLOOR PLAN <br />LS1 ■ <br />20 <br />1�17 @ 2015 Studio+ <br />C:\Users\LevvN\Documents\2016.04.20 - CENTRAL - ADVENTIST - ZEPHYRHILLS HEALTH AND REHAB CENTER LevvN.rvt <br />