Laserfiche WebLink
GENERAL ACCESSIBILITY NOTES <br />GYP. BD. RETURNS @ <br />SIDES @ TOP <br />INSTALL TOP TRACK OF <br />SLIDING PASS THRU WINDOW <br />TO BOT. SIDE OF GYP. BD. <br />-FINISH CAULK EA. SIDE <br />1/4" FROSTED GLASS W/ <br />BEVELED HAND GRIP <br />INSTALL BOTTOM TRACK OF <br />SLIDING PASS THRU WINDOW <br />IN 1 3/16" x 9/16" DADO CUT INTO <br />TOP OF PLASTIC LAMINATE CAP <br />-FINISH CAULK EA. SIDE <br />1 1/4" PLASTIC LAMINATE <br />CAP BY MILLWORK SUPPLIER <br />MTL. STUD -SEE <br />PLAN FOR SIZE <br />PASS THRU DETAIL <br />SCALE: 3" = V-0" <br />PROVIDE BLOCKING <br />IN WALL AS REQ'D TO <br />ANCHOR MOUNTING <br />BRACKET (TYP.) <br />FINISH FLOOR LINE <br />a <br />c <br />is <br />u <br />FIRE EXTINGUISHER SPECIFICATION: <br />MANUFACTURER: JL INDUSTRIES, INC. <br />PRODUCT: FIRE EXTINGUISHER: <br />-'COSMIC' 10E <br />10 Ib. CAPACITY; 4A-80BC RATING <br />BRACKET: <br />- MARK 'MB846' WALL BRACKET <br />FIRE EXTINGUISHER DETAIL <br />SCALE: 1/2" = V-0" <br />c <br />c <br />WALL CONST. - <br />SEE WALL TYPES <br />BUILD WALL TIGHT <br />TO EXIST. FRAME <br />CONT. ALUM. TRIM <br />EACH SIDE <br />c <br />ALUMINUM TUBE - <br />VERIFY DEPTH <br />EXIST. WINDOW <br />FRAME BELOW <br />WALL CLOSURE DETAIL <br />SCALE: 1 1/2" = V-0" <br />X-RAY SUPPORT TO WITHSTAND 450 LBS. OF <br />WITHDRAW FORCE AND 100 LBS. OF SHEAR AT <br />EA. BOLT LOCATION. INSTALLATION BEHIND <br />FINISHED SURFACES. FOLLOW ANY AND ALL <br />VARIATIONS REQUIRED FOR LOCAL BUILDING <br />AND X-RAY RADIATION CONTROL STANDARDS. <br />4x4 POST <br />(6) #12 WIRES RAN <br />TO MASTER <br />CONTROL, LOCATED <br />OUTSIDE OF X-RAY <br />ROOM SEE DETAIL <br />D9A ON SHEET MD <br />:RRIFY WALL RATING IF <br />'PLICABLE. PROVIDE FIRE <br />IEATED BLOCKING AS REQ'D <br />3/4" PLYWOOD <br />44 JBOX MOUNTED <br />@ 42" A.F.F. TO <br />BOTTOM,CENTERED <br />BETWEEN 4x4 POST <br />5/8" GWB BOTH <br />SIDES DOUBLE GWB <br />INSIDE OF ROOM <br />BELMONT 096 X-RAY SUPPORT <br />SCALE: 1/2" = V-0" <br />RUN WIDTH OF WALL <br />i <br />ifl <br />VERRIFY WALL RATING IF <br />APPLICABLE. PROVIDE FIRE <br />TREATED BLOCKING AS REQ'D <br />(2) LAYERS 3/4" <br />PLYWOOD <br />20 GAUGE STEEL <br />WALL STUDS (16" <br />O.C.) <br />DEDICATED 20 AMP <br />220V ELEC. <br />CIRCUIT TWIST <br />LOCK OUTLET <br />(ELECTRICIAN TO <br />SUPPLY MALE END) <br />(CENTERED IN ROOM) <br />PLASTER RING WITH <br />2" CONDUIT OR <br />WALL CHASE RAN <br />ABOVE CEILING <br />WITH PULL STRING <br />(CENTERED IN ROOM) <br />5/8" GWB BOTH <br />SIDES DOUBLE GWB <br />INSIDE OF ROOM <br />PANORAMIC X-RAY SUPPORT <br />SCALE: 1/2" = V-0" <br />RUN WIDTH OF WALL <br />i <br />NZE, <br />0 <br />Lo <br />PLASMA TV SUPPORT <br />SCALE: 1/2" = V-0" <br />VERRIFY WALL RATING IF <br />APPLICABLE. PROVIDE FIRE <br />TREATED BLOCKING AS REQ'D <br />(2) LAYERS 3/4" <br />PLYWOOD <br />20 GAUGE STEEL <br />WALL STUDS (16" <br />O.C.) <br />PLASTIC JBOX AND <br />PLASTER RING AND <br />PULL STRING <br />ABOVE CEILING. - <br />SEE ELECTRICAL <br />PLANS <br />DUPLEX ELECTRICAL <br />OUTLET -SEE <br />ELECTRICAL PLANS <br />5/8" GWB BOTH <br />SIDES DOUBLE GWB <br />INSIDE OF ROOM <br />THRESHOLDS <br />1. FLOOR(S) OR LANDING(S) ARE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE <br />THRESHOLD OF THE DOORWAY. <br />2. PER 303.3 CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" IS BEVELED AT A GRADIENT NOT <br />TO EXCEED 1:2 <br />3. DOORMATS ARE SECURELY ATTACHED (ANCHORED OR RECESSED) AND HAVE A <br />LEVEL LOOP, LEVEL CUT/UNCUT PILE WITH PILE NOT EXCEEDING 1/2" IN HEIGHT. <br />4. EXPOSED EDGES OF DOORMAT(S) ARE FASTENED TO FLOOR SURFACES AND HAVE <br />TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. <br />DOORS <br />1. MINIMUM OF 3'-0" IN WIDTH, 6-8" IN HEIGHT. <br />2. OPENS A MINIMUM OF 90 DEGREES. <br />3. CLEAR WIDTH OF THE DOORWAY IS 32" MINIMUM. <br />4. DOUBLE DOORS / AUTOMATIC DOORS AT LEAST ONE DOOR MUST COMPLY WITH 1, 2 <br />AND 3 ABOVE. <br />5. BOTTOM 10" OF DOOR HAS A SMOOTH, UNINTERRUPTED SURFACE THAT ALLOWS <br />DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR <br />HAZARDOUS CONDITION. <br />NOTE: <br />WHERE NARROW FRAME DOORS ARE USED A 10" HIGH SMOOTH PANEL MUST BE <br />INSTALLED ON THE PUSH SIDE BOTTOM OF THE DOOR WHICH WILL ALLOW THE DOOR TO <br />BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS <br />CONDITION. <br />6. EFFORT TO OPERATE DOORS IS WITHIN PRESSURES ALLOWED. INTERIOR DOORS 5 <br />POUNDS MAXIMUM PRESSURE TO OPERATE. FIRE DOORS SEE APPROPRIATE <br />ADMINISTRATIVE AUTHORITY. <br />7. TWO DOORS IN A SERIES PROVIDE A MINIMUM OF 48" CLEAR SPACE FROM ANY DOOR, <br />IN ANY POSITION. <br />DOOR HARDWARE <br />1. EXIT DOORS ARE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY <br />SPECIAL KNOWLEDGE OR EFFORT. <br />2. LATCHING AND LOCKING DOORS THAT ARE HAND OPERATED ARE OPERABLE WITH A <br />SINGLE EFFORT (EX. LEVER TYPE, PANIC BARS OR PUSH-PULL TYPE). <br />3. OPENING HARDWARE IS NO HIGHER THAN 48 ABOVE FINISH FLOOR. <br />4. DOOR CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 <br />DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 <br />DEGREES SHALL BE 5 SECONDS MINIMUM. <br />5. HANDLES, PULL, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE <br />DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES <br />NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO <br />OPERATE. LEVER OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U- <br />SHAPED HANDLES ARE ACCEPTABLE DESIGNS. WHEN SLIDING DOORS ARE FULLY <br />OPEN, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. <br />HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NO <br />HIGHER THAN 48 INCHES A.F.F. <br />CLEAR SPACE AT DOORS <br />GENERAL REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A FLOOR OR <br />LANDING ON EACH SIDE OF A DOOR. <br />1. FLOOR OR LANDING ON EACH SIDE OF THE DOOR IS LEVEL AND CLEAR. <br />2. LEVEL AREA IN THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF 60" IN <br />LENGTH. <br />3. LEVEL AREA OPPOSITE THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF 42-48" <br />IN LENGTH, DEPENDING UPON DIRECTION OF APPROACH AND EXISTENCE