Laserfiche WebLink
DOOR SCHEDULE <br />DOOR <br />FRAME <br />OPENING FIRE <br />NO. <br />ROOM NAME <br />WIDTH <br />HEIGHT <br />THICKNESS <br />HARDWARE GROUP <br />TYPE <br />CORE <br />MATERIAL <br />FINISH <br />TYPE <br />MATERIAL <br />FINISH <br />RATING <br />DOOR REMARKS <br />102A <br />FURNITURE <br />STORAGE <br />6- 0" <br />8'- 0" <br />1 3/4" <br />(none) <br />F <br />RELOCATE EXISTING <br />111A <br />OFFICE <br />3- 0" <br />8'- 0" <br />1 3/4" <br />(n(8ie) <br />FIG <br />MATCH TO EXISTING DOOR EX.05 <br />EX.01 <br />FURNITURE <br />STORAGE <br />3' - 0" <br />8' - 0" <br />1 3/4" <br />(n&e) <br />RG <br />EX.02 <br />CORRIDOR <br />3' - 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.03 <br />FURNITURE <br />STORAGE <br />6' - 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.04 <br />CORRIDOR <br />3- 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.05 <br />CONSULT ROOM <br />3- 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.06 <br />OFFICE <br />3' - 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.07 <br />OFFICE <br />3- 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.08 <br />OFFICE <br />3' - 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.09 <br />OFFICE <br />3' - 0" <br />8'- 0" <br />! 1 3/4" <br />(none) <br />F <br />EX,10 <br />STORAGE <br />3'- 0" <br />8'- 0" 1 3/4" <br />(none) <br />F <br />EX.11 <br />TOILET <br />3- 0" <br />8'- 0" 1 3/4" <br />(none) <br />F <br />EX.12 <br />TOILET <br />T - 0" <br />8' - 0" 1 3/4" <br />(none) <br />F <br />EX.13 <br />TOILET <br />3' - 0" <br />8' - 0" 1 3/4" <br />(none) <br />F <br />EX.14 <br />JANITOR <br />3' - 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX. 15 <br />BREAK/COPY ROOM <br />3' - 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.16 <br />CORRIDOR <br />3' - 0" <br />8'- 0" <br />1 3/4" <br />(none) <br />F <br />EX.17 <br />CORRIDOR <br />6' - 0" <br />8' - 0" <br />1 3/4" <br />(none) <br />F <br />EX.18 <br />3- 0" <br />8'- 0" <br />1 3/4" <br />(none) <br />F <br />MISCELLANEOUS ACCESSORIES - HUMANA ZEPHYRHILLS <br />EQUIPMENT <br />SCHEDULE <br />TAG <br />DESCRIPTION <br />MANUFACTURER <br />MODEL <br />DEPTH <br />HEIGHT <br />WIDTH <br />COLOR <br />COMMENTS <br />MA-1 <br />WALL MOUNTED <br />SOAP DISPENSER <br />GOJO <br />#2799-12EE000 <br />- <br />- <br />- <br />MA-2 <br />PAPER TOWEL <br />DISPENSER <br />BOBRICK <br />#B-4262 <br />4.875" <br />13.5" <br />10.8125" <br />SST <br />PLUMBING FIXTURES - HUMANA ZEPHYRHILLS <br />EQUIPMENT <br />SCHEDULE <br />TAG <br />DESCRIPTION <br />MANUFACTURER <br />MODEL <br />DEPTH <br />HEIGHT <br />WIDTH <br />COLOR <br />COMMENTS <br />PF-1 <br />SINK <br />ELKAY <br />GOURMET #GECR2521 <br />21.25" <br />5.375" <br />25" <br />SST <br />PF-2 <br />FAUCET <br />DELTA <br />#27C2923 <br />- <br />- <br />- <br />CHROME <br />APPLIANCES - HUMANA ZEPHYRHILLS <br />EQUIPMENT <br />SCHEDULE <br />TAG <br />DESCRIPTION <br />MANUFACTURER <br />MODEL <br />COLOR <br />DEPTH <br />HEIGHT <br />WIDTH <br />COMMENTS <br />AP-1 <br />COFFEE BREWER <br />BUNN <br />#CW15-APS / 23001.0062 <br />SST <br />- <br />- <br />PROVIDED BY OWNER <br />AP-4 <br />COFFEE <br />BUNN <br />#28696.0002 <br />SST <br />- <br />GENERAL <br />GENERAL <br />PROVIDED BY OWNER <br />THERMAL AIRPOT <br />CONTRAC <br />CONTRAC <br />TOR <br />TOR <br />AP-5 <br />UNDERCOUNTER <br />GE <br />#GME04GGK / GLK <br />SST <br />21.25" <br />33.875" <br />19.75" <br />PROVIDED BY CONTRACTOR <br />REFRIGERATOR <br />AP-6 <br />COUNTERTOP <br />BRIO <br />#CLBC3000U <br />BLACK <br />TBD <br />TBD <br />TBD <br />PROVIDED BY CONTRACTOR <br />WATER <br />DISPENSER I <br />BOTTLE FILLER <br />AP-7 <br />UNDERCOUNTER <br />SUMMIT <br />#BIM44GADA <br />SST <br />23.5" <br />32.38" <br />14.5" <br />PROVIDED BY CONTRACTOR <br />ICE MAKER <br />CARD READER -ACCESS CONTROL I DOOR &HARDWARE NOTES <br />ACCESS -CONTROLLED EGRESS DOORS, <br />THE ENTRANCE DOORS IN A MEANS OF EGRESS IN BUILDINGS WITH AN OCCUPANCY IN GROUP A, B, <br />1-2, M, R-1, R-2, AND ENTRANCE DOORS TO TENANT SPACES IN OCCUPANCIES IN GROUPS A, B, 1-2, <br />M, R-1 AND R-2 ARE PERMITTED TO BE EQUIPPED WITH AN APPROVED ENTRANCE AND EGRESS <br />ACCESS CONTROL SYSTEM, LISTED IN ACCORDANCE WITH UL 294, WHICH SHALL BE INSTALLED IN <br />ACCORDANCE WITH ALL OF THE FOLLOWING CRITERIA: <br />1. A SENSOR SHALL BE PROVIDED ON THE EGRESS SIDE ARRANGED TO DETECT AN OCCUPANT <br />APPROACHING THE DOORS. THE DOORS SHALL BE ARRANGED TO UNLOCK BY A SIGNAL FROM <br />OR LOSS OF POWER TO THE SENSOR. <br />2. LOSS OF POWER TO THAT PART OF THE ACCESS CONTROL SYSTEM WHICH LOCKS THE <br />DOORS SHALL AUTOMATICALLY UNLOCK THE DOORS. <br />3. THE DOORS SHALL BE ARRANGED TO UNLOCK FROM A MANUAL UNLOCKING DEVICE LOCATED <br />40 INCHES TO 48 INCHES (1016 MM TO 1219 MM) VERTICALLY ABOVE THE FLOOR AND <br />WITHIN 5 FEET (1524 MM) OF THE SECURED DOORS. READY ACCESS SHALL BE PROVIDED TO <br />THE MANUAL UNLOCKING DEVICE AND THE DEVICE SHALL BE CLEARLY IDENTIFIED BY A SIGN <br />THAT READS "PUSH TO EXIT". WHEN OPERATED, THE MANUAL UNLOCKING DEVICE SHALL <br />RESULT IN DIRECT INTERRUPTION OF POWER TO THE LOCK - INDEPENDENT OF THE ACCESS <br />CONTROL SYSTEM ELECTRONICS - AND THE DOORS SHALL REMAIN UNLOCKED FOR A <br />MINIMUM OF 30 SECONDS. <br />4. ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM, IF PROVIDED, SHALL AUTOMATICALLY <br />UNLOCK THE DOORS, AND THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM <br />SYSTEM HAS BEEN RESET. <br />5. ENTRANCE DOORS IN BUILDING WITH AN OCCUPANCY IN GROUP A, B, 1-2 OR M SHALL NOT BE <br />SECURED FROM THE EGRESS SIDE DURING PERIODS THAT THE BUILDING IS OPEN TO THE <br />GENERAL PUBLIC. <br />Uj <br />0 <br />w <br />U <br />N <br />LU <br />1.1 <br />Cn <br />DOOR TYPES <br />SCHEDULE SEE SCHEDULE <br />TYPE F <br />LL <br />i <br />TYPE FIG <br />1 1 /2" <br />C <br />AND[ <br />ALUM <br />Ff <br />SEE SCHEDULE_,, 1, SEE SCHEDULE <br />TYPE 1 TYPE 2 <br />2017 -Humana <br />Zephyrhills Guidance <br />Center <br />7920 GALL B LVD. <br />ZEPHYRHILLS, FL <br />33541 <br />GEORGE W. DE LA HOZ <br />FL LICENSE #AR0016664 <br />1. ALL (E) DOORS REQUIRING HARDWARE UPDATE/MODIFICATION: REPLACE DOOR AS REQUIRED TO <br />MATCH (E) WITH NEWLY PREPARED DOORS AS SCHEDULED FOR NEW WORK. G.C. TO BE <br />RESPONSIBLE TO MAINTAIN (E) UL-RATING OF DOOR AND FRAME ASSEMBLY AT RATED <br />LOCATIONS. <br />2. SEE DETAIL (-/--- ) FOR TYPICAL DOOR CLEARANCES. ALL HARDWARE SHALL BE UNLOCKED IN <br />THE DIRECTION OF EGRESS, REGARDLESS OF OTHER LOCK FUNCTIONS. <br />3. ALL 20 MIN. UL RATED DOORS AND FRAME ASSEMBLIES TO HAVE S-LABEL. <br />4. ALL RATED DOOR ASSEMBLIES SHALL BE U.L. AND NFPA APPROVED. <br />5. ALL DOORS AND FRAMES TO BE INSTALLED PLUMB, STRAIGHT AND TRUE. MAINTAIN ADEQUATE <br />TOLERANCES AND CLEARANCES SO THAT ALL DOORS FIT AS SPECIFIED AND SWING/SLIDE <br />PROPERLY. ANY DEVIATION FROM THIS WILL BE REJECTED BY OWNER AS UNACCEPTABLE AND 1 3 ISSUE FOR CONSTRUCTION 04.18.2018 <br />WILL BE REPLACED AT SUPPLIER'S AND INSTALLER'S SOLE COST. <br />6. PROVIDE ALL PARTS NECESSARY FOR PROPER OPERATION OF ALL DOORS. Delta Issue Description Date <br />7. MAXIMUM DOOR OPENING EFFORT OF 5 LBS. AT INTERIOR DOORS AND EXTERIOR DOORS, 15 LBS. Nr. <br />AT FIRE RATED DOORS. <br />8. ALL DOORS IN THE REQUIRED PATH OF EGRESS EQUIPPED WITH ELECTRONIC LOCKING DEVICES <br />SHALL HAVE THESE DEVICES RELEASE IN THE EVENT OF A FIRE ALARM ACTIVATION I N T E R I C� R <br />9. ALL DOORS ARE EQUIPPED WITH SINGLE -EFFORT, NON -GRASP HARDWARE (I.E., LEVER OR LOOP) <br />CENTERED BETWEEN 34" AND 44" ABOVE THE FLOOR. <br />10. ALL DOORS MUST BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY, SPECIAL ARCHITECTS, P.C. <br />KNOWLEDGE OR EFFORT. 