Laserfiche WebLink
3/4" P & T <br />RELIEF VALVE <br />ADJUSTABLE WATE'. <br />HEATER SHELF BY <br />MOUNT HEATER AS <br />HIGH AS POSSIBLE <br />3/4" CW <br />1/2" HW <br />=AT TRAP (TYP.) <br />kLL VALVE (TYP.) <br />IION <br />ECTRIC WATER HEATER <br />i/4" AIR GAP <br />/4" RELIEF DRAIN LINE <br />RMINATE ® DRAIN PAN <br />'4" ANCHOR SCREWS <br />STALLED USING MFGR. <br />4TCHED TOLERANCE <br />LOT DRILL (TYP.) <br />WALL MOUNTED ELECTRIC WATER HEATER <br />NO SCALE <br />POSITION PIPE TO <br />AVOID OBSTRUCTIONS <br />TO CLEAN -OUTS. <br />STAINLESS STEEL COVER <br />SCREWED TO THREADED <br />C.O. PIPE <br />FACE OF WALL <br />WALL CLEANOUT DETAIL <br />NO SCALE <br />TURN LEAD FLASHING DOWN INTO <br />STACK 2" MIN. <br />z <br />[__4 LB. SHEET LEAD FLASHING <br />FILL IN W/ ROOF MATERIAL <br />12 MIN. <br />i���—ROOFING <br />ROOFING CONSTRUCTION <br />SLEEVE ROOF CONSTRUCTION AS REQ'D. <br />VENT STACK <br />NOTE: <br />ANY VENT PIPE WITHIN 10' OF ANY DOOR , WINDOW , OR EXHAUST OPENING OR <br />OUTSIDE AIR INTAKE SHALL EXTEND NOT LESS THAN 3' ABOVE SAME . <br />VENT-THRU-ROOF DETAIL <br />NO SCALE <br />FIXTURE CONNECTION SCHEDULE <br />COLD <br />HOT <br />MARK <br />DESCRIPTION <br />WASTE <br />VENT <br />WATER <br />WATER <br />REMARKS <br />WC (-H) <br />WATER CLOSET (HANDICAPPED) <br />3" <br />2" <br />2" <br />"KOHLER" MODEL NO. K3999-TR-96, ADA COMPLIANT, COLOR: 96 BISCUIT. <br />"CORIAN" SOLID SURFACE MODEL NO. 820 INTEGRAL BOWN, COLOR: BISQUE. <br />LV (-H) <br />LAVATORY (HANDICAPPED) <br />1 Z" <br />1 z" <br />2" <br />2" <br />"KOHLER" REVIVAL FAUCET MODEL NO. K-16102-4, BRUSHED VIBRANT BRONZE W/ <br />8" SPREAD TRADITIONAL LEVER. <br />"ELKAY" GECR2521 L/R SINGLE BOWL ADA COMPLIANT SINK W/ "KOHLER" <br />SK-1 <br />SINK <br />1 z" <br />14" <br />2" <br />2" <br />VINNATA FAUCET MODEL NO. K-690-VS W/ TRADITIONAL LEVER. "KOHLER" <br />STRAINER MODEL NO. K-8801-BV. <br />"ELKAY" GECR2521 L/R SINGLE BOWL ADA COMPLIANT SINK W/ "KOHLER" <br />SK-2 <br />SINK <br />1'z" <br />14" <br />2" <br />Z" <br />VINNATA FAUCET MODEL NO. K-690-VS W/ TRADITIONAL LEVER. "KOHLER" <br />STRAINER MODEL NO. K-8801-BV. <br />S.S. <br />SERVICE SINK <br />SO <br />2" <br />4° <br />�� <br />"FLORESTONE" MODEL 5 TERRAllO MOP RECEPTOR W/ "AMERICAN STANDARD" <br />8354.112 EXPOSED YOKE WALL -MOUNT UTILITY FAUCET. <br />EWC <br />ELECTRIC WATER COOLER <br />14" <br />14" <br />2" <br />"ELKAY" EZS8L BARRIER -FREE WALL MOUNT WATER COOLER. <br />FD <br />FLOOR DRAIN <br />3" <br />2" <br />* <br />"JOSAM" 3000-S SERIES, CAST IRON, BOTTOM OUTLET, ADJUSTABLE SUPER-FLO <br />STRAINER. TRAP RESEALED FROM NEAREST FIXTURE. <br />NOTES: <br />1. ALL PLUMBING FIXTURES SHALL COMPLY WITH MAXIMUM FLOW RATES AND CONSUMPTION AS PER FBC TABLE 604.4 OF 2007 (PLUMBING). <br />2. COORDINATE FIXTURES COLOR AND FINISH W/ ARCHITECT. <br />WATER HEATER DATA <br />STORAGE IN <br />MANUFACTURER <br />ELECTRICAL <br />MARK <br />INPUT <br />REMARKS <br />LOCATION <br />U.S. GAL. <br />MODEL No. <br />DATA <br />A.O. SMITH <br />EWH <br />30 <br />4.5 KW <br />DEL-30 <br />3060Hz/ 208V <br />/ <br />SEE PLANS <br />CH TE <br />IWH <br />-- <br />4.16 KW <br />SR-20L <br />R-20L <br />/ 3� 60Hz/ 208V <br />SEE PLANS <br />SHOCK ABSORBER SCHEDULE <br />ABSOR11ON TYPE No. <br />75001 <br />75001-S <br />75002 <br />75002-S <br />75003 <br />75003-S <br />75004 <br />75004-S <br />75005 <br />75005-S <br />75006 <br />75006-S <br />P.D.I. SYMBOLS (*) <br />A <br />B <br />C <br />D <br />E <br />F <br />FIXTURE -UNIT RATING <br />1-11 <br />12-32 <br />33-60 <br />61-113 <br />114-154 <br />155-330 <br />(x) CLASSFICATIONS ESTABLISHED BY THE PLUMBING AND DRAINAGE INSTITUTE "STANDARD P.D.I. - WH2O1" <br />NOTES: <br />1. CONTRACTOR TO INSTALL SHOCK ABSORBER AS PER MANUFACTURER INSTRUCTIONS. <br />2. SHOCK ABSORBERS TO BE JOSAM (ABSORBOTRON) OR EQUAL. <br />3. CONTRACTOR TO INSTALL SHOCK ABSORBERS WHERE QUICK CLOSING VALVES ARE PRESENT. <br />4. CONTRACTOR TO PROVIDE ACCESS DOORS WHERE REQUIRED TO SERVICE SHOCK ABSORBERS. <br />HOSE BRACKET <br />24" X 24" X 10" <br />ONE PIECE <br />MOLDED STONE <br />CORNER BASIN <br />a A. <br />MOP SINK DETAIL <br />NO SCALE <br />CID ® MOP HANGER <br />— SPOUT BRACE <br />SPOUT WITH HOSE <br />END & PAILHOOK <br />WALL STRUCTURE <br />CHROME PLATED <br />WATER HEATER 3/4"P&T <br />SERVICE FAUCET W/ <br />& 1" OVERFLOW RELIEF <br />VACUUM BREAKER <br />LINES IF APPLICABLE <br />—30" HOSE <br />DRAIN <br />a <br />o 4- <br />DIA. P-TRAP <br />1/2" TRAP PRIMER SUPPLY <br />DOMESTIC WATER LINE <br />TRAP PRIMER VALVE <br />DISTRIBUTION UNIT FOR <br />MULTIPLE LINES <br />1/2" TRAP PRIMER LINE <br />SLEEVE THRU "" <br />TRAP SEAL PRIMER DETAIL <br />NO SCALE <br />GENERAL NOTES <br />1. OFFSET ALL VTR'S, SANITARY, AND VENT STACKS AS REQUIRED. <br />2. ALL SAN. 2" AND SMALLER SHALL SLOPE UNIFORMLY NO LESS THAN <br />1/4"/FT, 3" AND LARGER SHALL SLOPE UNIFORMLY NO LESS THAN 1/8"/FT. <br />3. DRAWINGS ARE DIAGRAMMATIC AND SHOW LOCATION INTENT, BUT SHOULD <br />BE FOLLOWED AS CLOSE AS POSSIBLE CONTRACTOR IS TO COORDINATE <br />LAYOUTS WITH OTHER DISCIPLINES TO AVOID CONFLICTS AND FACILITATE <br />ACCESSIBILITY FOR SERVICING. <br />4. DESIGN INTENT CONSTITUTES THE PROVISIONS OF COMPLETE SYSTEM AS <br />INDICATED WITH ALL NECESSARY COMPONENTS AND ACCESSORIES, WHETHER <br />EXPLICITLY SPECIFIED OR IMPLIED, TO ACHIEVE FULL OPERATIONAL <br />STATUS. <br />5. DRAWINGS FROM VARIOUS DISCIPLINES ARE INTERRELATED, WHAT <br />IS REQUIRED IN ONE SHALL BE AS BINDING AS IF REQUIRED BY <br />ALL. COMPLEMENTARY COMPONENTS BETWEEN DISCIPLINES, <br />REASONABLY INFERRED AS BEING NECESSARY TO PRODUCE INTENDED <br />RESULTS, SHALL BE DEEMED PART OF THE CONTRACTOR'S EXPECTED <br />PERFORMANCE. <br />6. