...CONTINUED <br />B)TESTED ACCORDING TO NEMA TP 2. <br />4. K-FACTOR RATING: TRANSFORMERS INDICATED <br />I. FIRE ALARM SYSTEM <br />TO BE K-RATED SHALL COMPLY WITH UL 1561 <br />1. FIRE ALARM SYSTEM IS EXISTING. NEW DEVICES <br />REQUIREMENTS FOR NON -SINUSOIDAL LOAD <br />SHALL MATCH BUILDING STANDARD. <br />CURRENT -HANDLING CAPABILITY TO THE DEGREE <br />DEFINED BY DESIGNATED K-FACTOR. <br />2. ALL FIRE ALARM DEVICES SHALL BE WHITE IN <br />COLOR. <br />A)UNIT SHALL NOT OVERHEAT WHEN CARRYING <br />FULL -LOAD CURRENT WITH HARMONIC <br />3. PROVIDE FIRE ALARM SYSTEM DEVICES AND <br />DISTORTION CORRESPONDING TO DESIGNATED <br />COMPONENTS NECESSARY FOR A COMPLETE <br />K-FACTOR. <br />SYSTEM AND CONNECT TO EXISTING BASE BUILDING <br />SYSTEM. THE WORK SHALL INCLUDE, BUT NOT <br />B)INDICATE VALUE OF K-FACTOR ON <br />LIMITED TO THE FOLLOWING. <br />TRANSFORMER NAMEPLATE. <br />A) EMERGENCY SIGNALING AND PAGING <br />5. FACTORY -ASSEMBLED AND TESTED, AIR-COOLED <br />SPEAKERS/HORNS. <br />UNITS FOR 60 HZ SERVICE. <br />B) FLASHING STROBES. <br />6. CORES: GRAIN -ORIENTED, NON -AGING SILICON <br />STEEL. <br />C)CONDUIT, WIRING, OUTLETS, ETC. REQUIRED <br />7, ELECTROSTATIC SHIELDING FOR ALL <br />PROVIDING POWER TO AND INTERCONNECTING ALL <br />TRANSFORMERS PROVIDED. <br />COMPONENTS LISTED ABOVE. <br />8. COILS: CONTINUOUS WINDINGS WITHOUT <br />4. THE ENTIRE INSTALLATION, INCLUDING MATERIALS <br />SPLICES EXCEPT FOR TAPS. <br />AND EQUIPMENT SHALL BE COMPATIBLE WITH <br />EXISTING BUILDING EQUIPMENT AND MEET OR <br />A)INTERNAL COIL CONNECTIONS: BRAZED OR <br />EXCEED THE MINIMUM STANDARDS AND <br />PRESSURE TYPE. <br />REQUIREMENTS STATED HERE -IN. <br />B)COIL MATERIAL: COPPER. <br />5. ALL EQUIPMENT AND MATERIALS USED SHALL BE <br />STANDARD COMPONENTS, REGULARLY <br />8• MANUFACTURER: SUBJECT TO COMPLIANCE <br />MANUFACTURED AND OF THE SAME MANUFACTURER, <br />WITH REQUIREMENTS, PROVIDE PRODUCTS BY <br />AS THE EXISTING BASE BUILDING EQUIPMENT. <br />THE FOLLOWING: <br />6. IONIZATION SMOKE SENSORS SHALL BE ANALOG <br />A)SQUARE D; SCHNEIDER ELECTRIC. <br />AND FULLY ADDRESSABLE AND SHALL BE MOUNTED <br />B)GENERAL ELECTRIC <br />ON A PLUG-IN BASE. SENSORS SHALL BE RATED <br />FOR THE AIR SPEED AT THE POINT OF <br />INSTALLATION. BASES SHALL BE COMPATIBLE WITH <br />K. LIGHTING FIXTURES: <br />BOTH IONIZATION AND PHOTOELECTRIC SENSORS. <br />1. FABRICATION AND MANUFACTURE: <br />7. PHOTOELECTRIC SMOKE SENSORS SHALL BE <br />ANALOG AND FULLY ADDRESSABLE AND SHALL BE <br />A) FIXTURES SHALL COMPLY WITH UL STANDARDS. <br />MOUNTED ON A PLUG-IN BASE. SENSORS SHALL <br />FIXTURES AHD COMPONENTS SHALL BE UL LISTED <br />BE RATED FOR THE AIR SPEED AT THE POINT OF <br />AND LABELED. <br />INSTALLATION. BASES