SYMBOLS
<br />ABBREVIATIONS
<br />GENERAL NOTES
<br />DEMOLITION NOTES
<br />— A —
<br />DUPLEX RECEPTACLE. FLUSH WALL MOUNTED UNLESS NOTED OTHERWISE
<br />A
<br />AMPERE
<br />QUAD RECEPTACLE. FLUSH WALL MOUNTED UNLESS NOTED OTHERWISE
<br />AFC
<br />ABOVE FINISHED CEILING
<br />AWG
<br />AMERICAN WIRE GAUGE
<br />DUPLEX RECEPTACLE. MOUNTED ABOVE COUNTER
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />DUPLEX EMERGENCY RECEPTACLE. FLUSH WALL MOUNTED.
<br />— B —
<br />BDC
<br />BYPASS DISTRIBUTION CABINET
<br />BLDG
<br />BUILDING
<br />®
<br />DUPLEX RECEPTACLE. FLOOR MOUNTED.
<br />BFC
<br />BELOW FINISHED CEILING
<br />®
<br />SPECIAL RECEPTACLE. FLOOR MOUNTED.
<br />— C —
<br />C
<br />CONDUIT
<br />®
<br />FLOOR MOUNTED POWER AND DATA OUTLET.
<br />CB
<br />CKT
<br />CIRCUIT BREAKER
<br />CIRCUIT
<br />CU
<br />COPPER
<br />FLOOR MOUNTED RECESSED SYSTEMS FURNITURE
<br />POWER AND DATA OUTLET.
<br />_ D _
<br />N
<br />DUPLEX TV RECEPTACLE. COORDINATE MOUNTING
<br />DEG
<br />DEGREE
<br />HEIGHTS WITH ARCHITECTURAL DRAWINGS.
<br />DISC
<br />DISCONNECT
<br />GFl
<br />DUPLEX GFl RECEPTACLE. FLUSH WALL MOUNTED.
<br />- E -
<br />EA
<br />EACH
<br />O
<br />POKE THRU FLOOR BOX, FLUSH FLOOR MOUNTED.
<br />ELEC
<br />ELECTRICAL
<br />E, EXIST. EX.
<br />EXISTING
<br />SPECIAL RECEPTACLE. FLUSH WALL MOUNTED UNLESS NOTED OTHERWISE
<br />EWH
<br />ELECTRIC WATER HEATER
<br />MOTOR
<br />_ F _
<br />f
<br />DEGREE FAHRENHEIT
<br />4
<br />JUNCTION BOX. WALL MOUNTED.
<br />FLEX
<br />FLEXIBLE
<br />- G -
<br />AV
<br />AUDIOVISUAL SINGLE GANG JUNCTION BOX. WALL MOUNTED.
<br />Y
<br />G, GND
<br />GROUND
<br />GFl
<br />GROUND FAULT INTERRUPTER
<br />P
<br />SYSTEMS FURNITURE RECESSED POWER OUTLET. WALL MOUNTED.
<br />Y
<br />- J -
<br />Y D
<br />SYSTEMS FURNITURE RECESSED TELECOM OUTLET. WALL MOUNTED.
<br />JB
<br />JUNCTION BOX
<br />JUNCTION BOX. CEILING MOUNTED.
<br />KV
<br />- K -
<br />KILOVOLT
<br />BP
<br />KVA
<br />KILOVOLT AMPERE
<br />FURNITURE POWER POLE
<br />KW
<br />KILOWATT
<br />M
<br />NF
<br />VOICE DATA RECEPTACLE. FLUSH WALL MOUNTED.
<br />1" CONDUIT TO ABOVE CEILING.
<br />MAX
<br />MAXIMUM
<br />MCB
<br />MAIN CIRCUIT BREAKER
<br />LPA 1,3,5
<br />CONDUIT HOMERUN TO PANELBOARD "LPA" CIRCUITS 1,3,5.
<br />MIN
<br />MINIMUM
<br />SURFACE MOUNTED PANELBOARD
<br />N
<br />❑T
<br />N
<br />NEUTRAL
<br />ELECTRICAL TRANSFORMER
<br />NL
<br />NIGHT LIGHT
<br />N.O.
