Laserfiche WebLink
GENERAL MECHANICAL <br />NOTES: <br />1. ALL EXISTING CONDITIONS SHOWN ARE DERIVED FROM BASE <br />BUILDING AS -BUILT DRAWINGS AND SHALL BE FIELD VERIFIED <br />PRIOR TO CONSTRUCTION AND BEFORE SUBMITTING A BID. <br />2. ALL DUCTWORK AND PIPING SHALL BE ROUTED IN A CONCEALED <br />MANNER, ABOVE CEILINGS, OR IN SOFFITS, EXCEPT AS NOTED <br />OTHERWISE ON THE DRAWINGS. ALL WORK SHALL BE <br />COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN PIPING <br />AND DUCTWORK, INCLUDING DIVIDED DUCTS AND TRANSITIONS <br />AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL <br />COST TO THE OWNER. <br />3. PROVIDE ACOUSTICAL DUCT LINING FOR TRANSFER DUCTWORK <br />4. ALL WORK SHALL COMPLY WITH BUILDING STANDARDS, <br />SPECIFICATIONS AND GUIDELINES. <br />(-i'-�M[ECHANICAL AND FIRE PROTECTION PLAN NEW WORK <br />SCALE: 1 /8" = 1'-0" <br />FIRE PROTECTION <br />GENERAL NOTES: <br />1. THE FIRE PROTECTION SYSTEM IS A CONTRACTOR DESIGN AND <br />BUILD RESPONSIBILITY. SPRINKLER HEADS SHOWN ARE FOR <br />SCOPE AND GENERAL PRICING. CONTRACTOR SHALL BE <br />RESPONSIBLE FOR FINAL SPRINKLER LAYOUT, COUNT AND CODE <br />COMPLIANCE. <br />2. DESIGN CRITERIA OFFICES, TRAINING ROOMS, AND <br />CONFERENCE ROOMS: THE WET PIPE SPRINKLER SYSTEM SHALL <br />BE HYDRAULICALLY DESIGNED FOR LIGHT HAZARD OCCUPANCY <br />WITH A DENSITY OF 0.10 GPM/SQ. FT. OVER THE MOST <br />HYDRAULICALLY REMOTE AREA OF 1500 SQ. FT. A TOTAL OF 100 <br />GPM SHALL BE ADDED TO SPRINKLER WATER DEMAND FOR <br />COMBINED HOSE ALLOWANCE. MAXIMUM COVERAGE PER <br />SPRINKLER SHALL BE 225 SQ. FT. <br />3. ALL WORK SHALL COMPLY WITH BUILDING STANDARDS, <br />SPECIFICATIONS AND GUIDELINES. <br />4. THIS BUILDING WILL REMAIN OCCUPIED DURING THIS <br />CONSTRUCTION EFFORT. CONTRACTOR SHALL COORDINATE <br />WITH CLIENT REGARDING TIMES WORK CAN OCCUR. <br />5. ANY DAMAGED CEILING TILE AND GRID SHALL BE REPLACED <br />WITH NEW TO MATCH EXISTING TYPE. <br />O KEY NOTES: <br />1. 24x24 PERFORATED EGGCRATE RETURN GRILLE WITH <br />22x22 NECK TO MATCH EXISTING. <br />2. 22x10, 26 GAUGE GALVANIZED SHEET METAL <br />TRANSFER DUCT WITH 1" ACOUSTIC LINING ABOVE <br />CEILING. <br />3. EXISTING ROOFTOP AIR CONDITIONING UNIT, <br />DUCTWORK AND DIFFUSERS TO REMAIN. <br />4. EXISTING SPRINKLER HEAD TO REMAIN. <br />5. NEW SEMI -RECESSED SPRINKLER HEAD TO MATCH <br />EXISTING. PROVIDE CONNECTION TO EXISTING FIRE <br />SPRINKLER PIPING ACCORDING TO NFPA-13 AND <br />MANUFACTURERS REQUIRED LENGTH. CONTRACTOR <br />TO CONFIRM EXACT LOCATION AND ROUTING IN FIELD. <br />6. RELOCATE EXISTING THERMOSTAT AS INDICATED TO <br />NEW POSITION CLOSER TO CORNER. COORDINATE <br />FINAL LOCATION WITH ARCHITECTURAL AND ALL <br />TRADES. <br />ARMOVER — <br />90" ELL <br />90' ELL <br />HANGER STRAPS <br />RISER NIPPLE <br />REFER TO PLANS <br />MECH TEE (TAP OFF <br />(D <br />TOP OF BRANCHLINE <br />12" Z <br />1" DUCT LINER, FLAT BLACK <br />OR MAIN) <br />U <br />o <br />a <br />DROP NIPPLE <br />12" <br />EXISTING <br />3" <br />/ <br />BRANCHLINE OR MAIN <br />1 <br />SCREWS W/ <br />I ' 4" MIN. <br />DUCT SEALER MIN. <br />REDUCING COUPLING <br />SEMI -RECESSED PENDENT <br />i <br />FIRE SPRINKLER <br />NOTES: <br />j <br />CEILING <br />1. MAXIMUM SPACING BETWEEN HANGER LOCATIONS SHALL BE 8'-0" PER PAIR. <br />\ % <br />2. STRAPS SHALL BE MINIMUM 1" X 22 GAUGE GALVANIZED STEEL. <br />3. REFER TO SMACNA DUCT MANUAL FOR ADDITIONAL REQUIREMENTS. CONTINUE <br />NOTE: <br />RECESSED COVER PLATE <br />DUCT INSULATION THROUGH HANGERS. <br />RETURN GRILLE, <br />ALL BRANCH LINES SHALL SEMI -RECESSED PENDENT <br />(TYPICAL) <br />BE FROM TOP OF <br />BRANCHLINE OR MAIN. <br />FULL LENGTH OF AIR DEVICE <br />NECK DIMENSION <br />SPRINKLER RETURN DETAIL <br />SCALE NONE 4 <br />DUCT HANGER DETAIL SNONECE <br />3 <br />TYPICAL TRANSFER DUCT DETAIL SCALE <br />2 <br />'. h .... <br />k. F <br />2017 - Humana <br />Zephyrhills Guidance <br />Center <br />7920 GALL B LVD. <br />ZEPHYRHILLS, FL <br />33541 <br />SYSKA HENNESSY <br />GROUP <br />A member company of SH Group, Inc. <br />Syska Hennessy group, Inc <br />9000 Southside Blvd. <br />Building 100, 1st Floor <br />Jacksonville, FI 32256 <br />Tel: 904.525.8669 <br />www.syska.com <br />Florida C.O.A. #00001897 <br />a <br />j a <br />�11 <br />'�BIIIIIIY� <br />EVANGELOS STEFAS FL# 75946 <br />1 ISSUE FOR CONSTRUCTION 4/18/18 <br />Delta Issue Description Date <br />N r. <br />DECLARATIVE STATEMENT: TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH <br />THE APPLICABLE MINIMUM BUILDING CODES AND THE <br />APPLICABLE FIRE —SAFETY STANDARDS AS DETERMINED BY <br />THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER <br />533.70 AND CHAPTER 633, FLORIDA STATUTES. <br />Drawn: SEW Check. ES Owner Approval: <br />Job No:HUM 17390 <br />Scale: AS NOTED <br />MECHANICAL AND <br />FIRE PROTECTION <br />Title: P LA N <br />MFP-1 <br />0 <br />Sheet: ■ <br />