SHALL BE COMPATIBLE WITH <br />B) VERIFY TYPES OF CEILING CONSTRUCTION WITH <br />BOTH IONIZATION AND PHOTOELECTRIC SENSORS. <br />ARCHITECT PRIOR TO RELEASING FIXTURES FOR <br />8. ADDRESSABLE CONTROL MODULES SHALL BE FULLY <br />FABRICATION AND DELIVERY AND PROVIDE <br />ADDRESSABLE AND MOUNTED WITHIN 3 FEET OF <br />FIXTURES ADAPTED TO CEILING CONSTRUCTION <br />THE CONTROLLED DEVICE. <br />USED. <br />9. HORNS SHALL PROVIDE SOUND LEVELS 15DBA <br />C)COORDINATE RECESSED FIXTURE MOUNTING <br />ABOVE AVERAGE AMBIENT SOUND LEVEL. <br />APPURTENANCES, FLANGES AND TRIMS WITH <br />COMBINED LEVEL OF HORNS AND AVERAGE <br />CONSTRUCTION OF CEILING IN WHICH FIXTURE IS <br />AMBIENT SOUND LEVEL SHALL NOT EXCEED <br />TO BE RECESSED. PROVIDE CORRECT FIXTURE <br />11ODBA. <br />MOUNTING ASSEMBLY. <br />10. STROBES SHALL BE FULLY SYNCHRONIZED AND <br />D) PROVIDE FIXTURES WITH FINISH AS DESCRIBED IN <br />SHALL HAVE CANDLEPOWER RATINGS DETERMINED <br />THE LIGHTING FIXTURE SCHEDULE. FINISH SHALL <br />IN ACCORDANCE WITH UL 1971. <br />BE APPLIED BY THE FIXTURE MANUFACTURER. <br />11. COMPLY WITH A.DA AND WITH FLORIDA BUILDING <br />VERIFY FINAL FINISH REQUIREMENTS BEFORE <br />CODE REQUIREMENTS. <br />RELEASING FIXTURES FOR FABRICATION. <br />12.NEW SPEAKERS AND STROBES LIGHTS SHALL <br />E)RECESSED FLUORESCENT TROFFERS WITH DOORS <br />MATCH BUILDING STANDARD. <br />SHALL HAVE SPRING LOADED DOOR CAM <br />LATCHES. <br />13.FIRE ALARM WIRING SHALL BE INSTALLED PER <br />LOCAL CODE AND NFPA 72. <br />2. ELECTRONIC FLUORESCENT BALLASTS: <br />14. THE SYSTEM AND ALL COMPONENTS SHALL BE UL <br />A) ETL CERTIFIED, CBM AND UL LISTED AND MEET <br />LISTED AND FM APPROVED SPECIFICALLY FOR <br />OR EXCEED NEMA AND ANSI STANDARDS. <br />OPERATION IN CONJUNCTION WITH EACH OTHER <br />B) CLASS P THERMALLY PROTECTED AND CLASS A <br />AND WITH THE SUPPRESSION SYSTEM, IF A <br />SUPPRESSION SYSTEM IS PROVIDED. <br />SOUND RATED. <br />15. FIRE ALARM EQUIPMENT SHALL BE USED FOR ITS <br />C) LOCATED IN FIXTURE WHICH THEY SERVE. <br />INTENDED PURPOSE ONLY. <br />D)OPERATE LAMPS AS SCHEDULED AND SHALL <br />16. SUBMITTALS: SUBMITTALS SHALL CONSIST OF THE <br />MAINTAIN CONSTANT LIGHT OUTPUT OVER ENTIRE <br />FOLLOWING DATA TO BE SUBMITTED CONCURRENTLY <br />OPERATING VOLTAGE RANGE. <br />AS ONE PACKAGE. SUBMITTALS WHICH DO NOT <br />E) MAINTAIN THE FOLLOWING PERFORMANCE: <br />INCLUDE SHOP DRAWINGS WILL BE RETURNED <br />WITHOUT REVIEW. <br />1) LAMP CURRENT CREST FACTOR: 1.6 <br />A) COMPLETE POINT TO POINT WIRING DIAGRAM <br />2) TOTAL HARMONIC DISTORTION: 10% <br />INDICATING ALL DEVICE ADDRESSES, SIGNAL <br />3) POWER FACTOR: 0.90 <br />CIRCUITS, AND CONDUCTOR QUANTITIES IN PLAN <br />VIEW AND RISER STYLE. CONCEPTUAL DIAGRAM <br />F)ALL BALLASTS FOR ALL LAMPS SHALL BE <br />WILL BE REJECTED. <br />PROGRAM START TYPE. <br />B)THE CONTRACTOR SHALL SUBMIT COMPLETE <br />G)DIMMING BALLASTS SHALL BE TYPE AND <br />DOCUMENTATION SHOWING THE TYPE, SIZE, <br />MANUFACTURER AS INDICATED ON FIXTURE <br />RATING, STYLE, CATALOG NUMBER, <br />SCHEDULE. <br />MANUFACTURER'S NAMES, AND CATALOG DATA <br />SHEETS, FOR ALL ITEMS TO ENSURE COMPLIANCE <br />3. LAMPS: <br />WITH THESE SPECIFICATIONS. REQUIRED COPES <br />A) PROVIDE LAMPS FROM THE SAME MANUFACTURER <br />OF THIS INFORMATION SHALL BE SUBMITTED TO <br />IN ALL FIXTURES WITH SAME LAMP TYPES. <br />THE ENGINEER AND SHALL BE SUBJECT TO HIS <br />B) LINEAR FLUORESCENT LAMPS SHALL HAVE A <br />APPROVAL <br />MINIMUM CRI OF 80. <br />C)BATTERY CALCULATIONS (IN ALARM) FOR THE <br />C)COMPACT FLUORESCENT LAMPS SHALL HAVE A <br />FACP AND AUDIO AMPLIFIER. <br />MINIMUM CRI OF 82. <br />D) CONTRACTOR SHALL DEVELOP DOCUMENTS, <br />SIGNED AND SEALED BY OTHERS, TO THE LOCAL <br />PART 3 - EXECUTION <br />3.1 INSTALLATION <br />AUTHORITY AS THE LOCAL AUTHORITY REQUIRES <br />FOR PERMIT. <br />M. GENERAL <br />17.PROJECT RECORD DOCUMENTS: <br />1. COMMON REQUIREMENTS FOR ELECTRICAL <br />INSTALLATION: <br />A) LOCATION OF THE CONTROLS, ALARM ACTUATING <br />DEVICES AND AUDIBLE ALARM SIGNALING DEVICES <br />K) MEASURE INDICATED MOUNTING HEIGHTS TO <br />SHALL BE AS SHOWN ON THE PLANS. ANY <br />BOTTOM OF UNIT FOR SUSPENDED ITEMS AND TO <br />NECESSARY DEVIATIONS SHALL BE APPROVED BY <br />CENTER OF UNIT FOR WALL MOUNTED ITEMS. <br />THE ENGINEER AND INDICATED ON AS -BUILT <br />L) HEADROOM MAINTENANCE: IF MOUNTING HEIGHTS <br />DOCUMENTS. <br />OR OTHER LOCATION CRITERIA ARE NOT <br />INDICATED, ARRANGE AND INSTALL COMPONENTS <br />J. TRANSFORMERS: <br />AND EQUIPMENT TO PROVIDE MAXIMUM POSSIBLE <br />1. TAPS FOR TRANSFORMERS 25 KVA AND LARGER: <br />HEADROOM. <br />TWO 2.5 PERCENT TAPS ABOVE AND TWO 2.5 <br />M)EQUIPMENT: INSTALL TO FACILITATE SERVICE, <br />PERCENT TAPS BELOW NORMAL FULL CAPACITY. <br />MAINTENANCE AND REPAIR OR REPLACEMENT OF <br />2. INSULATION CLASS: 220 DEG. E. <br />COMPONENTS OF BOTH ELECTRICAL EQUIPMENT <br />UL-COMPONENT--RECOGNIZED INSULATION <br />AND OTHER NEARBY INSTALLATIONS. CONNECT IN <br />SYSTEM WITH A MAXIMUM OF 115 DEG. C. RISE <br />SUCH A WAY AS TO FACILITATE FUTURE <br />ABOVE 40 DEG. C. AMBIENT TEMPERATURE. <br />DISCONNECTING WITH MINIMUM INTERFERENCE <br />WITH OTHER ITEMS IN THE VICINITY. <br />3. ENERGY EFFICIENCY FOR TRANSFORMERS RATED <br />15 KVA AND LARGER: <br />N) RIGHT OF WAY: GIVE TO PIPING SYSTEMS <br />INSTALLED AT A REQUIRED SLOPE. <br />A)COMPLYING WITH NEMA TP 1, CLASS 1 <br />EFFICIENCY LEVELS. <br />0)FIRE RATED ASSEMBLIES: INSTALL SLEEVES FOR <br />PENETRATIONS OF FIRE -RATED FLOOR AND WALL <br />ASSEMBLIES UNLESS OPENINGS COMPATIBLE WITH <br />FIRESTOP SYSTEM USED ARE FABRICATED DURING <br />CONSTRUCTION OF FLOOR OR WALL. <br />P)EXTEND SLEEVES INSTALLED IN FLOORS 2 <br />INCHES ABOVE FINISHED FLOOR LEVEL. <br />Q)SIZE PIPE SLEEVES TO PROVIDE 1/4" ANNULAR <br />CLEAR SPACE BETWEEN SLEEVE AND RACEWAY <br />OR CABLE, UNLESS INDICATED OTHERWISE. <br />2. FIRESTOPPING <br />A) APPLY FIRESTOPPING TO PENETRATIONS OF FIRE <br />RATED FLOOR AND WALL ASSEMBLIES FOR <br />ELECTRICAL INSTALLATIONS TO RESTORE ORIGINAL <br />FIRE RESISTANCE RATING OF ASSEMBLY. <br />3. CLEANING: <br />A) BRUSH AND CLEAN WORK PRIOR TO CONCEALING, <br />PAINTING AND ACCEPTANCE. <br />B) U-BOLTS: AT EACH FLOOR LEVEL OF RISER <br />RACEWAYS AND CONNECTED TO ACCEPTABLE <br />SUPPORTS. <br />C)RISER CLAMPS: AT EACH FLOOR LEVEL OR <br />RISER RACEWAYS AND RESTING ON SLAB. <br />D) SPACING: <br />1) MINIMUM 10 FEET ON CENTERS FOR METALLIC <br />RACEWAYS AND AS REQUIRED FOR <br />NON-METALLIC RACEWAYS, INCLUDING CABLE <br />TRAYS. <br />2) 5 FEET ON CENTER FOR WIREWAYS. <br />3)PER CODE AND AS NOTED FOR OTHERS. <br />E) MOUNT SUPPORTS TO STRUCTURE WITH: <br />1) TOGGLE BOLTS ON HOLLOW MASONRY. <br />2)EXPANSION SHIELDS OR INSERTS IN CONCRETE <br />AND BRICK. <br />3)MACHINE SCREWS ON METAL. <br />4)BEAM CLAMPS ON FRAMEWORK. <br />5)WOOD SCREWS ON WOOD. <br />6) PAN THROUGH STRAPS IN METAL DECK. <br />7)NAILS, RAWL PLUGS OR WORK PLUGS NOT <br />PERMITTED. <br />8) WHERE REQUIRED BY STRUCTURE, THROUGH <br />BOLTS AND FISH PLATES. <br />4. RACEWAYS AND BOXES: <br />A) EXPOSED: RUN PARALLEL WITH OR AT RIGHT <br />ANGLES TO WALLS. <br />B)CLEARANCE FROM WATER, STEAM OR OTHER <br />PIPING: MINIMUM 3" SEPARATION FROM STEAM <br />AND HOT WATER PIPES, EXCEPT 1" FROM PIPE <br />COVER AT CROSSINGS. <br />C)PROVIDE SEPARATE COPPER WIRE GROUNDING <br />CONDUCTOR FOR INTERRUPTED METALLIC <br />RACEWAYS, IN FLEXIBLE CONDUIT, FOR FEEDERS <br />AND MOTOR TERMINAL CONNECTIONS. <br />D)EMPTY RACEWAYS OVER 10 FEET LONG: <br />PROVIDE FISH OR PULL WIRE, GALVANIZED OR <br />NYLON ROPE. <br />E) EMT: <br />1) FEEDERS AND BRANCH CIRCUITS <br />2) DRY LOCATIONS, DRY WALLS, HUNG CEILINGS, <br />HOLLOW BLOCK WALLS AND FURRED SPACES. <br />F) FLEXIBLE STEEL CONDUIT: <br />1) FOR SHORT CONNECTIONS WHERE RIGID <br />CONDUIT IS IMPRACTICAL (MAXIMUM OF 3 <br />FEET). <br />2)FROM OUTLET BOX TO RECESSED LIGHTING <br />FIXTURE: MINIMUM 4 FEET, MAXIMUM 6 FEET <br />LENGTH. <br />3)FOR FINAL CONNECTION TO MOTOR TERMINAL <br />BOX, TRANSFORMERS AND OTHER VIBRATING <br />EQUIPMENT, WITH POLYVINYL SHEATHING AND <br />GROUND CONDUCTOR, EXCEPT PVC COATING <br />SHALL NOT BE PROVIDED IN AIR HANDLING <br />SPACES. MINIMUM LENGTH 