My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7920 Gall Blvd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
7920 Gall Blvd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 11:04:23 PM
Creation date
1/21/2025 3:53:21 PM
Metadata
Fields
Template:
Building Plans
Street #
7920
Location
Gall Blvd
Contractor
ABI Companies Inc
Building Plans - Permit #
13397
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYPE <br />MANUFACTURER <br />SERIES <br />TECHNOLOGY <br />MOUNTING <br />VOLTAGE <br />COVERAGE <br />REMARKS <br />MATCH EXISTING AREA SWITCHES <br />ON/OFF <br />WALL BOX <br />120 <br />N/A <br />COORDINATE COLOR AND FINISH <br />WITH ARCHTIECTURAL DRAWINGS <br />$D <br />MATCH EXISTING AREA SWITCHES <br />120V LINE <br />VOLTAGE DIMMING <br />WALL BOX <br />120 <br />I I <br />N/A <br />COORDINATE COLOR AND FINISH <br />I WITH ARCHTIECTURAL DRAWINGS <br />$LV <br />MATCH EXISTING AREA SWITCHES <br />0-10V DIMMING <br />WALL BOX <br />120 <br />N/A <br />COORDINATE COLOR AND FINISH <br />WITH ARCHTIECTURAL DRAWINGS <br />mime <br />i Yi , , ✓ r <br />I GE GE 0E <br />f <br />/ <br />R <br />OS E O <br />i 2 <br />! <br />`I <br />r <br />E E E ' <br />E E E <br />E f rr4 ✓-- <br />_. E 41 <br />®E Ewa ' f l/ a <br />% f <br />i . <br />,. <br />JE E E <br />r r. <br />'f I <br />/ f , <br />LIGHTING FIXTURE SCHEDULE <br />TYPE <br />MANUFACTURER <br />MODEL NUMBER <br />LAMPS <br />ELECTRICAL <br />MOUNTING <br />DESCRIPTION <br />VOLTS VA <br />LT-10 <br />GM LIGHTING <br />LTR30024-35 / LTH-60—DIM <br />3500K / LED <br />120 <br />2.2/FT <br />SURFACE <br />HIGH OUTPUT LED WHITE STRIP LIGHT. 198 LUMENS/FOOT. 12/24VDC LED MAGNETIC DIMMABLE 60W <br />POWER SUPPLY, AUTO RESET, 120/240/277VAC INPUT, 50/60HZ, NO EXTERNAL FUSING REQUIRED. <br />LOCATE POWER SUPPLY ABOVE ACCESSIBLE CEILING SPACE. COORDINATE EXACT POWER SUPPLY <br />LOCATION IN THE FIELD WITH THE ARCHITECTURAL DRAWINGS. PROVIDE ACCESSORIES AS REQUIRED. <br />LT-11 <br />INTENSE LIGHTING <br />SS4G3DR—L2-358—L100— <br />3500K / LED <br />120 <br />16 <br />SURFACE <br />4" RECESSED LED ROUND DOWNLIGHT. SELF —FLANGED. 80 CRI. 0-10V DIMMING 17. C—CHANNEL <br />IC43OHZ—SF2 <br />BAR HANGERS. <br />NOTES: <br />1. COORDINATE THE EXACT LOCATIONS OF ALL FIXTURES WITH THE ARCHITECTURAL DRAWINGS. <br />2. COORDINATE FIXTURE FINISHES AND COLORS WITH ARCHITECTURE. <br />3. MANUFACTURERS LISTED HAVE BEEN APPROVED FOR THIS PROJECT. OTHER MANUFACTURERS <br />MAY BE ACCEPTABLE <br />AFTER A THOROUGH <br />REVIEW OF PRODUCT BY THE ENGINEER. <br />ALL SUBSTITUTIONS MUST BE SUBMITTED NO LESS THAN 10 DAYS PRIOR TO REQUIRED APPROVAL. <br />4. SUBSTITUTION PRODUCTS MAY REQUIRE SAMPLES OF MATERIALS, FINISHES OR COMPLETE, OPERATIONAL SAMPLE <br />FOR EVALUATION BY THE ENGINEER. <br />// <br />r/ <br />E E E <br />ELECTRICAL LIGHTING PLAN DEMOLITION <br />SCALE:1/8" = 1'-0" <br />�; f'�'r r',y r'/!' ���J/� �rif % '' s , • ,;'>'/! �, , r ` ✓r'",'�'• <br />,r r <br />zd�'/% <br />a_. <br />H 72CNI H-72C� H-720N N H-72 <br />LT-11 LT-11 LT-11 a LT-10 a�� <br />LV <br />OE of of <br />OS <br />E <br />R 0 <br />/ r <br />E E E <br />i_ E� <br />f <br />I <br />E E E � ,� ✓' ,r'�' <br />$$ E ,r r <br />�- - <br />Y`--,`—a <br />, <br />f <br />2 ELECTRICAL LIGHTING PLAN NEW WORK <br />1'-0" <br />j PE DE DE <br />f Q5 5 <br />0 <br />f OR R R A <br />/x O3 $ R <br />/ <br />f f f <br />f r/rfr/, <br />PANEL"H" <br />PANEL„H" <br />d <br />, <br />f PANEL"H" <br />SEC1 <br />PANEL',H" <br />a, SEC2 <br />- II <br />f <br />/✓ s <br />_ <br />GENERAL NOTES: <br />1. EXISTING EQUIPMENT SHOWN HAS BEEN <br />CONFIRMED WITH LIMITED FIELD SURVEY. <br />CONTRACTOR SHALL FIELD VERIFY ALL <br />EQUIPMENT. <br />2. CONTRACTOR SHALL FIELD VERIFY EXISTING <br />DEVICES PRIOR TO THE START OF DEMO. <br />3. