Lin II II 1 <br />2@ yfl( 5@09 <br />TO WINDOW NEON <br />RECEPTACLES. <br />REF. E3 <br />TO PATIO CEILING <br />FANS. REF. E-I <br />REFERENCE NORTH <br />FOR ROOM FINISH <br />SCHEDULE ONLY <br />FOR CANOPY 4 REMAINDER OF EXTERIOR LIGHTING, REF_ 6HEET "=-1"_ <br />1 LIGHTING PLAN <br />max, j " <br />. <br />F. <br />ELECTRICAL S`rM50LS <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />FLUORESCENT LIGHTING FIXTURE, RECESSED MOUNTED. <br />$K $p <br />KEY OPERATED SWITCH, PILOT LIGHT SWITCH, MTD. 48' UP. <br />FLUORESCENT LIGHTING FIXTURE, SURFACE OR SUSPENDED. <br />2-$ <br />NUMBER DENOTES SINGLE POLE SWITCHES GANG MOUNTED. <br />O ❑ O+ <br />INCANDESCENT AND HID LIGHTING FIXTURES, CLG. t WALL MTD. <br />v <br />TELEPHONE OUTLET MTD. 24' UP. <br />D <br />FLOOD LIGHTING UNIT. <br />DATA OUTLET FOR PAS. SYSTEM. EMPTY 44 BOX W/ 1-1/2' PVC <br />CONDUIT TO ABOVE CEILIWsWIRING BY OTHERS. SUPPLY S.S. <br />COVER PLATE W/2' DIA GROMIT HOLE <br />® <br />EXIT SIGN, DIRECTIONAL ARROWS INDICATED. <br />STRIP FLUORESCENT LIGHTING UNIT, SURFACE OR SUSPENDED. <br />JUNCTION OR PULL BOX. <br />Ts PE <br />TIME SWITCH, PHOTO —ELECTRIC SWITCH. <br />SINGLE PLEX RECEPTACLE, MOUNTED 24' UP UNLESS NOTED OTHERWISE. <br />$y <br />MANUAL MOTOR STARTER —DISCONNECT SWITCH. <br />DUPLEX RECEPTACLE, MOUNTED 24' UP UNLESS NOTED OTHERWISE. <br />MOTOR DISCONNECT OR FUSED SAFETY SWITCH. <br />QUAD RECEPTACLE. TWO DUPLEX RECEPTACLES GANG MOUNTED. <br />® <br />MOTOR <br />DUPLEX RECEPTACLE ON EMERGENCY POWER SYSTEM. <br />= <br />ELECTRICAL PANELBOARDS, SURFACE AND FLUSH MOUNTED. <br />GF14& <br />GROUND FAULT INTERRUPTNG RECEPTACLE. <br />120 OR 211V CIRCUIT HOME RUN TO PANEL. LINE, NEUT., GND. <br />wpO <br />WEATHER PROOF GROUND FAULT INTERRUPTING RECEPTACLE. <br />�j,o <br />480, 240, 208V CIRCUIT HOME RUN TO PANEL, WIRE SIZE NOTED. <br />POLARIZED THREE OR FOUR WIRE RECEPTACLE, RATING NOTED. <br />SINGLE RECEPTACLE IN HANDY BOX MOUNTED ON CONDUIT STUB. <br />CONDUIT CONCEALED IN WALLS OR ABOVE CEILING. <br />CONDUIT CONCEALED IN OR UNDER FLOOR <br />k� <br />DUPLEX RECEPTACLE IN HANDY BOX MOUNTED ON CONDUIT STUB. <br />wP <br />DENOTES 'WEATHER PROOF'. <br />0. <br />POLARIZED THREE OR FOUR WIRE RECEPTACLE, RATING NOTED. <br />EM <br />DENOTES LIGHTING FIXTURE ON EMERGENCY POWER CIRCUIT. <br />CEILING MOUNTED DUPLEX RECEPTACLE <br />*1. <br />PLAN NOTE. REFER TO NOTATION ON PLANS. <br />CEILING MOUNTED QUAD RECEPTACLE. TWO DUPLEX GANG MOUNTED <br />If I <br />FIRE ALARM MANUAL PULL STATION. <br />$ <br />SINGLE POLE SWITCH MOUNTED 48' UP UNLESS NOTED OTHERWISE. <br />® <br />SMOKE DETECTOR <br />$2 $, $q <br />TWO POLE, THREE