18" WITH SLACK. <br />CONNECT GROUND CONDUCTOR TO ENCLOSURE <br />OR RACEWAY AT EACH END. <br />4)FOR EXPANSION JOINT CROSSINGS, CROSS AT <br />RIGHT ANGLES AND ANCHOR ENDS. <br />5) USE ONLY IN DRY LOCATIONS, DRY WALLS, <br />SUSPENDED CEILINGS AND FURRED SPACES. <br />6) PROVIDE LIQUIDTIGHT FLEXIBLE STEEL CONDUIT <br />OUTDOORS AND IN NON -WEATHER TIGHT <br />ENCLOSURES. <br />G)EXPANSION FITTINGS: AT RIGHT ANGLES WITH <br />SLIP JOINT CENTERED IN EXPANSION JOINT. <br />PROVIDE ON LENGTH OF RUNS IN ACCORDANCE <br />WITH MANUFACTURER'S RECOMMENDATIONS. <br />PRESET TO ALLOW FOR TEMPERATURE VARIATION. <br />H)RACEWAYS PASSING THROUGH FLOORS OR WALLS: <br />SEAL TO ORIGINAL OR SPECIFIED FIRE RATING <br />THROUGH FIRE -RATED CONSTRUCTION. SEAL <br />OPENING WITH UL LISTED PENETRATION <br />ASSEMBLY. <br />1) RIGID STEEL OR IMC: REQUIRED FOR OUTSIDE <br />EXPOSED INSTALLATION. <br />J) PVC SCHEDULE 40: REQUIRED FOR DIRECTLY <br />BURIED INSTALLATION. <br />5. OUTLET BOXES: <br />A) SET BOXES SQUARE AND TRUE WITH BUILDING <br />FINISH. <br />B)SECURE TO BUILDING STRUCTURE BY ADJUSTABLE <br />STRAP IRONS OR GROUT IN WITH MASONRY. <br />C) VERIFY OUTLET LOCATIONS IN FINISHED SPACES <br />WITH ARCHITECTURAL DRAWINGS OF INTERIOR <br />DETAILS AND FINISHES. <br />6. JUNCTION AND PULL BOXES: <br />A) LOCATION: <br />1) CLEAR OF OTHER TRADES. <br />2) CONCEAL JUNCTION AND PULL BOXES IN <br />FINISHED SPACES. <br />3) MOUNT IN ACCESSIBLE LOCATIONS. <br />B) SUPPORT: FROM BUILDING STRUCTURE, <br />INDEPENDENT OF CONDUIT. PROVIDE <br />FLOOR -TO -CEILING CHANNELS FOR MOUNTING ON <br />DRY WALL AND LIGHTWEIGHT CONSTRUCTION. <br />C)OUTLET BOXES FOR FIXTURES RECESSED IN <br />HUNG CEILINGS: ACCESSIBLE THROUGH OPENING <br />CREATED BY REMOVAL OF FIXTURE. SECURE TO <br />BLACK IREN CEILING SUPPORT. <br />D) MOTOR TERMINAL BOXES: COORDINATE WITH <br />MOTOR BRANCH CIRCUIT AND WIRING. ADD BOX <br />VOLUME WHERE REQUIRED. <br />7. FIRE SEALANTS: PROVIDE UL <br />THROUGH -PENETRATION SYSTEM FOR RACEWAYS <br />AND WIRE PASSING THROUGH FLOOR, CEILING, <br />WALLS AND PARTITIONS. SEAL PENETRATIONS <br />EXISTING IN ELECTRICAL ROOM. SEAL SHALL <br />RESTORE THE HOUR RATING OF THE PENETRATED <br />ASSEMBLY. <br />B. WIRE AND CABLE: <br />1. 600 VOLT CABLE: <br />A) NOT MORE THAN THREE (3) LIGHTING OR <br />CONVENIENCE OUTLET CIRCUITS IN 1 CONDUIT <br />UNLESS OTHERWISE INDICATED. SEPARATE <br />RACEWAYS FOR CONDUCTORS OF 208Y/120. <br />B)480Y/277 VOLT SYSTEMS <br />C) COMMUNICATION CABLE IN PLENUMS SHALL BE <br />PLENUM RATED OR SHALL BE INSTALLED IN <br />METAL RACEWAY. <br />2. TESTS: <br />A) CONTINUITY AND INSULATION TESTS: <br />1) 600 VOLTS: MEGGER <br />2)100 PERCENT OF FEEDERS. <br />3)10 PERCENT OF BRANCH CIRCUITS. <br />B)PERFORM: <br />1) PRIOR TO CONNECTION OF EQUIPMENT. <br />2) IN PRESENCE OF AUTHORIZED <br />REPRESENTATIVES. <br />C) SUBMIT WRITTEN REPORT OF RESULTS. <br />D)CORRECT OR REPLACE CABLE TESTING BELOW <br />MANUFACTURER'S STANDARDS. <br />C. LIGHTING FIXTURES: <br />1. INSTALLATION OF LIGHTING FIXTURES: <br />A) RECESSED FIXTURES SHALL BE SUPPORTED WITH <br />12 GAUGE WIRE HANGERS, 2 PER FIXTURE, AT <br />DIAGONALLY OPPOSITE CORNERS. FIXTURES <br />SHALL BE ATTACHED TO CEILING GRID TO RESIST <br />HORIZONTAL FORCE EQUAL TO WEIGHT OF <br />FIXTURE. <br />B)PROVIDE FIXTURES AND/OR FIXTURE OUTLET <br />BOXES WITH HANGERS TO PROPERLY SUPPORT <br />FIXTURE WEIGHT. COORDINATE WITH GENERAL <br />CONTRACTOR TO PROVIDE ADDITIONAL CEILING <br />GRID SUPPORT WIRES TO SUPPORT FIXTURE <br />WEIGHT. <br />C)PROVIDE CHANNEL AND SUPPORT FOR RECESSED <br />LIGHTING FIXTURES IN PLASTER CEILINGS. <br />D)RECESSED FLUORESCENT TROFFERS SHALL BE <br />HELD IN PLACE BY CADDY 515 SERIES SUPPORT <br />CLIPS OR SIMILAR CLIPS FROM FIXTURE <br />MANUFACTURER. <br />E) RECESSED FIXTURES IN SUSPENDED CEILINGS <br />SHALL HAVE FINAL CONNECTIONS MADE WITH A <br />LENGTH OF FLEXIBLE METAL CONDUIT NOT IN <br />EXCESS OF 72" WITH THHN CONDUCTORS AND <br />GREEN GROUND WIRE. <br />F) INSTALL FLUSH MOUNTED FIXTURES PROPERLY TO <br />ELIMINATE LIGHT LEAKAGE BETWEEN FIXTURE <br />FRAME AND FINISHED SURFACE. <br />G)SUSPENDED FIXTURES SHALL BE SUPPORTED <br />FROM MOUNTING BRACKETS PROVIDED BY THE <br />MANUFACTURER FOR THE SPECIFIC CEILING TYPE <br />AND CONSTRUCTION. PROVIDE INDEPENDENT <br />SUPPORT WIRES FROM FIXTURE SUPPORT <br />BRACKET TO STRUCTURE. <br />H)MOUNT SUSPENDED FIXTURES IN ALIGNMENT WITH <br />ARCHITECTURAL ELEMENTS AS DIRECTED BY THE <br />ARCHITECT. <br />1) ENSURE SUSPENDED FIXTURES ARE MOUNTED <br />LEVEL AND PARALLEL WITH THE SPACE. <br />J) EXIT SIGNS AND SURFACE FIXTURES INSTALLED IN <br />GRID CEILINGS SHALL BE SUPPORTED AND FED <br />FROM CADDY 512 SERIES ELECTRICAL BOX <br />HANGERS, OR SIMILAR SUPPORT FROM FIXTURE <br />MANUFACTURER, WITH 12 GAUGE WIRE INSTALLED <br />FORM BOX TO STRUCTURE. <br />2. QUALITY CONTROL: <br />A)AT DATE OF SUBSTANTIAL COMPLETION, REPLACE <br />LAMPS WHICH ARE NOT WORKING AND LAMPS <br />WHICH ARE NOT OPERATING PROPERLY AS <br />JUDGED BY THE ENGINEER. <br />B) VERIFY PROPER ORIENTATION OF DIRECTIONAL <br />LIGHT FIXTURES PRIOR TO INSTALLATION. THESE <br />FIXTURES MAY INCLUDE, BUT ARE NOT LIMITED <br />TO WALL WASHERS AND ADJUSTABLE ACCENT <br />LIGHTING FIXTURES. WHERE ORIENTATION CAN <br />NOT BE ASCERTAINED FROM DRAWINGS OR <br />MANUFACTURER'S LITERATURE, REQUEST <br />CLARIFICATION IN WRITING FROM ENGINEER. <br />3. ADJUSTING AND CLEANING: <br />A) CLEAN LIGHTING FIXTURES OF HANDLING