OF LATCH <br />AND CLOSER. <br />4. SURFACE SLOPE OF THE LEVEL AREA DOES NOT EXCEED 1:50 GRADIENT (2%). <br />5. MINIMUM STRIKE SIDE CLEARANCE ON PULL SIDE OF DOOR IS PROVIDED AT <br />LANDING (PER 404.2.3.1). <br />6. MINIMUM LATCH SIDE CLEARANCE ON PUSH SIDE OF DOOR IS PROVIDED AT <br />LANDING (PER 404.2.3.1). <br />IDENTIFICATION SYMBOLS (FOR SANITARY FACILITIES) <br />1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS INSTALLED ON THE WALL <br />ADJACENT TO THE LATCH SIDE OF THE DOOR. THE BORDER DIMENSIONS OF THIS <br />PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. <br />NOTE: WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE <br />LEAF DOORS; SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY <br />2. VERBAL DESCRIPTION AS TO RESTROOM USAGE (I.E. MENS RESTROOM, ECT.) IS <br />PLACED DIRECTLY BELOW THE SYMBOL OF ACCESSIBILITY. <br />3. THE CHARACTERS AND BACKGROUND OF THE SIGN IS EGGSHELL, MATTE OR OTHER <br />NON -GLARE FINISH AND THE COLOR AND CONTRAST OF THE SIGN DISTINCTIVELY <br />CONTRASTS WITH THE COLOR AND CONTRAST OF THE WALL. <br />NOTE: THE REQUIRED COLOR OF THE SYMBOL OF ACCESSIBILITY CONSISTS OF A WHITE <br />FIGURE ON A BLUE BACKGROUND. HOWEVER, THE APPROPRIATE ENFORCEMENT <br />AGENCY MAY APPROVE SPECIAL SIGNS TO COMPLIMENT DECOR WHEN SUCH SIGNS <br />PROVIDE ADEQUATE DIRECTION TO INDIVIDUALS WITH DISABILITIES. <br />4. SIGNS ARE CENTERED ON THE WALL 60" A.F.F. AND 8" FROM EDGE OF SIGN TO EDGE <br />OF DOOR FRAME. <br />5. LETTERS AND NUMERALS ARE RAISED 1/32" ARE SANSSERIF UPPERCASE <br />CHARACTERS AND ARE ACCOMPANIED BY GRADE 2 BRAILLE. CHARACTERS ARE A <br />MINIMUM 5/8" HIGH AND A MAXIMUM OF 2" HIGH. <br />6. MOUNTING LOCATION ALLOWS A PERSON TO APPROACH WITHIN 3" OF THE SIGNAGE <br />WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING <br />OF A DOOR. <br />7. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR <br />FLOOR AREA 18" X 18" MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS <br />PROVIDED BEYOND THE ARC OF ANY DOOR SWING THE CLOSED POSITION AND 45 <br />DEGREE OPEN POSITION. <br />SANITATION FACILITIES <br />1. ACCESSIBLE UNITS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY. <br />2. EXCEPT AT DOORS, THE MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE IN <br />FACILITY IS 36". <br />3. ENTRY DOOR HAS PUSH AND PULL FUNCTION (NO LATCHING DEVICE) WITH CLOSER. <br />4. SUFFICIENT SPACE FOR WHEELCHAIR MEASURING 30" X 48" TO ENTER ROOM AND <br />PERMIT THE DOOR TO CLOSE IS PROVIDED. <br />5. A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60" DIAMETER CIRCLE IS <br />PROVIDED WITHIN THE SANITARY FACILITY ROOM. <br />6. 60" SPACE IS CLEAR OF OBJECTS FROM THE FLOOR TO A HEIGHT OF 27". <br />7. CLEAR FLOOR SPACE FOR WATER CLOSETS IN STALLS SHALL COMPLY WITH <br />DIAGRAMS ON THIS SHEET. CLEAR FLOOR SPACE MAY BE ARRANGED TO ALLOW <br />EITHER A RIGHT HANDED OR A LEFT HANDED APPROACH. <br />8. 18 BETWEEN CENTER OF WATER CLOSET AND SIDE -WALL CORNER. <br />9. TOILET SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. <br />10. TOP OF TOILET SEAT IS 17"-19" FROM FLOOR SURFACE. <br />11. FLUSH VALVE IS ON WIDE SIDE OF TOILET AREA. <br />12. 