<br />NORMALLY OPEN
<br />a
<br />CIRCUIT BREAKER DISCONNECT
<br />MECHANICAL EQUIPMENT
<br />P
<br />P
<br />POLE
<br />LIGHTING FIXTURE
<br />PAC
<br />PRE -ACTION CABINET
<br />R
<br />R = REMOVE AND RELOCATE
<br />PB
<br />PULL BOX
<br />E = EXISTING TO REMAIN
<br />0
<br />PHASE
<br />D = DEMOLISH
<br />PNL
<br />PANEL
<br />PWR
<br />POWER
<br />o
<br />LIGHTING RECESSED FIXTURE
<br />- R -
<br />EMERGENCY LIGHTING RECESSED FIXTURE
<br />R
<br />RELOCATED
<br />LIGHTING STRIP FIXTURE
<br />RECEPT
<br />RECEPTACLE
<br />REQ
<br />REQUIRED
<br />Q
<br />LIGHTING DOWNUGHT FIXTURE
<br />_ S _
<br />Q
<br />EMERGENCY LIGHTING DOWNUGHT FIXTURE
<br />SCHED
<br />SCHEDULE
<br />SP
<br />SINGLE POLE
<br />O
<br />LIGHTING DOWNLIGHT FIXTURE
<br />SN
<br />SOLID NEUTRAL
<br />SPEC
<br />SPECIFICATION
<br />AL
<br />LIGHTING EXIT SIGN
<br />_ T _
<br />V
<br />LIGHTING BATTERY PACK EXIT SIGN
<br />TRANSF
<br />TRANSFORMER
<br />TYP
<br />TYPICAL
<br />LIGHTING BATTERY PACK
<br />TV
<br />TELEVISION
<br />- U -
<br />TOGGLE LIGHTING SWITCH. MATCH EXISTING.
<br />UON
<br />UNLESS OTHERWISE NOTED
<br />UPS
<br />UNINTERRUPTED POWER SUPPLY
<br />3
<br />3-WAY TOGGLE UGHTING SWITCH.
<br />_ V _
<br />$D
<br />LIGHTING DIMMER SWITCH. COORDINATE TYPE WITH
<br />V
<br />VOLT OR VOLTAGE
<br />DIMMED FIXTURE TYPE.
<br />VA
<br />VOLT AMPERE
<br />VIM
<br />VOLTMETER
<br />OS
<br />WALL MOUNTED OCCUPANCY SENSOR. SEE OCCUPANCY
<br />SENSOR SCHEDULE ON SHEET E1.1.
<br />®
<br />CORNER MOUNTED OCCUPANCY SENSOR. SEE OCCUPANCY
<br />SENSOR SCHEDULE ON SHEET E1.1.
<br />ST
<br />FIRE ALARM STROBE - WALL
<br />0
<br />FIRE ALARM PULL STATION
<br />FIRE ALARM HORN/STROBE - WALL
<br />©
<br />SMOKE DETECTOR
<br />RAN
<br />FIRE ALARM REMOTE ANNUNCIATOR PANEL
<br />T�V TELEVISION BACKBOX AND RACEWAY.
<br />COORDINATE MOUNTING HEIGHTS WITH
<br />ARCHITECTURAL PLANS
<br />1 ALL SYMBOLS SHOW4 ON SYMBOL UST ARE NOT NECESSARILY USED ON THIS PROJECT. ALL WORK SHALL BE IN ACCORDANCE WITH, BUT NOT LIMITED TO, THE STATE OF FLORIDA AND LOCAL
<br />AUTHORITIES HAVING JURISDICTION.
<br />2 CUT AND PATCH TO MATCH ALL EXISTING CONSTRUCTION AS REQUIRED FOR THE PROPER INSTALLATION OF NEW ELECTRICAL NARK. ALL PATCHING SHALL BE OF THE SAYE MATERIALS,
<br />WOPo(MNVSI-IP AND FINISH AS EXISTING AND SHALL ACCURATELY MATCH ALL SURROUNDING WORK.
