Laserfiche WebLink
10'-4" <br />40" <br />54" MIN. <br />12" <br />MAX. 42" <br />11 <br />co <br />� � o <br />FLUSH CONTROLS TO BE <br />MOUNTED TO THE WIDE <br />SIDE OF THE TOILET AREA <br />mQ <br />O Lu <br />d <br />SIDE VIEW FRONT VIEW <br />O O O <br />1 1/2"0 GRAB BAR 1 1/2"e GRAB BAR TOILET TISSUE DISPENSER <br />MODEL NUMBER: B-6806 MODEL NUMBER: B-6806 MODEL NUMBER: B-2740 <br />SATIN STAINLESS STEEL SATIN STAINLESS STEEL ALUMINUM W/ SATIN FINISH <br />BY LANDLORD BYLANDLORD BY LANDLORD <br />15" MIN. 7" MIN. <br />LL DEPT <br />� 24" <br />v rvi <br />N M <br />8" MIN. Ike 6" MAX. <br />KNEE CLR. TOE CLR. <br />O O 0 <br />7 <br />MIRROR LIQUID SOAP DISPENSER <br />MODEL NUMBER:B-290 SUPPLIED BY ASPEN DENTAL WALL HUNG LAVATORY <br />SATIN STAINLESS STEEL INSTALLED BE G.C. BYLANDLORD <br />BY LANDLORD <br />GENERAL NOTES NEW WORK: <br />1. ALL CONTRACTORS HIRED BY LANDLORD AND TENANT OR <br />TENANTS CONTRACTORS TO BE LICENSED CONTRACTORS AND <br />PROVIDE W/ PROOF OF INSURANCE (CERTIFICATES) <br />2. GEN. CONTR. VERIFY W/ LANDLORD & TENANT THAT ALL ELEC. <br />STUBS/ CONDUIT AND ALL PLUMBING BELOW GRADE IS <br />INSTALLED PRIOR TO CONCRETE SLAB BEING POURED. <br />3. GEN. CONTR. TO VERIFY ALL REQUIRED BLOCKING W/ OWNER <br />FOR OWNERS EQUIP. (IE: EQUIP. TOILET ACCESSORIES, ETC). <br />4. ALL CONTT. TO CONFORM W/ LOCAL STATE BUILDING CODES <br />AND ORDINANCES. <br />5. ALL CONST. TO CONFORM W/ ADA STANDARD <br />FOR ACCESSIBILITY. <br />6. ALL DOOR OFFSETS (HINGE SIDE) TO BE A MIN. OF 4" TYP. <br />7. ANY ROOM WITH SERVICE SINKS TO BE PROVIDED WITH <br />EXHAUST VENTILATION PER STATE CODE. VERIFY WITH HVAC <br />DESIGN DRAWINGS. <br />8. ALL MECH. EQUIP. TO BE DIRECT VENT SEALED COMBUSTION <br />- OR ELECTRIC. WATER HEATER EXACT LOCATION TO BE <br />DETERMINED BY PLUMBING DESIGNER. SEE DRAWINGS FOR INFO. <br />9., F.E. =WALL MOUNTED FIRE EXTINGUISHER, MOUNT AT 4'-0" <br />A.F.F. MAX. TO TOP OF EXTINGUISHER. FIRE EXTINGUISHER TO BE <br />10# ABC EXTINGUISHER TYPICAL FOR WALL MOUNTED. <br />10. F.E.C. = RECESSED OR SIM. RECESSED FIRE EXTINGUISHER <br />CABINET, SEE LIFE SAFETY/ PLAN SHEETS FOR ADD. <br />NOTES <br />GENERAL RESPONSIBILITY NOTES: <br />1. ALL CONTRACTOR RESPONSIBLE TO REVIEW ALL NOTES THIS <br />SHEET. THESE ARE STANDARD MATERIALS AND METHODS FOR <br />CONSTRUCTION. THERE WILL BE %%UNO EXTRAS%%U <br />EXCEPTED BY ANY CONTRACTOR FOR ANY INFO NOT <br />REVIEWED OR MISSED FROM THIS SHEET OF GENERAL NOTES.. <br />2. NO SUBSTITUTIONS OF MATERIALS OR GENERAL PRACTICES <br />AS CALLED OUT WITHIN THIS DRAWING SET WITHOUT THE <br />WRITTEN APPROVAL FROM THE OWNER -LANDLORD, TENANT, <br />ARCHITECT, OR STRUCTURAL ENGINEER. <br />3. IMPORTANT CONTRACTOR NOTES: ALL CONTRACTORS