MECHANICAL SYMBOLS (GENERAL) <br />XX- I EQUIPMENT TAGS (XX = MARKS BELOW) <br />AHU <br />= AIR HANDLING UNIT <br />SF = <br />SUPPLY FAN <br />AS <br />= AIR SEPARATOR <br />FH = <br />FUMEHOOD <br />CC <br />= COOLING COIL <br />CWP <br />= CONDENSER WATER PUMP <br />CH <br />= CHILLER <br />CHWP= <br />CHILLED WATER PUMP <br />CT <br />= COOLING TOWER <br />FS = <br />FLOW STATION <br />DC <br />= IN -DUCT COIL <br />W-3-1=VARIABLE <br />AIR VOLUME BOX <br />EF <br />= EXHAUST FAN <br />CV = <br />CONSTANT AIR VOLUME BOX <br />P <br />= PUMP <br />FPW <br />= FAN POWERED AIR BOX <br />FCU <br />= FAN COIL UNIT <br />CS = <br />CHEMICAL SHOT FEEDER <br />EF <br />= EXHAUST FAN <br />ACCU= <br />AIR COOLED COND, UNIT <br />RTU <br />= ROOF TOP UNIT <br />ACCH= <br />AIR COOLED CHILLER <br />ET <br />= EXPANSION TANK <br />SCHW= <br />SECONDARY CHILLED WATER <br />SV = <br />LAB, SUPPLY AIR VALVEPCHW= <br />PRIMARY CHILLED WATER <br />EV = <br />LAB. EXHAUST AIR VALVE <br />FEV <br />= LAB. HOOD EXHAUST <br />VALVE <br />1. NEW TO EXISTING CONNECTION <br />`. ram, <br />HVAC DESIGN REQUIRES: <br />YES <br />NO <br />DUCT SMOKE DETECTOR <br />X <br />FIRE DAMPER(S) <br />X <br />SMOKE DAMPER(S) <br />X <br />FIRE RATED ENCLOSURE <br />X <br />FIRE RATED ROOF/FLOOR <br />CEILING ASSEMBLY <br />X <br />FIRE STOPPING <br />X <br />SMOKE CONTROL <br />X <br />MECHANICAL ABBREVIATIONS <br />A/C <br />AIR CONDITIONING <br />AFF <br />ABOVE FINISHED FLOOR <br />AFM <br />AIRFLOW MONITORING STATION <br />AP <br />ACCESS PANEL <br />ATM. <br />ATMOSPHERE <br />BHP <br />BRAKE HORSE POWER <br />BTU <br />BRITISH THERMAL UNIT <br />CD <br />CONDENSATE DRAINAGE <br />CFM <br />CUBIC FEET PER MINUTE <br />DB <br />DRY BULB OR DECIBELS <br />DDC <br />DIRECT DIGITAL CONTROL <br />DH <br />DUCT HEATER <br />DN, <br />DOWN <br />EAT <br />ENTERING AIR TEMPERATURE <br />EDB <br />ENTERING DRY BULB TEMPERATURE <br />E/A <br />EXHAUST AIR <br />ESP <br />EXTERNAL STATIC PRESSURE <br />EWB <br />ENTERING WET BULB TEMPERATURE <br />EWT <br />ENTERING WATER TEMPERATURE <br />EXT <br />EXISTING <br />FLA <br />FULL LOAD AMPS <br />FPM <br />FEET PER MINUTE <br />FPS <br />FEET PER SECOND <br />GALV <br />GALVANIZED <br />GPM <br />GALLONS PER MINUTE <br />HB <br />HOSE BIBB <br />HP <br />HORSE POWER <br />HZ <br />HERTZ <br />IN. W.G, <br />INCHES OF WATER GAUGE <br />LAT <br />LEAVING AIR TEMPERATURE <br />LDB <br />LEAVING DRY BULB TEMPERATURE <br />LWB <br />LEAVING WET BULB TEMPERATURE <br />LWT <br />LEAVING WATER TEMPERATURE <br />MD <br />MOTORIZED DAMPER <br />NC <br />NORMALLY CLOSED <br />NK, <br />NECK <br />NO <br />NORMALLY OPEN <br />NTS <br />NOT TO SCALE <br />OBD <br />OPPOSED BLADE DAMPER <br />ODP <br />OPEN DRIP PROOF <br />OICS <br />OPENING IN CEILING SPACE <br />O/A <br />OUTDOOR AIR <br />PH. <br />PHASE <br />PSI <br />POUNDS PER SQUARE INCH <br />PSIG <br />POUNDS PER SQUARE INCH (GAUGE PRESSURE) <br />R/A <br />RETURN AIR <br />RBJ <br />RUN BETWEEN JOIST <br />S/A <br />SUPPLY AIR <br />SP <br />STATIC PRESSURE <br />T/A <br />TRANSFER AIR <br />TEMP. <br />TEMPERATURE <br />TEFC <br />TOTALLY ENCLOSED FAN COOLED <br />TSP <br />TOTAL STATIC PRESSURE <br />TYP, <br />TYPICAL <br />UG <br />UNDERGROUND <br />U.O.N. <br />UNLESS OTHERWISE NOTED <br />VD <br />VOLUME DAMPER <br />(NOT ALL ABBREVIATIONS ARE USED IN THIS PROJECT) <br />MECHANICAL SYMBOLS (HVAC) <br />71 <br />SUPPLY AIR DIFFUSER (SEE AIR DEVICE SCHEDULE) <br />BLOCKED QUADRANT GRILLE DENOTES BLOW PATTERN. <br />NO BLOCKED QUADRANTS INDICATE 4-WAY BLOW. <br />ElRETURN/EXHAUST <br />AIR GRILLE (SEE AIR DEVICE SCHEDULE) <br />O <br />4-100 <br />AIR DEVICE DESIGNATION (SEE SCHEDULE) <br />SIDEWALL DIFFUSER/GRILLE <br />— <br />SINGLE LINE DUCTWORK <br />�— <br />CONCENTRIC REDUCER (DUCTWORK) <br />BRANCH DUCT WITH 45° TAP <br />CAP (DUCTWORK OR PIPING) <br />E <br />DROP OR RISE IN DUCTWORK (RECTANGULAR) <br />E <br />90° ELBOW (SUPPLY WITH TURNING VANES) <br />pL <br />DOOR LOUVER <br />UC <br />DOOR UNDER CUT <br />H� <br />HUMIDISTAT <br />Tx-y <br />DIGITAL THERMOSTAT IN RECESSED PERFORATED STAINLESS <br />TAMPER -PROOF BOX. <br />(x-x) => NUMBER MATCHING VAV BOX <br />OT <br />WALL MOUNTED DIGITAL THERMOSTAT <br />S� <br />DUCT SMOKE DETECTOR <br />0 EFD <br />EXISTING FIRE DAMPER <br />—� FSD <br />EXISTING FIRE/SMOKE DAMPER <br />NEW FIRE DAMPER <br />—� <br />NEW FIRE/SMOKE DAMPER <br />CO2 <br />CO2 SENSOR <br />24X12 <br />DUCT SIZE DESIGNATION. SIDE SHOWN IS FIRST DIMENSION. <br />SIZE SHOWN IS INTERNAL CLEAR OPENING. SHEET METAL <br />SIZE MUST BE INCREASED FOR INTERNAL INSULATION <br />WHERE SPECIFIED. (0= ROUND DUCT, -ED- = FLAT OVAL DUCT) <br />TURNING VANES (NUMBER OF VANES SHALL BE BASED <br />ON ACTUAL DUCT SIZE, NOT ON SCHEMATIC <br />SYMBOL ON DRAWING). PROVIDE AT EVERY 90° TURN <br />RETURN, EXHAUST OR OUTSIDE AIR DUCT <br />DISCHARGE OR SUPPLY DUCT <br />FLEXIBLE DUCT <br />VOLUME DAMPER (MANUAL) <br />AP ❑ <br />ACCESS PANEL (AP) <br />ACCESS DOOR (AD) <br />AD <br />MOTORIZED DAMPER (120VAC.) <br />M <br />B <br />BACKDRAFT DAMPER <br />BA <br />BAROMETRIC DAMPER (SET TO OPEN AT 8 INWG) <br />D <br />DROP IN DIRECTION OF ARROW <br />R <br />RISE IN DIRECTION OF ARROW <br />O O <br />SPACE RELATIVE PRESSURE RELATIONSHIP. LACK OF <br />SYMBOL INDICATES NEUTRAL PRESSURE. <br />RETURN AIR TRANSFER DUCT <br />Vx-y <br />VARIABLE AIR VOLUME BOX <br />(x) => AIR HANDLING UNIT SERVING VAV BOX <br />(y) => VAV BOX SEQUENTIAL NUMBER WITHIN SAME AHU <br />CE <br />CEILING MOUNTED EXHAUST FAN <br />W/6" O DUCT UP THROUGH ROOF <br />TERMINATE W/WEATHER CAP <br />36" <br />ELECTRICAL CLEARANCE IN FRONT OF EQUIPMENT. NO <br />OBSTRUCTION WITHIN THIS AREA. <br />1" FIBERGLASS FREE SHEETMETAL DUCT LINING TYPICAL OF <br />"ARMACEL" MODEL