REFERENCE SYMBOLS (NOT ALL USED) I ABBREVIATIONS I GENERAL NOTES <br />m <br />i <br />GENERAL <br />DUCTWORK <br />NORTH ARROW 19 R - H r 1 R-- 1 i, DIRECTION OF RISE FOR DUCT <br />}; <br />DETAIL IDENTIFICATION NUMBER I--��,� ♦ I --0 I ♦ DIRECTION OF DROP FOR DUCT <br />ID 18x12 <br />ID -"I 20x12 DUCT (FIRST FIGURE DENOTES VIEW SHOWN) <br />DRAWING ON WHICH DETAIL IS DRAWN <br />SECTION OR ELEVATION IDENTIFICATION RECTANGULAR OR SQUARE BRANCH CONNECTION <br />LETTER <br />M-7 DRAWING ON WHICH SECTION OR Z---® SUPPLY DUCT TURNING UP OR TOWARD <br />ELEVATION IS DRAWN <br />SECTION OR DETAIL IDENTIFICATION SUPPLY DUCT TURNING DOWN OR AWAY <br />LABEL <br />�m EXHAUST OR RETURN DUCT TURNING UP OR TOWARD <br />LIGHT LINE WEIGHT INDICATES EXISTING WORK ♦I _ i I EXHAUST OR RETURN DUCT TURNING DOWN OR AWAY <br />BOLD LINE WEIGHT INDICATES NEW WORK �Q ROUND DUCT TURNING UP OR TOWARD <br />r------------ DASHED LINES INDICATES WORK TO BE REMOVED <br />ROUND DUCT TURNING DOWN OR AWAY <br />EQUIPMENT ABBREVIATION (SEE ABBREVIATION L TIS) _ <br />2---()=0 <br />FLAT OVAL DUCT TURNING UP OR TOWARD <br />EQUIPMENT SCHEDULE NUMBER FLAT OVAL DUCT TURNING DOWN OR AWAY <br />MATCHLINE <br />r TURNING VANES (TV) <br />IU rr <br />REVISION <br />ODRAWING REFERENCE NOTE <br />® ACCESS DOORS (AD) <br />POINT OF NEW CONNECTION (POC) <br />AIR TERMINAL UNIT WITH IDENTITY MARK <br />POINT OF DISCONNECTION (POD) (SEE ABBREVIATION LIST) <br />300 SQUARE FACE SUPPLY DIFFUSER OR GRILLE <br />300 CFM SEE DIFFUSER SCHEDULE <br />RETURN, TRANSFER OR EXHAUST CEILING GRILLE <br />DAMPERS <br />RETURN, TRANSFER OR EXHAUST CEILING GRILLE <br />-BDD BACK DRAFT DAMPER <br />-0 ELECTRICAL DAMPER SUPPLY GRILLE <br />-� AUTOMATIC DAMPER (PNEUMATIC) <br />�--�-06 RETURN, TRANSFER OR EXHAUST GRILLE <br />MOTOR OPERATED DAMPER <br />VOLUME DAMPER (E) EXISTING EQUIPMENT <br />FD FIRE DAMPER AND ACCESS DOOR (VERTICAL) (D) DEMOLITION EQUIPMENT <br />-♦ FD FIRE DAMPER AND ACCESS DOOR (HORIZONTAL) (N) NEW WORK <br />-Q� FD/SD COMBINATION FIRE DAMPER/SMOKE DAMPER (R) RELOCATED, EXISTING EQUIPMENT <br />0 ROUND DUCT INDICATOR <br />® CARBON DIOXIDE SENSOR <br />DIFFUSERS <br />O THERMOSTAT (OR) TEMPERATURE SENSOR <br />® SUPPLY <br />® OCCUPANCY SENSOR <br />® SUPPLY WITH NECK <br />® SUPPLY WITH BLANKING PLATE VAV AND REHEAT COILS <br />® SUPPLY ROUND � <br />REHEAT COIL a4� VAV BOX W/ REHEAT COIL <br />® SUPPLY ROUND WITH BLANKING PLATE <br />z RETURN\EXHAUST VAV BOX PARALLEL FAN POWERED <br />VAV BOX W/ REHEAT <br />® RETURN\EXHAUST WITH NECK <br />RETURN\EXHAUST WITH BLANKING PLATE <br />FIRE PROTECTION SYMBOLS <br />0 RETURWEXHAUST ROUND <br />EXISTING SEMI -RECESSED PENDANT SPRINKLER <br />0 RETURN\EXHAUST ROUND WITH BLANKING PLATE <br />• NEW SENI-CONCEALED PENDANT SPRINKLER <br />® CD -A RECTANGULAR CEILING DIFFUSER (CD -A) <br />(400) WITH 400 CFM SUPPLY AIR <br />CLD A TYPE A CEILING DIFFUSER <br />® (400) 400 CFM. SUPPLY AIR <br />CLD-B TYPE B ROUND CEILING DIFFUSER <br />® (400) 400 CFM. SUPPLY AIR <br />0 13X)300 CFM <br />CR (CG) CEILING RE REGISTER (CEILING GRILLE) <br />A <br />AIR; COMPRESSED AIR, AMPS <br />ACC <br />AIR COOLED CONDENSER <br />AD <br />ACCESS DOOR; AIR DRYER <br />ADJ <br />ADJACENT; ADJUST; ADJUSTABLE; ADJUSTMENT <br />ADMIN <br />ADMINISTRATION <br />AFF <br />ABOVE FINISHED FLOOR <br />AHJ <br />AUTHORITY HAVING JURISDICTION <br />AHU <br />AIR HANDLING UNIT <br />AI <br />ANALOG INPUT <br />AMP <br />AMPERE <br />ANCH <br />ANCHOR <br />AO <br />ANALOG OUTPUT <br />AP <br />ACCESS PANEL; ANGLE POINT <br />APPROX <br />APPROXIMATELY <br />ARCH <br />ARCHITECT <br />ATM <br />ATMOSPHERE; ATMOSPHERIC <br />AUTO <br />AUTOMATIC <br />AVG <br />AVERAGE <br />AWS <br />AMERICAN WELDING SOCIETY <br />BAUD <br />BOTTOM ANGLE UPWARDS DISCHARGE <br />BDD <br />BACKDRAFT DAMPER <br />BHP <br />BRAKE HORSEPOWER; BOILER HORSEPOWER <br />BI <br />BACKWARDS INCLINED <br />BLDG <br />BUILDING <br />BMS <br />BUILDING MANAGEMENT SYSTEM <br />BOD <br />BOTTOM OF DUCT <br />BOP <br />BOTTOM OF PIPE <br />BOT <br />BOTTOM <br />BTU <br />BRITISH THERMAL UNIT <br />BTUH <br />BRITISH THERMAL UNITS PER HOUR <br />C TO C <br />CENTER TO CENTER <br />CC <br />COOLING COIL <br />CD <br />CEILING DIFFUSER <br />CENT <br />CENTRIFUGAL <br />CEWA <br />CRITICAL ENVIRONMENT WORK AUTHORIZATION <br />CFF <br />CAP FOR FUTURE <br />CFM <br />CUBIC FEET PER MINUTE <br />CG <br />CEILING GRILLE <br />CH <br />CABINET HEATER; CHANNEL; CHILLED <br />CHLR <br />CHILLER <br />CHW <br />CHILLED WATER <br />CHWS <br />CHILLED WATER SUPPLY <br />CHWR <br />CHILLED WATER RETURN <br />CI <br />CAST IRON <br />CIRC <br />CIRCULATING; CIRCULATOR <br />CKT <br />CIRCUIT <br />CLG <br />CEILING <br />CO <br />CLEANOUT;COMPANY <br />COL <br />COLUMN <br />COMPR <br />COMPRESSOR <br />CONC <br />CONCRETE <br />COND <br />CONDENSER <br />CONN <br />CONNECT; CONNECTED; CONNECTION <br />CONST <br />CONSTRUCTION <br />CONT <br />CONTINUOUS; CONTINUATION <br />CONTR <br />CONTRACTOR <br />COORD <br />COORDINATE <br />CORR <br />CORRIDOR <br />Cu <br />CUBIC; COPPER; CONDENSING UNIT <br />CV <br />CONVECTOR; CONSTANT VOLUME <br />CW <br />DOMESTIC COLD WATER <br />D <br />CONDENSATE DRAIN <br />DB <br />DRY BULB TEMPERATURE <br />DDC <br />DIRECT DIGITAL CONTROL <br />DEG <br />DEGREE <br />DET <br />DETAIL <br />DI <br />DIGITAL INPUT <br />DIA <br />DIAMETER <br />DIFF <br />DIFFERENTIAL; DIFFERENCE; DELTA <br />DIM <br />DIMENSION <br />DISCH <br />DISCHARGE <br />DIV <br />DIVISION <br />DMPR <br />DAMPER <br />DN <br />DOWN <br />DO <br />DAMPER OPERATOR; DIGITAL OUTPUT <br />DOM <br />DOMESTIC <br />DP <br />DRIP PAN DRAIN; DEPTH; DEEP <br />DPV <br />DIFFERENTIAL PRESSURE VALVE <br />DR <br />DRAIN; INDIRECT DRAIN; INDIRECT WASTE <br />DSD <br />DUCT SMOKE DETECTOR <br />DWG <br />DRAWING <br />E EAST <br />EA EACH; EXHAUST AIR <br />EAC ENVIRONMENTAL AIR CONDITIONER <br />EAT ENTERING AIR TEMPERATURE <br />EDB ENTERING DRY BULB (TEMP.) <br />EF EXHAUST FAN <br />EFF EFFICIENCY <br />EG EXHAUST GRILLE <br />EL ELEVATION <br />ELEC