GENERAL ACCESSIBILITY NOTES
<br />GYP. BD. RETURNS @
<br />SIDES @ TOP
<br />INSTALL TOP TRACK OF
<br />SLIDING PASS THRU WINDOW
<br />TO BOT. SIDE OF GYP. BD.
<br />-FINISH CAULK EA. SIDE
<br />1/4" FROSTED GLASS W/
<br />BEVELED HAND GRIP
<br />INSTALL BOTTOM TRACK OF
<br />SLIDING PASS THRU WINDOW
<br />IN 1 3/16" x 9/16" DADO CUT INTO
<br />TOP OF PLASTIC LAMINATE CAP
<br />-FINISH CAULK EA. SIDE
<br />1 1/4" PLASTIC LAMINATE
<br />CAP BY MILLWORK SUPPLIER
<br />MTL. STUD -SEE
<br />PLAN FOR SIZE
<br />PASS THRU DETAIL
<br />SCALE: 3" = V-0"
<br />PROVIDE BLOCKING
<br />IN WALL AS REQ'D TO
<br />ANCHOR MOUNTING
<br />BRACKET (TYP.)
<br />FINISH FLOOR LINE
<br />a
<br />c
<br />is
<br />u
<br />FIRE EXTINGUISHER SPECIFICATION:
<br />MANUFACTURER: JL INDUSTRIES, INC.
<br />PRODUCT: FIRE EXTINGUISHER:
<br />-'COSMIC' 10E
<br />10 Ib. CAPACITY; 4A-80BC RATING
<br />BRACKET:
<br />- MARK 'MB846' WALL BRACKET
<br />FIRE EXTINGUISHER DETAIL
<br />SCALE: 1/2" = V-0"
<br />c
<br />c
<br />WALL CONST. -
<br />SEE WALL TYPES
<br />BUILD WALL TIGHT
<br />TO EXIST. FRAME
<br />CONT. ALUM. TRIM
<br />EACH SIDE
<br />c
<br />ALUMINUM TUBE -
<br />VERIFY DEPTH
<br />EXIST. WINDOW
<br />FRAME BELOW
<br />WALL CLOSURE DETAIL
<br />SCALE: 1 1/2" = V-0"
<br />X-RAY SUPPORT TO WITHSTAND 450 LBS. OF
<br />WITHDRAW FORCE AND 100 LBS. OF SHEAR AT
<br />EA. BOLT LOCATION. INSTALLATION BEHIND
<br />FINISHED SURFACES. FOLLOW ANY AND ALL
<br />VARIATIONS REQUIRED FOR LOCAL BUILDING
<br />AND X-RAY RADIATION CONTROL STANDARDS.
<br />4x4 POST
<br />(6) #12 WIRES RAN
<br />TO MASTER
<br />CONTROL, LOCATED
<br />OUTSIDE OF X-RAY
<br />ROOM SEE DETAIL
<br />D9A ON SHEET MD
<br />:RRIFY WALL RATING IF
<br />'PLICABLE. PROVIDE FIRE
<br />IEATED BLOCKING AS REQ'D
<br />3/4" PLYWOOD
<br />44 JBOX MOUNTED
<br />@ 42" A.F.F. TO
<br />BOTTOM,CENTERED
<br />BETWEEN 4x4 POST
<br />5/8" GWB BOTH
<br />SIDES DOUBLE GWB
<br />INSIDE OF ROOM
<br />BELMONT 096 X-RAY SUPPORT
<br />SCALE: 1/2" = V-0"
<br />RUN WIDTH OF WALL
<br />i
<br />ifl
<br />VERRIFY WALL RATING IF
<br />APPLICABLE. PROVIDE FIRE
<br />TREATED BLOCKING AS REQ'D
<br />(2) LAYERS 3/4"
<br />PLYWOOD
<br />20 GAUGE STEEL
<br />WALL STUDS (16"
<br />O.C.)
<br />DEDICATED 20 AMP
<br />220V ELEC.