<br />3 UNLESS INSTRUCTED OTHERWISE, TIE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMTS,UCFNSES, AND FEES REQUIRED FOR INSTALLATION OF THE ELECTRICAL WORK. FURNISH FINAL
<br />CERTIFICATE OF INSPECTION OR WRITTEN EVIDENCE OF AOCEPTANCE BY INSPECTION AUTHORITIES FOR ALL WORK INSTALLED.
<br />4 BEFORE STARTING ANY WORK, 11E CONTRACTOR SHALL EXAMINE THE COMPLETE SET OF DRAWINGS VERIFY ALL DIMENSICNN$s SPACE REQUIREMENTS AND POINTS OF CONNECTION TO ALL EQUIPMENT,
<br />MAKE ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICTS WTH THE BUILDING STRUCTURE AND THE WORK OF 01HER TRADES
<br />5 TIE DRAWINGS INDICATE, IN A DIAGRAMMATIC MANNER, THE DESIRED LOCATIONS AND ARRANGEMENTS OF THE COMPONENTS OF THE ELECTRICAL NARK. DETERMINE EXACT CONDUIT ROUTING,
<br />CONDUIT BENDS, AUXILIARY JUNCTICN BOXES, SUPPORTS, AND UNDEFINED CONSTRUCTION DETAILS, AS A JOB CONDITION TO BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODE REQUIiEtiENT&
<br />6 THE WORK OF THIS PROJECT INVOLVES ALTERATION OF TIE EOOSTING BUILDING TO ACHIEIiE THE ARRANGEMENT INDICATED ON THE DRAWINGS THE CONTRACTOR SHALL VISIT THE JOB SITE TO
<br />DETERMINE THE EXTENT CF WORK REQUIRED BY THE CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL REVISE, REARRANGE, REROUTE OR REMOVE EXISTING WRING AS REQUIRED TO
<br />ACCOMMODATE THE CHANGES AND ADDITIONS SHOWN AND TO PROVIDE CONTINUING ELECTRICAL SERVICE TO THOSE EXISTING PORTIONS OF THE PROJECT WHICH ARE TO REMAIN IN OPERATION.
<br />7 THE ALTERATION OF THE EXISTING BUILDING IS A COMPLEX WORK IN NATURE WHICH WILL REQUIRE ACCURATE PLANNING, CAREFUL PREPARATION AND EXECUTION, ATTENTION TO DETAIL AND CLOSE
<br />SUPERVISION BY THE CONTRACTOR. THE CONTRACTOR WILL BE REQUIRED TO DO HIS WORK IN FULL COOPERATION WTH THE OTHER CONSTRUCTION TRADES
<br />8 BEFORE SUBMITTING PROPOSALS FOR THIS WORK, EACH BIDDER SHALL BECOME FAMILIAR WTH DRAWINGS AND SHALL HAVE EXAMINED THE PREMISES AND BE AWARE OF ALL EXISTING CONDITIONS
<br />U11DEER WHICH HE WILL BE OBUGATED TO CPERATE IN PERFORMING HIS CONTRACT. THE CONTRACTOR WILL NOT BE ENTITLED TO AN EXTRA CO FENNSATIIN FOR FAILURE TO ALLOW FOR ALL
<br />EXISTING CONDITIONS SUBMITTING OF A BID OR PROPOSAL WILL BE CONSIDERED EVIDENCE OF THE FACT THAT THE CONTRACTOR IS FULLY AWARE OF THESE CONDITIONS AND IS ABLE TO
<br />COMPLETE ALL WORK REQUIRED BY THE DRAWINGS
<br />9 ALL ELECTRICAL MATERIALS SHALL BE NEW AND BEAR LIE UNDERWRITERS (AND/OR EQUIVALENT TESTING AGENCY) LABEL
<br />10 ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2011 NATIONAL ELECTRICAL CODE, THE STATE OF FLORIDA BUILDING CODE AND ALL OTHER GOVERNING CODES AND ORDINANCES
<br />11 ALL PANELS, SWITCHES, ETC... SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS TO ACCOMMODATE CONDUCTORS SHOWN.
<br />12 THE CONTRACTOR SHALL VITRIFY THE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT AND OTHER EQUIPMENT REQUIRING ELECTRICAL CONNECTION PRIOR TO ROUGH —IN.