TO <br />SUBMIT DESIGN BUILD (FIRE PROTECTION) FOR OWNER/ <br />ARCHITECT REVIEW PRIOR TO STARTING OF WORK. (FIRE <br />PROTECTION DRAWINGS SUBMITTED ONLY WHERE APPLICABLE) <br />4. ALL CONTRACTORS INCLUDING ELECTRICAL, DATA, TELEPHONE, <br />SOUND AND OR SECURITY TO COORDINATE W/ HVAC <br />CONTRACTOR AND DESIGNER TO VERIFY IF PLENUM AIR <br />RETURNS ARE USED IN THE BUILDING. IF PLENUMS ARE USED <br />ALL CONTRACTORS MUST USE PLENUM RATED WIRE <br />NO ADDITIONAL COSTS WILL BE PASSED ONTO THE BUILDING <br />OWNER FOR LACK OF CONTRACTOR COORDINATION. <br />5, HVAC DESIGNER AND CONTRACTOR ARE RESPONSIBLE TO <br />COORDINATE W/ GENERAL CONTR./ DRYWALL CONTRACTOR <br />IF PLENUM AIR RETURNS ARE USED IN THE BUILDING. <br />DRYWALL CONTRACTOR MUST RETURN ALL GYP. IN THE <br />AREA OF THE PLENUM TO THE BOTTOM SIDE OF THE <br />STRUCTURE. NO COMBUSTIBLE MATERIAL ALLOWED <br />IN THE PLENUM AREA PER CODE. <br />6. WHERE APPLICABLE BUILDINGS WITH FIRE SUPPRESSION SYSTEMS <br />FIRE PROTECTION CONTRACTOR WHEN BLEEDING <br />SYSTEM MUST USE A HOSE TO CATCH BASIN OR LAWN AREA. <br />ABSOLUTELY NO DISCHARGE TO GRADE PAVING. <br />IF DONE TO GRADE PAVING FIRE PROTECTION CONTR. <br />RESPONSIBLE FOR CLEANING OF ALL RUST AND OR STAINS TO <br />RETURN THE PAVING TO ORIGINAL CONDITION. <br />7. GENERAL CONTRACTOR RESPONSIBLE FOR FINAL GENERAL <br />CLEANING PRIOR TO TURN OVER TO LANDLORD AND OR <br />TENANT. GENERAL CONTRACTOR TO CONTACT LANDLORD <br />AND OR TENANT FOR FINAL INSPECTION. <br />8. GENERAL CONTRACTOR IS TO HAVE WINDOWS CLEANED INSIDE <br />AND OUT BY PROFESSIONAL WINDOW CLEANER. PROPER <br />CLEANING TO BE USED W/ NO RAZOR BLADES USE TO PREVENT <br />GLASS SCRATCHING OR ETCHING. <br />9. ALL CONTRACTOR TO PROTECT ALL FINISH MATERIALS (IE: <br />ROOFING, PAVING, CARPET, MASONRY, ETC.) WHEN APPLYING <br />PAINT E.I.F.S. OR ANY MATERIAL. GENERAL CONTRACTOR <br />RESPONSIBLE FOR ALL SUBS AND SUB CONTRACTORS ARE <br />RESPONSIBLE FOR ALL CLEANUP COSTS TO REPAIR MATERIAL TO <br />ORIGINAL CONDITION. <br />10. ' GENERAL CONTRACTOR RESPONSIBLE FOR CONTACTING LANDLORD, <br />TENANT AND ARCHITECT FOR FINAL WALK THRU, PUNCH LIST AND <br />COMPLIANCE STATEMENT PRIOR TO TENANT OCCUPANCY AND <br />FINAL TURN OVER. <br />O <br />WATER CLOSET <br />H.C. ACCESSIBLE <br />BYLANDLORD <br />o <br />v � <br />O <br />SURFACE MOUNTED HAND DRYER <br />AMERICAN SPECIALTIES, INC. <br />MODEL NUMBER: 0185 <br />SUPPLIED BY G.C. <br />INSTALLED BE G.C. <br />R O o SIT THIS DOOR TO SIGN SHALL HAVE <br />RE <br />gU111 tv„U�Jj G'Ala' MAIN UNLOCKED UPPERCASE RAISED <br />MEN MEN WOMEN UNISEX WHEN BUILDING LETTERINGw/ <br />Kc. WOMEN <br />IS OCCUPIED BACKGOUND OF <br />WALL SIGNAGE (TYP.) CONTRASTING COLOR <br />SIGNAGE AT