<br />CIRCUIT TWIST
<br />LOCK OUTLET
<br />(ELECTRICIAN TO
<br />SUPPLY MALE END)
<br />(CENTERED IN ROOM)
<br />PLASTER RING WITH
<br />2" CONDUIT OR
<br />WALL CHASE RAN
<br />ABOVE CEILING
<br />WITH PULL STRING
<br />(CENTERED IN ROOM)
<br />5/8" GWB BOTH
<br />SIDES DOUBLE GWB
<br />INSIDE OF ROOM
<br />PANORAMIC X-RAY SUPPORT
<br />SCALE: 1/2" = V-0"
<br />RUN WIDTH OF WALL
<br />i
<br />NZE,
<br />0
<br />Lo
<br />PLASMA TV SUPPORT
<br />SCALE: 1/2" = V-0"
<br />VERRIFY WALL RATING IF
<br />APPLICABLE. PROVIDE FIRE
<br />TREATED BLOCKING AS REQ'D
<br />(2) LAYERS 3/4"
<br />PLYWOOD
<br />20 GAUGE STEEL
<br />WALL STUDS (16"
<br />O.C.)
<br />PLASTIC JBOX AND
<br />PLASTER RING AND
<br />PULL STRING
<br />ABOVE CEILING. -
<br />SEE ELECTRICAL
<br />PLANS
<br />DUPLEX ELECTRICAL
<br />OUTLET -SEE
<br />ELECTRICAL PLANS
<br />5/8" GWB BOTH
<br />SIDES DOUBLE GWB
<br />INSIDE OF ROOM
<br />THRESHOLDS
<br />1. FLOOR(S) OR LANDING(S) ARE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE
<br />THRESHOLD OF THE DOORWAY.
<br />2. PER 303.3 CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" IS BEVELED AT A GRADIENT NOT
<br />TO EXCEED 1:2
<br />3. DOORMATS ARE SECURELY ATTACHED (ANCHORED OR RECESSED) AND HAVE A
<br />LEVEL LOOP, LEVEL CUT/UNCUT PILE WITH PILE NOT EXCEEDING 1/2" IN HEIGHT.
<br />4. EXPOSED EDGES OF DOORMAT(S) ARE FASTENED TO FLOOR SURFACES AND HAVE
<br />TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE.
<br />DOORS
<br />1. MINIMUM OF 3'-0" IN WIDTH, 6-8" IN HEIGHT.
<br />2. OPENS A MINIMUM OF 90 DEGREES.
<br />3. CLEAR WIDTH OF THE DOORWAY IS 32" MINIMUM.
<br />4. DOUBLE DOORS / AUTOMATIC DOORS AT LEAST ONE DOOR MUST COMPLY WITH 1, 2
<br />AND 3 ABOVE.
<br />5. BOTTOM 10" OF DOOR HAS A SMOOTH, UNINTERRUPTED SURFACE THAT ALLOWS
<br />DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR
<br />HAZARDOUS CONDITION.
<br />NOTE:
<br />WHERE NARROW FRAME DOORS ARE USED A 10" HIGH SMOOTH PANEL MUST BE
<br />INSTALLED ON THE PUSH SIDE BOTTOM OF THE DOOR WHICH WILL ALLOW THE DOOR TO
<br />BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS
<br />CONDITION.
<br />6. EFFORT TO OPERATE DOORS IS WITHIN PRESSURES ALLOWED. INTERIOR DOORS 5
<br />POUNDS MAXIMUM PRESSURE TO OPERATE. FIRE DOORS SEE APPROPRIATE
<br />ADMINISTRATIVE AUTHORITY.
<br />7. TWO DOORS IN A SERIES PROVIDE A MINIMUM OF 48" CLEAR SPACE FROM ANY DOOR,
<br />IN ANY POSITION.
<br />DOOR HARDWARE
<br />1. EXIT DOORS ARE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY
<br />SPECIAL KNOWLEDGE OR EFFORT.