<br />13 ALL CONDUCTORS SHALL BE STRANDED COPPER TYPE THVW INMA110K ALUMINUM CONDUCTORS SHALL NOT BE USED ON THIS PROJECT.
<br />14 ALL JUNCTION BOXES AND PULL BOXES SHALL BE OF CODE GAUGE AND OF THE REQUIRED SIZE TO ACCOMMODATE NUMBER OF CONDUCTORS SHOWN.
<br />15 PROVIDE TYPEWRITTEN AS BUILT PANEL SCHEDULES TO BE MOUNTED ON INSIDE OF ALL PANEL COVER DOORS
<br />16 MAINTAIN CIRCUIT CONTINUITY TO THOSE AREAS NOT AFFECTED BY THE ALTERATION.
<br />17 INFORMATION OF AVAILABLE CIRCUITS TO BE USED FOR NEW WORK ON EXISTING PANRWARDS WAS OBTAINED FROM CONTRACTOR ASBUILTS CONTRACTOR SHALL VITRIFY ITS ACCURACY AND
<br />REASSIGN CIRCUIT NUMBERS AS REQUIRED. UPDATE PANEL DIRECTORY WITH LATEST INFORMATION AND SWITCH OFF ALL SPARE CIRCUIT BREAKERS.
<br />18 CONTRACTOR SHALL LABEL. ALL NEW ELECTRICAL EQUIPMENT PER BUILDING STANDARDS COORDINATE WITH BUILDING ENGINEER FOR EXACT REQUIREMENTS
<br />19 CONTRACTOR TO PROVIDE EQUIPMENT GROUND (EG) CONDUCTOR FOR ALL CIRCUITS, EXTEND EQUIPMENT CHUM TO ALL ELECTRICAL DEVICES PROVIDE EQUIPMENT GROUND BAR IN PANELS.
<br />20 FOR EXACT LOCATIONS OF RECEPTACLES, J—BOXES, LUMINAIRES, SWITCHES, ETC. SEE ARCHITECTURAL DRAWNGS
<br />21 ALL WAIL JUNCTION BOXES SHALL BE MOUNTED FLUSH WITH FINISHED FACE OF WALL. PROVIDE EXTENSION BOXES AT WALLS WITH APPLIED ACOUSTIC PANELS. ALL WALL JUNCTION BOXES SHALL
<br />BE INSTALLED WITH MOUNTING HOLES AT TOPE AND BOTTOM, UN ESS OTHERWISE NOTED.
<br />22 THE CONTRACTOR SHALL PROVIDE PULL CORDS IN ALL EMPTY CONDUITS. VHERE MORE THAN ONE CONDUIT TERMINATES IN A JUNCTION BOX, THE ELECTRICAL CONTRACTOR SHALL IDENTIFY EACH
<br />J—BOX AND CONDUIT IN A MANNER ALLOWNG IDENTIFICATION OF J—BOXES CONDUITS AFTER ALL WALL FINISHES HAVE BEEN APPLIED.
<br />23 PROVIDE FINISH TRIM ON ALL FLOOR ELECTRICAL BOXES. FINISH REQUIREMENTS SHALL BE DETERMINED BY ARCHITECT.
<br />24 MINIMUM SIZE OF CONDUITS SHALL BE 3/4 MINIMUM SIZE OF CONDUCTORS SHALL BE #12 AWG, U.O.N.
<br />25 THE CONTRACTOR SHALL EXTEND WRING FROM ALL JUNCTION BOXES, RECEPTACLES, SWITCHES, ETC., NO MAKE FINAL CONNECTION AS REQUIRED TO ALL EQUIPMENT REQUIRING ELECTRICAL
<br />CONNECTION.
<br />26 THE CONTRACTOR SHALL COORDINATE LOCATION OF ALL OUTLET BOXES FOR SWITCHES, RECEPTACLES, SPEAKERS, ETC,
<br />27 FOR ALL WRING DEVICES VERIFY FINISH COLOR WITH ARCHITECT.
<br />28 TYPE MC OR AC CABLES SHALL NOT BE USED.