MARKS, <br />DUST, DIRT, CONSTRUCTION DEBRIS, ETC. THIS <br />SHALL INCLUDE LAMPS, LENSES, REFLECTORS <br />AND LOUVERS, IN ADDITION TO FINISHED <br />SURFACES. CLEANING AND TOUCH-UP WORK <br />SHALL BE PERFORMED IN ACCORDANCE WITH THE <br />FIXTURE MANUFACTURER'S RECOMMENDATIONS, <br />WITH PARTICULAR EFFORTS MAD TO AVOID <br />MARRING OR HAZING SPECULAR FINISHES. <br />DAMAGED FIXTURES OR COMPONENTS SHALL BE <br />REPLACED WITH NEW. <br />B) FIXTURES HAVING ADJUSTABLE AN SETTINGS <br />SHALL BE INITIALLY SET ACCORDING TO DRAWING <br />REQUIREMENTS AND/OR ENGINEER'S INSTRUCTION <br />PRIOR TO SUBSTANTIAL COMPLETION. PROVIDE <br />FINAL AIM ADJUSTMENT IN PRESENCE OF <br />TENANT'S REPRESENTATIVE PER ENGINEER'S <br />GUIDANCE. <br />D. LIGHTING CONTROLS: <br />1. ENGAGE A FACTORY AUTHORIZED SERVICE <br />REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE <br />PERSONNEL TO ADJUST AND MAINTAIN LIGHTING <br />CONTROLS. <br />2. ALL CONTROLS SHALL BE ADJUSTED AND SET FOR <br />PROPER PERFORMANCE. <br />E. FIRE ALARM SYSTEM <br />1. INSTALLATION: <br />A) THE CONTRACTOR SHALL NOTIFY THE ENGINEER <br />IN WRITING OF ANY FIELD INSPECTOR DIRECTIVES <br />PRIOR TO PROCEEDING. FAILURE TO NOTIFY THE <br />ENGINEER MAY RESULT IN FORFEIT OF CHANGE <br />ORDER COMPENSATION. <br />BALL DEVICE ADDRESSES SHALL BE PROGRAMMED <br />TO INDICATE DEVICE TYPE AND LOCATION. <br />C)EXISTING TO REMAIN AND NEW STROBES ARE TO <br />BE SYNCHRONIZED. <br />D) INSTALL PRODUCTS IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />E) INSTALL MANUAL PULL STATION WITH OPERATING <br />HANDLE 46" AFF. INSTALL AUDIBLE AND VISUAL <br />SIGNAL DEVICES 80" AFF TO BOTTOM OF DEVICE <br />LENS. <br />F) ALL WIRE SHALL BE INSTALLED IN %' EMT <br />CONDUIT. <br />1) FOR ALARM INITIATING CIRCUITS - #18 AWG <br />(MINIMUM) TWISTED, SHIELDED PAIR, STRANDED <br />PER NEC ARTICLE 760. <br />F) MOUNT END -OF -LINE DEVICE IN BOX WITH LAST <br />DEVICE OR SEPARATE BOX ADJACENT TO LAST <br />DEVICE IN CIRCUIT AS REQUIRED BY <br />MANUFACTURER. <br />G) AUTOMATIC DETECTOR INSTALLATION: CONFORM <br />TO NFPA 72 AND MANUFACTURER'S <br />INSTRUCTIONS. <br />H) JUNCTION BOXES SHALL BE SPRAY PAINTED RED. <br />1) CONTRACTOR SHALL PROVIDE A FRAMED <br />TYPEWRITTEN ADDRESS SCHEDULE WHICH <br />CLEARLY INDICATES DEVICES CONNECTED TO <br />EACH ALARM INITIATING DEVICE CIRCUIT AND <br />SIGNAL CIRCUIT AND HANG ADJACENT TO THE <br />FACP. <br />J) ALL CONDUITS SHALL CONTAIN #16 AWG <br />EQUIPMENT GROUND UNLESS MANUFACTURER <br />PROVIDES DOCUMENTATION TO THE ENGINEER <br />WHICH NEGATES THE NEED FOR THIS <br />CONDUCTOR. <br />2. FIELD QUALITY CONTROL: <br />A) TEST IN ACCORDANCE WITH NFPA 72 AND LOCAL <br />FIRE DEPARTMENT REQUIREMENTS. <br />BALL WORK SHALL BE