No. AP/ARMAFLEX SA DUCT LINER. DUE <br />TO THE FACT THAT LINING R-VALUE DOES NOT REACH THE <br />MINIMUM VALUES MANDATED BY CHAPTER 13 OF THE FBC- <br />MECHANICAL, CONTRACTOR IS TO INSTALL EXTERNAL INSULATION <br />AS AND WHERE REQUIRED BY THE PROJECT SPECIFICATIONS. <br />OR <br />®� <br />MECHANICAL GENERAL NOTES: <br />1. ALL SHEET METAL DUCTWORK (MED. AND LOW PRESSURE): THE FABRICATION <br />AND INSTALLATION OF ALL DUCTWORK, TOGETHER WITH RELATED <br />EQUIPMENT, SHALL COMPLY WITH "SMACNA" DUCT CONSTRUCTION STANDARDS, <br />NFPA 90A & 90B, LATEST ADDITION OF ASHRAE GUIDE & DATA BOOK, AS <br />DETAILED ON THE DRAWINGS & PER LOCAL CODES. <br />2. DUCTWORK CONTRACTOR SHALL INSTALL ALL DUCTWORK TO ADHERE TO THE <br />ARCHITECTURAL CEILING HEIGHTS. DUCTWORK CONTRACTOR SHALL INSTALL <br />ALL VAV EQUIPMENT, SUCH AS FAN TERMINAL UNITS, INSTALLED ABOVE THE <br />CEILING AS LOW AS POSSIBLE (MAX. OF 36" ABOVE CEILING LEVEL), E.G. NOT OVER TALL SPACES SUCH AS <br />ENTRANCE LOBBIES, FOR EASE OF MAINTENACE. AVOID INSTALLING THIS <br />EQUIPMENT IN OR CLOSE TO CRITICAL NOISE AREAS SUCH AS CONFERENCE <br />ROOMS. EQUIPMENT SHOULD BE ACCESSIBLE FOR MAINTENANCE WITH A <br />MINIMUM OF 36" ON ALL SIDES. <br />3. ALL EXISTING UTILITY SYSTEMS (I.E., PLUMBING, GAS, FIRE PROTECTION, COMPRESSED AIR, AND <br />CHILLED WATER SYSTEMS) IN THE EXISTING BUILDING MUST BE KEPT IN OPERATION <br />DURING THE PROGRESS OF THE WORK. TEMPORARY CONNECTION SHALL BE <br />PROVIDED TO SYSTEMS, EQUIPMENT, ETC. WHERE NECESSARY TO MAINTAIN CONTINUOUS <br />SERVICE UNTIL THE SYSTEMS AND EQUIPMENT ARE READY FOR OPERATION. <br />4. THE DUCTWORK CONTRACTOR SHALL VERIFY & FIELD MEASURE PRIOR TO FABRICATION OF <br />DUCTWORK. ANY CONFLICT FOUND SHALL BE BROUGHT UP TO THE A/E OF RECORD <br />PRIOR TO ORDERING OR FABRICATING OF THE DUCTWORK. <br />5. PENETRATION OF DUCTWORK BY PIPES, CONDUITS, ELECTRICAL FIXTURES, OR STRUCTURAL <br />MEMBERS IS NOT ACCEPTABLE. <br />6. THE GENERAL CONTRACTOR SHALL PROVIDE ALL ROUGH OPENINGS THROUGH STRUCTURAL <br />WALLS, FLOORS, AND/OR ROOF REQUIRED FOR THE DUCTWORK SYSTEM. <br />7. EXACT LOCATIONS OF THERMOSTATS SHALL BE COORDINATED WITH OTHER DISCIPLINES TRADES, ROOM <br />FURNITURE & A/E BEFORE INSTALLATION. <br />8. CONTRACTOR SHALL COORDINATE LOCATIONS AND SIZES OF ALL PENETRATIONS THROUGH WALLS WITH <br />OTHER TRADES INVOLVED. <br />9. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. <br />10. CEILING DIFFUSERS AND GRILLES TO BE COORDINATED WITH ARCHITECTURAL CEILING LAYOUT PLANS. <br />11. THE DUCTWORK CONTRACTOR SHALL COORDINATE HIS WORK WITH BOTH THE ELECTRICAL AND CEILING <br />CONTRACTOR THROUGHOUT THE ENTIRE PROJECT. <br />12. ROUGH OPENINGS IN FLOOR AND WALLS INDICATED ON THESE DRAWINGS ARE APPROXIMATE. <br />CONTRACTOR MUST CHECK SHOP DRAWING FOR ACTUAL SIZES. <br />13. ALL MATERIALS AND EQUIPMENT SHALL BE PROPERLY AND EFFECTIVELY PROTECTED BY THE