<br />29 THESE DRAWNGS INDICATE THE FINISHED REQUIREMENTS FOR THE ELECTRICAL SYSTEMS, EQUIPMENT, LUMINAIRES, OUTLETS AND DEVICES DUE TO STRUCTURAL CONDITIONS, MECHANICAL DUCT OR
<br />PIPING INTERFERENCE, OR FOR OTHER REASONS, THE CONTRACTOR MAY DESIRE TO INSTALL THE WORK IN A MANNER DIFFERENT FROM THAT SHOWN. SUCH CHANGES SHALL BE PRESENTED TO THE
<br />OWNER'S REPRESENTATIVE FOR APPROVAL BEFORE PROCEEDING, AND THE RECORD DRAWINGS SHALL BE ACCURATELY REVISED TO SHOW THE CHANGES AS COMPLETED.
<br />30 ALL WORK SHALL COMPLY WITH THE STATE OF FLORIDA AND ALL OTHER GOVERNING CODES AND ORDINANCES INCLUDING BUILDING WRING STANDARDS
<br />31 INTERCONNECT FIRE ALARM STROBE LIGHT (+ED"AFF) WITH WIRE AND MINIMUM 1/2" CONDUIT AND ROUTE TO EXISTING LIFE SAFETY TE14ANAL CABNET. STROBE LIGHT TYPE AND WRING SHALL
<br />MATCH BUILDING STANDARD. CONTRACTOR TO COORDINATE WTH BUILDING FIRE ALARM SYSTEM CONTRACTOR FOR POWER SUPPLY REQUIREMENTS. PROVIDE NEW PONkR SUPPLY IF REQUIRED.
<br />32 EVERY OUTLET HEIGHT SHALL BE VERIFIED ON EACH WALL WITH INTERIOR PLANNING AND DESIGN DRAWINGS AND CABINET SHOP DRAWINGS TO ENSURE THE PROPER HEIGHT AND LOCATION WTH
<br />RESPECT TO CABINETS, EQUIPMENT, ETC.
<br />33 FOB TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL WALL SWITCHES.
<br />34 COORDINATE BOX LOCATION IN MILLWORK WITH ARCHITECT AND/OR MILLWORK CONTRACTOR
<br />35 THE CONTRACTOR SHALL INTERCONNECT ALL FANS AND AC UNITS WITH THE BUILDING LIFE SAFETY SYSTEM, FOR UNIT SHUT —DOWN UPON A SIGNAL FROM THE LIFE SAFETY SYSTEM. VERIFY WITH
<br />LIFE SAFETY SYSTEM CONTRACTOR.
<br />36 ALL J—BOXES SHALL BE SIZED PER NEC.
<br />37 CONTRACTOR SHALL PROVIDE COMPLETE RED LINED AS —BUILT DRAWINGS PRIOR TO COMPLETION OF PRO ECT FOR REVIEW BY ARC ITECT/1:NGINEE R.
<br />38 SEE ARCHITECTURAL DRAWINGS FOR SCOPE/EXTENT OF DEMOLITION, NEW CONSTRUCTION AND EXACT LIGHTING LOCATIONS AND QUANTITIES
<br />39 PROVIDE LIFE SAFETY SYSTEM COMPONENTS NECESSARY FOR A COMPLETE SYSTEM AS APPROVED BY FIRE MARSHALL AND OTHER ENFORCING AGENCIES HAVING JURISDICTION AND CONNECT TO
<br />EXISTING BASE BUILDING SYSTEM FOR PROPER OPERATION.
<br />40 ALL STROBE LIGHTS SHALL HAVE MINIMUM 75 CANDELA LIGHT INTENSITY, UNLESS NOTED OTHERWISE.
<br />41 THE ENTIRE INSTALLATION OF LIFE SAFETY SYSTEM INCLUDING MATERIALS AND EQUIPMENT SHALL BE COMPATIBLE WITH BASE BUILDING EQUIPMENT AND MEET OR EXCEED THE MINIMUM STANDARD
<br />AND REQUIREMENTS OF THE FOLLOWING`
<br />A U.L LISTING SERVICES
<br />B. N.F.P.A NATIONAL FIRE CODE
<br />C. LOCAL CITY FIRE AND BUILDING CODE
<br />D. LOCAL CITY CODE
<br />E STATE OF FLORIDA BUILDING CODE 5TH EDITION
<br />42 A DUPLEX RECEPTACLE INSTALLED ON AN INDIVIDUAL 20 AMP CIRCUIT BEAKER SHALL HAVE A 20 AMP RATING,
<br />43 ALL OUTLET, FACE PLATES (RECEPTACLE; SWITCHES, ETC.) COLOR AND MATERIAL SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL
<br />44 PROVIDE MINIMUM 6" SEPARATION FOR BACK TO BACK OUTLET BOXES.