<br />2. LATCHING AND LOCKING DOORS THAT ARE HAND OPERATED ARE OPERABLE WITH A
<br />SINGLE EFFORT (EX. LEVER TYPE, PANIC BARS OR PUSH-PULL TYPE).
<br />3. OPENING HARDWARE IS NO HIGHER THAN 48 ABOVE FINISH FLOOR.
<br />4. DOOR CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90
<br />DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12
<br />DEGREES SHALL BE 5 SECONDS MINIMUM.
<br />5. HANDLES, PULL, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE
<br />DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES
<br />NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO
<br />OPERATE. LEVER OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U-
<br />SHAPED HANDLES ARE ACCEPTABLE DESIGNS. WHEN SLIDING DOORS ARE FULLY
<br />OPEN, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES.
<br />HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NO
<br />HIGHER THAN 48 INCHES A.F.F.
<br />CLEAR SPACE AT DOORS
<br />GENERAL REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A FLOOR OR
<br />LANDING ON EACH SIDE OF A DOOR.
<br />1. FLOOR OR LANDING ON EACH SIDE OF THE DOOR IS LEVEL AND CLEAR.
<br />2. LEVEL AREA IN THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF 60" IN
<br />LENGTH.
<br />3. LEVEL AREA OPPOSITE THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF 42-48"
<br />IN LENGTH, DEPENDING UPON DIRECTION OF APPROACH AND EXISTENCE OF LATCH
<br />AND CLOSER.
<br />4. SURFACE SLOPE OF THE LEVEL AREA DOES NOT EXCEED 1:50 GRADIENT (2%).
<br />5. MINIMUM STRIKE SIDE CLEARANCE ON PULL SIDE OF DOOR IS PROVIDED AT
<br />LANDING (PER 404.2.3.1).
<br />6. MINIMUM LATCH SIDE CLEARANCE ON PUSH SIDE OF DOOR IS PROVIDED AT
<br />LANDING (PER 404.2.3.1).
<br />IDENTIFICATION SYMBOLS (FOR SANITARY FACILITIES)
<br />1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS INSTALLED ON THE WALL
<br />ADJACENT TO THE LATCH SIDE OF THE DOOR. THE BORDER DIMENSIONS OF THIS
<br />PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT.
<br />NOTE: WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE
<br />LEAF DOORS; SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY
<br />2. VERBAL DESCRIPTION AS TO RESTROOM USAGE (I.E. MENS RESTROOM, ECT.) IS
<br />PLACED DIRECTLY BELOW THE SYMBOL OF ACCESSIBILITY.
<br />3. THE CHARACTERS AND BACKGROUND OF THE SIGN IS EGGSHELL, MATTE OR OTHER
<br />NON -GLARE FINISH AND THE COLOR AND CONTRAST OF THE SIGN DISTINCTIVELY
<br />CONTRASTS WITH THE COLOR AND CONTRAST OF THE WALL.
<br />NOTE: THE REQUIRED COLOR OF THE SYMBOL OF ACCESSIBILITY CONSISTS OF A WHITE
<br />FIGURE ON A BLUE BACKGROUND. HOWEVER, THE APPROPRIATE ENFORCEMENT
<br />AGENCY MAY APPROVE SPECIAL SIGNS TO COMPLIMENT DECOR WHEN SUCH SIGNS
<br />PROVIDE ADEQUATE DIRECTION TO INDIVIDUALS WITH DISABILITIES.
<br />4. SIGNS ARE CENTERED ON THE WALL 60" A.F.F. AND 8" FROM EDGE OF SIGN TO EDGE
<br />OF DOOR FRAME.
<br />5. LETTERS AND NUMERALS ARE RAISED 1/32" ARE SANSSERIF UPPERCASE
<br />CHARACTERS AND ARE ACCOMPANIED BY GRADE 2 BRAILLE. CHARACTERS ARE A
<br />MINIMUM 5/8" HIGH AND A MAXIMUM OF 2" HIGH.