44" MAXIMUM FROM FLOOR TO FLUSH VALVE. <br />13. 5 LB. MAXIMUM FORCE TO OPERATE FLUSH VALVE. <br />14. WALLS WITHIN COMPARTMENT ARE SMOOTH, HARD AND NONABSORBENT TO 48 IN <br />HEIGHT AND ARE NOT ADVERSELY AFFECTED BY MOISTURE. <br />15. FLOOR SURFACES OF TOILET ROOM ARE SMOOTH, HARD AND NON-ABSORBANT. <br />BASE SHALL EXTEND UPWARD A MINIMUM OF 6" ONTO WALLS. <br />16. SIDE GRAB BAR IS A MINIMUM OF 42" LONG. <br />17. THE FORWARD END OF THE GRAB BAR IS LOCATED A MINIMUM OF 54" FROM THE <br />BACK WALL. <br />18. SIDE GRAB BAR BEGINS A MAXIMUM OF 12" FROM THE REAR WALL. <br />19. REAR GRAB BAR IS A MINIMUM 48" LONG WITH THE ADDITIONAL LENGTH PROVIDED <br />ON THE TRANSFER SIDE OF THE WATER CLOSET. <br />20. REAR GRAB BAR BEGINS A MAXIMUM OF 6" FROM THE CORNER OF THE WALL ON THE <br />TOILET SIDE. <br />21. DIAMETER OF THE GRAB BAR(S) IS 1 1/4" -1 1/2" OR SHAPE PROVIDES EQUIVALENT <br />GRIPPING SURFACE. <br />22. CLEARANCE BETWEEN THE GRAB BAR(S) AND WALL IS 1 1/2" AND PARALLEL TO <br />FLOOR (FOR TANK TYPE TOILETS, 36" MAY BE ALLOWED IF TANK OBSTRUCTS <br />PLACEMENT OF BAR). <br />23. GRAB BARS ARE MOUNTED AT 33" TO CENTER OF BAR ABOVE. <br />24. BARS ARE SMOOTH WITH A MINIMUM RADIUS OF 1/8". <br />25. MINIMUM STRUCTURAL STRENGTH OF GRAB BAR(S) WILL SUPPORT A 250 LB. POINT <br />LOAD. <br />26. GRAB BARS DO NOT ROTATE WITHIN THEIR FITTINGS. <br />27. SURFACE OF WALL ADJACENT TO GRAB BAR(S) IS FREE OF SHARP OR ABRASIVE <br />ELEMENTS. <br />28. TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 309.4 AND SHALL BE 7 <br />MINIMUM AND 9 MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE <br />CENTER LINE OF THE DISPENSER. <br />29. THE OUTLET OF THE DISPENSER SHALL BE 14" MINIMUM AND 19" MAXIMUM ABOVE <br />THE FLOOR. THERE SHALL BE A CLEARANCE OF 1 1/2" MINIMUM BELOW THE GRAB <br />BAY. <br />30. DISPENSERS SHALL NOT BE A TYPE THAT CONTROL DELIVERY OR DO NOT ALLOW <br />CONTINUOUS PAPER FLOW. <br />LAVATORIES <br />1. MINIMUM 30" X 48" CLEAR SPACE IS PROVIDED IN FRONT OF LAVATORY THAT <br />ALLOWS FORWARD APPROACH. <br />2. REQUIRED CLEAR SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE AND <br />EXTENDS A MAXIMUM OF 19" UNDERNEATH THE LAVATORY. <br />3. 34" MAXIMUM HEIGHT OF RIM OR COUNTER ABOVE FLOOR SURFACE. <br />4. 29" MINIMUM CLEARANCE FROM BOTTOM OF APRON TO THE FLOOR. <br />5. KNEE CLEARANCE UNDER FRONT LIP IS A MINIMUM OF 27" HIGH, 30" WIDE, AND <br />EXTENDS A MINIMUM OF 8" IN DEPTH FROM THE FRONT OF THE LAVATORY. <br />6. TOE CLEARANCE UNDER LAVATORY IS A MINIMUM OF 9" HIGH, 30" WIDE, AND <br />EXTENDS A MINIMUM OF 17" IN DEPTH FROM THE FRONT OF THE LAVATORY. <br />7. DRAIN AND HOT WATER PIPING IS INSULATED OR CONFIGURED TO PREVENT <br />CONTACT. <br />8. THERE ARE NO SHARP OR ABRASIVE ELEMENTS UNDER LAVATORY. <br />9. FAUCETS ARE LEVER TYPE, ELECTRONICALLY ACTIVATED OR APPROVED SELF <br />CLOSING VALVES (MIN. 10 SECONDS OPEN FLOW). <br />10. FAUCETS ARE OPERABLE WITH ONE HAND AND DO NOT REQUIRE TIGHT GRASPING, <br />PINCHING OR TWISTING OF THE WRIST. <br />11. 