Laserfiche WebLink
5 4 3 2 1 <br />I� <br />4"X4" J-BOX - <br />FOR CAMERA. <br />CAMERA IN STORE <br />MOUNTED TO UNISTRUT. <br />CENTER CAMERA ABOVE <br />DOOR <br />NOTE: <br />GC TO PROVIDE 3/4" CONDUIT FROM CAMERA TO <br />OFFICE. INSTALLATION OF CAMERA SUPPORT BY G.C. <br />STEEL BAR JOIST <br />PROVIDE P3300 UNISTRUT OR EQUAL <br />LENGTH AS REQUIRED TO SPAN <br />JOISTS. SECURE TO BOTTOM CHORD <br />OF BAR JOIST. LOCATE 1' OFF EXTERIOR WALL. <br />SECURITY CAMERA MOUNTING <br />N.T.S. <br />C <br />Z <br />O <br />a <br />0 <br />U <br />tOl <br />JI <br />a <br />Z <br />11J <br />UI <br />v <br />4a <br />66 <br />C7 <br />C7 <br />J <br />t <br />a <br />t <br />NA <br />a, <br />N <br />00 <br />O <br />lD <br />r-I <br />t41 <br />c <br />W <br />E <br />U <br />O <br />i <br />U <br />3-5/8" x 20, <br />AT EACH J <br />3-5/8" x 20 or,. <br />STUDS AT 24" O.C. <br />METAL RUNNER CHANNEL <br />COOLER AND <br />FREEZER PANELS BY <br />7-ELEVEN <br />SECTION - COOLER WALL <br />3/4" = 1'-011 <br />SECTION @ BULKHEAD <br />UNISTRUT <br />BOTTOM CHORD <br />OF BAR JOIST INSET <br />NOTE: GC TO PROVIDE ELECTRICAL & 3/4" CONDUIT <br />FROM CAMERA/MONITOR TO OFFICE. INSTALLATION OF <br />MONITOR SUPPORT BY G.C. <br />STEEL BAR JOIST <br />PROVIDE P3300 UNISTRUT OR EQUAL <br />LENGTH AS REQUIRED TO SPAN <br />JOISTS. SECURE TO BOTTOM CHORD <br />OF BAR JOIST <br />J-BOX FOR SECURITY <br />CAMERA & MONITOR <br />DATA CABLES. <br />SECURITY MONITOR <br />IN STORE SUSPENDED / <br />FROM UNISTRUT <br />LOCATION TO BE <br />DETERMINED BY <br />CONSTRUCTION <br />MANAGER. <br />F7 <br />SECURITY MONITOR MOUNTING <br />1" =1'-0" <br />ROOF STRUCTURE ABOVE <br />\STEN RUNNER TO BOTTOM <br />OF STRUCTURE W/2 #6 TEK <br />SCREWS @ 24" O.C. <br />PAINTED GYP., REFERENCE <br />ROOM FINISH SCHEDULE <br />AND INTERIOR ELEVATION <br />_ BULLN_OSE TILE EDGE <br />REF INTERIOR ELEVATIONS <br />- CLOCK & TRI STRIPE ACCENT BAND; <br />REF EF SHEETS. SEE PLAN & INTERIOR <br />ELEVATIONS FOR LOCATION <br />WALL COVERING AS <br />SCHEDULED <br />WALL PACK <br />REF ELECTRICAL <br />ROOF STRUCTURE ABOVE (TYP) <br />FASTEN RUNNER TO BOTTOM <br />OF STRUCTURE W/2 #6 TEK <br />SCREWS @ 24" O.C. <br />STEEL BAR JOIST <br />3-5/8" x 20 GA. STUDS BACK -LIT FASCIA SIGNBY SIGN CONTRACTOR <br />AT 24" O.C. <br />3-5/8" x 20 GA. STUD <br />BRACING AT 24" O.C. <br />1/2" PAINTED GYP. BRD.; <br />REF ROOM FINISH <br />SCHEDULE AND <br />INTERIOR ELEVATIONS o <br />FOR FINISHES <br />A_.F.F. N <br />9'-4" <br />LAY IN CEILING <br />3/4 <br />I I <br />METAL STUD WALL <br />16 GA, CONT. RUNNER TRACK <br />ATTACHED W/ (2) #10 TEK <br />SCREWS AT 24" O.C. <br />1 1 6" 18 GA. C STUD CEILING JOISTS <br />AT 16" O.C. <br />PAINTED 5/8" GYP BD CEILING <br />(MOISTURE RESISTANT AT WET ROOMS) <br />WALL COVERING AS SCHEDULED <br />CEILING DETAIL <br />17� 311=11-011 <br />10' - 1 " <br />UNISTRUT <br />BOTTOM CHORD <br />OF BAR JOIST <br />INSET <br />MOUNTING BRACKET BY <br />OTHERS <br />6" COMPASSO <br />SUSPENSION <br />TRIM <br />SUSPENDED <br />GRID COMPASSO <br />SYSTEM ELITE CLIP <br />0 o O p 8 6 <br />LAY IN CEILING <br />5 CEILING TRIM DETAIL <br />A2.1..:. 