<br />6. MOUNTING LOCATION ALLOWS A PERSON TO APPROACH WITHIN 3" OF THE SIGNAGE
<br />WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING
<br />OF A DOOR.
<br />7. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR
<br />FLOOR AREA 18" X 18" MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS
<br />PROVIDED BEYOND THE ARC OF ANY DOOR SWING THE CLOSED POSITION AND 45
<br />DEGREE OPEN POSITION.
<br />SANITATION FACILITIES
<br />1. ACCESSIBLE UNITS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF
<br />ACCESSIBILITY.
<br />2. EXCEPT AT DOORS, THE MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE IN
<br />FACILITY IS 36".
<br />3. ENTRY DOOR HAS PUSH AND PULL FUNCTION (NO LATCHING DEVICE) WITH CLOSER.
<br />4. SUFFICIENT SPACE FOR WHEELCHAIR MEASURING 30" X 48" TO ENTER ROOM AND
<br />PERMIT THE DOOR TO CLOSE IS PROVIDED.
<br />5. A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60" DIAMETER CIRCLE IS
<br />PROVIDED WITHIN THE SANITARY FACILITY ROOM.
<br />6. 60" SPACE IS CLEAR OF OBJECTS FROM THE FLOOR TO A HEIGHT OF 27".
<br />7. CLEAR FLOOR SPACE FOR WATER CLOSETS IN STALLS SHALL COMPLY WITH
<br />DIAGRAMS ON THIS SHEET. CLEAR FLOOR SPACE MAY BE ARRANGED TO ALLOW
<br />EITHER A RIGHT HANDED OR A LEFT HANDED APPROACH.
<br />8. 18 BETWEEN CENTER OF WATER CLOSET AND SIDE -WALL CORNER.
<br />9. TOILET SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION.
<br />10. TOP OF TOILET SEAT IS 17"-19" FROM FLOOR SURFACE.
<br />11. FLUSH VALVE IS ON WIDE SIDE OF TOILET AREA.
<br />12. 44" MAXIMUM FROM FLOOR TO FLUSH VALVE.
<br />13. 5 LB. MAXIMUM FORCE TO OPERATE FLUSH VALVE.
<br />14. WALLS WITHIN COMPARTMENT ARE SMOOTH, HARD AND NONABSORBENT TO 48 IN
<br />HEIGHT AND ARE NOT ADVERSELY AFFECTED BY MOISTURE.
<br />15. FLOOR SURFACES OF TOILET ROOM ARE SMOOTH, HARD AND NON-ABSORBANT.
<br />BASE SHALL EXTEND UPWARD A MINIMUM OF 6" ONTO WALLS.
<br />16. SIDE GRAB BAR IS A MINIMUM OF 42" LONG.
<br />17. THE FORWARD END OF THE GRAB BAR IS LOCATED A MINIMUM OF 54" FROM THE
<br />BACK WALL.
<br />18. SIDE GRAB BAR BEGINS A MAXIMUM OF 12" FROM THE REAR WALL.
<br />19. REAR GRAB BAR IS A MINIMUM 48" LONG WITH THE ADDITIONAL LENGTH PROVIDED
<br />ON THE TRANSFER SIDE OF THE WATER CLOSET.
<br />20. REAR GRAB BAR BEGINS A MAXIMUM OF 6" FROM THE CORNER OF THE WALL ON THE
<br />TOILET SIDE.
<br />21. DIAMETER OF THE GRAB BAR(S) IS 1 1/4" -1 1/2" OR SHAPE PROVIDES EQUIVALENT
<br />GRIPPING SURFACE.
<br />22. CLEARANCE BETWEEN THE GRAB BAR(S) AND WALL IS 1 1/2" AND PARALLEL TO
<br />FLOOR (FOR TANK TYPE TOILETS, 36" MAY BE ALLOWED IF TANK OBSTRUCTS
<br />PLACEMENT OF BAR).
<br />23. GRAB BARS ARE MOUNTED AT 33" TO CENTER OF BAR ABOVE.