ELECTRICAL; ELECTRIC <br />ELIM ELIMINATOR <br />EMER EMERGENCY <br />ENT ENTERING <br />EP ELECTRIC PNEUMATIC <br />EQUIP EQUIPMENT <br />ET EXPANSION TANK <br />EWB ENTERING WET BULB (TEMP.) <br />EWT ENTERING WATER TEMPERATURE <br />EXH EXHAUST <br />EXIST EXISTING <br />EXP EXPANSION; EXPOSED; EXPLOSION PROOF <br />EXT EXTERNAL <br />F FAHRENHEIT; FEED; FILTER <br />F TO F FACE TO FACE <br />FA FACE AREA; FIRE ALARM <br />FBC FLORIDA BUILDING CODE <br />FMC FLORIDA MECHANICAL CODE <br />FC FORWARD CURVED <br />FCO FLOOR CLEAN OUT <br />FD FIRE DAMPER <br />FF FINAL FILTER <br />FLA FULL LOAD AMPS <br />FLEX FLEXIBLE <br />FLR FLOOR <br />FOB FLAT ON BOTTOM <br />FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR <br />FPM FEET PER MINUTE <br />FPS FEET PER SECOND <br />FT FEET; FOOT; FAN TERMINAL <br />FTG FOOTING <br />FTR FINNED TUBE RADIATION <br />FTU FAN TERMINAL UNIT <br />FUT FUTURE <br />FV FACE VELOCITY <br />GA <br />GAGE <br />GAL <br />GALLON <br />GALV <br />GALVANIZED <br />GENL <br />GENERAL <br />GPM <br />GALLONS PER MINUTE <br />GR <br />GRILLE; GRAINS <br />H HEIGHT; HIGH; HUMIDITY; HUMIDISTAT; HUMIDIFIER <br />HB HOSE BIBB <br />HC HEATING COIL <br />HORIZ HORIZONTAL <br />HP HORSEPOWER <br />HT HEIGHT <br />HVAC HEATING, VENTILATING AND AIR CONDITIONING <br />HX HEAT EXCHANGER <br />HYD HYDRAULIC <br />HZ HERTZ <br />ID INSIDE DIAMETER <br />IN INCH <br />KW KILOWATT <br />KWH KILOWATT HOUR <br />LAN LOCAL AREA NETWORK <br />LAT LEAVING AIR TEMPERATURE <br />LAV LAVATORY <br />LBS POUNDS <br />LD LINEAR DIFFUSER <br />LDB LEAVING DRY BULB (TEMP.) <br />LF LINEAL FOOT OR FEET <br />LWB LEAVING WET BULB (TEMP.) <br />LWT LEAVING WATER TEMPERATURE <br />MAX MAXIMUM <br />MBH THOUSAND BRITISH THERMAL UNITS PER HOUR <br />MCA MINIMUM CIRCUIT AMPS <br />MECH MECHANICAL <br />MER MECHANICAL EQUIPMENT ROOM <br />MIN MINIMUM; MINUTE <br />MISC MISCELLANEOUS <br />MOCP MAXIMUM OVER CURRENT PROTECTION <br />MOD MOTOR OPERATED DAMPER <br />MTD MOUNTED <br />MTG MOUNTING <br />N <br />NORTH <br />N/A <br />NOT APPLICABLE <br />NC <br />NORMALLY CLOSED; NOISE CRITERIA <br />NIC <br />NOT IN CONTRACT <br />NO <br />NORMALLY OPEN; NUMBER <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />OA OUTSIDE AIR <br />OC ON CENTER <br />OD OUTSIDE DIAMETER <br />ODP OPEN DRIPPROOF <br />% <br />PERCENT <br />P <br />PUMP, PRESSURE <br />PD <br />PRESSURE DROP; PUMP DISCHARGE <br />PLBG <br />PLUMBING <br />PNEU <br />PNEUMATIC <br />POC <br />POINT OF CONNECTION <br />PRELIM <br />PRELIMINARY <br />PRESS <br />PRESSURE <br />PSI <br />POUNDS PER SQUARE INCH <br />PSIG <br />POUNDS PER SQUARE INCH GAGE <br />QTY <br />QUANTITY <br />R <br />RISER; RADIUS <br />RA <br />RETURN AIR <br />RAID <br />RADIATOR; RADIUS <br />RECIP <br />RECIPROCATING <br />REFG <br />REFRIGERATION <br />REL <br />RELIEF <br />REQD <br />REQUIRED <br />RG <br />RETURN GRILLE <br />RH <br />RELATIVE HUMIDITY <br />RHC <br />REHEAT COIL <br />RM <br />ROOM <br />RND <br />ROUND <br />RPM <br />REVOLUTIONS PER