CONTRACTOR <br />DURING THE EXECUTION OF THE WORK. <br />14. OUTLETS AND EQUIPMENT LOCATIONS ARE DIAGRAMMATIC, FINAL LOCATIONS WILL BE DETERMINED BY <br />FIELD CONDITIONS AND/OR AS DIRECTED BY THE A/E. <br />15. ALL INSTALLATION WORK SHALL COMPLY WITH THE FLORIDA BUILDING CODE <br />(FBC), THE STANDARDS OF THE AMERICAN SOCIETY OF HEATING, <br />REFRIGERATING, AND AIR CONDITIONING ENGINEERS (ASHRAE), THE NATIONAL <br />FIRE PROTECTION ASSOCIATION (NFPA), AND SREF. THE CONTRACTORS <br />MUST FAMILIARIZE THEMSELVES WITH THE ABOVE REFERENCED <br />CODES/GUIDELINES BEFORE BIDS. THE ACT OF BIDDING THIS PROJECT <br />CONSTITUTES THE UNDERSTANDING OF ALL INFORMATION DEPICTED IN THE <br />CONTRACT DOCUMENTS (INCLUDING BUT NOT LIMITED TO PROJECT <br />SPECIFICATIONS AND PROJECT DRAWINGS). <br />16, DRAWINGS FROM VARIOUS DISCIPLINES ARE INTERRELATED. WHAT <br />IS REQUIRED IN ONE SHALL BE AS BINDING AS IF REQUIRED BY <br />ALL. COMPLEMENTARY COMPONENTS BETWEEN DISCIPLINES, <br />REASONABLE INFERRED AS BEING NECESSARY TO PRODUCE INTENDED <br />RESULTS OR COMPLIANCE WITH THE CODES/STANDARDS LISTED ON NOTE No. 22 ABOVE, <br />SHALL BE DEEMED PART OF THE CONTRACTOR'S EXPECTED PERFORMANCE <br />17. FLEXIBLE DUCTS ARE LIMITED TO 8'-0" LENGTH. WHERE DUCT LENGTH <br />FROM BRANCH TAP TO OUTLET EXCEEDS 8'-0" THE DIFFERENCE IN <br />LENGTH SHALL BE PROVIDED WITH A RIGID DUCT RECTANGULAR OR <br />SPIRAL ROUND OF AN EQUIVALENT CROSS SECTIONAL AREA. <br />REFER TO SPECIFICATION SECTION 15890 FOR FURTHER REQUIREMENTS. <br />H M A. NIA <br />................. .... -- -- ---- -- ---------------- .............. ...................... <br />Project <br />HUMANA- ZEPHYRHILLS, <br />FLORIDA - GUIDANCE <br />CENTER <br />7920 GALL BLVD. <br />ZEPHYRHILLS, FLORIDA 33541 <br />Prepared for <br />HUMANA INC. <br />Contract No: 12.01622.00 <br />HOK <br />One Tampa City Center, Suite 1800 <br />Tampa, FL 33602 USA <br />t +1 813 229 0300 f +1 813 223 7116 <br />FL Reg: AAC001139 <br />All reproduction & intellectual property rights reserved © 2012 <br />In Association with <br />era <br />.........__.._..................._......_...._................__.....--- - -- -- <br />SDM Consulting Engineers <br />MEP Engineer <br />135 Almeria Ave. <br />Coral Gables, FL 33134 <br />305.446.2788 <br />www.sdmcorp.com <br />Key Plan <br />Professional Seals <br />18. ALL MECHANICAL OUTLETS WILL BE LOCATED IN CENTER OF <br />CEILING TILE AS PER ARCHITECTURAL CEILING PLANS UNLESS <br />OTHERWISE APPROVED BY THE ARCHITECT. <br />19. DRAWINGS ARE DIAGRAMMATIC AND SHOW LOCATION INTENT. <br />CONTRACTOR IS TO COORDINATE SYSTEM LAYOUTS WITH OTHER <br />DISCIPLINES TO AVOID CONFLICTS AND FACILITATE <br />ACCESSIBILITY FOR SERVICING <br />ERNESTO ALOMA JOSE I. MARTINEZ <br />20. DRAWINGS INDICATE APPROXIMATE LOCATION OF CEILING P.E. 53823 P.E. 53779 <br />MOUNTED DEVICES. EXACT LOCATION IS TO BE COORDINATED No. Issue Description YYYY-MM-DD <br />WITH ARCHITECTURAL REFLECTED CEILING PLANS. 