My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7449 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7449 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 9:22:56 PM
Creation date
1/21/2025 3:43:47 PM
Metadata
Fields
Template:
Building Plans
Street #
7449
Location
Gall Blvd
Contractor
Horizon General Construction Inc
Building Plans - Permit #
3300
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SONIC SONIC <br />A28 <br />---iSLLJ 01) <br />16 <br />IWO <br />11 <br />A32' <br />(SW "2) <br />TYP. <br />n <br />n <br />ON <br />00 m <br />n <br />MOUNT TRANSFORMERS SIDE BY SIDE. EXTEND 25'-0' OF BOTH <br />COLORS OF TUBING FROM EACH TRANSFORMER ON CANOPY, OR <br />50'-0' OF RED TUBING FROM EACH TRANSFORMER ON PARAPET, <br />IN OPPOSITE DIRECTIONS AS INDICATED. SEE ARCHITECTURAL <br />DETAILS FOR EXACT NEON TUBE LOCATION AND MOUNTING. <br />(2) N 10 CU THWN , (U M 10 CU GROUND 4 (U <br />3/4' CONDUIT. SEE 01/E1 FOR CONTINUATION <br />ONE RUN OF 15MM NEON, RED. SEE <br />SPECIFICATION ON SHEET SP-2 (TYPICAL) <br />TWO RUNS OF 15MM NEON, RED AND YELLOW. <br />SEE SPECIFICATION ON SHEET SP-2 (TYPICAL) <br />i <br />TOP OF-----' <br />CANOPY <br />1 \ <br />) <br />A32' =7`l <br />(SW 02) TOP OF PARAPET I <br />WALL <br />n <br />B51 B53 <br />` (SW MI)f <br />WP <br />21 <br />I <br />I <br />I <br />I <br />I <br />553 <br />(SW 01) <br />I <br />I / <br />I� <br />WP <br />23 21 <br />1 <br />A33,35,3'1 <br />lSW "1) <br />01 CANOPY /MENU WIRING PLAN <br />1/8' = 11-ON <br />NO <br />1 <br />ri <br />23 <br />A11,19 A21,23,252-1,29 <br />(SW 02) (SW 11) <br />JA31 <br />(sw 01) <br />i <br />_ J <br />23 <br />I I 0� (ol <br />NEON TRANSFORMER. BEE SPECIFICATION ON SHEET 5P-2. <br />12OV ,IP/20 AMP NEMA 3R NON FUSED DISCONNECT MOUNTED ON BACK OF — <br />PARAPET AT BUILDING AND BEHIND NEON CHANNEL AT CANOPY. PROVIDE <br />SEPARATE DISCONNECT FOR EACH TRANSFORMER SEE ARCHITECTURAL <br />DETAILS FOR EXACT PARAPET WALL OR CANOPY CONFIGURATION. (TYPICAL) <br />OZ NEON TRANSFORMER DETAIL <br />Z � <br />A32 % <br />(SW 02) <br />NO SCALE <br />A30 <br />(SW 01) <br />15 <br />A30 <br />(SW #9 <br />15 <br />NOTES 81' SYMBOL <br />O NEON TRANSFORMERS FURNISHED AND INSTALLED BY NEON CONTRACTOR E.G. TO FURNISH 4 INSTALL <br />CONDUIT AND WIRE ONLY. E.G. TO VERIFY WITH OWNER'S REPRESENTATIVE EXTENT OF NEON 4 EXACT <br />NUMBER 4 LOCATION OF TRANSFORMERS. - REF. DETAIL E-1-02 <br />O2 NOT USED <br />03 CEILING FAN BY E.G. 'DAYTON' 56 04C111. G.G. TO INSURE STRONG MOUNTING, G.C. TO PROVIDE <br />STRUCTURAL SUPPORT USING UNISTRUT OR OTHER ACCEPTED STANDARD MEMBER FOR <br />CONSTRUCTION, IF NECESSARY. DO NOT SUPPOURT FANS FROM DECK ONLY. BEAL ANY HOLES MADE <br />IN CANOPY DECK <br />O PROVIDE JUNCTION BOXES W/WP COVER ABOVE CANOPY, MTD. TO ROOF FOR CONNECTION / <br />EXTENTION OF CONDUIT 4 WIRING FROM CANOPY LIGHTS, MENU LIGHTS, 4 NEON LIGHTING <br />TRANSFORMERS. EXTEND CONDUIT FROM