<br />24. BARS ARE SMOOTH WITH A MINIMUM RADIUS OF 1/8".
<br />25. MINIMUM STRUCTURAL STRENGTH OF GRAB BAR(S) WILL SUPPORT A 250 LB. POINT
<br />LOAD.
<br />26. GRAB BARS DO NOT ROTATE WITHIN THEIR FITTINGS.
<br />27. SURFACE OF WALL ADJACENT TO GRAB BAR(S) IS FREE OF SHARP OR ABRASIVE
<br />ELEMENTS.
<br />28. TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 309.4 AND SHALL BE 7
<br />MINIMUM AND 9 MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE
<br />CENTER LINE OF THE DISPENSER.
<br />29. THE OUTLET OF THE DISPENSER SHALL BE 14" MINIMUM AND 19" MAXIMUM ABOVE
<br />THE FLOOR. THERE SHALL BE A CLEARANCE OF 1 1/2" MINIMUM BELOW THE GRAB
<br />BAY.
<br />30. DISPENSERS SHALL NOT BE A TYPE THAT CONTROL DELIVERY OR DO NOT ALLOW
<br />CONTINUOUS PAPER FLOW.
<br />LAVATORIES
<br />1. MINIMUM 30" X 48" CLEAR SPACE IS PROVIDED IN FRONT OF LAVATORY THAT
<br />ALLOWS FORWARD APPROACH.
<br />2. REQUIRED CLEAR SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE AND
<br />EXTENDS A MAXIMUM OF 19" UNDERNEATH THE LAVATORY.
<br />3. 34" MAXIMUM HEIGHT OF RIM OR COUNTER ABOVE FLOOR SURFACE.
<br />4. 29" MINIMUM CLEARANCE FROM BOTTOM OF APRON TO THE FLOOR.
<br />5. KNEE CLEARANCE UNDER FRONT LIP IS A MINIMUM OF 27" HIGH, 30" WIDE, AND
<br />EXTENDS A MINIMUM OF 8" IN DEPTH FROM THE FRONT OF THE LAVATORY.
<br />6. TOE CLEARANCE UNDER LAVATORY IS A MINIMUM OF 9" HIGH, 30" WIDE, AND
<br />EXTENDS A MINIMUM OF 17" IN DEPTH FROM THE FRONT OF THE LAVATORY.
<br />7. DRAIN AND HOT WATER PIPING IS INSULATED OR CONFIGURED TO PREVENT
<br />CONTACT.
<br />8. THERE ARE NO SHARP OR ABRASIVE ELEMENTS UNDER LAVATORY.
<br />9. FAUCETS ARE LEVER TYPE, ELECTRONICALLY ACTIVATED OR APPROVED SELF
<br />CLOSING VALVES (MIN. 10 SECONDS OPEN FLOW).
<br />10. FAUCETS ARE OPERABLE WITH ONE HAND AND DO NOT REQUIRE TIGHT GRASPING,
<br />PINCHING OR TWISTING OF THE WRIST.
<br />11. 5 LB. MAXIMUM FORCE REQUIRED TO ACTIVATE CONTROLS.
<br />WATER CLOSETS
<br />1. 30" WIDE X 48" DEEP MINIMUM CLEAR ACCESS IN FRONT OF FIXTURE (ONE FIXTURE
<br />ONLY REQUIRED).
<br />2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS
<br />OR OVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR
<br />FLOOR SPACE.
<br />3. 44" MAXIMUM HEIGHT OF FLUSH VALVE ABOVE FLOOR.
<br />4. 5 LB. MAXIMUM PRESSURE TO OPERATE FLUSH VALVE.
<br />5. FLOOR SURFACES ARE SMOOTH, HARD AND NON -ABSORBENT EXTENDING UPWARD A
<br />MINIMUM OF 6" ONTO THE WALLS.