PERFORMED BY A STATE <br />OF FLORIDA CERTIFIED ELECTRICAL CONTRACTOR <br />OR ALARM CONTRACTOR. <br />3. SUPERVISION AND TESTING: <br />A) THE INSTALLATION SHALL BE SUPERVISED BY AN <br />AUTHORIZED MANUFACTURER'S REPRESENTATIVE. <br />B) UPON COMPLETION, THE SYSTEM SHALL BE <br />TESTED IN ACCORDANCE WITH NFPA 72 IN THE <br />PRESENCE OF THE OWNER AND TENANT'S <br />REPRESENTATIVE, THE FIRE MARSHAL AND AN <br />AUTHORIZED MANUFACTURER'S REPRESENTATIVE. <br />C)MANUFACTURER'S AND CONTRACTOR'S <br />CERTIFICATION OF COMPLETE OPERABLE, AND <br />SUCCESSFULLY TESTED SYSTEM SHALL BE <br />FURNISHED TO THE OWNER. <br />D) INDICATE SATISFACTORY COMPLETION OF <br />REQUIRED TESTS AND INSPECTIONS. <br />F. LABELING: <br />1. LABEL ALL ELECTRICAL PANELS, TRANSFORMERS, <br />DISCONNECT SWITCHES AND OTHER EQUIPMENT. <br />2. MARK ALL J-BOXES AND CONDUIT RUN <br />TRANSITIONS AND AT A MINIMUM OF EVERY 50 <br />FEET, BUT AT LEAST ONCE PER RUN. CONFORM <br />TO CLIENT STANDARD FOR LABELING. <br />3. PROVIDE NEW OR REVISED TYPED PANEL CIRCUIT <br />CARDS FOR EXISTING AND NEW PANELS. <br />4. PROVIDE SIGN ON PANEL COVERS OR FRAMES <br />STATING REQUIREMENT TO MAINTAIN A DISTANCE FO <br />36" CLEAR OF EQUIPMENT, FURNITURE OR STORED <br />MATERIALS. LABEL PANELS IDENTIFYING THE <br />LOCATION THE PANEL IS FED FROM, CONVERSELY <br />LABEL FEED SOURCE IDENTIFYING WHERE PANEL IS <br />LOCATED. <br />5. ALL DISCONNECT SWITCHES ARE TO BE <br />PERMANENTLY LABELED INDENTIFYING WHAT IT <br />CONTROLS AND WHERE THE DEVICE IS LOCATED. <br />6. LABEL COMMUNICATION DEVICES WITH USER AND <br />FUNCTION AND LABEL ALL CONDUITS OR CABLE A <br />MINIMUM OF EVERY 20 FEET. <br />7. LABEL ALL RECEPTACLES WITH PANEL DESIGNATION <br />AND CIRCUIT NUMBER. LABEL SHALL BE CLEAR <br />MYLAR, P-TOUCH TYPE. <br />2017 -Humana <br />Zephyrhills Guidance <br />Center <br />7920 GALL BLVD. <br />ZEPHYRHILLS, FL <br />33541 <br />moo <br />S m.lu HENNESSY <br />GROUP <br />A member company of SH Group, Inc. <br />Syska Hennessy group, Inc <br />9000 Southside Blvd. <br />Building 100, 1st Floor <br />Jacksonville, FI 32256 <br />Tel: 904.525.8669 <br />www.syska.com <br />Florida C.O.A. #00001897 <br />JAY J. LANE FL# 71396 <br />1 ISSUE FOR CONSTRUCTION 4/18/18 <br />Delta Issue Description Date <br />Nr. <br />DECLARATIVE STATEMENT: TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH <br />THE APPLICABLE MINIMUM BUILDING CODES AND THE <br />APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY <br />THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER <br />533.70 AND CHAPTER 633, FLORIDA STATUTES. <br />Drawn: EF Check: JL Owner Approval: <br />Job No: HUM17390 <br />Scale: NONE <br />ELECTRICAL <br />Title: SPECIFICATIONS <br />Sheet: ■ <br />