<br />45 ALL RECESSED LUMINAIRES SH LL BE EQUIPPED WITH FRAMES AND SUPPORTS AS REQUIRED BY CEILING CONSTRUCTION. CONTRACTOR SHALL VIRIFY CEILING TYPES PRIOR TO ORDERING RECESSED
<br />LUMINAIRES AND ENSURE CORRECT MOUNTING METHOD FOR CONDITIONS CE INSTALLATION. LUMINAIRES SHALL BE SEALED TO PREVENT LIGHT LEAKS AND SHALL BE INSPECTED, APPROVED AND
<br />BEAR LABEL OF UNDERWRITERS LABORATORIES, INC.
<br />46 ALL WORK SHALL CONFORM TO HUMANA AND BUILDING STANDARDS.
<br />47 ALL OUTLETS, J—BOXES, EQUIPMENT SHALL BE LABELED WTH CIRCUIT DESICNJA110K LABELS SHALL BE LAMINATED TYPE CONSTRUCTION (BROTHER P—TOJCH II).
<br />WHITE WITH BLACK LETTERING — U11UTY SOURCE
<br />WHITE WITH RED LETTERING - SEP SOUI2CE
<br />WHITE WTH BLUE LETTERING - UPS SOURCE
<br />48 GENERAL CONTRACTOR TO COORDINATE WTH BUILDING ENGINEER FOR PREFERRED SUB -CONTRACTORS.
<br />49 REFER TO BUILDING STANDARD SPECIFICATION FOR ALL NEW EQUIPMENT INSTALLED.
<br />50 IMU_TIWRE BRANCH CIRCUITS ARE NOT ALLOWED. ALL CIRCUITS SHALL CONTAIN A DEDICATED NEUTRAL SIZED AT 100% OF THE CIRCUIT CAPACITY.
<br />51 MINIMUM CIRCUIT WIRE SIZE SHALL BE #12 AWG.
<br />1 CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY POWER AND LIGHTING FOR THE DURATION OF THE
<br />CONSTRUCTION EFFORT. BUILDING POWER CAN BE USED WITH PRIOR APPROVAL TO ENSURE ADEQUATE
<br />SUPPLIES.
<br />2 PROVIDE TYPE AND SIZE OF CONDUCTORS TO MATCH EXISTING FOR EXISTING CIRCUITS WHICH ARE EXTENDED
<br />TO SERVE NEW OR RELOCATED DEVICES OR FIXTURES.
<br />3 FIELD VERIFY EXISTING CIRCUITING AND MAKE ADJUSTMENTS AS NECESSARY TO THE CIRCUITING SHOWN ON THE
<br />PLANS, AS REQUIRED BY FIELD CONDITIONS.
<br />4 REMOVE ALL UNUSED CONDUITS AND WIRING, SWITCHES, RECEPTACLES, LUMINAIRES, ETC., WHERE CEILINGS,
<br />CEILING TILES OR WALLS ARE BEING DEMOLISHED EXCEPT AS FOLLOWS: WHERE WALLS AND CEILING ARE TO
<br />REMAIN. MAINTAIN EXISTING CONDUIT, WIRING AND BOXES SERVING ALL ELECTRICAL EQUIPMENT, OUTLETS AND
<br />SWITCHES IN THOSE AREAS. REMOVE ALL POWER WIRING BACK TO ITS OVERCURRENT DEVICE AND MARK
<br />CIRCUIT BREAKERS AS "SPARE". INSTALL BLANK COVERS ON ALL BOXES. REFER TO DRAWINGS FOR ADDITIONAL
<br />REQUIREMENTS AND OTHER SPECIFIC EXCEPTIONS.