5 LB. MAXIMUM FORCE REQUIRED TO ACTIVATE CONTROLS. <br />WATER CLOSETS <br />1. 30" WIDE X 48" DEEP MINIMUM CLEAR ACCESS IN FRONT OF FIXTURE (ONE FIXTURE <br />ONLY REQUIRED). <br />2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS <br />OR OVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR <br />FLOOR SPACE. <br />3. 44" MAXIMUM HEIGHT OF FLUSH VALVE ABOVE FLOOR. <br />4. 5 LB. MAXIMUM PRESSURE TO OPERATE FLUSH VALVE. <br />5. FLOOR SURFACES ARE SMOOTH, HARD AND NON -ABSORBENT EXTENDING UPWARD A <br />MINIMUM OF 6" ONTO THE WALLS. <br />6. WALLS WITHIN 24" OF FRONT AND SIDES OF URINAL ARE SMOOTH, HARD AND NON - <br />ABSORBENT TO 48" IN HEIGHT AND ARE NOT ADVERSELY AFFECTED BY MOISTURE. <br />ACCESSORIES IN SANITARY FACILITIES <br />1. MINIMUM 30 X 48 CLEAR FLOOR OR GROUND SPACE IS PROVIDED TO ALLOW <br />FORWARD OR PARALLEL APPROACH TO ACCESSORIES. <br />2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS <br />OR OVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR <br />FLOOR SPACE. <br />3. MIRROR(S) IS MOUNTED WITH THE BOTTOM OF THE REFLECTIVE SURFACE EDGE NO <br />HIGHER THAN 40" A.F.F. AND WITH THE TOP OF THE REFLECTIVE SURFACE EDGE NO <br />LOWER THAN 74" A.F.F. <br />4. OPERABLE PARTS (INCLUDING COIN SLOTS) OF ALL FIXTURES OR ACCESSORIES ARE <br />LOCATED A MAXIMUM OF 40" ABOVE FLOOR (I.E. SOAP DISPENSERS, TOWELS, TOILET <br />SEAT COVERS, AUTO -DRYERS, SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, <br />ECT.). <br />5. CONTROLS AND OPERATING MECHANISMS ARE OPERABLE WITH ONE HAND AND DO <br />NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. <br />6. THE FORCE TO ACTIVATE CONTROLS IS 5 LB. MAXIMUM. <br />EXCEL <br />ENGINEERINCInc. <br />100 CAMELOT DRIVE <br />FOND DU LAC, WI 54935 <br />PHONE: (920) 926-"W <br />FAX: (920) 926.9801 <br />Always a Better Plan <br />L0 <br />O <br />>- <br />V) <br />Q <br />Z <br />jD:� <br />W <br />:2 <br />ry <br />Q <br />O <br />>- <br />W <br />W <br />C <br />Q <br />>> <br />> <br />Z <br />Q <br />W <br />W <br />W <br />z <br />12 <br />f-Y <br />U <br />Lj <br />Q <br />(n <br />z <br />r <br />W <br />U <br />Q <br />�.. <br />LL p <br />Z <br />i>-- <br />LLJ <br />Q <br />cn <br />Z w <br />V) <br />� <br />cn DO Q <br />O Q N W <br />Q <br />I <br />N <br />LLJ <br />1..1_ <br />W <br />D <br />~ <br />Z <br />L iJ <br />0 <br />O <br />"t <br />U <br />El:f <br />m <br />W <br />W <br />D <br />J <br />J <br />J <br />. . <br />J <br />Q <br />cn <br />a <br />z <br />J <br />J <br />U <br />W <br />J <br />J <br />W <br />c) <br />z <br />p <br />W <br />= <br />_ <br />�'�/ <br />L_L <br />W <br />in <br />W <br />W <br />O <br />� <br />� <br />W <br />Q <br />N <br />I�_ <br />N <br />SHEET ISSUE: <br />NOVEMBER 23, 2009 <br />SEE TITLE SHEET TO CONFIM <br />THAT THIS SHEET HAS BEEN <br />ISSUED FOR CONSTRUCTION <br />REVISIONS: <br />DATE: <br />NOV. 23, 2009 <br />z <br />JOB NUMBER: <br />z <br />914790 <br />w <br />w <br />Z SHEET <br />z. <br />w <br />J <br />w <br />U <br />A %5. <br />0 <br />D0 <br />