EXT. - LETTERING HGT: 1" (25 mm.) <br />DOORS w/ DEAD BOLTS <br />�i CORRESPONDING <br />GRADE II BRAILLE <br />HEIGHT OF EN, I 3" P. <br />LETTERING 5/8" <br />MIN. TO 2" MAX <br />�---'� WALL MOUNTED SIGNAGE TO BE <br />LETTERING LOCATED ON THE LATCH SIDE OF <br />RAISED 1/32" DOOR CLEAR OF DOOR -SWING _ <br />MOUNT AT 60" TO CENTERLINE y Q <br />UPPER CASE OF SIGN FROM FLOOR <br />LETTERS FINISH FLOOR LINE <br />NOTE: <br />PROVIDE TACTILE EXIT SIGNAGE AT <br />FRONT & REAR EXIT DOORS @ 60" <br />A.F.F. TO THE CENTER OF THE SIGN <br />TOILET ROOM ACCESSORY SPECIFICATIONS: <br />GENERAL NOTES: - SEE TYP. TOILET ROOM ACCESSORY ELEVATIONS <br />FOR MODEL NUMBERS, FINISH AND COLORS <br />- G.C. TO PROVIDE BLOCKING AS REQUIRED <br />AT ALL ACCESSORY LOCATIONS <br />- G.C. TO VERIFY ROUGH OPENING REQUIREMENTS <br />FOR ALL RECESSED MOUNTED EQUIPMENT <br />MANUFACTURER: BOBRICK WASHROOM EQUIPMENT, INC. <br />PRODUCTS: GRAB BARS, TISSUE DISPENSERS, TOWEL DISPENSERS, <br />MIRRORS, SOAP DISPENSERS, ETC. <br />TOILET ROOM NOTES: <br />- 6 1/2" MAXIMUM SINK DEPTH <br />- INSULATE PIPES BELOW COUNTERTOPS (WATER AND WASTE LINES) <br />W/ PVC MOLDED PROTECTION (BY PLUMBING CONTRACTOR) <br />- MANUAL FLUSH VALVE FOR URINAL MUST NOT EXCEED 44" IN HEIGHT <br />11. <br />ALL SUB CONTRACTORS TO MARK ALL PRIVATE UTILITIES (IE: <br />CONCRETE SLAB NOTES: <br />DATA, SITE LIGHTING, IRRIGATION, ETC) EACH TIME DIGGERS <br />HOTLINE IS CALLED. <br />1. <br />SAWCUT & REMOVE EXISTING CONC. SLAB AS REQUIRED FOR NEW WORK. <br />CONTRACTOR TO REINF. AND PATCH TO MATCH EXISTING, TYPICAL. <br />12. <br />GENERAL CONTRACTOR TO NOTIFY ARCHITECT, ENGINEER, TENANT <br />AND LANDLORD OF ANY CHANGE OR DEVIATION FROM PLAN WITH <br />2. <br />SLAB TO BE PLACED IN A TEMPERED SPACE AND SHALL NOT HAVE ADDITIONAL <br />IN 24 HOURS OF VERIFICATION TO ALLOW AMPLE RESPONSE TIME <br />ADDITIVES IN THE MIXTURE TO AID CURING IN COLD TEMPERATURES OR TO INCREASE <br />IF REVISIONS ARE REQUIRED. <br />CURING TIME BEYOND ACCEPTABLE TIME FRAMES. <br />13. <br />ALL CONTRACTORS TO REVIEW PROPER PROJECT CLOSE-OUT <br />3. <br />COORDINATE SLAB CURE TIMES WITH MOISTURE CONTENT REQUIREMENTS OF FLOOR <br />NOTES ON THE COVER SHEET (CS). GENERAL CONTRACTOR <br />FINISH, FLOOR MATERIALS AND ASSOCIATED ADHESIVES. <br />RESPONSIBLE TO COORDINATE W/ ALL SUB CONTRACTORS. ALL <br />INFORMATION SHALL BE PROVIDED AND REVIEWED BY ARCHITECT <br />4. <br />CONCRETE FLOOR TO BE PREPPED TO ACCEPT DIRECT APPLIED FLOOR FINISH AND <br />AND LANDLORD PRIOR TO FINAL DRAW/ PAY REQUEST APPROVAL. <br />FLOORING MATERIAL. COORDINATE W/ LANDLORD AND TENANT. FLOOR TO BE FREE OF <br />DEFECTS AND HAVE A SMOOTH LEVEL FINISH. TENANT'S CONTRACTOR TO SUPPLY AND <br />14. <br />GENERAL CONTRACTOR RESPONSIBLE TO CONDUCT WEEKLY TO <br />INSTALL FLOOR FINISH AND FLOORING MATERIALS. <br />BI-WEEKLY JOB SITE MEETINGS WITH ALL SUB CONTRACTORS ON <br />SITE INCLUDING BOTH LANDLORDS AND TENANTS CONTRACTORS IF <br />5. <br />ALL CONCRETE (SITE, FLOOR, ETC.) TO HAVE CYLINDER SLUMP TEST PER 30 YDS <br />DIFFERENT. GENERAL CONTRACTOR TO ALSO TAKE WEEKLY <br />MIX FOR OWNER, ARCHITECT AND ENGINEER REVIEW. <br />JOBSITE MEETING MINUTES AND PROGRESS PHOTOS TO BE <br />DISPERSED TO ALL CONTRACTORS, ARCHITECTS, ENGINEERS, <br />6. <br />GENERAL CONTRACTOR/ CONCRETE CONTRACTOR TO CONTACT OWNER -LANDLORD, <br />LANDLORD AND TENANT. <br />ARCHITECT OR ENGINEER ONE DAY PRIOR TO CONCRETE POUR TO REVIEW AGGREGATE <br />BASE. BASED ON SITE LOCATION THIS MAY BE REVIEWED VIA SITE PHOTOS. <br />15. <br />GENERAL CONTRACTOR TO DISPERSE ALL PLANS, ADDENDUMS AND <br />CONSTRUCTION BULLETINS TO ALL BIDDERS AND SUB <br />7. <br />AT NEW SLAB POURS THAT CONNECT TO EXISTING SLABS. CONTRACTOR SHALL DRILL <br />CONTRACTORS. GENERAL CONTRACTOR RESPONSIBLE TO MAINTAIN <br />AND DRIVE 5/8" DIA. SMOOTH ROD @ 18" O.C. MIN. RODS SHALL BE 16" LONG W/ 8" <br />A PLAN HOLDERS LIST/ LOG. GENERAL CONTRACTOR TO HAND <br />EMBED. TIE TO WIRE MESH REINFORCEMENT (TYP.). COAT ONE END OF ROD TO PREVENT <br />OUT FULL SETS OF PLANS TO EACH CONTRACTOR NO PARTIAL <br />BONDING W/ SLAB. <br />PRINTING WILL BE ACCEPTED. <br />8. <br />GENERAL CONTRACTOR TO PROTECT ALL CONCRETE SURFACES FROM OILS AND <br />GENERAL ROOM FINISH NOTES: <br />STAINS. THERE WILL BE NO WRITING ALLOWED ON EXPOSED SLABS. <br />1. <br />ALL GYP. BOARD SURFACES SHALL BE LEVEL 4 GRADE FINISH <br />9• <br />COVER NEWLY PLACED SLAB W/ POLY TO CONTROL MOISTURE CONTENT AND , <br />AND GYP. BD. SURFACES SHALL BE TAPED, MUDDED AND <br />FACILITATE EVEN CURING THROUGHOUT. <br />PRIMED TO ACCEPT TENANT FINISHES. COORDINATE FINAL <br />FINISH MATERIAL AND COLORS WITH FINISH PLAN. SPRAYED <br />10. <br />COORDINATE SLAB SAWCUT JOINTS W/ ORIGINAL BUILDING PLANS. IF PLANS DO NOT <br />ON PAINT AND BACK ROLL FOR TEXTURE. WALL FINISH TO BE <br />NOTE SAWCUT JOINTS, MATCH EXISTING CONCRETE SAWCUT JOINTS. IF NO EXISTING <br />MAINTAINED OVER ENTIRE WALL SURFACE FROM THE FLOOR TO <br />SAWCUT JOINTS, MAINTAIN 15' x 15' SAWCUT JOINT GRID (TYP.) <br />A MIN. OF 6" ABOVE FINISH CEILING HEIGHT. COORDINATE <br />WITH SUPPLIED BASE TYPE/ HT. <br />GENERAL DOOR/HARDWARE NOTES: <br />2. <br />ALL EXPOSED BLOCK WALLS SHALL BE PREPPED, BLOCK <br />FILLER/ PRIMER APPLIED AND FINISHED WITH TWO (2) COATS <br />1. <br />HARDWARE LOCK KEYING - <br />PAINT. <br />HARDWARE SUPPLIER TO PROVIDE LOCK SCHEDULE, KEY DIAGRAM AND HAVE A <br />3. <br />PAINT EXPOSED STRUCTURE, MECHANICAL, AND <br />REPRESENTATIVE GO OVER BUILDING KEYING DIRECT W/ OWNER -LANDLORD AND TENANT. <br />ELECTRICAL EQUIPMENT TO MATCH COLOR OF THE <br />KEYS TO BE HANDED DIRECT TO OWNER/TENNANT. <br />ADJACENT WALLS (EXCEPT FACTORY FINISHED FIXTURES). <br />2. <br />ALL CYLINDERS TO BE SCHLAGE HEAVY DUTY'D' SERIES FULL SIZE W/ <br />4. <br />FLOOR FINISH MATERIALS SHALL BE COORDINATED WITH TENANT <br />INTERCHANGEABLE CORES. NO SUBSTITUTIONS. <br />AND INSTALLED PER PLANS. <br />3. <br />FINAL CORES TO BE COORDINATED W/ OWNER -LANDLORD &TENANT. <br />5. <br />ALL MTL. STUD FRAMED SOFFITS TO HAVE DIAGONAL BRACING AS <br />4. <br />ALL HOLLOW METAL DOORS/FRAMES SHALL BE WELDED - NO KNOCK DOWN FRAMES <br />REQUIRED FOR STABILITY AND GYP. BD. ALL SIDES TO MIN. 6" <br />PERMITTED UNLESS SPECIFICALLY NOTED. <br />ABOVE ADJACENT FINISH CLG. HEIGHT. <br />5. <br />ALL HARDWARE TO BE AMERICANS WITH DISABILITIES ACT (A.D.A.) COMPLIANT <br />6. <br />ALL CEILING GRIDS SHALL BE CENTERED IN EACH ROOM UNLESS <br />OTHERWISE NOTED, SEE REFLECTED CEILING PLAN. <br />6. <br />ALL TOILET ROOM DOORS TO HAVE A CLOSER AND PRIVACY LOCK, SEE HARDWARE <br />SCHEDULE FOR ADDITIONAL NOTES. <br />7. <br />ALL ELECTRICAL AND MECHANICAL FIXTURES TO BE <br />INSTALLED WITHIN CEILING SHALL BE CENTERED ON CEILING <br />TILE UNLESS NOTED OTHERWISE, SEE MEP DRAWINGS. <br />7. <br />PROPER EXIT HARDWARE IS REQUIRED ON ALL EXIT AND EXIT ACCESS DOORS. DEAD <br />BOLT HARDWARE SHALL COMPLY WITH REQUIREMENTS OF THE 2003 INTERNATIONAL <br />BUILDING CODE. <br />8. <br />ANY LOCATION GYP. BD. CONTACTING DISSIMILAR MATERIAL <br />PROVIDE SEALANT JOINT PRIOR TO PAINT/ FINISH MATERIAL, TYP. <br />8. <br />ALL HARDWARE TO BE SCHLAGE OR EQUAL. CYLINDERS TO BE HEAVY DUTY. ALL <br />FINISHES TO BE BID AS 626 SATIN CHROME FINISH, UNLESS NOTED OTHERWISE. <br />9. <br />PROVIDE THE FOLLOWING AT WALL TO FRAME/ GLASS TERMINATION. <br />COORDINATE FINAL HARDWARE COLOR/FINISH W/ OWNER -LANDLORD, ARCHITECT AND <br />ALIGN NEW WALL WITH CENTER OF EXIST. WINDOW MULL TYPICAL, <br />TENANT PRIOR TO ORDERING/INSTALLATION. <br />STEP WALL AT WINDOW SILL/ HEAD. PROVIDE VINYL'J' TRIM <br />CLOSURE TO WINDOW FRAME TYPICAL, PROVIDE CONT. SEALANT <br />JOINT. PROVIDE BREAK MTL. CLOSURE TO MATCH WINDOW FRAME AT <br />g <br />ENTRY DOORS TO HAVE PASSAGE/ENTRY LOCKSET W/ CLOSER, COORDINATE W/ TENANT. <br />FACE OF WALL EXPOSED TO FRONT OF STORE FRONT. <br />10. <br />AT RATED ROOMS HARDWARE SUPPLIER TO PROVIDE PROPER LOCKS, CLOSERS, ECT. TO <br />MEET CODE. <br />10. <br />AT HOLLOW METAL OR ALUMINUM FRAMES (IE: WINDOW/ DOORS) <br />PLACED IN GYP BD WALL ASSEMBLIES. RETURN GYP. BD. TO <br />11. <br />HARDWARE SUPPLIER TO PROVIDE DOOR STOPS AT ALL DOORS. (IE WALL STOP, HINGE <br />FRAME, PROVIDE PLASTIC'J' CHANNEL AND SEALANT TYP. <br />STOP, FLOOR STOP OR OVERHEAD.) THESE STOPS TO BE PROVIDED IN THIS ORDER WITH <br />ENTIRE FRAME. <br />WALL STOPS AS PREFERRED APPLICATION. SEE HARDWARE SCHEDULE FOR NOTES. <br />11. <br />IF GYP. BD. IS STOPPED SHORT OF STRUCTURE ABOVE. <br />INSULATION CONTRACTOR TO PROVIDE STRAPPING AT 24" O/C <br />VERTICAL AND SPRAY INSULATION TO BE USED AT THE CAVITY TO <br />PREVENT INSULATION SLUMPING. <br />13. <br />FLOORING CONTRACTOR TO PROVIDE COLOR MATCHED CAULK TO FLOOR <br />TILE FINISH (IE: CERAMIC, VCT) AT ALL FLOOR DRAINS AND CLEAN OUTS. <br />FINISH NOTES: <br />1. <br />INTERIOR WALL & CEILING FINISHES SHALL COMPLY W/IBC 803.5. <br />803.5 INTERIOR FINISH REQUIREMENTS BASED ON GROUP. INTERIOR WALL <br />AND CEILING FINISH SHALL HAVE A FLAME SPREAD INDEX NOT GREATER <br />THAN THAT SPECIFIED IN TABLE 803.5 FOR THE GROUP AND LOCATION <br />DESIGNATED. INTERIOR WALL AND CEILING FINISH MATERIALS, OTHER THAN <br />TEXTILES, TESTED IN ACCORDANCE WITH NFPA 286 AND MEETING THE <br />ACCEPTANCE CRITERIA OF SECTION 803.2.1, SHALL BE PERMITTED TO BE <br />USED WHERE A CLASS A CLASSIFICATION IN ACCORDANCE WITH ASTM E <br />84 IS REQUIRED. <br />EXIT ENCLOSURES & EXIT PASSAGEWAYS - CLASS B INTERIOR FINISH MATERIALS <br />CORRIDORS, ROOMS & ENCLOSED SPACES - CLASS C INTERIOR FINISH MATERIALS <br />LAVATORY SHALL NOT ENCROACH <br />INTO CLEAR FLOOR SPACE OF <br />WATER CLOSET (TYP.) <br />7'-1 119" <br />1 RESTROOM 1 <br />A5.0 SCALE: 1/4" = V-0" <br />7'-9 1 /9" <br />2 RESTROOM 2 <br />A5.0 SCALE: 1/4" = V-0" <br />16X28.75X24 <br />2D1FD <br />BASE CAB <br />AD-RD-01-AOO <br />fV <br />--f <br />I t <br />10'-2" <br />FINISH GYP. OPENING <br />4 <br />A5.0 <br />RECEPTION DESK PLAN DETAIL <br />SCALE: 3/8" = V-0" <br />1 <br />5 RECEPTION DESK DETAIL <br />A5.0 SCALE: 1/2" = V-0" <br />GENERAL HVAC NOTES: <br />11 2'-0" <br />1. ONE DIGITAL THERMOSTAT WITH RELATED LOW VOLTAGE WIRING PER HVAC TYP. <br />UNIT/ZONE. SEE HVAC DRAWINGS. <br />2. ALL GAS PIPING TO BE RUN FROM METER DIRECT TO INTERIOR NO GAS <br />PIPE TO RUN UP EXTERIOR WALLS. ALL GAS PIPING MUST BE PRIMED AND - _- <br />PAINTED TYPICAL. <br />3. INSULATE ALL NECESSARY DUCTWORK AND PIPING PER CODE. <br />4. SUPPLY AND INSTALL ALL NECESSARY EXHAUST FANS, DUCTWORK, VOLUME MICROWAVE <br />DAMPERS, GRILLES, REGISTERS AND LINEAR DIFFUSERS PER CODE. -t <br />5. PROVIDE AIR BALANCING OF THE ENTIRE SPACE BY PROVIDING FULL B <br />TESTING AND BALANCING REPORT, FOR LANDLORD & TENANT REVIEW. <br />z - <br />6. PROVIDE ALL STATE & LOCAL PERMITS AND ANY OTHER TRADE RELATED FEES. O <br />- <br />7. AT RATED ROOMS CONTRACTOR TO PROVIDE DUCT FIRE DAMPERS AS <br />U iv <br />REQUIRED BY CODE TYPICAL. THIS WOULD ALSO APPLY TO ANY PIPE <br />PENETRATIONS THAT WILL BE REQUIRED TO BE FIRE CAULKED OR SLEEVED TYPICAL. 