JANITOR
<br />L - - - - - - - - - - J
<br />1FLOOR PLAN - LEVEL 1
<br />1 /8" = V-0"
<br />FLOOR PLAN LEGEND GENERAL PARTITION NOTES
<br />(E) ROOM OR ZONE TO REMAIN, NOT INCLUDED IN THIS
<br />SCOPE OF WORK
<br />(E) GYP BD PARTITION TO REMAIN
<br />NEW GYP BD PARTITION AS INDICATED
<br />NEW GLAZED OPENING WITH ALUM OR HM FRAME AS INDICATED
<br />NEW DOOR, DOOR IDENTIFIER ASSEMBLYAS INDICATED ON
<br />SHEET A901
<br />OFRAME TYPE. REFERENCE SHEET A901
<br />- - 1 HR TAPE
<br />KEYED NOTES
<br />7
<br />COORDINATE POWER REQUIREMENTS & MOUNTING HEIGHTS
<br />WITH SCHEDULED EQUIPMENT
<br />9
<br />PROVIDE PEEP HOLE IN DOOR @ 60" AFF.
<br />11
<br />GC TO PROVIDE 4'X8' SHEET OF 3/4" FIRE RETARDANT PLYWOOD
<br />& PAINT TO MATCH WALL, LEAVING FIRE RATING STAMP
<br />EXPOSED AT THIS LOCATION.
<br />19
<br />REFERENCE MEP DRAWINGS FOR IT ROOM REQUIREMENTS
<br />21
<br />PROVIDE WATER LINE AND SHUT OFF VALVE FOR COFFEE
<br />MAKER, ICE MAKER, AND REFRIGERATOR. GC TO COORDINATE
<br />FINAL LOCATION WITH TENANT.
<br />39
<br />PROVIDE BLOCKING IN WALL AS NECESSARY
<br />43
<br />REMOVE EXISTING HARDWARE. PROVIDE NEW EXIT ONLY
<br />HARDWARE. COORDINATE WITH TENANT SECURITY
<br />1. ALL GYP BD PARTITIONS SHALL BE TAPED, SPACKLED, AND SANDED WITH NO
<br />VISIBLE JOINTS. PROVIDE LEVEL FINISH LION. PATCH AND REPAIR SURFACES TO
<br />MATCH ADJACENT OR ADJOI NI NG SURFACES WHERE REQUI RED. ALL SURFACES
<br />SHALL BE ALIGNED.
<br />2. WHERE FURRED PARTITIONS EXCEED MAXIMUM HEIGHT, BRACE TO ADJACENT
<br />STRUCTURE.
<br />3. FIRE SAFE PENETRATIONS AT RATED PARTITIONS PER APPLICABLE UL ASSEMBLY.
<br />4. ALL INTERIOR PARTITION, PENETRATIONS, OTHER OPENINGS IN THE BUILDING
<br />SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED.
<br />5. PROVIDE METAL STUD ANCHOR BRACKETS AT LOCATIONS INCLUDING BUT NOT
<br />LIMITED TO: GRAB BARS, SHELVING, OVERHEAD CABINETS, SIGNAGE, TOILET ROOMS
<br />ACCESSORIES, ETC.
<br />6. ALL DIMENSIONS TO THE EXTERIOR WALL ARE TO THE INSIDE FACE OF EXISTING
<br />SILL OR FINSH SURFACE. ALL PARTITIONS ARE DIMENSIONED FROM FACE OF
<br />PARTITION TYPE AS INDICATED LION. ALL DIMENSIONS MARKED "CLEAR' OR "CLR"
<br />SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES.
<br />7. ALL WOOD TO BE FIRE RETARDANT TREATED IN ACCORDANCE WITH LOCAL CODES.
<br />8. ALL SIGNAGE IS NIC, LION.
<br />9. ALL GYP BD PARTITIONS RECEIVING RUBBER BASE TO BE FINISHED SMOOTH TO
<br />THE SLAB.
<br />10. PATCH AND REPAIR EXISTING SLAB WITH HYDRALIC CEMENT UNDRELAYMENT AS
<br />REQUIRED.