MINUTE <br />S <br />SOUTH <br />SA <br />SUPPLY AIR; SOUND ATTENUATOR <br />SE <br />SOUTHEAST <br />SEC <br />SECOND <br />SECT <br />SECTION <br />SF <br />SUPPLY FAN <br />SFD <br />COMBINATION SMOKE -FIRE DAMPER <br />SG <br />SUPPLY GRILLE; SPECIFIC GRAVITY <br />SP <br />STATIC PRESSURE <br />SPEC <br />SPECIFICATION <br />SQ <br />SQUARE <br />SS <br />STAINLESS STEEL <br />STD <br />STANDARD <br />SUCT <br />SUCTION <br />SUP <br />SUPPLY <br />T <br />TIME, TEMPERATURE <br />TBD <br />TO BE DETERMINED <br />TE <br />TOP ELEVATION <br />TEMP <br />TEMPERATURE; TEMPORARY <br />TERM <br />TERMINAL <br />TH <br />TOTAL HEAD <br />TSTAT <br />THERMOSTAT <br />THRU <br />THROUGH <br />TO <br />TIMED OPEN <br />TOD <br />TOP OF DUCT <br />TONS <br />TONS OF REFRIGERATION <br />TOP <br />TOP OF PIPE <br />TV <br />TURNING VANES <br />TXV <br />THERMOSTATIC EXPANSION VALVE <br />TYP <br />TYPICAL <br />UBC <br />UNIFORM BUILDING CODE <br />UC <br />UNDER COUNTER; UNDERCUT <br />UFC <br />UNIFORM FIRE CODE <br />UG <br />UNDERGROUND <br />UH <br />UNIT HEATER <br />UMC <br />UNIFORM MECHANICAL CODE <br />LION <br />UNLESS OTHERWISE NOTED <br />UPC <br />UNIFORM PLUMBING CODE <br />UR <br />URINAL <br />V <br />VENT; VOLT <br />VA <br />VALVE; VOLT AMPERE <br />VAV <br />VARIABLE AIR VOLUME <br />VD <br />VOLUME DAMPER <br />VEL <br />VELOCITY; VERIFY EXACT LOCATION <br />VENT <br />VENTILATE; VENTILATION; VENTILATOR <br />VERT <br />VERTICAL <br />VP <br />VAPOR PROOF; VELOCITY PRESSURE <br />W/O <br />WITHOUT <br />WB <br />WET BULB TEMPERATURE <br />WG <br />WALL GRILLE; WATER GAGE <br />WMS <br />WIRE MESH SCREEN <br />MECHANICAL SHEET INDEX <br />SHEET DESCRIPTION <br />MFP-0.1 MECHANICAL AND FIRE PROTECTION COVER SHEET <br />MFP-1.0 MECHANICAL AND FIRE PROTECTION FLOOR PLANS <br />1. PROVIDE ALL APPROPRIATE LABOR, TOOLS, MATERIALS, FABRICATION, EQUIPMENT, SERVICES, TRAINING, SUPERVISION, AND INCIDENTALS AS REQUIRED TO REMOVE AND <br />REPLACE EXISTING MECHANICAL (HVAC) EQUIPMENT AND SYSTEMS COMPLETE; AS INDICATED AND SPECIFIED ON THE PROJECT DRAWINGS. ALL WORK SHALL CONFORM TO: <br />A. FLORIDA BUILDING CODE 6th EDITION - BUILDING <br />B. FLORIDA BUILDING CODE 6th EDITION - MECHANICAL <br />C. FLORIDA FIRE PREVENTION CODE - 6TH EDITION <br />D. FLORIDA BUILDING CODE 6th EDITION - ENERGY CONSERVATION <br />E. NATIONAL ELECTRICAL CODE <br />F. NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS AS FOLLOWS: <br />NFPA 13 - STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS <br />NFPA 70 - NATIONAL ELECTRIC CODE <br />NFPA 72 - NATIONAL FIRE ALARM CODE <br />NFPA 101 - LIFE SAFETY CODE <br />G. AUTHORITY HAVING JURISDICTION REQUIREMENTS <br />H. LATEST SMACNA STANDARDS <br />WHERE THE REQUIREMENTS BETWEEN THE DIFFERENT CRITERIA AND CODES ARE AT VARIANCE, THE MOST STRINGENT REQUIREMENTS SHALL APPLY. <br />2. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL APPROPRIATE AND NECESSARY PERMITS, FEES, TESTS, INSPECTIONS, LICENSES AND CERTIFICATES OF APPROVAL <br />REQUIRED IN CONNECTION WITH WORK UNDER THIS CONTRACT. THIS CONTRACTOR SHALL COMPLY WITH LOCAL LAWS, STATE LAWS, ORDINANCES, RULES AND <br />REGULATIONS. <br />3. BEFORE SUBMITTING BID, BECOME THOROUGHLY FAMILIAR WITH EXISTING CONDITIONS AND OF THE PRESENT INSTALLATIONS TO WHICH CONNECTIONS MUST BE MADE OR <br />WHICH MUST BE CHANGED OR ALTERED. THE INTENT OF THE WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED HEREIN, AND NO CONSIDERATION WILL BE GRANTED BY <br />REASON OF LACK OF FAMILIARITY ON THE PART OF THE CONTRACTOR WITH ACTUAL PHYSICAL CONDITIONS, REQUIREMENTS, AND PRACTICES AT THE SITE. <br />4. CONTRACTOR SHALL NOTE THE CRITICAL SPACE AVAILABLE ABOVE CEILINGS. PROVIDE TRANSITION PIECES AT CROSSOVERS, UNDER BEAMS, OVER/UNDER PIPES, AS <br />REQUIRED TO ACCOMMODATE DUCTS WITHIN SPACE AVAILABLE, PROVIDING EQUIVALENT DUCT SIZE TO THE SIZE SHOWN. COORDINATE CLOSELY WITH OTHER TRADES TO <br />REDUCE THE NECESSITY FOR TRANSITIONS TO A MINIMUM. NO ADDITIONAL COSTS WILL BE PAID FOR ANY REQUIRED TRANSITIONS OR OTHER SPECIAL CHANGE SHAPE <br />PIECES. WHERE CONNECTING FLEXIBLE DUCTWORK TO CEILING DIFFUSERS AND CEILING REGISTERS, SIZE OF FLEXIBLE DUCT SHALL BE SAME SIZE AS NECK OF CEILING <br />DIFFUSER OR CEILING REGISTER. <br />5. THE MECHANICAL WORK INCLUDES DEMOLITION OF PORTIONS OF THE EXISTING HVAC SYSTEM. REFER TO DRAWINGS FOR EXTENT. <br />6. PROVIDE TEST, ADJUSTMENT, AND BALANCE OF ALL EXISTING HVAC EQUIPMENT AND SYSTEMS AFTER ALL WORK HAS BEEN ACCOMPLISHED. TAB WORK PERFORMED FOR <br />WORK UNDER THIS CONTRACT, INCLUDING BUT NOT LIMITED TO SINGLE DUCT VAV, GRILLES, REGISTERS, AND DIFFUSERS. TAB WORK SHALL BE ACCOMPLISHED IN <br />ACCORDANCE WITH THE REQUIREMENTS OF "NEBB". PROVIDE THREE COPIES OF THE FINAL REPORT. <br />7. ALL MECHANICAL DUCTWORK, ETC., SHALL BE SUPPORTED AS INDICATED OR SPECIFIED. PROVIDE ALL SUPPORTS, CONNECTIONS, CONTROLS, AND ACCESSORIES WHETHER <br />OR NOT SPECIFICALLY CALLED OUT. ALL MECHANICAL EQUIPMENT, DUCTWORK PIPING, ETC., SHALL BE SUPPORTED AS INDICATED OR SPECIFIED. ADDITIONAL SUPPORTS <br />SHALL BE PROVIDED AS REQUIRED TO ENSURE A VIBRATION FREE INSTALLATION AND SHALL COMPLY WITH LOCAL BUILDING CODE. <br />8. DESIGN BASIS: THE MECHANICAL DRAWINGS AND PLANS ARE DIAGRAMMATIC AND ARE BASED ON THE MANUFACTURER AND MODEL NUMBER OF THE MECHANICAL <br />EQUIPMENT AND DEVICES AS SCHEDULED. THE DRAWINGS ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL DETAILS <br />NECESSARY FOR THE EQUIPMENT INSTALLATION. THE CONTRACTOR SHALL COORDINATE ALL HVAC EQUIPMENT AND NEW DUCTWORK WITH ALL OTHER NEW WORK, WITH <br />THE EXISTING CONDITIONS, AND WITH THE WORK OF OTHER TRADES. IF FIELD CONDITIONS DIFFER SIGNIFICANTLY FROM THOSE SHOWN ON THE DRAWINGS AND AFFECT THE <br />MECHANICAL WORK, INFORM THE ENGINEER IMMEDIATELY BEFORE PROCEEDING WITH THE WORK INVOLVED. <br />9. UPON COMPLETION OF THE WORK EACH DAY, THE CONTRACTOR SHALL CLEAN THE PREMISES AND REMOVE AND DISPOSE OF ALL DEBRIS ASSOCIATED WITH HIS WORK. THE <br />JOBSITE AND PROJECT WORK AREAS SHALL BE LEFT IN A