JUNCTION BOX TO ADJ. SUPPORT COLUMN 4 DOWN COLUMN <br />TO BELOW GRADE. EXTEND CONDUIT 4 CONDUCTORS TO PANEL 'A'. <br />O 2' PVC CONDUIT FOR MENU SPEAKER WIRE ONLY. WIRE BY OTHERS. <br />O6 3/4' CONDUIT FOR MUSIC SPEAKER WIRE ONLY. EXTEND CONDUIT UP STRUCTURAL COLUMN TO ABOVE <br />CANOPY DECK PROVIDE PULL STRING. WIRE BY OTHERS. <br />O MOUNT TYPE 'G' FIXTURES TO CANOPY DECK, ALIGN WITH (t OF CANOPY COLUMNS. <br />OS 3/4' CONDUIT LOOPED OVERHEAD FOR CANOPY LIGHTING. <br />O9 3/4' CONDUIT LOOPED OVERHEAD FOR MENU SPEAKER WIRING. <br />10 3/4' CONDUIT LOOPED OVERHEAD FOR MENU LIGHTING. <br />11 NIGHT LIGHT THRJ PHOTO CELL (PART. CKT. A20) <br />12 CONDUIT U.G. TO JUNCTION BOX FOR SPEAKER WIRE. - REF E-4.02 <br />13 PHOTO CELL ON ROOF FOR LIGHTING CONTROL. <br />14 CONDUIT Ua. UP TO 6' x 6' JUNCTION BOX WITH A I' CONDUIT STUBBED ABOVE CEILING FOR MUSIC <br />WIRING. <br />15)WATER PROOF J-BOX AT ENTRY / EXIT SIGN. SEE SITE PLAN. <br />lro PROVIDE 120V, 1P/20 AMP NEMA 3R NON FUSED DISCONNECT AT MAIN SIGN. CONTRACTOR MUST <br />VERIFY LOCATION ON SITE PLAN. EXTEND 1' CONDUIT W/ (2) *10 CU THWN AND (1) M2 CU GROUND SIGN <br />LOCATION TO PANEL 'A'. <br />1� TO PATIO CEILING FAN SWITCH. REF E-2. <br />18 I' PVC CONDUIT TO PATIO MENUS <br />19 ROUTE CONDUITS 4 CONDUCTORS FROM DISCONNECTS AT NEON TRANSFORMERS TO THIS NEMA 3R <br />JUNCTION BOX MOUNTED ON BACKSIDE OF PARAPET WALL. DROP DOWN (2) CIRCUITS W92) 010 CU <br />THWN, (I) 010 CU GROUND EACH IN (1)1' CONDUIT. <br />2® POLE MOUNTED SITE LIGHTING. CONTRACTOR MUST VERIFY LOCATION ON SITE PLAN. EXTEND 1' <br />CONDUIT W92) 08 CU THWN 4 (1) 010 CU GROUND FROM EACH POLE LOCATION TO PANEL 'A'. MAX. OF 3 <br />HEADS PER CIRCUIT. <br />21 U.G. DETECTOR LOOP, SPEAKER PEDESTAL, 4 MENU BOARD. REF. SD-2.01, SD-221, 4 SITE PLAN. <br />22 3/4' PVC CONDUIT TO DRIVE-THRU MENU. <br />23 CONDUIT FILL SHALL BE IN ACCORDANCE WITH NEC ARTICAL 300.11. WHERE MORE THAN 3 CURRENT <br />CARRING CONDUCTORS ARE INSTALLED IN A RACEWAY, CONDUCTOR CAPACITY MUST BE DERATED <br />PER NEC TABLE 310-15(5X2Xa). ANY 3 CURRENT CAKING CONDUCTORS THAT ARE CIRCUITED <br />ACROSS PHASES 'A', 'B' AND 'C' , IAY BE SERVED BY A COMMON NEUTRAL . <br />0 <br />w <br />En <br />En <br />cr <br />Wo <br />Lu <br />_W Z <br />H <br />c3N , <br />Z W) <br />Wom <br />co <br />ZQX <br />ZJ=ui <br />a:) 2 s: <br />y= W <br />ZZoQ <br />000) <br />CvC-)� <br />® oL,Zo <br />aoo <br />} o <br />� <br />® w U <br />®s O>% <br />oow <br />V cn <br />0 <br />� wN< <br />�m0Z <br />c� <br />® ZOO <br />® wow <br />co <wF- <br />;~o <br />3m0 <br />a gZo <br />L'i <br />@s ~�WIZ <br />0 <br />o <br />V <br />A <br />z <br />d <br />A- >o <br />o QC 1L <br />~ u- <br />Ln <br />c� <br />0 4w <br />0 CLUB <br />0 <br />L d (L <br />a0 N LU <br />emu_ 0 <br />Z <br />ul U <br />SHEET <br />El <br />DWG: <br />005080—El <br />
The URL can be used to link to this page
Your browser does not support the video tag.