<br />11. PATCH AND REPAIR EXISTING WALLS IN PREPARATION FOR NEW WALL FINISHES.
<br />12. DIMENSIONS NOTED "CLEAR' OR "CLR' MUST BE ACCURATELY MAINTAINED AND
<br />SHALL NOT VARY MORE THAN +/- 1/8' WITHOUT WRITTEN CONSENT FROM THE
<br />ARCHITECT.
<br />13. ALL CASEWORK, TO BE PREMIUM GRADE OR BETTERAS DEFINED BY THE
<br />ARCHITECTURAL WOCO INSTITUTE.
<br />14. PROVIDE ADJACENT PARTITION TYPE ABOVE ALL STOREFRONT SYSTEMS.
<br />15. GC TO PROVIDE SHOP DRAWINGS OF ALL MILLWORK TO ARCHITECT AND HUMANA
<br />PM PRIOR TO MANUFACTURING.
<br />16. PROM DE BRACKET STOPS AT ALL CORNER OR END CABI NETS
<br />17. GC TO INCLUDE COST TO RE -KEY ALL DOORS ACCESSING OR CONTAINED WITH IN
<br />TENANT SPACE.
<br />18. PROVIDE FLOOR STOPS AT ALL DOORS LION.
<br />19. ALL RESTROOM ACCESSORIES TO BE APPROVED BYTENANT AND ORDERED BY
<br />GC.
<br />20. SOUND MASKING VENDOR TO COORDINATE SOUND MASKING WITH TENANT.
<br />CALIBRATION AND BALANCING PRIOR TO OCCUPATION.
<br />21. GC TO INCLUDE INSTALLATION OF DOOR CHIME IN FRONT AND REAR OF BUILDING
<br />COORDINATE WITH TENANT ON FINAL LOCATION.
<br />22. GC TO PROVIDE CORNER GUARDS TO 48" AFF AT ALL OUTSIDE OORNERS UON.
<br />23. ALL WALLS RECEIVING WALTALKER WALLCOVERING TO EB INSTALLED 19'AWAY
<br />FROM DOOR IN THE OPEN POSITION, TO CORNER OPPOSIT DOOR UON. REFERECE
<br />ELEVATIONS FOR ADDITIONAL INFO.
<br />24. PROVIDE COAT HOOKS ON BACK OF ALL OFFICE DOORS. LIBERTY 9'HEAVY DUTY -
<br />SATIN NICKEL.
<br />25. COFFEE BAR FIXTURES
<br />- SINK- MFG: KOHLER, STYLE: K 6584-KA, COLOR IRON TONES/ BLACK
<br />AND TAN, UNDERCOUNTER MOUNT
<br />- FAUCET - MFG: KOHLER, STYLE: K 16112-4A-BV, REVIVAL, BRUSHED
<br />VIBRANT BRONZE W/ TRADITIONAL LEVER
<br />- STRAINER- MFG: KOHLER, STYLE: K 8801-BV, BRUSHED VIBRANT
<br />BRONZE
<br />RESTROOM FIXTURES
<br />-TOILET- MFG: KOHLER, STYLE: PERADA, COLOR: 96 BISCUIT
<br />-SINK- MFG: CORIAN SOLID SURFACE,- STYLE 820 INTEGRAL BOV\A- IN
<br />"BISQUE"
<br />-FAUCET- MFG: KOHLER, STYLE: K 16102-4, REVIVAL, BRUSHED VIBRANT
<br />BRONZE W/ 9'SPREAD TRADITIONAL LEVER
<br />-SOAP DISPENSER- MFG: KOHLER, STYLE: 1894-G13V, BRUSHED VIBRANT
<br />BRONZE
<br />26. REFER TO DEVICE ALIGNMENT DIAGRAMS ON SHEETA901 FOR TYPICAL
<br />LOCATIONS OF SWITCHES, CONTROLS, AND DEVICES.
