Laserfiche WebLink
N <br />CU:N=B5 <br />4SW- <br />I <br />Typical Sheet Notes <br />Foundation Plan <br />A. SEE SHEET "S3.01" FOR GENERAL STRUCTURAL NOTES, TYP. <br />B. COORDINATE w/ CIVIL DRAWINGS FOR CONTINUATION OF SIDEWALK, TYP. <br />C. "MF-#" INDICATES REINFORCED CONCRETE SPREAD FOOTING. REFER TO 119/S3.02" FOR <br />CONCRETE FOOTING SCHEDULE, TYP. <br />D. "TE-#" & "TS-#" INDICATES CONTINUOUS REINFORCED CONCRETE FOUNDATION. <br />REFER TO "9/S3.02" FOR CONCRETE FOOTING SCHEDULE, TYP. <br />E. EXTERIOR WALL SHEATHING TO BE 7/6" CDX PLYWOOD or O.S.B. (PROVIDE 1%z' P.T. <br />PLYWOOD @ 1st 48" ABOVE SLAB) FASTENED TO WOOD FRAMING w/ 8d RING SHANK <br />NAILS @ 6" O.C. ALONG PANEL EDGES & 12" O.C. IN FIELD, TYP. <br />F. "SW-#" INDICATES WOOD STUD SHEAR WALL. REFER TO SHEET "S4.04.2" FOR 4-STORY <br />SHEAR WALL SCHEDULE & DETAILS, TYP. <br />G. REFER TO SHEETS "S4.04.3" TO "S4.04.4" FOR TYPICAL WOOD WALL FRAMING <br />ELEVATIONS w/ STRAPPING & ANCHORAGES, TYP. <br />H. ALL MASONRY WALLS TO BE 8" CMU (fm = 1,500 PSI) w/ 9 GA. HORIZ, LADDER REINF. <br />@ 16" Q.C. & HAVE #5 VERTICAL BAR @ 32" O.C. IN SOLID GROUTED CELL, TYP. <br />PROVIDE DOWEL w/ STD. 900 HOOK INTO FOOTING & LAP w/ VERTICAL REINF. 48 BAR <br />O's, TYP. SEE SHEET "S3.05" FOR TYPICAL MASONRY DETAILS. <br />CONTRACTOR NOTE: <br />THRESHOLD BUILDING INSPECTIONS ARE CONSIDERED ADDITIONAL INSPECTIONS TO THE <br />INSPECTIONS REQUIRED ON THE BUILDING PERMIT. THE CONTRACTOR SHALL BE <br />REQUIRED TO SCHEDULE REGULAR INSPECTIONS THROUGH THE LOCAL <br />BUILDING INSPECTION DEPARTMENT. SEESHEET S3.01A FORTHRESHOLD <br />INSPECTION PLAN. <br />Key <br />Notes <br />Foundation Plan (4 Story Building) <br />1. <br />TOP OF SLAB ELEVATION = U-0", TYP. (U.N.O.) <br />8. EXTERIOR LOAD -BEARING STUD WALLS @ 1st FLOOR: <br />PROVIDE 2x6 VERTICAL STUDS @ 12" O.C. w/ 2x6 SOLID BLOCKING @ 5-0" (MAX.) <br />2. <br />CONCRETE SLAB -ON -GRADE: 4" THICK (MIN.) 3,000 PSI CONCRETE SLAB ON GRADE <br />PROVIDE CONT. DBL. 2x6 TOP PLATE & CONT. 2x6 P.T. BOTTOM PLATE FASTENED TO <br />w/ 6x6-W1.4xW1.4 W.W.F. @ MID -DEPTH OF SLAB ON 6 MIL. (MIN.) VAPOR BARRIER <br />CONCRETE SLAB w/ w/ SIMPSON "MASA" STRAPS SPACED @ 21" O.C., orY2"O A.B. (6" <br />OVER WELL COMPACTED SOIL, TYP. <br />MIN. EMBED.) SPACED @ 24" O.C., orY2"O SIMPSON "TITEN HD" ANCHORS (4" MIN. <br />EMBED) SPACED @ 21" O.C., TYP. <br />POST -TENSION FOUNDATION ALTERNATE: <br />GENERAL CONTRACTOR MAY PROVIDE MONOLITHIC POST -TENSION <br />9. INTERIOR LOAD -BEARING STUD WALLS @ 1st FLOOR: <br />FOUNDATION DESIGN ASA VALUE ENGINEERING ALTERNATE TO THE <br />PROVIDE DBL. 2x4 VERTICAL STUDS (FASTENED TOGETHER w/ 12d COMMON WIRE <br />CONVENTIONALLY REINFORCED FOUNDATION SHOWN. IF THIS ALTERNATE IS <br />NAILS @ 12" O.C. STAGGERED) SPACED @ 16" O.C. w/ 2x4 SOLID BLOCKING @ 5-0" <br />USED, THE CONTRACTOR MUST PROVIDE COMPLETE SHOP DRAWINGS & <br />O.C. (MAX.) PROVIDE CONT. DBL. 2x4 TOP PLATE & CONT. 2x4 P.T. BOTTOM PLATE <br />CALCULATIONS SIGNED & SEALED BY REGISTERED PROFESSIONAL ENGINEER IN THE <br />FASTENED TO CONCRETE SLAB w/12"O A307 ANCHOR BOLTS (6" EMBED.) @ 24" O.C. <br />STATE OF FLORIDA FOR REVIEW & APPROVAL BY THE ARCHITECT & STRUCTURAL <br />or w/ 0.157"0 HILTI "X-U" P.A.F.'s (lY2" EMBED.) @ 16" O.C., TYP. <br />ENGINEER. NOTE THAT REINFORCING STEEL FOR CURBS/ISLAND & SPREAD <br />FOOTINGS MAY NOT BE OMITTED OR REDUCED. <br />10. INTERIOR NON -BEARING STUD WALLS: <br />PROVIDE 2x VERTICAL STUDS @ 16" O.C. w/ CONT. 2x TOP PLATE & CONT. 2x P.T. <br />3. <br />SEE SLAB CONTROL PLAN IN ARCH. DWGS. FOR ALL DIMENSIONS, STEPS, SLOPES, <br />BOTTOM PLATE PER ARCH. DWGS, TYP. <br />DROPS, & DRAINS LOCATED IN FLOOR SLAB, TYP. <br />11. ALL STUD WALL SILL PLATES & OTHER WOOD MEMBERS IN CONTACT w/ CONCRETE <br />4. <br />PLUMBING FIXTURES: GENERAL PLUMBING FIXTURE LOCATIONS ARE INDICATED. <br />OR MASONRY SHALL BE PRESSURE TREATED, TYP. <br />REFER TO FLOOR PLANS AND VERIFY SPECIFIC FIXTURE LOCATIONS w/ ACTUAL <br />EQUIPMENT REQUIREMENTS. <br />12. STAIR FRAMING: PRE-ENGINEERED STEEL STAIRS w/ PRE -CAST CONCRETE TREADS. <br />SEE ARCH. DWGS. FOR REQUIRED LAYOUT & DIMENSIONS, TYP. SUBMIT COMPLETE <br />5. <br />CONTROL JOINTS (C.J.): PROVIDE SAWED CONTROL JOINTS ON SLAB SURFACE AS <br />SHOP DRAWINGS & CALCULATIONS SIGNED & SEALED BY A PROFESSIONAL ENGINEER <br />INDICATED ON PLANS. SEE CONTROL JOINT/ CONSTRUCTION JOINT DETAILS ON <br />REGISTERED IN THE STATE OF FLORIDA TO ARCH. & ENGINEER FOR REVIEW & <br />SHEET "S3.02.4", TYP. <br />APPROVAL. <br />6. <br />CORNER REINFORCEMENT: PROVIDE (2) #4 REINF. STEEL BARS x 4'-0" LONG @ 8" <br />13. LOAD -BEARING CMU WALLS @ 1st FLOOR ELEVATOR & STAIRS: PROVIDE 8" CMU <br />O.C. MID -DEPTH OF SLAB @ ALL RE-ENTRANT CORNERS, TYP. (U.N.O.) <br />STACKED IN RUNNING BOND w/ #5 VERT. REINF. IN SOLID GROUTED CELLS @ <br />CORNERS, ENDS, INTERSECTIONS, &SPACED @ 32" O.C. (MAX.) <br />7. <br />EXPANSION JOINTS: PROVIDE)/2" THICK x 4" WIDE CONTINUOUS BITUMINOUS <br />MATERIAL WHERE CONCRETE SLABS ABUT EACH