<br />5 COORDINATE ALL DEMOLITION WORK WITH NEW REQUIREMENTS TO ASSURE THAT EXISTING EQUIPMENT, WIRING,
<br />ETC., THAT IS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM IS NOT REMOVED.
<br />6 ALL EXISTING ELECTRICAL EQUIPMENT AND CONDUITS THAT INTERFERE WITH ANY NEW CONSTRUCTION SHALL BE
<br />RELOCATED OR RE—ROUTED AS REQUIRED TO CLEAR THE NEW CONSTRUCTION. RECONNECT ALL EXISTING
<br />EQUIPMENT THAT ARE TO REMAIN AND NOT AFFECTED BY THE NEW CONSTRUCTION, TO THE NEWLY RELOCATED
<br />OR RE—ROUTED SYSTEM TO ENSURE A SAFE AND OPERATIONAL SYSTEM.
<br />7 DISCONNECT AND RECONNECT THE EXISTING ELECTRICAL EQUIPMENT AS REQUIRED BY THE CONSTRUCTION
<br />MODIFICATIONS.
<br />9 REMOVE ALL EXISTING LUMINAIRES, WIRING DEVICES, ELECTRICAL EQUIPMENT AND CIRCUIT, WHETHER
<br />SPECIFICALLY INDICATED OR NOT, AS REQUIRED DUE TO THE ARCHITECTURAL AND MECHANICAL DEMOLITION
<br />WORK IN THE AREA TO BE RENOVATED. ALL EQUIPMENT THAT HAS BEEN REMOVED AND IS NOT REUSED SHALL
<br />BE RETURNED TO THE OWNER, OR DISPOSED OF AS DIRECTED BY THE OWNER'S REPRESENTATIVE.
<br />10 RECONNECT CIRCUITING AS REQUIRED TO MAINTAIN CONTINUITY TO REMAINING OUTLETS WHEN EXISTING
<br />LUMINAIRES AND DEVICES ARE REMOVED. CONSOLIDATE PARTIALLY LOADED CONVENIENCE RECEPTACLE CIRCUITS
<br />TO MAXIMIZE SPACE MADE AVAILABLE AT THE PANELBOARD. TRACE CONSOLIDATED 20 AMP, 120 VOLT CIRCUITS
<br />TO VERIFY THAT THE TOTAL LOAD DOES NOT EXCEED 1900 VOLT AMPERES.
<br />11 PROVIDE EXTENSION RINGS, COVER PLATES OR ACCESS DOORS AS NECESSARY TO MAINTAIN ACCESS TO
<br />EXISTING WIRING, WHERE REQUIRED BY NEW CONSTRUCTION. ALL ACCESS DOOR LOCATIONS SHALL BE REVIEWED
<br />BY ARCHITECT PRIOR TO INSTALLATION.
<br />12 FIELD VERIFY LOCATIONS OF EXISTING OUTLETS. WHERE NEW CONSTRUCTION CONFLICTS WITH EXISTING OUTLETS,
<br />REMOVE WIRING DEVICES OR RELOCATE LUMINAIRES AS REQUIRED, WHETHER OR NOT SPECIFICALLY INDICATED.
<br />13 PROVIDE BLANK COVER PLATES ON JUNCTION BOXES WHICH ARE NOT REUSED.
<br />14 PROVIDE CUTTING AND PATCHING AS REQUIRED, WHETHER OR NOT SPECIFICALLY INDICATED. VERIFY EXTENT OF
<br />NEW AND EXISTING PARTITIONS WITH ARCHITECTURAL DRAWINGS.
<br />15 MODIFY AND RECONNECT THE EXISTING ELECTRICAL EQUIPMENT AS REQUIRED TO REMAIN, AND NOT AFFECTED
<br />BY THE NEW CONSTRUCTION, TO ENSURE THE FINAL SYSTEM WILL FUNCTION IN A SAFE MANNER ACCEPTABLE
<br />TO AUTHORITIES.
<br />16 IN PERFORMANCE OF DEMOLITION WORK, CONTRACTOR SHALL COORDINATE ALL WORK WITH THE BUILDING
<br />MANAGMENT SO AS NOT TO INTERRUPT THE OPERATIONS OF THE BUILDING. COORDINATE WITH THE BUILDING
<br />ENGINEER FOR SHUTDOWN SCHEDULING AND APPROVAL.
