Laserfiche WebLink
i <br />T.T:��1 <br />o <br />'1'a <br />IiIm <br />W � <br />POWER & DATA PLAN - LEVEL 1 <br />1/8" = V-0" <br />42 12 <br />i <br />1 <br />i <br />s ; <br />E <br />� f <br />GENERAL POWER & DATA NOTES <br />1. ARCHITECT TO VERIFY ALL POWER & SIGNAL LOCATIONS PRIOR TO <br />INSTALLATION. <br />��•-_ �l.Tn►�rlx�ur�»y.�m:r�.u:�n..� ��I.r•�:���w�rr.a�l <br />4. VERIFY CORE LOCATIONS WITH ARCHITECT PRIOR TO DRILLING. <br />5. FURNITURE IS SHOWN FOR REFERENCE PURPOSES ONLY, UON. <br />6. SURVEY FIELD CONDITIONS AND VERIFY THAT WORK IS FEASIBLE AS SHOWN. <br />VERIFY LOCATION OF ALL CUTLETS IN RELATION TO STRUCTURAL AND OTHER <br />ELEMENTS AS REQUIRED. NOTIFY ARCHITECT IN WRITING OF ANY <br />DISCREPANCIES BEFORE PROCEEDING WITH WORK <br />7. ARCHITECTURAL DRAWINGS DETERMINE LOCATION AND TYPE (ARCHITECT TO <br />VERIFY W/ ENGINEER) OF ALL OUTLETS AND TAKE PRECEDENCE OVERALL <br />OTHERS, LON. ELECTRICAL ENGINEER'S POWER PLAN SHALL GOVERN THE WIRING <br />LAYOUT AND INSTALLATION IN COMPLIANCE WITH ALL LAWS APPLICABLE AND <br />ENFORCED BY GOVERNING AUTHORITIES. <br />8. OUTLETS SHOWN BACK TO BACK ON PARTITION WALLS SHALL BE OFFSET 24' <br />OC, OR MOUNTED AT DIFFERENT HEIGHTS IF INDICATED. <br />9. COORDINATE ALL WORK RELATED TO EQUIPMENT WITH MANUFACTURERS <br />RECOMMENDATIONS, SPECIFICATIONS AND INSTRUCTIONS. <br />10. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR CONDUIT OR <br />PLUMBING LINES SHALL BE FULLY PACKED & SEALED IN ACCORDANCE WITH THE <br />APPLICABLE BUILDING AND FIRE CODES. <br />11. FURNISH AND INSTALL UNDERWRITERS LABORATORIES, INC- (UL) LABELLED <br />DEVICES THROUGHOUT. <br />12. INSTALL WALL MOUNTED OUTLETS 18 INCHES ABOVE FINISHED FLOOR, UON <br />HEIGHTS SHALL BE DETERMINED FROM FINISHED FLOORTOTHE CENTERLINE OF <br />COVER PLATE, INSTALLED VERTICALLY, GROUNDING POLE AT TOP, LION <br />13. MAINTAIN A4-INCH HORIZONTAL CLEARANCE IN ALL DIRECTIONS, MIN. FROM <br />EDGE OF COVER PLATE, FOR WALL MOUNTED OUTLETS, OR FROM EDGE OF <br />MONUMENT FOR FLOOR MOUNTED OUTLETS, WHEN ADJACENT TO A WALL, <br />COLUMN, OR SIMILAR ELEMENTS, UON. <br />14. INDICATED DIMENSIONS ARE TO THE START OF THE COVER PLATE OR <br />MONUMENT. UON. <br />15. ELECTRICAL, SWITCH AND OUTLET COVER PLATES, SURFACE HARDWARE, <br />ETC. SHALL BE INSTALLED AFTER PAINTING AND/OR APPLICATION OF WALL <br />COVERINGS & CARPET SPECIFIED. <br />16. FURNISH AND INSTALL ALL FIXTURES, ASSOCIATED TRIM AND FIXTURE <br />LAMPS AS REQUIRED. <br />17. ALIGN POWER/ DATA DEVICES, AND WALL MOUNTED LIGHT FIXTURES AT THE <br />CENTERLINE OF THE WALL SECTION THEY ARE MOUNTED ON, LION. <br />18. COORDINATE PC7WER/ DATA DEVICE & LIGHT FIXTURE MOUNTING LOCATIONS <br />WITH INTERIOR ELEVATIONS, FINISHES, & CASEWORK <br />19. PROVIDE EXTENSION RINGS AND MOUNTINGACCESSORIES WHERE REQUIRED <br />FOR POWER/ DATA DEVICES AND LIGHT FIXTURES TO COORDINATE WITH <br />INTERIOR FINISHES AND CASEWORK <br />20. GC TO COORDINATE ALL SWITCHES, STROBES, AND WALL MOUNTED DEVICES <br />WITH SCHEDULEDA/V EQUIPMENT. REFERENCE A901 FOR ADDITIONAL <br />INFORMATION. <br />21. ALL CABLING