OTHER, TYP. (U.N.O.) <br />14. GIRDER TRUSS SUPPORT: PROVIDE (4) 2x MULTI -STUD WOOD POST FASTENED w/ 12d <br />COMMON WIRE NAILS @ 12" O.C. STAGGERED EACH PLY UNDER BEARING POINTS OF <br />ALL PRE-ENGINEERED GIRDER TRUSSES TO FOUNDATION, TYP. (U.NO.) <br />CUNIT A2 UNIT Al C*f�:)CUNIT Al C(Nt�) C4NIT A3 C*�l) CUNIT A2 <br />1 <br />S3.11 <br />Building Type I -Foundation Plan <br />SCALE: Y8" = F-0" <br />v <br />. <br />ma�yy <br />:I <br />ro <br />v <br />o <br />E <br />v <br />L <br />+j <br />Z <br />+-J <br />�3 <br />U <br />C <br />ro <br />L <br />0 <br />U <br />U <br />ro <br />T <br />.0 <br />44 <br />ro <br />ro <br />U <br />0 <br />N <br />L <br />.0 <br />C <br />E <br />I- <br />Q) <br />4-1 <br />� <br />V <br />h <br />ro <br />0 <br />C <br />.0 <br />E <br />G <br />E <br />N <br />A <br />ro <br />V <br />it <br />ro <br />v <br />L <br />3 <br />a <br />0 <br />U <br />0 <br />L <br />a <br />c <br />4-1 <br />Vi <br />C' <br />0 <br />ro <br />U <br />4: <br />'u <br />a <br />C <br />ro <br />C <br />ro <br />n, <br />v <br />.0 <br />v <br />0 <br />V <br />L <br />v <br />C <br />b0 <br />W <br />C <br />00 <br />v <br />0 <br />v <br />S <br />t4. <br />0 <br />to <br />Q <br />J <br />} <br />m <br />,: FORUMN <br />CO <br />Lij <br />N ARCHITECTURE & <br />z INTERIOR DESIGN, INC. <br />PLANNING I ARCHIIIIECrURE I WTMMDESIGN <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />s 407.830.1400 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />City of Zephyrhills, FL <br />jjr f�/gr pp�,, <br />aFk� a <br />2965 WEST STATE ROAD 434, SUITE 100 . LONGWOOD, FL 32779 <br />TEL 407/682-2086 ■ FAX 407/682-2386 <br />WWW.SCD-ENG.COM <br />� ��p84�000VNd00 <br />76 <br />f ). TAT (OF <br />i .., _ <br />on <br />e t :Npq <br />R bert C. Scroggins, P.E. <br />FL Registration No. 56158 <br />This document has been electronically signed and sealed by Robert C, Scroggins, PE on the Date <br />and/or Time Stamp shown using a digital signature. Printed copies of this document are not <br />s considered signed and sealed and the signature must be verified on any electronic copies. <br />I <br />SET DISTRIBUTIONS: <br />12/16/2021 OWNER REVIEW SET <br />02/17/2022 PERMIT SET <br />'71 <br />0 SHEET REVISIONS: <br />EDITED BY: RCS, TLW <br />SC&D PROJECT NO. 21-020 <br />FORUM PROJECT NO. 4097 <br />11 <br />z <br />W Building Type I - <br />0 <br />Foundation Plan <br />W <br />z <br />cd <br />W <br />ry <br />U <br />W <br />U <br />a S3,11 <br />0 <br />ou <br />