1A <br />11. ALL GLAZING AND SIDELITES TO BE CLEAR TEMPERED GLASS, U.O.N. <br />12. ALL KEYED LOCKETS TO BE SUPPLIED WITH BUILDING STANDARD CYLINDER. <br />13. SUBMIT SHOP DRAWINGS FOR ALL DOORS, FRAMES, AND HARDWARE PRIOR TO FABRICATION. M I A M <br />14. FIRE RATED DOORS AND FRAMES TO HAVE APPROVED FIRE RETARDANT BACKING. CONTRACTOR <br />TO PROVIDE CERTIFICATION OF FIRE RETARDANT TREATMENT TO THE FIRE MARSHAL. <br />15. DOOR HEIGHTS GIVEN IN THE DOOR SCHEDULE DO NOT INCLUDE THE DOOR FRAME. <br />16. DO NOT UNDERCUT UL RATED DOORS, PROVIDE MINIMUM CLEARANCE ABOVE THRESHOLD OR 2100 PONCE DE LEON BLVD <br />ABOVE FINISHED FLOOR. SUITE 1 090 <br />17, SEE AN -SERIES SHEETS FOR ADDITIONAL NOTES AND ABBREVIATIONS. <br />18. CONTRACTOR TO PREP ALL DOORS AND FRAMES TO RECEIVE ELECTRIFIED HARDWARE AS CORAL GABLES, FLORIDA 33134 <br />REQUIRED FOR CARD READERS, INCLUDING CABLING, PROVIDING A RACEWAY FROM ELECTRIFIED TEL 786-405-0230 <br />HINGE TO POWER TRANSFER AND PROVIDING ALL HARDWARE INCLUDING ELECTRIFIED HINGES. <br />ALL CARD READER DEVICES ARE FAIL-SAFE UNLESS OTHERWISE NOTED. ALL DOORS SCHEDULED <br />TO RECEIVE CARD READERS PROVIDE FREE EGRESS AT ALL TIMES. CARD KEY ACCESS IS NEVER PROFESSIONAL SERVICES CS, PORATCENS DRAWINGS RK <br />INGS AND WRITTEN <br />REQUIRED TO EXIT/EGRESS OUT OF ANY AREA OF THE BUILDING, MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK <br />OF THE ARCHITECT, AND THE SAME MAY NOT BE DUPLICATED, USED, <br />19. AT PAINTED WOOD DOORS, PAINT DOOR AND FRAME TO MATCH ADJACENT WALL FINISH, U.O.N. OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. <br />20. PROVIDE THREE JAMB ANCHORS MINIMUM AT APPROXIMATE HINGE POINTS FOR DOORS UP TO <br />T-6" H MAX. AND ONE BASE ANCHOR WITH TWO POWER ACTUATED FASTENERS PER JAMB. <br />21. PROVIDE FRAME ROUGH OPENING DIMENSIONS AS RECOMMENDED BY FRAME MANUFACTURER. <br />22. PROVIDE STANDARD FRAME PROFILE THROAT DIMENSIONS COMPATIBLE WITH AND AS <br />DETERMINED BY SCHEDULED PARTITION TYPES. Drawn: TEAM Check: Checker Owner Approval: <br />23. PROVIDE STRAPS, ANCHORS AND FRAMING ACCESSORIES AS REQUIRED FOR AS -BUILT FIELD <br />CONDITIONS AS RECOMMENDED BY THE MANUFACTURER AND INDUSTRY STANDARDS. Job No:9900019.00 Scale: As indicated <br />24. DOOR FRAMES SHALL BE SECURED IN PLACE WITH TWO FULL HEIGHT STUDS PER JAMB MIN. <br />25. DOOR UNDERCUTS SHALL BE KEPT TO A MINIMAL DIMENSION BASED ON FLOOR FINISH MATERIAL, <br />AND SHALL BE UNIFORM THROUGHOUT PROJECT, U.O.N. <br />26. THROUGH -BOLTING WILL NOT BE ACCEPTED. REINFORCE DOORS INTERNALLY. <br />27. ALL DOORS SHALL COMPLY WITH THE DOOR LANDING CLEARANCES FOR APPROACHES MEETING <br />MINIMUM ADA REQUIREMENTS. <br />28. SEQUENCE OF OPERATIONS FOR CARD READERS AT EXIT DOORS: <br />1. NORMAL BUSINESS HOURS: - DOORS OPEN WITH CARD READER, FREE EGRESS SCHEDULES <br />2. AFTER HOURS: - DOORS OPEN WITH CARD READER, FREE EGRESS Title: <br />3. FIRE ALARM: - FREE EGRESS <br />Sheet: ■ <br />a <br />