<br />6. WALLS WITHIN 24" OF FRONT AND SIDES OF URINAL ARE SMOOTH, HARD AND NON -
<br />ABSORBENT TO 48" IN HEIGHT AND ARE NOT ADVERSELY AFFECTED BY MOISTURE.
<br />ACCESSORIES IN SANITARY FACILITIES
<br />1. MINIMUM 30 X 48 CLEAR FLOOR OR GROUND SPACE IS PROVIDED TO ALLOW
<br />FORWARD OR PARALLEL APPROACH TO ACCESSORIES.
<br />2. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE ADJOINS
<br />OR OVERLAPS AN ACCESSIBLE ROUTE OR ADJOINS ANOTHER WHEELCHAIR CLEAR
<br />FLOOR SPACE.
<br />3. MIRROR(S) IS MOUNTED WITH THE BOTTOM OF THE REFLECTIVE SURFACE EDGE NO
<br />HIGHER THAN 40" A.F.F. AND WITH THE TOP OF THE REFLECTIVE SURFACE EDGE NO
<br />LOWER THAN 74" A.F.F.
<br />4. OPERABLE PARTS (INCLUDING COIN SLOTS) OF ALL FIXTURES OR ACCESSORIES ARE
<br />LOCATED A MAXIMUM OF 40" ABOVE FLOOR (I.E. SOAP DISPENSERS, TOWELS, TOILET
<br />SEAT COVERS, AUTO -DRYERS, SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES,
<br />ECT.).
<br />5. CONTROLS AND OPERATING MECHANISMS ARE OPERABLE WITH ONE HAND AND DO
<br />NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST.
<br />6. THE FORCE TO ACTIVATE CONTROLS IS 5 LB. MAXIMUM.
<br />EXCEL
<br />ENGINEERINCInc.
<br />100 CAMELOT DRIVE
<br />FOND DU LAC, WI 54935
<br />PHONE: (920) 926-"W
<br />FAX: (920) 926.9801
<br />Always a Better Plan
<br />L0
<br />O
<br />>-
<br />V)
<br />Q
<br />Z
<br />jD:�
<br />W
<br />:2
<br />ry
<br />Q
<br />O
<br />>-
<br />W
<br />W
<br />C
<br />Q
<br />>>
<br />>
<br />Z
<br />Q
<br />W
<br />W
<br />W
<br />z
<br />12
<br />f-Y
<br />U
<br />Lj
<br />Q
<br />(n
<br />z
<br />r
<br />W
<br />U
<br />Q
<br />�..
<br />LL p
<br />Z
<br />i>--
<br />LLJ
<br />Q
<br />cn
<br />Z w
<br />V)
<br />�
<br />cn DO Q
<br />O Q N W
<br />Q
<br />I
<br />N
<br />LLJ
<br />1..1_
<br />W
<br />D
<br />~
<br />Z
<br />L iJ
<br />0
<br />O
<br />"t
<br />U
<br />El:f
<br />m
<br />W
<br />W
<br />D
<br />J
<br />J
<br />J
<br />. .
<br />J
<br />Q
<br />cn
<br />a
<br />z
<br />J
<br />J
<br />U
<br />W
<br />J
<br />J
<br />W
<br />c)
<br />z
<br />p
<br />W
<br />=
<br />_
<br />�'�/
<br />L_L
<br />W
<br />in
<br />W
<br />W
<br />O
<br />�
<br />�
<br />W
<br />Q
<br />N
<br />I�_
<br />N
<br />SHEET ISSUE:
<br />NOVEMBER 23, 2009
<br />SEE TITLE SHEET TO CONFIM
<br />THAT THIS SHEET HAS BEEN
<br />ISSUED FOR CONSTRUCTION
<br />REVISIONS:
<br />DATE:
<br />NOV. 23, 2009
<br />z
<br />JOB NUMBER:
<br />z
<br />914790
<br />w
<br />w
<br />Z SHEET
<br />z.
<br />w
<br />J
<br />w
<br />U
<br />A %5.
<br />0
<br />D0
<br />
|