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND EXECUTION <br />OF ALL NECESSARY CHANGES ATTRIBUTABLE TO INSTALLATION OF SUBSTITUTE <br />EQUIPMENT AT NO ADDITIONAL COST TO OWNER. <br />7. DOMESTIC WATER PIPING: <br />CONTRACTOR TO INSTALL TYPE "L", DRAWN COPPER TUBE WITH WROUGHT COPPER <br />FITTINGS AND LEAD FREE SOLDER JOINTS FOR PIPE SIZES 4 INCHES AND SMALLER, <br />ABOVE GROUND, WITHIN BUILDING. CONTRACTOR TO INSTALL TYPE "K", ANNEALED <br />TEMPERED COPPER TUBE FOR PIPE SIZES 3 INCHES AND SMALLER, WITH MINIMUM <br />NUMBER OF JOINTS, BELOW GROUND. <br />8. SANITARY PIPING: <br />CONTRACTOR TO INSTALL STORM DRAINAGE (WHEN APPLICABLE), DRAINAGE, <br />DRAINAGE VENT PIPES AND FITTINGS AS FOLLOWS: <br />A. ABOVE GROUND DRAINAGE AND VENT PIPE: <br />1) CAST-IRON PIPE COMPLYING WITH ASTM A 74; CISPI 301; ASTM A 888 <br />9. ALL WORK SHALL COMPLY WITH THE 2007 FLORIDA BUILDING CODE. <br />10. NO GAS SERVICE REQUIRED IN THIS PROJECT. <br />PLUMBING LEGEND <br />— _ — CW — - — <br />COLD WATER LINE <br />— . . — HW — — <br />HOT WATER LINE <br />S <br />SANITARY WASTE LINE <br />— — V — — <br />SANITARY VENT <br />I-- WALL CLEANOUT <br />CO <br />SA <br />SHOCK ABSORBER <br />GATE VALVE <br />C PIPE DOWN <br />C PIPE UP <br />le TEE DN <br />TEE UP <br />"HOT" VALVE <br />FAUCET FLOW CONTROL /--" COLD" <br />VALVE <br />HOT WATER OUTLET <br />HOT WATER <br />HEATER <br />IN LINE FLOW <br />MOUNTING CONTROL <br />FLANG (1.0 GPM MAX) <br />HOT 13 <br />o COLD <br />COPPER <br />TUBING <br />ACCESS COVER FITTING <br />--- SINK <br />3/4" MAIN PIPE, <br />COLD WATER INLET <br />DUAL OUTLET ANGLE VALVE <br />ELECTRICAL JUNCTION BOX <br />ELECTRICAL CONDUIT <br />ELECTRICAL WIRES <br />TYPICAL "IWH" INSTANT WATER <br />HEATER MOUNTING DETAIL <br />NO SCALE <br />-M.ANA111: <br />.................. .... ...... ....................................................... ..................... <br />Project <br />HUMANA- ZEPHYRHILLS, <br />FLORIDA - GUIDANCE <br />CENTER <br />7920 GALL BLVD. <br />ZEPHYRHILLS, FLORIDA 33541 <br />Prepared for <br />HUMANA INC. <br />Contract No: 12.01622.00 <br />HOK <br />One Tampa City Center, Suite 1800 <br />Tampa, FL 33602 USA <br />t +1 813 229 0300 f +1 813 223 7116 <br />FL Reg: AAC001139 <br />All reproduction & intellectual property rights reserved © 2012 <br />In Association with <br />u: <br />................................... - - .................. <br />SDM Consulting Engineers <br />MEP Engineer <br />135 Almeria Ave. <br />Coral Gables, FL 33134 <br />305.446.2788 <br />www.sdmcorp.com <br />Key Plan <br />C' <br />Professional Seals <br />ERNESTO ALOMA JOSE I. MARTINEZ <br />P.E. 53823 P.E. 53779 <br />No. Issue Description YYYY-MM-DD <br />01 50% CONSTRUCTION DOCUMENTS 06.15.2012 <br />02 BID SET 06.29.2012 <br />03 ISSUE FOR PERMIT 07.27.2012 <br />No. Revision Description YYYY-MM-DD <br />1 ADDENDUM 1 2012-07-09 <br />2 ADDENDUM 2 2012-07-19 <br />Drawn by SDM Reviewed by SDM <br />Project No 12.01622.00 <br />Sheet Title: <br />GEN. NOTES, LEGENDS, <br />SCHEDULES & DETAILS <br />- PLUMBING <br />Original drawing is 36 x 24 Do not scale contents of this drawing <br />Sheet Number <br />