0 <br />8. SEE LANDLORD NOTES ON SHEET T2.0 FOR ADDITIONAL INFORMATION <br />1'- <br />PLUMBING NOTES: DOORS W/ INTEGRAL - <br />KICK SPACE, TO OPEN <br />1. PROVIDE SEPARATE WATER METER FOR TENANT SPACE, TYPICAL, COORDINATE CLEAR FOR H/C ACCESS <br />W/ BUILDING OWNER/LANDLORD AND PLUMBING DRAWINGS. -INSULATE PIPES <br />2 ALL PLUMBING FIXTURES TO MEET ADA GUIDELINES AND STATE/LOCAL CODES <br />2'-0" <br />ELEVATION - RECEPTION <br />SCALE: 3/8" =1'-0" <br />9 <br />-v <br />L OPEN 7, OPEN <br />FILE FILE 7 <br />FINISH FLOOR LINE <br />MODESTY PANEL MODESTY PANEL <br />6� ELEVATION - BUSINESS OFFICE <br />SCALE: 3/8" = V-0" <br />NOTE: <br />CASEWORK LAYOUT <br />TO BE COORDINATED <br />W/ASPEN DENTAL <br />4 a MILWORK SUPPLIER <br />fV <br />ALL BASE CABS <br />ARE 24" DEEP I I <br />I I <br />OPEN <br />II \ I FOR I <br />\ - I FRIDGE I <br />\ / L---J <br />T-0" I1, 2'-0" <br />AND ORDINANCES. 7 ELEVATION - STAFF LOUNGE <br />3. ALL ROOF DRAIN LEADERS AND OVERFLOW PIPING TO BE WRAPPED IN PIPE A5.0 SCALE: 3/8" = 1'-0" <br />INSULATION ALL AREAS NO EXCEPTIONS. <br />4. PROVIDE ALL STATE & LOCAL PERMITS AND ANY OTHER TRADE RELATED FEES. <br />5. ALL WATER PIPING WILL BE TYPE L COPPER AND WILL CONNECT TO EXISTING, <br />SEE PLUMBING DRAWINGS FOR ADDITIONAL INFO. <br />6. ALL DRAIN PIPING WILL BE PVC PLASTIC AND WILL CONNECT TO EXISTING, <br />SEE PLUMBING DRAWINGS FOR ADDITIONAL INFO. <br />7. AT RATED ROOMS CONTRACTOR TO PROVIDE FIRE CAULKING OR SLEEVE <br />PIPING AS REQUIRED BY CODE TYPICAL. <br />8. SEE LANDLORD NOTES ON SHEET T2.0 FOR ADDITIONAL INFORMATION 9'-0" <br />ELECTRICAL NOTES: <br />4'-6" <br />4'-6- <br />1 PROVIDE SEPARATE METERED, DEDICATED SERVICE AND PANEL PER TENANT <br />6" <br />6" <br />ELECTRICAL DRAWINGS. <br />1/2" GAS LINE REDUCED <br />TO 3/8" FMT ON RT OF <br />3" <br />2. COORDINATE PANEUSUB PANEL LOCATION W/ LANDLORD/TENANT IF <br />1 1/4" <br />TABLE -TERMINATE PER <br />o <br />LOCATED WITHIN TENANT SPACE. <br />DETAIL D-1343/MD <br />3. COORDINATE ALL POWER, PHONE AND DATA REQUIREMENTS W/ TENANT. <br />1 1/2" COPPER AIR 1 1/2" COPPER AIR -� <br />LINE AT 24" AFF LINE AT 24" AFF <br />4. COORDINATE PHONE SERVICE INSTALL REQUIREMENTS W/ TENANT. VERIFY <br />o o <br />PANEL LOCATION W/ TENANT AND TENANT DRAWINGS TYP. <br />®® -TERMINATE PER m® -TERMINATE PER mm <br />®® DETAIL D-13A/MD <br />K DETAIL D-13AIMD m <br />5. ALL WIRING TO BE INSTALLED IN CONDUIT, TYPICAL <br />iv <br />� <br />� <br />6. IN PATIENT ROOMS/AREAS ALL ELECTRICAL REQUIRES REDUNDANT GROUNDING. <br />1/2"iii <br />QUAD OUTLET � � <br />SEE ELECTICAL <br />QUAD OUTLET �q <br />SEE ELECTICAL <br />7. AT RATED ROOMS CONTRACTOR TO PROVIDE FIRE CAULKING OR SLEEVE <br />CLR. PLANS CLR. <br />PLANS <br />PIPING AS REQUIRED BY CODE TYPICAL. <br />FINISH FLOOR LINE <br />8. PROVIDE ALL STATE & LOCAL PERMITS AND ANY OTHER TRADE RELATED FEES. <br />9 W1 PULL WIRE <br />TO PULL DINATE OEE <br />ELEVATION - LAB WORKSTATION <br />SIZUIT <br />FOR E TELEPHONE COO. USE. COORDR OFOCONDU TB TELEPHONE PROVIDER. <br />s <br />A5.0 10. G.C. TO PROVIDE MIN. 1/2" PLYWOOD PANEL. COO_ RDINATE REQUIRED SCALE: 1/2" = 1'-0" <br />LOCATIONS W/ TENANT. <br />11. ELEC. CONTRACTOR RESPONSIBLE FOR COORDINATING TELEPHONE <br />PANEUEQUIPMENT LOCATIONS W/ TELEPHONE CO. <br />12. SEE LANDLORD NOTES ON SHEET T2.0 FOR ADDITIONAL INFORMATION <br />EXCEL <br />ENGINEERINGInc. <br />100 CAMELOT DRIVE <br />FOND DU LAC, WI 54935 <br />PHONE: (920) 926-9e00 <br />FAX: (920) 926Ae01 <br />Always a Better Plan <br />Lf� <br />O <br />� <br />Q <br />I- <br />z <br />W <br />Q <br />O <br />W <br />W <br />CD <br />Q <br />> <br />> <br />Z <br />Q <br />W <br />LLJ <br />W <br />Z <br />U <br />LLj <br />Q <br />V) <br />V) <br />D <br />.. ~ <br />cl:f <br />W <br />U <br />Q <br />LJv <br />Q <br />N <br />Z Lw <br />C (n <br />(n 00 Q <br />O Q N W <br />Q <br />I <br />N <br />W <br />H- <br />W <br />V) <br />f- <br />7-0 <br />O <br />� <br />W <br />U <br />J <br />M <br />m <br />W <br />� <br />� <br />J <br />J <br />� <br />J <br />J <br />cn <br />Q <br />..Q <br />CD <br />z <br />J <br />r- <br />J <br />U W <br />I <br />J <br />W <br />of <br />0 W <br />= <br />_ <br />W <br />W <br />O <br />W <br />(n <br />W <br />I-, <br />LIJ <br />Q <br />N <br />I1- <br />N <br />SHEET <br />ISSUE: <br />NOVEMBER <br />23, <br />2009 <br />SEE TITLE SHEET <br />TO <br />CONFIM <br />THAT THIS SHEET <br />HAS <br />BEEN <br />ISSUED FOR <br />CONSTRUCTION <br />REVISIONS: <br />SEE PLAN <br />r-=-�_ __- - - <br />j KEYBOARD <br />& LCD iv <br />II MONITOR II <br />LL-- ---I-- --� <br />N <br />PRINTER <br />J BOX OR PLASTER <br />RING @ 18" A.F.F. <br />1"o CONDUIT N <br />ABOVE CEILING o 0 m m I I o <br />I I � <br />2"o CONDUIT i CPU N <br />ABOVE CEILING I <br />i I <br />QUAD OUTLET `---J - <br />FINISH FI <br />ELEVATION - ALCOVE <br />SCALE: 1/2" = 1'-0" <br />I � i <br />I I CLEAR FLOOR <br />L__-1 SPACE <br />"30 <br />MIN. <br />17" - 19" <br />3" <br />MAX. EQUIP. ONLY <br />PERMITTED IN <br />SHADED AREA <br />H <br />X U <br />= z z <br />co a 04 <br />cn CV <br />8" 6" <br />MIN. MAX. <br />" CONTROLS MUST BE MOUNTED IN FRONT <br />OR SIDE MOUNTED NEAR FRONT EDGE <br />" PROVIDE CUP DISPENSER FOR <br />NON -WHEELCHAIR USERS. <br />10 E.W.C. DETAIL <br />A5.0 SCALE: 1/4" = 1'-0" <br />