CONDITION ACCEPTABLE TO THE OWNER. THE BUILDING IS TO REMAIN OCCUPIED DURING THE WORK EFFORT, <br />COORDINATE WITH OWNER FOR TIMES WORK CAN OCCUR. <br />10. PROVIDE ALL DUCT AND PIPING FITTINGS, OFFSETS, AND TRANSITIONS, AS REQUIRED FOR A COMPLETE INSTALLATION. ALL DUCTWORK SIZES SHOWN ARE CLEAR INSIDE <br />DIMENSIONS. <br />11. THE CONTRACTOR SHALL MAINTAIN A RECORD SET OF DRAWINGS ON THE PROJECT SITE AND SHALL MARK THIS SET TO MAKE RECORD OF ALL CHANGES MADE IN THE <br />INSTALLATION OF THE MECHANICAL SYSTEMS. THE CONTRACTOR SHALL PROVIDE A WRITTEN WARRANTY TO REPLACE ALL FAULTY MATERIALS AND/OR LABOR, AT NO <br />ADDITIONAL COST TO THE BUILDING OWNER, FOR A PERIOD OF ONE YEAR FROM DATE OF OWNER ACCEPTANCE. <br />12. DAMAGE TO OTHER WORK: REPAIR ANY DAMAGE CAUSED BY THIS SECTION TO WORK OF OTHER SECTIONS. DAMAGE TO FIREPROOFING: REPAIR ANY DAMAGED <br />FIREPROOFING CAUSED BY THIS SECTION TO INTEGRITY OF ORIGINAL CONSTRUCTION. INSULATION: FURNISH INSULATION FOR ALL EQUIPMENT AND DISTRIBUTION SYSTEM <br />THAT PERMIT HEAT LOSS OR GAIN OR WILL FORM CONDENSATION. REPLACE ANY DAMAGED OR REMOVED INSULATION ON EXISTING SYSTEMS, THE CONTRACTOR SHALL <br />SUBMIT AN ADD ALTERNATE PRICE FOR DUCTWORK INSULATION REPAIRS WITH HIS BID. <br />13. PROVIDE THE ENGINEER WITH SIX (6) COPIES OF SUBMITTALS FOR APPROVAL FOR ALL EQUIPMENT, SYSTEMS, PRODUCTS, AND DEVICES AS INDICATED HEREIN. SUBMIT <br />PRODUCT AND PERFORMANCE DATA FOR EQUIPMENT, CONTROLS, DEVICES, AND FOR EACH ITEM OF EQUIPMENT. PROVIDE TWO-LINE DUCTWORK SHOP DRAWINGS FOR ALL <br />HVAC DUCTWORK SYSTEMS. PROVIDE COMMISSIONING REPORT FOR AUTOMATIC CONTROLS FOR HVAC SYSTEMS. <br />14. ALL AUTOMATIC FIRE PROTECTION SPRINKLER WORK SHALL COMPLY WITH NFPA 13, NFPA 14, NFPA 101, LOCAL BUILDING CODES, ALL REQUIREMENTS OF THE LOCAL <br />AUTHORITY HAVING JURISDICTION. <br />15. PROVIDE FIRE WATCH PROCEDURES DURING ALL SHUT -DOWNS TO EXISTING FIRE SPRINKLER SYSTEMS AND FIRE WATER SERVICE. <br />16. CONTRACTOR SHALL PROVIDE SPRINKLER SYSTEM SHOP DRAWINGS ("WORKING DRAWINGS" AS DEFINED BY NFPA 13), AND HYDRAULIC CALCULATIONS FOR ALL SPRINKLER <br />SYSTEM MODIFICATIONS. SHOP DRAWINGS SHALL INCLUDE ALL ITEMS REQUIRED BY NFPA 13, AND PRODUCT DATA ON ALL MATERIALS AND COMPONENTS OF THE NEW <br />SPRINKLER SYSTEM(S). <br />17. NEW SPRINKLER AND MODIFIED ZONES SHALL HAVE A 10 PSI CUSHION BETWEEN THE AVAILABLE PRESSURE AND DESIGN PRESSURE AT THE DESIGN FLOW RATE. <br />18. A NEW MUNICIPAL WATER FLOW TEST SHALL BE OBTAINED ON THE EXISTING PUBLIC WATER MAIN AT THE PROJECT SITE, PRIOR TO PERFORMING HYDRAULIC CALCULATIONS. <br />SUBMIT ALL FLOW TEST DATA WITH SPRINKLER SHOP DRAWINGS. <br />19. PIPING, FITTINGS, AND JOINTING METHODS SHALL BE AS LISTED IN THE SCHEDULE ON THIS SHEET, NO EXCEPTIONS. <br />20. PROVIDE PIPE HANGERS, BRACING, AND ATTACHMENT METHODS, AS REQUIRED BY NFPA 13. <br />21. THE CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY FEES, PERMITS AND INSPECTIONS FOR APPLICABLE PORTIONS OF THE WORK. <br />22. MAINTAIN BUILDING FIRE INTEGRITY WITH