311 = 11-011 <br />REFLECTED CEILING PLAN SYMBOLS <br />FOUR WAY AIR DIFFUSER ^N <br />/ SECURITY CAMERA <br />GYP BOARD CEILING <br />TRANSFER GRILL <br />RETURN AIR DIFFUSER PAINTED EXPOSED <br />STRUCTURE WALK IN COOLER <br />EVAPORATOR <br />CEILING <br />EXHAUST LED LIGHT <br />EXIT SIGN FIXTURE <br />O REF. ELECTRICAL <br />SECURITY MONITOR <br />SUSPENDED CEILING <br />GRID ® 8' LED LIGHT <br />FIXTURE <br />REF. ELECTRICAL <br />SECURITY CAMERA 2x2 LED EMERGENCY <br />LIGHT FIXTURE LIGHT FIXTURE <br />REF. ELECTRICAL REF. ELECTRICAL <br />EMERGENCY LED 2x2 LED <br />EXTERIOR WALL PACK ® LIGHT FIXTURE ® EMERGENCY <br />REF. ELECTRICAL REF. ELECTRICAL LIGHT FIXTURE <br />REF. ELECTRICAL <br />CEILING SCHEDULE <br />TYPE <br />DESCRIPTION <br />C1 <br />OPEN TO STRUCTURE <br />C2 <br />GYP BD CEILING <br />C-3 <br />A 1 LAY IN ACOUSTICAL CEILING TILE <br />GENERAL NOTES <br />1. ALL WALL PAINT ABOVE 9'4" IN THE MERCHANDISE / <br />SALES AREA SHALL BE P-4 , UNLESS NOTED OTHERWISE ON <br />RCP (REF SHEET A3.0 FOR MATERIAL SCHEDULE). <br />9'-11 1 /8" <br />WOMEN ELECTRICAL <br />SYRUP LINES TO SLURPEE <br />DISPENSERS. INSTALL IN PVC 106 108 <br />CONDUIT TO WALL POCKET <br />BELOW AND SEAL AS REQ'D. <br />__ _ _,_ <br />�x — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — —� <br />ICE FREEZER P.. C-3 <br />110 109 9' - 4' F.F. <br />C2 <br />8 0 FF <br />2 1 / C1 <br />12'-6'r 15'_Orr / _ P-4 <br />3 SIM / 3 <br />A2.1 I - <br />5 C-3 // �/ r n ° n I MEN74' <br />9 4 A.F.F. <br />A2.1 9'-4"A.F.F. ��-0 /'10-0' <br />VJ <br />105 <br />INSULATED /' / N �� ' <br />COOLER �/ / / 2 <br />CEILING /_ 1 _ 1,// / 1_ _ _ <br />// ✓� / / / // / 5A2.1/C1 <br />COOLER %/ j/// js�cYLIGHT CDC TOTE <br />VAULT / 107 <br />r c/cK// - - - --- // / MERCHANDISE - - -- C2 ; <br />101 :7 SALES 8'- 0"A.F.F..'- <br />3 A2.1102 <br />A2.1 C-3 <br />PAINT, / <br />S1�UCTURE <br />c1"X <br />- <br />_� P-4 / a <br />Ali //// / /// / / � / • <br />7 <br />A2.1BO <br />L:1 <br />N BACK �........._ c-3 <br />ROOM 10' - 6"A.F.F.I <br />MONITOR/ <br />KYLIGHT <br />8 -ffix <br />6 C2 <br />- .. • : 8'- 0"A.F.F. <br />CAMERRATYP. / w <br />BAR JOIST. / <br />TYP / EXIT SIGN <br />� / // -• - .. ; <br />SECURITY CAMERA TYP. - <br />- <br />a <br />OFFICE <br />w <br />WALL PACK ° ° 103 <br />LL <br />7' - 8 1 /4" <br />ELECTRICAL Ci <br />FOR USE WITH (TYP) w <br />FUELING SITES ONLY _ _ <br />COORDINATE <br />LOCATION <br />AND QTY. W/ <br />CONSTRUCTION <br />PROJECT MANAGER <br />1.0 <br />Z REFLECTED CEILING PLAN <br />1/4if =1'-0" <br />L <br />25'-4" <br />REFERENCE ELECTRICAL FOR LIGHTING PLAN <br />REFERENCE MECHANICAL FOR HVAC LAYOUT <br />30' - 9" <br />2.0 <br />B.0 <br />6" DIA. PVC CONDUIT <br />ABOVE CEILINGS FOF <br />SYRUP LINES - ROUTE (2 <br />BUNDLES OF 4 SYRUF <br />LINES PER 6" PVC <br />-� CONDUITAS REQUIRED <br />SEAL TO WALL FINISH Al <br />PENETRATIONS AN[ <br />APPLY SPRAY FOAM Ot <br />INTERIOR OF CONDUIT Al <br />ENDS TO SEAL AROUN[ <br />SYRUP LINES (TYF <br />THROUGH WALL <br />SYRUP LINE INSTALLATION <br />NOTE: WHERE REQ'D B) <br />CODE OR AS INDICATED O� <br />PLAN, CABLED BUNDLE <br />SYRUP LINES SHALL BE <br />INSTALLED IN PVC <br />CONDUIT (METAL CONDUIT <br />FOR FR LINES) W/ 45' <br />SWEEPS AT CORNER ANC <br />"TEE" CONNECTIONS <br />CONDUIT SHALL BE <br />ATTACHED TO WALL AN[ <br />UNDERSIDE OF ROOF <br />CONSTRUCTION W/ PIPE <br />STRAPS AS REQ'D <br />REFERENCE <br />MANUFACTUREF <br />SPECIFICATIONS FOF <br />MINIMUM ALLOWE[ <br />BENDING RADIUS OF LINE: <br />SYRUP LINE 974 SERIE1c <br />(974FR AT FIRE RATED WALLS <br />CABLED BUNDLE W/ 3/8" HOSE <br />IN GROUPS OF (4) (OR AC <br />REQUIRED BY EQUIF <br />VENDOR.) ATTACHED TC <br />BOTTOM OF DECK WITH 3/4 <br />WIDE, 16 GAUGE, GALVANIZE[ <br />PIPE STRAPS AT 4' O.C. MA) <br />A.1 <br />A.0 <br />AN& IMAM <br />106 N 37TH STREET, SUITE C <br />ROGERS, ARKANSAS 72756 <br />W W W. BATESARCH ITECTS.CO M <br />TEL: 479.633.8165 <br />Copyright 2016 Bates & Associates, Architects <br />E Drawings and Specifications as instruments of service are and shall remain <br />the property of the Architect. They are not to be used on other projects or <br />extensions to this project except by agreement in writing and with <br />appropriate compensation to the Architect. <br />Contractor is responsible for confirming and correlating dimensions at job <br />site; the Architect will not be responsible for construction means, methods, <br />techniques, sequences or procedures, or for safety precautions and <br />programs in connection with the project. <br />SITE/STORE #: <br />37745 <br />CONSTRUCTION MANAGER <br />CREIGHTON COMMERCIAL DEVELOPMENT <br />900 SW PINE ISLAND ROAD, SUITE 202 <br />CAPE CORAL, FL 33991 <br />TENANT <br />7-ELEVEN INC. <br />1722 ROUTH ST. SUITE 1000 DALLAS, TX 75201 <br />CONTACT: DANIELTUBB <br />STRUCTURAL CONSULTANT <br />SELECT STRUCTURAL <br />12573 NEW BRITTANY BLVD FORT MYERS, FL 33907 <br />CONTACT: SHAWN ANDERSON <br />MEP CONSULTANT <br />WALTER J. FITZGERALD, P.E. <br />2566 NEBRASKA AVE., PALM HARBOR, FL 34684 <br />CONTACT: (813) 785-7526 <br />�I <br />Architect Name - RYAN M FAUST <br />Architect Number - AR97905 <br />THE SEAL AND SIGNATURE APPLY ONLY TO THE DOCUMENT TO WHICH <br />THEY ARE AFFIXED AND WE EXPRESSLY DISCLAIM ANY RESPONSIBILITY FOR <br />ALL OTHER PLANS, SPECIFICATIONS, ESTIMATES, REPORTS OR OTHER <br />DOCUMENTS OR INSTRUMENTS RELATING TO OR INTENDED TO BE USED <br />FOR ANY PART OR. PARTS OF THE PROJECT. <br />REVISIONS <br />NO. DATE DESCRIPTION <br />A <br />PROJECT NUMBER: 16018 <br />RELEASE DATE: 03/31/2016 <br />REFLECTED CEILING PLAN <br />6 5 4 3 2 1 <br />