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR <br />EXACT EXTENT OF DEMOLISHED WALLS AND <br />CEILINGS. <br />4. DEVICE LEGEND <br />"E" = EXISTING TO REMAIN <br />"" <br />D = EXISTING TO BE DEMOLISHED <br />"R" = RELOCATED OR TO BE RELOCATED <br />5. FOR DEMOLITION ITEMS REMOVE ALL ASSOCIATED <br />EQUIPMENT, CONDUIT, AND WIRE BACK TO <br />SOURCE OR NEAREST UPSTREAM DEVICE. <br />6. ENSURE THAT DEMOLITION OF ANY ONE DEVICE <br />DOES NOT DE—ERNERGIZE EXISTING DEVICES <br />THAT ARE TO REMAIN. <br />7. ALL DEMOLISHED ITEMS SHALL BE DISPOSED OF <br />PROPERLY. <br />8. ALL WORK SHALL BE DONE IN A SAFE MANNER <br />WITHOUT ANY DISTURBANCE TO BUILDING DAILY <br />OPERATION. <br />9. MAINTAIN GENERAL AND EXIT LIGHTING DURING <br />DEMOLITION AND CONSTRUCTION PER OSHA <br />STANDARD 29. <br />10. DEMOLISHED ITEMS ARE INDICATED IN DASHED <br />LINE WORK. <br />11. COORDINATE EXACT FIXTURE LAYOUT WITH <br />ARCHITECTURAL DRAWINGS. <br />12. PROVIDE ALL NECESSARY HARDWARE, SUPPORT <br />AND ACCESSORIES FOR COMPLETE INSTALLATION. <br />13. COORDINATE ALL WORK WITH ALL TRADES. <br />FIXTURE PLACEMENT SHALL BE COORDINATED <br />WITH MECHANICAL AND ARCHITECTURAL <br />ELEMENTS TO ELIMINATE CONFLICTS. DEVICE <br />PLACEMENT SHALL BE COORDINATED WITH <br />EQUIPMENT LOCATIONS. <br />14. LIGHTING CONTROLS SHALL CONTROL LIGHT <br />FIXTURES WITHIN THE SAME ROOM UNLESS <br />OTHERWISE NOTED. <br />15. PROVIDE REVISED PANEL SCHEDULE INDICATING <br />CHANGES TO CIRCUITS FOR ALL PANELS <br />IMPACTED BY SCOPE OF WORK. <br />16. ALL DEVICE PLATES ARE TO BE LABELED WITH <br />A P—TOUCH ADHESIVE LABEL INDICATING <br />SOURCE PANEL AND CIRCUIT NUMBER. LABEL <br />TO BE INSTALLED ON THE FACE PLATE OF EACH <br />DEVICE. <br />17. COORDINATE EXACT LOCATION, MOUNTING HEIGHT <br />AND ALIGNMENT DETAILS OF ALL DEVICES WITH <br />THE ARCHITECTURAL, A/V, SECURITY AND <br />FURNITURE DRAWINGS BEFORE INITIATING WORK. <br />ELECTRICAL NOTES: <br />01 EXISTING LIGHTING FIXTURES AND LIGHTING CONTROL <br />DEVICES IN THIS AREA ARE EXISTING TO REMAIN <br />UNLESS OTHERWISE NOTED. <br />O2 DISCONNECT AND REMOVE EXISTING WALL SWITCH. <br />ASSOCIATED WIRING AND RACEWAY SHALL REMAIN FOR <br />REUSE. MAINTAIN SWITCH FOR REUSE. <br />Q3 RELOCATED WALL SWITCH. REWORK AND EXTEND <br />EXISTING WIRING AND RACEWAY AS REQUIRED. <br />® ALL NEW LIGHTING FIXTURES SHALL BE CONTROLLED <br />BY EXISTING OCCUPANCY SENSOR. PROVIDE POWER <br />PACKS AS REQUIRED. MAKE ALL FINAL CONNECTIONS <br />AS REQUIRED. <br />Q RELOCATED LIGHT FIXTURE. REWORK AND EXTEND <br />EXISTING WIRING AND RACEWAY AS REQUIRED. <br />2017 -Humana <br />Zephyrhills Guidance <br />Center <br />7920 GALL BLVD. <br />ZEPHYRHILLS, FL <br />33541 <br />dl <br />Sym HENNESSY <br />GROUP <br />A member company of SH Group, Inc. <br />Syska Hennessy group, Inc <br />9000 Southside Blvd. <br />Building 100, 1st Floor <br />Jacksonville, FI 32256 <br />Tel: 904.525.8669 <br />www.syska.com <br />Florida C.O.A. #00001897 <br />• N 7 A <br />STATE OF <br />() NA L <br />',j <br />/111I I L1100 <br />JAY J. LANE FL# 71396 <br />1 ISSUE FOR CONSTRUCTION 4/18/18 <br />Delta Issue Description Date <br />Nr. <br />DECLARATIVE STATEMENT: TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH <br />THE APPLICABLE MINIMUM BUILDING CODES AND THE <br />APPLICABLE FIRE —SAFETY STANDARDS AS DETERMINED BY <br />THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER <br />533.70 AND CHAPTER 633, FLORIDA STATUTES. <br />Drawn: EF Check: JL Owner Approval: <br />Job No: HUM17390 Scale: 1/8" = 1-0" <br />ELECTRICAL <br />LIGHTING PLANS <br />Title: <br />E-1 <br />0 <br />Sheet: ■ <br />
The URL can be used to link to this page
Your browser does not support the video tag.