PIPING PENETRATIONS BY PROVIDING METAL SLEEVES AND UL APPROVED FIRE SAFEING. <br />23. AFTER ALL WORK IS COMPLETE, SPRINKLER SHOP DRAWINGS FOR THE PROJECT SHALL BE MODIFIED, AS REQUIRED, TO REFLECT ALL NEW AND EXISTING CONDITIONS FOR <br />THE ENTIRE ZONE. SUBMIT FINAL "AS -BUILT" DRAWINGS TO THE ENGINEER IN ELECTRONIC FORMAT, AUTOCAD RELEASE 14 OR 2000. SUBMIT FINAL HYDRAULIC <br />CALCULATIONS WITH MODIFICATIONS MADE TO ADDRESS AS -BUILT CONDITIONS. <br />24. PROVIDE OPERATION AND MAINTENANCE MANUALS FOR ALL NEW SPRINKLER SYSTEM DEVICES INSTALLED. COMPLETE "CONTRACTOR'S MATERIAL AND TEST CERTIFICATES <br />FOR ABOVEGROUND PIPING", AND INCLUDE IN OPERATION AND MAINTENANCE MANUALS. <br />RENOVATION/DEMOLITION NOTES <br />1. THIS CONTRACTOR SHALL VISIT THE SITE AND ADJOINING AREAS AND EXAMINE THE EXISTING CONDITIONS TO BECOME FAMILIAR WITH THEM AND TO DETERMINE THE <br />DIFFICULTIES WHICH WILL AFFECT THE EXECUTION OF THE WORK OF THIS CONTRACT. THIS CONTRACTOR SHALL PERFORM THIS PRIOR TO THE SUBMISSION OF HIS PROPOSAL. <br />SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE AND LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR, <br />EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE. <br />2. THE DEMOLITION WORK SHALL INCLUDE, PROVIDING ALL MATERIALS, ALL NECESSARY EXTENSIONS, CONNECTIONS, CUTTING, REPAIRING, ADAPTING AND OTHER MECHANICAL <br />WORK REQUIRED, TOGETHER WITH ANY REQUIRED TEMPORARY CONNECTIONS TO MAINTAIN SERVICE PENDING THE COMPLETION OF THE PERMANENT WORK. NOTES AND <br />GRAPHIC REPRESENTATION SHALL NOT LIMIT THE EXTENT OF DEMOLITION REQUIRED. EXTENT OF DEMOLITION WORK SHALL BE COORDINATED WITH THE ARCHITECT AND <br />BUILDING MANAGEMENT. <br />3. COORDINATE ALL EQUIPMENT AND SYSTEM SHUT DOWNS AND DRAIN DOWNS WITH BUILDING MANAGEMENT AND PROVIDE A MINIMUM OF 48 HOUR NOTICE. <br />4. ALL MATERIALS AND EQUIPMENT REMOVED AS A RESULT OF DEMOLITION ACTIVITIES SHALL BE TAKEN FROM THE SITE AND DISPOSED OF IN ACCORDANCE WITH ALL APPLICABLE <br />LAWS AND ENVIRONMENTAL REGULATIONS. <br />5. REMOVE ALL EXISTING DUCT, AIR TERMINALS, AND EQUIPMENT, WHETHER SPECIFICALLY INDICATED OR NOT, AS REQUIRED DUE TO THE ARCHITECTURAL AND MECHANICAL <br />DEMOLITION WORK IN THE AREA TO BE RENOVATED. ALL EQUIPMENT THAT HAS BEEN REMOVED AND IS NOT REUSED SHALL BE RETURNED TO THE OWNER, OR DISPOSED OF AS <br />DIRECTED BY THE OWNER'S REPRESENTATIVE. <br />6. FIELD VERIFY EXISTING DUCTWORK AND MAKE ADJUSTMENTS AS NECESSARY TO THE DUCT SHOWN ON THE PLANS, AS REQUIRED BY FIELD CONDITIONS. <br />7. COORDINATE ALL DEMOLITION WORK WITH NEW REQUIREMENTS TO ASSURE THAT EXISTING EQUIPMENT, THAT IS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM IS NOT <br />REMOVED. <br />8. ALL EXISTING MECHANICAL EQUIPMENT, DUCT AND PIPING THAT INTERFERE WITH ANY NEW CONSTRUCTION SHALL BE RELOCATED OR RE-ROUTED AS REQUIRED TO CLEAR THE <br />NEW CONSTRUCTION. RECONNECT ALL EXISTING EQUIPMENT THAT ARE TO REMAIN AND NOT AFFECTED BY THE NEW CONSTRUCTION, TO THE NEWLY RELOCATED OR RE-ROUTED <br />SYSTEM TO