<br />27. GC TO INCLUDE COST FOR MANUAL BLINDS IN PRICE. VERIFY WITH TENANT &
<br />LANDLORD TO DETERMINE WINDOW BLIND SPECIFICATION. GC TO COORDINATE WITH
<br />LANDLORD REGARDING BUILDING STANDARD EXTERIOR GLAZING AND TINTING.
<br />28. PROVIDE CORNER GUARDS AT ALL OUTSIDE CORNERS UON. 48" AFF.
<br />29. GC TO PROVIDE FIRE DAMPERS AT ALL RATED PARTITIONS LION. COORDINATE
<br />WITH MECHANICAL DRAWINGS.
<br />30. ALL DEMISING WALLS TO EXTEND TO DECK WITH GYP BOARD EXTENDING FULL
<br />HEIGHT OF PARTITION UON.
<br />31. ALL HUMANA IT ROOMS TO BE DEDICATED SPECIFICLY FOR HUMANA IT EQUIPMENT
<br />AND NO OTHER SERVICES INCLUDING CUSTODIAL, MECHANICAL, NICAL, ELECTRICAL,
<br />PLUMBING, AND ORAIR HANDELING EQUIPMENT. IN ADDITION WHERE APPLICABBE NO
<br />OUTSIDE VENDORS OR EQUIPMENT SHALL SHARE MDF, IDF, OR RISER ROOMS
<br />WITHOUT THE APPROVAL OF HUMANA NETWORK SERVICES & ARCHITECT.
<br />32. NO WATER SUPPLY, DRAINAGE, OR EQUIPMENT PRODUCING WATER TO BE IN,
<br />ABOVE, OR AROUND IT & COMMUNICATION ROOMS UNLESS APPROVED BY HUMANA
<br />NETWORK SERVICES & ARCHITECT. GC TO NOTIFY PROJECT MANAGER & ARCHITECT
<br />OF ANY DISCREPANCIES PRIOR TO EXECUTION OF DOCUMENTED WORK.
<br />33. ALL EXIT DOORS WITH CARD READERS TO BE TIED TO BUILDING SECURITY AND
<br />LIFE SAFTEY SYSTEMS & PROVIDE FAIL SAFE FUNCTIONALITY.
<br />34. INSULATION ABOVE CEILING TO COMPLY W/ IECC2009 REQUIREMENT FOR CLIMATE
<br />ZONE 4A R 38 VALUE. APPLY DEMI LEC "HFAT LOK SOY 200" SPRAY FOAM I NSULATICN
<br />TO MEET R 38 VALUE. PROVIDE PRIMER AND THERMAL BARRIER DEMILEC "BLAZELOK
<br />TB 200" TO OOMPLY WITH I BC 2009 SECTION 2603.4 AND 2603.4.1.6
<br />Project
<br />HUMANA- ZEPHYRH I LLS,
<br />FLORIDA - GUIDANCE
<br />CENTER
<br />7920 GALL BLVD.
<br />ZEPHYRHILLS, FLORIDA 33541
<br />Prepared for
<br />HUMANA INC.
<br />Contract No: 12.01622.00
<br />K
<br />One Tampa City Center, Suite 1800
<br />Tampa, FL 33602 USA
<br />t +1 813 229 0300 f +1 813 223 7116
<br />FL Reg: AAC001139
<br />All reproduction & intellectual property rights reserved © 2012
<br />-In Association with
<br />-
<br />✓,
<br />Y
<br />* r '21
<br />Key Plan
<br />3
<br />Professional Seals
<br />Jonathan Rae License # AR0094342
<br />No. Issue Description YYYY-MM-DD
<br />01 50% CONSTRUCTION DOCUMENTS 06.15.2012
<br />02 BID SET 06.29.2012
<br />03 ISSUE FOR PERMIT 07.27.2012
<br />No. Revision Description YYYY-MM-DD
<br />Drawn by HOK Reviewed by HOK
<br />Project No 12.01622.00
<br />Sheet Title:
<br />LEVEL 1 FLOOR PLAN
<br />Original drawing is 36 x 24 Do not scale contents of this drawing
<br />Sheet Number
<br />
|