01 50% CONSTRUCTION DOCUMENTS 06.15.2012 <br />02 BID SET 06.29.2012 <br />21. DESIGN INTENT CONSTITUTES THE PROVISION OF COMPLETE 03 ISSUE FOR PERMIT 07.27.2012 <br />SYSTEMS AS INDICATED WITH ALL NECESSARY COMPONENTS AND <br />ACCESSORIES WHETHER EXPLICITLY SPECIFIED OR IMPLIED TO <br />ACHIEVE FULL OPERATIONAL STATUS. <br />22. CONTRACTOR SHALL MAINTAIN DETAILED AS —BUILT DRAWINGS (UPDATED DAILY) OF <br />WORK PERFORMED ON SITE. AT THE TIME OF SUBSTANTIAL COMPLETION THE <br />CONTRACTOR SHALL PROVIDE THE A/E TEAM A COMPLETE SET OF AS —BUILT <br />DRAWINGS IN AutoCAD RELEASE 2005 FORMAT. THESE AS —BUILT DRAWINGS SHALL HAVE <br />IMPLEMENTED ALL CHANGES TO SYSTEM LAYOUT DURING CONSTRUCTION. No. Revision Description YYYY-MM-DD <br />23. MECHANICAL CONTRACTOR SHALL PREPARE SHOP DRAWINGS IN CADD 1 ADDENDUM 1 2012-07- <br />2 ADDENDUM 2 2012-07-19 <br />9 <br />FORMAT COMPATIBLE WITH 'AUTOCAD' RELEASE 2005 AND SUBMIT HARD COPIES FOR <br />REVIEW PER CONTRACT SPECIFICATIONS. SHOP DRAWINGS SHALL INCLUDE, BUT <br />IT WILL NOT BE LIMITED TO 1 /4" ENLARGED MECHANICAL ROOM SHOP DRAWINGS <br />SHOWING COORDINATION WITH ALL TRADES, DUCTWORK INSTALLATION HEIGHT, <br />AND ALL SUBMITTALS REQUIRED BY THE CONTRACT SPECIFICATIONS. <br />PRIOR TO SUBSTANTIAL COMPLETION WALK THROUGH, CONTRACTOR SHALL PROVIDE CADD AS—BUILTS TO A/E TEAM <br />REFLECTING ACTUAL INSTALLATION. <br />24. CONTRACTOR MUST VISIT THE SITE TO VERIFY EXISTING CONDITIONS AND STUDY <br />"AS BUILT" CONDITIONS PRIOR TO BID. CONTRACTOR SHALL INCLUDE IN THEIR BID <br />PRICE THE COST (INCLUDING MATERIAL, LABOR, OVERHEAD, AND PROFIT) OF ALL REQUIRED Drawn by SDM Reviewed by SDM <br />ITEMS TO SUCCESSFULY INSTALL ALL ITEMS DESCRIBED OR IMPLIED/REQUIRED TO BE INSTALLED <br />(REFER TO NOTE No. 21, 22, AND No. 27) IN THESE CONTRACT DOCUMENTS. Project No 12.01622.00 <br />25. FIRE SAFE AROUND ALL PENETRATIONS THROUGH RATED WALLS. Sheet Title: <br />26. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND EXECUTION MECHANICAL LEGEND, <br />OF ALL NECESSARY <br />CHANGES ATTRIBUTABLE TO INSTALLATION OF SUBSTITUTE <br />EQUIPMENT AT NOADDITIONAL ONAL COST TO OWNER, ABBREVIATIONS, AND <br />27, MECHANICAL CONTRACTOR IS RESPONSIBLE FOR THE MECHANICAL EQUIPMENT START UP GENERAL NOTES <br />TEST AND BALANCE. OWNER WILL PERFORM THE BUILDING'S OFFICIAL TEST AND BALANCE. <br />AS A RESULT OF THE OWNER'S CONTRACTED TEST AND BALANCE AGENCY'S COMMENTS, THE Original drawing is36x24 Do not scale contents of this drawing <br />MECHANICAL CONTRACTOR IS REQUIRED TO PERFORM ALL OF THE APPLICABLE REPAIRS AS <br />A RESULT OF THE SAME AGENCY'S RESULTS. THE COLLEGE T&B COMPANY MUST Sheet Number <br />COORDINATE WITH THE CONTRACTORS AT THE BEGINNING OF THE PROJECT TO SCHEDULE <br />INSPECTIONS AND TESTING PORTS NEEDED FOR THE TEST AND BALANCE. M001 <br />