<br />17 OWNER RESERVES FIRST RIGHT OF REFUSAL FOR ALL DEMOLISHED ITEMS. ANY EQUIPMENT NOT WANTED BY THE
<br />OWNER IS THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF IN PROPER FASHION. PROVIDE RECEIPT OF
<br />DISPOSAL OF HAZARDOUS WASTE ITEMS SUCH AS PCB'S.
<br />18 REMOVE ALL ABANDONED AND NOT USED DATA CABLING ABOVE CEILING, WITHIN WALLS AND RACEWAYS.
<br />BRANCH CIRCU I T S
<br />BRANCH CIRCUIT VOLTAGE DROP (3%)
<br />The Contractor shall provide minimum sized branch circuit conductors per the table below
<br />Conductor Branch Circuit Circuit Voltage
<br />size (AWG) OCD (Amps) 1 120 208 1 240 1 277
<br />Maximum Allowable Lenath (ft)
<br />12
<br />15
<br />82
<br />142
<br />164
<br />189
<br />10
<br />15
<br />135
<br />235
<br />271
<br />313
<br />8
<br />15
<br />205
<br />356
<br />411
<br />474
<br />12
<br />20
<br />61
<br />1 107
<br />1 123
<br />1 142
<br />10
<br />20
<br />102
<br />1 176
<br />1 203
<br />234
<br />8
<br />20
<br />154
<br />1 267
<br />1 308
<br />356
<br />10 1 30 103 178 205 237
<br />8 30 160 277 320 369
<br />Notes:
<br />1. Assuming single phase circuit, 90% power factor, uncoated copper
<br />conductors in steel raceway from NEC Chapter 9, Table 9.
<br />2. Assuming load equal to 80% of OCD rating is concentrated at the
<br />end of the circuit.
<br />3. Longer branch circuit lengths shall be allowed when the circuit load is
<br />known and the Contractor has provided a voltage drop calculation.
<br />The calculation results shall be marked on the As -Built plans.
<br />LINE WEIGHT DESIGNATIONS
<br />LIGHT LINE WEIGHT INDICATES EXISTING TO REMAIN UON.
<br />DARK LINE WEIGHT INDICATES NEW WORK UON.
<br />ELECTRICAL DRAWING INDEX
<br />SHEET
<br />DESCRIPTION
<br />E-0.1
<br />ELECTRICAL COVER SHEET
<br />E-0.2
<br />ELECTRICAL SPECIFICATIONS
<br />E-1.0
<br />ELECTRICAL LIGHTING PLANS
<br />E-2.0
<br />ELECTRICAL POWER PLANS
<br />E-5.0
<br />ELECTRICAL PANEL SCHEDULES
<br />SCALE
<br />NONE
<br />NONE
<br />1 /8' = 1'-0"
<br />1 /8" = 1'-0"
<br />NONE
<br />a
<br />2017 -Humana
<br />Zephyrhills Guidance
<br />Center
<br />7920 GALL BLVD.
<br />ZEPHYRHILLS, FL
<br />33541
<br />Rio®
<br />SYsm HuNmssY
<br />GROUP
<br />A member company of SH Group, Inc.
<br />Syska Hennessy group, Inc
<br />9000 Southside Blvd.
<br />Building 100, 1st Floor
<br />Jacksonville, FI 32256
<br />Tel: 904.525.8669
<br />www.syska.com
<br />Florida C.O.A. #00001897
<br />JAY J. LANE FL# 71396
<br />1 ISSUE FOR CONSTRUCTION 4/18/18
<br />Delta Issue Description Date
<br />Nr.
<br />DECLARATIVE STATEMENT. TO THE BEST OF THE ENGINEER'S
<br />KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH
<br />THE APPLICABLE MINIMUM BUILDING CODES AND THE
<br />APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY
<br />THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER
<br />533.70 AND CHAPTER 633, FLORIDA STATUTES.
<br />Drawn: EF Check: JL Owner Approval:
<br />Job No: HUM 17390 Scale: NONE
<br />ELECTRICAL
<br />Title: COVER SHEET
<br />Sheet: ■
<br />
|