ENSURE A SAFE AND OPERATIONAL SYSTEM. <br />9. DISCONNECT AND RECONNECT THE EXISTING MECHANICAL EQUIPMENT AS REQUIRED BY THE CONSTRUCTION MODIFICATIONS. <br />10. IF ANY SUPPLY, RETURN, OR OUTDOOR AIR DUCTWORK IS FOUND TO BE LEAKING, BLOWN OUT, OR HAS BROKEN INSULATION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br />REPAIR OR REPLACEMENT. THE CONTRACTOR SHALL SUBMIT AN ADD ALTERNATE PRICE FOR DUCTWORK REPAIRS WITH HIS BID. <br />11. CONTRACTOR SHALL PROVIDE TEMPORARY PROTECTION TO ANY EXPOSED OR UNCAPPED NEW OR EXISTING DUCTWORK OR PIPING TO REMAIN, TO MINIMIZE DUST <br />CONTAMINATION IN ANY AND ALL OF THE AIR AND WATER SYSTEMS. THIS SHALL INCLUDE BUT IS NOT LIMITED TO TEMPORARY FILTERS, CAPS, ENCLOSURES, ETC. <br />12. REMOVE OR RELOCATE ALL EXISTING FIRE PROTECTION EQUIPMENT AND SPRINKLERS, AS REQUIRED DUE TO THE ARCHITECTURAL AND MECHANICAL DEMOLITION WORK IN THE <br />AREA TO BE RENOVATED. ALL EQUIPMENT THAT HAS BEEN REMOVED AND IS NOT REUSED SHALL BE RETURNED TO THE OWNER, OR DISPOSED OF AS DIRECTED BY THE OWNER'S <br />REPRESENTATIVE. <br />13. PROVIDE CUTTING AND PATCHING AS REQUIRED, WHETHER OR NOT SPECIFICALLY INDICATED. VERIFY EXTEND OF NEW AND EXISTING PARTITIONS WITH ARCHITECTURAL <br />DRAWINGS. <br />14. FIELD VERIFY EXISTING SPRINKLER PIPING AND MAKE ADJUSTMENTS AS NECESSARY TO THE SPRINKLER PIPING SHOWN ON THE PLANS, AS REQUIRED BY FIELD CONDITIONS. <br />15. COORDINATE ALL DEMOLITION WORK WITH NEW REQUIREMENTS TO ASSURE THAT EXISTING EQUIPMENT THAT IS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM IS NOT <br />REMOVED. <br />16. ALL EXISTING FIRE PROTECTION SPRINKLERS AND PIPING THAT INTERFERE WITH ANY NEW CONSTRUCTION SHALL BE RELOCATED OR RE-ROUTED AS REQUIRED TO CLEAR THE <br />NEW CONSTRUCTION. RECONNECT ALL EXISTING EQUIPMENT THAT IS TO REMAIN AND NOT AFFECTED BY THE NEW CONSTRUCTION, TO THE NEWLY RELOCATED OR RE-ROUTED <br />SYSTEM TO ENSURE A SAFE AND OPERATIONAL SYSTEM. <br />17. DISCONNECT AND RECONNECT THE EXISTING FIRE PROTECTION EQUIPMENT AS REQUIRED BY THE CONSTRUCTION MODIFICATIONS. <br />2017 -Humana <br />Zephyrhills Guidance <br />Center <br />7920 GALL BLVD. <br />ZEPHYRHILLS, FL <br />33541 <br />SYSKA HEIVIVuSY <br />GROUP <br />A member company of SH Group, Inc. <br />Syska Hennessy group, Inc <br />9000 Southside Blvd. <br />Building 100, 1st Floor <br />Jacksonville, FI 32256 <br />Tel: 904.525.8669 <br />www-syska.com <br />Florida C.O.A. #00001897 <br />EVANGELOS STEFAS FIB# 75946 <br />1 ISSUE FOR CONSTRUCTION 4/18/18 <br />Delta Issue Description Date <br />Nr. <br />DECLARATIVE STATEMENT. TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH <br />THE APPLICABLE MINIMUM BUILDING CODES AND THE <br />APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY <br />THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER <br />533.70 AND CHAPTER 633, FLORIDA STATUTES. <br />Drawn: SEW Check: ES Owner Approval: <br />Job No: HUM17390 <br />Scale: NONE <br />MECHANICAL FIRE <br />PROTECTION <br />Tom: COVER SHEET <br />Sheet: ■ <br />