WAY, FOUR WAY SWITCHES MTD. 48' UP. <br />ALL SYMBOLS MAY NOT APPEAR ON THE DRAWINGS. <br />545 <br />541 <br />NOTES 5Y SYMBOL <br />to JUNCTION BOX FOR COOLER AND FREEZER LIGHT CONNECTION. CONTRACTOR MUST FIELD VERIFY CONNECTION <br />REQUIREMENTS. TYPE 'C' FIXTURE IS PROVIDED WITH COOLER/FREEZER AND WIRED BY ELECTRICAL CONTRACTOR SEE <br />ALSO DRAWING SHEET E3 FOR ADDITIONAL INFORMATION. <br />20 CEILING MOUNTED EXHAUST FAN. CIRCUIT AND SWITCH WITH LOCAL LIGHT FIXTURE. SEE EXHAUST FAN SCHEDULE ON <br />DRAWING SHEET MI. FAN TO BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR FINAL CONNECTION BY <br />ELECTRICAL CONTRACTOR <br />O LIGHT FIXTURE TYPE 'AEM' AND EXIT LIGHT TYPE 'E' TO BE CIRCUITED ON UNSWITCHED LEG OF LOCAL LIGHT CIRCUIT. <br />'AEM' FIXTURE TO BE CONTINIOUS OPERATION AS NIGHT LIGHT. CIRCUIT EMERGENCY BATTERY PACK IN BALLAST <br />HOUSING ON THE SAME UNSWITCHED CIRCUIT. PROVIDE LOCK ON BREAKER <br />O MOUNT PHOTOCELL CONTROL ON ROOF ON BACK SIDE OF PARAPET WALL FACING NORTH. SEE OUSIDE LIGHTING AND <br />SIGNAGE CONTROL DIAGRAM ON DRAWING SHEET E5. <br />O PROVIDE (2) 120V )0 AMP WALL SWITCHES DESIGNATED '1' AND '2' FOR CONTACTOR CONTROL OF EXTERIOR LIGHTING <br />AND SIGNAGE CIRCUITS. SEE DRAWING SHEET E1 AND ELECTRICAL SERVICE RISER AND EXTERIOR LIGHTING CONTROL <br />DIAGRAM ON DRAWING SHEET E5. PERMANENTLY LABLE EACH SWITCH WITH ITS RESPECTIVE NUMBER DESIGNATION. <br />O MOUNT TYPE 'L' FIXTURE ON PARAPET WALL AT 12'-0' ABOVE FINISHED GRADE . <br />LIGHTING FIXTURE SCHEDULE <br />TYPE <br />DESCRIPTION <br />MOUNTING <br />LAMPS <br />'A' <br />2X4 TROFFER WITH ACRYLIC LENS <br />RECESSED <br />2-F32T8 <br />METALUX "264R8232A120 W/B2321120RHH BALLAST OR EQ. <br />(ALTERNATE: LIGHTOLIER'XT2GVA24012080 W/82321120RHH <br />BALLAST OR EQ.) <br />'B' <br />1 X 4 WRAPAROUND <br />SURFACE <br />2-F32T8 <br />METALUX US-232A-12OV.-E581 <br />(ALTERNATE: LITHONIA "S5-232A-120-GE5) <br />"51" <br />1 X 4 WRAPAROUND <br />SURFACE <br />2-F32T8 <br />LITHONIA "VSE-2-32-120-ES <br />'G' <br />VAPOR PROOF LIGHT BY OWNER <br />SURFACE <br />1-100W <br />PROVIDED W/ WALK-IN BOX <br />'D' <br />DELETED <br />'E' <br />SINGLE FACE EXIT SIGN WITH BATTERY <br />UNIVERSAL <br />LED W/ UNIT <br />LITHONIA *LES-WIR-ELN <br />(ALTERNATE: SURE-LITES "CAX-11-10-00-RW) <br />'F" <br />DELETED <br />2 LAMP STRIP FIXTURE (2-4 FT. TANDEM FIXTURES) <br />SURFACE <br />2-F32T8 <br />METALUX "8TS823212OE5-81 <br />EACH <br />(ALTERNATE: LIGHTOLIER *SW8T232HPF120H4GLR) <br />REF L.F.S. <br />FIXTURES COME STANDARD W/50 DEGREE BALLASTS. <br />NOTE 04 <br />0 DEGREE BALLAST AND LAMPS TO BE PROVIDED BY <br />E.G. AS REQ'D TO MEET