ROUTING THROUGH NON-HUMANA SPACE TO BE IN CONDUIT LION <br />PROVIDE 4" SLEEVE INTO SERVER AND VENDOR ROOMS FOR CABLE RUNS AS <br />REQUIRED. <br />22. GC TO COORDINATE WITH FURNITURE VENDOR ON MOUNTING HEIGHT OF <br />OUTLETS TO PROVIDE ACCESSIBILITY W1-IEN FURNITURE IS IN PLACE. <br />23. ALL SWITCHES, DEVICES, OUTLETS, AND COVER PLATES TO BE WHITE UON. <br />KEYED NOTES <br />7 <br />COORDINATE POWER REQUIREMENTS & MOUNTING HEIGHTS <br />WITH SCHEDULED EQUIPMENT <br />12 <br />PROVIDE POWER AS REQUIRED FOR ELECTRONIC CARD READER <br />15 <br />PROVIDE POWER AS REQUIRED FOR HANDRYER <br />16 <br />INSTALL GARBAGE DISPOSAL UNDER SINK -WASTE KING LEGEND <br />SERIES 9930 OR EQUAL. PROVIDE POWER AS REQUIRED <br />19 <br />REFERENCE MEP DRAWINGS FOR IT ROOM REQUIREMENTS <br />31 <br />PROVIDE POWER & CABLE IN CEILING FOR CEILING SUSPENDED <br />AV EQUIPMENT. MIN 6'-0" WHIP. <br />32 <br />GC TO PROVIDE MIN 3/4" CONDUIT ABOVE CEILING FOR A/V <br />CONNECTIVITY BETWEEN DMARC & TV LOCATIONS TO RECEIVE <br />CABLE. REFERENCE ELEVATIONS & A/V DETAILS FOR ADDITIONAL <br />INFORMATION. <br />35 <br />REFERENCE ELEVATIONS & A/V DETAILS FOR INFORMATION <br />REGARDING ADDITIONAL POWER AND LOW VOLTAGE <br />REQUIREMENTS. <br />37 <br />INTRUSION KEYPAD. GC TO COORDINATE WITH SECURITY <br />VENDOR FOR FINAL LOCATION & REQUIREMENTS. <br />41 <br />PROVIDE POWER AS REQUIRED FOR CALL FOR ASSISTANCE <br />DEVICE <br />42 <br />PROVIDE POWER FOR SIGNAGE ON DEDICATED CIRCUIT. <br />LOCATION TO BE SPECIFIED AFTER SIGN SURVEY BY OTHERS <br />POWER & DATA LEGEND <br />ILI WALL MOUNTED QUADRUPLEX OUTLET <br />Q� <br />WALL MOUNTED DUPLEX OUTLET <br />D <br />WALL MOUNTED DEDICATED DUPLEX OUTLET <br />(GFI <br />WALL MTD POVVEROUTLEf, "GFI" INDICATES <br />j { <br />GROUND FAULT INTERRUPT, 18" AFF UON <br />FLUSH FLOOR JUNCTION BOX POWER DATA <br />ANDAV WHERE REQUIRED (HARDWIRE) <br />WALL MOUNTED ANALOG OUTLET <br />FLUSH FLOOR FURNITURE FEED - POWER <br />F� DATA JUNCTION BOX, VERIFY REQUIREMENTS <br />WITH FURNITURE <br />JD FLUSH FLOORJUNCTION BOXW/ FACEPLATE - <br />POWER DATA AND AV WHERE REQUIRED (4- <br />POWER, 4 -DATA) <br />WALL MOUNTED COMBO VOICE & DATA <br />WALL MOUNTED TV JACK <br />M <br />WALL MOUNTED AV SYSTEM JUNCTION <br />FF WALL MOUNTED FURNITURE FEED - <br />POWER AND DATA JUNCTION BOX VERIFY <br />REQUIREMENTS WITH FURNITURE <br />WALL MOUNTED JUNCTION BOX- POWER, <br />DATA, AND AV WHERE REQUIRED (4 POWER <br />AND DATA TYPICAL WHEN HARDVURE NOT <br />WALL MOUNTED CARD READER <br />Project <br />HUMANA- ZEPHYRHILLS, <br />FLORIDA - GUIDANCE <br />CENTER <br />7920 GALL BLVD. <br />ZEPHYRHILLS, FLORIDA 33541 <br />Prepared for <br />HUMANA INC. <br />Contract No: 12.01622.00 <br />H K <br />One Tampa City Center, Suite 1800 <br />Tampa, FL 33602 USA <br />t +1 813 229 0300 f +1 813 223 7116 <br />FL Reg: AAC001139 <br />All reproduction & intellectual property rights reserved 0 2012 <br />-In Association with <br />SDM Consulting Engineers <br />MEP Engineer <br />135 Almeria Ave_ <br />Coral Gables, FL 33134 <br />305.4446.2788 <br />Key Plan <br />