LOCAL WEATHER CONDITIONS - <br />REF L.F.S. NOTE 04. <br />'H' <br />WIDE SPREAD FLOOD LIGHT <br />SURFACE <br />1-115W M.H. <br />LUMARK "MHWR-65T-1"15-120V <br />MOGUL <br />(ALTERNATE: HI-TEK "TFL-1-15M-TA2-120) <br />all <br />PORCELAIN KEYLESS LAMPHOLDER <br />SURFACE <br />1-FL815/ 1. <br />G.E. S-140-1 <br />Bill <br />POLE MOUNTED FLOOD LIGHT t POLE <br />POLE <br />1-400W. M.N. <br />LUMARK " MHWR-658-400-120V / 6S84A25SFM2XG <br />MOGUL <br />(ALT:HI-TEKOTFL-40OM-RA2-120-I5/585254GT20DD5) <br />(IF USED, SEE SITE PLAN) <br />'K' <br />DELETED <br />'L' <br />WALL MOUNTED FLOOD LIGHT <br />WALL <br />1-1-15W M.H. <br />LUMARK 0 MHWL-1-15-120V <br />MOGUL <br />(ALTERNATE: HI-TEK rUJH-Ii5M-120) <br />'M' <br />NOT USED <br />L.F.S. NOTES: <br />I. 'EM' DENOTES FIXTURE FURNISHED WITH FACTORY INSTALLED EMEF;raENCY LIGHTING <br />BATTERY PACK. <br />2. REFER TO ELECTRICAL SPECIFICATIONS FOR FURTHER INFORMATION REGARDING <br />LIGHTING FIXTURES AND LAMPS. <br />3. LIGHTING FIXTURES SHALL BE AS SPECIFIED ABOVE OR AN APPROVED EQUAL. <br />SUBSTITUTIONS MUST BE SUBMITTED FOR REVIEW BY OWNER. <br />4. E.G. TO PROVIDE EITHER A "B432PUNVHP-A UNIVERSAL OR OICN-4P32-SC-120V ADVANCE <br />'0' DEGREE BALLAST. USE 32 WATT 4 FT. T8 LAMPS IN THE '0' DEGREE RATED FIXTURES. <br />DO NOT USE 30 WATT 4 FT. T8 LAMPS WITH MODEL NUMBERS ENDING IN 'WM' (BY G.E), 'SS' <br />(BY OSRAM SYLVANIA), OR 'ALTA' (BY PHILIPS). USING 30 WATT LAMPS TURNS THE '0' <br />DEGREE RATED FIXTURE INTO A 50 DEGREE RATED FIXTURE. <br />ul <br />z <br />O <br />us <br />9 <br />Lu <br />Z <br />In <br />1A <br />1A <br />0 <br />w <br />V) <br />V) <br />OC — <br />WT_ <br />Lu ZW <br />C.D' <br />N <br />Z N <br />Wm^ <br />o`') <br />Z�3� <br />WJXZ <br />G.D=> <br />� W <br />ZZoQ <br />O O 01oc <br />1 u ms <br />-It <br />A 0 <br />® p YcnQ <br />r A <br />N <br />� <br />m_ <br />U <br />V Z 4 ., <br />® 04 <br />W.g� <br />rla M <br />m <br />29 <br />Z oEo <br />j0— 0: !R <br />aoo <br />> o <br />iz_ <br />® w U <br />� o�N <br />0 <br />am uj <br />m0Z <br />�ow i <br />® Zwc <br />® wow <br />�o <wiE <br />� ;~o <br />40 3Z <br />P �ZO <br />�7_25 <br />gw 0: <br />ww <br />Z <br />� o <br />V <br />0 <br />z <br />0��-� <br />0— <br />Lu <br />Lo <br />W <br />l�L <br />0 <br />Aft <br />-1 <br />-4 <br />..V^^ <br />v! <br />V <br />ff <br />o <br />< <br />� <br />(L <br />9 <br />:3 <br />00 <br />X <br />u <br />.4. <br />LL <br />44 <br />SHEET <br />E2 <br />NOTE: REFER TO DIVISION lfo ELECTRICAL SPECIFICATIONS <br />REF. SITE PLAN <br />FOR TRUE NORTH 1/4I = 1 I-0u (SHEET SP2) FOR ADDITIONAL INFOMATION. <br />n1ITITC31 <br />005080—E2 <br />