Laserfiche WebLink
I <br />EXTERIOR SHEATHI <br />BUILDING WRAP <br />FIBER CEMENT LAP SIDING <br />SELF ADHERING FLASHING <br />FIBER CEMENT STARTER STRIP <br />METAL FLASHING <br />GAP, NO SEALANT <br />CONT SEALANT <br />INTERIOR SHEATHING <br />? / WOOD FRAMING PER <br />J STRUCTURAL DRAWINGS <br />/-CONT SEALANT <br />CV <br />SELF ADHERING FLASHING TO EXTEND-� II <br />2 PAST END OF FIBER CEMENT TRIM _ <br />CV <br />5l4 FIBER CEMENT TRIM � <br />GAP, NO SEALANT C <br />HEMMED METAL FLASHING <br />CONT SEALANT <br />CONT SEALANT AT ROUGH <br />OPENING TO DOOR FRAME <br />Door Head <br />at Fiber Cement Lap Siding <br />EXTERIOR SHEA <br />BUILDING <br />FIBER CEMENT LAP <br />SELF ADHERING FLASHING TO E, <br />2" PAST END OF FIBER CEMENT <br />CONT SE <br />5/4 FIBER CEMEN' <br />CONT SE, <br />CONT SEALANT AT F <br />OPENING TO DOOR I <br />BUILDING <br />TURNED INTO OP <br />Door Jamb <br />at Fiber Cement Lap Siding <br />SELECTED BY OWNER <br />CONT SEALANT <br />CONT SEALANT AT ROUGH <br />OPENING TO DOOR FRAME <br />SHIM AS NEEDED,1/4" MAX <br />DOOR & FRAME PER SCHEDULE <br />3" = 1'-0" <br />SHEATHING <br />AMING PER <br />RAIL DRAWINGS <br />kLANT <br />ELECTED BY OWNER <br />SLANT <br />kLANT AT ROUGH <br />TO DOOR FRAME <br />4EEDED,1/4" MAX <br />-RAMS PER SCHEDULE <br />3" = 1'-V„ <br />UNIT DOOR SCHEDULE SHEET NOTES <br />MARK <br />DESCRIPTION <br />DOOR <br />MATERIAL <br />HDW <br />NSF) <br />RATING <br />REMARKS <br />TYPE <br />SIZE <br />MATERIAL <br />INT/EXT <br />LOCATION <br />W <br />H <br />1 <br />EXT <br />UNIT ENTRY <br />2P <br />T-0" <br />T-0" <br />METAL <br />WOOD <br />A <br />21 <br />45 MIN <br />6 <br />2 <br />EXT <br />PATIO / BALCONY <br />FG <br />3'-0" <br />6'-8" <br />MTL /GLS <br />METAL <br />B <br />21 <br />- <br />1,3 <br />3 <br />INT <br />BEDROOM I BATH <br />2P <br />2'-10" <br />6'-8" <br />WOOD <br />WOOD <br />C <br />5 <br />4 <br />INT <br />CLOSET <br />2P <br />2'-10" <br />6'-8" <br />WOOD <br />WOOD <br />D <br />- <br />5 <br />5 <br />INT <br />CLOSET <br />2P <br />2'-0" <br />6'-8" <br />WOOD <br />WOOD <br />D <br />- <br />6 <br />INT <br />CLOSET <br />2P <br />2'-8" <br />6'-8" <br />WOOD <br />WOOD <br />D <br />- <br />7 <br />INT <br />MECH <br />2P <br />2'-8" <br />6'-8" <br />WOOD <br />WOOD <br />D <br />- <br />10 <br />8 <br />INT <br />LAUNDRY <br />2P <br />2(2'-6") <br />6'-8" <br />WOOD <br />WOOD <br />D <br />- <br />0 BUILDING DOOR SCHEDULE - BUILDING TYPE <br />MARK <br />DESCRIPTION <br />DOOR <br />FRAME <br />MATERIAL <br />HDW <br />AREA <br />(SF) <br />RATING <br />REMARKS <br />TYPE <br />SIZE <br />MATERIAL <br />INT/EX <br />T <br />LOCATION <br />W <br />H <br />1ST <br />101 <br />EXT <br />BUILDING ENTRANCE <br />FG <br />2(3'-0") <br />8'-0" <br />MTL/GLS <br />METAL <br />E <br />24 <br />45 MIN <br />1,7 <br />FLOOR <br />102 <br />EXT <br />SIDE ENTRY <br />FG <br />3'-0" <br />T-0" <br />MTL/GLS <br />METAL <br />F <br />21 <br />45 MIN <br />8,9 <br />103 <br />EXT <br />SIDE ENTRY <br />FG <br />3'-0" <br />T-0" <br />MTL/GLS <br />METAL <br />F <br />21 <br />45 MIN <br />8,9 <br />104 <br />EXT <br />STAIR (EXT) <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />J <br />21 <br />90 MIN <br />105 <br />EXT <br />STAIR (EXT) <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />J <br />21 <br />90 MIN <br />111 <br />INT <br />STAIR (INT) <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />112 <br />INT <br />STAIR (INT) <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />113 <br />INT <br />BOOSTER PUMP <br />F <br />2(3'-0") <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />20 MIN <br />7 <br />115 <br />INT <br />MECH <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />H <br />20 MIN <br />116 <br />INT <br />ELEC <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />G <br />45 MIN <br />2 <br />117 <br />INT <br />ELEC <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />45 MIN <br />2 <br />118 <br />INT <br />RISER <br />F <br />2(2'-6") <br />T-0" <br />METAL <br />METAL <br />H <br />- <br />45 MIN <br />7 <br />2ND <br />121 <br />INT <br />STAIRS <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />FLOOR <br />122 <br />INT <br />STAIRS <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />123 <br />INT <br />BUILDING SERVICES <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />20 MIN <br />125 <br />INT <br />MECH <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />H <br />- <br />20 MIN <br />3RD <br />131 <br />INT <br />STAIRS <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />FLOOR <br />132 <br />INT <br />STAIRS <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />133 <br />INT <br />BUILDING SERVICES <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />20 MIN <br />135 <br />INT <br />MECH <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />H <br />- <br />20 MIN <br />4TH <br />141 <br />INT <br />STAIRS <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />FLOOR <br />142 <br />INT <br />STAIRS <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />143 <br />INT <br />BUILDING SERVICES <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />20 MIN <br />145 <br />INT <br />ELEV CLOSET <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />I <br />- <br />20 MIN <br />146 <br />INT <br />MECH <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />H <br />- <br />20 MIN <br />0 BUILDING DOOR SCHEDULE - BUILDING TYPE II <br />MARK <br />DESCRIPTION <br />DOOR <br />FRAME <br />MATERIAL <br />HDW <br />AREA <br />(SF) <br />RATING <br />REMARKS <br />TYPE <br />SIZE <br />MATERIAL <br />INT/EX <br />T <br />LOCATION <br />W <br />H <br />1ST <br />201 <br />EXT <br />BUILDING ENTRANCE <br />FG <br />2(3'-0") <br />8'-0" <br />MTL / GLS <br />METAL <br />E <br />24 <br />45 MIN <br />1,7 <br />FLOOR <br />202 <br />EXT <br />SIDE ENTRY <br />FG <br />T-0" <br />T-0" <br />MTL/GLS <br />METAL <br />F <br />21 <br />45 MIN <br />8,9 <br />203 <br />EXT <br />SIDE ENTRY <br />FG <br />T-0" <br />T-0" <br />MTL I GLS <br />METAL <br />F <br />21 <br />45 MIN <br />8,9 <br />204 <br />EXT <br />STAIR (EXT) <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />J <br />21 <br />90 MIN <br />205 <br />EXT <br />STAIR (EXT) <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />J <br />21 <br />90 MIN <br />211 <br />INT <br />STAIR (INT) <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />212 <br />INT <br />STAIR (INT) <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />213 <br />INT <br />BOOSTER PUMP <br />F <br />2(3'-0") <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />20 MIN <br />7, 10 <br />215 <br />INT <br />MECH <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />H <br />- <br />20 MIN <br />216 <br />INT <br />ELEC <br />F <br />314" <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />45 MIN <br />217 <br />INT <br />ELEC <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />45 MIN <br />218 <br />INT <br />RISER <br />F <br />2(2'-6") <br />T-0" <br />METAL <br />METAL <br />H <br />- <br />45 MIN <br />7 <br />2ND <br />221 <br />INT <br />STAIRS <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />FLOOR <br />222 <br />INT <br />STAIRS <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />223 <br />INT <br />BUILDING SERVICES <br />F <br />3'-0" <br />7'-0" <br />METAL <br />METAL <br />G <br />- <br />20 MIN <br />225 <br />INT <br />MECH <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />H <br />- <br />20 MIN <br />3RD <br />231 <br />INT <br />STAIRS <br />F <br />3'-0" <br />7'-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />FLOOR <br />232 <br />INT <br />STAIRS <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />233 <br />INT <br />BUILDING SERVICES <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />20 MIN <br />235 <br />INT <br />MECH <br />F <br />3'-0" <br />7'-0" <br />METAL <br />METAL <br />H <br />- <br />20 MIN <br />4TH <br />241 <br />INT <br />STAIRS <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />FLOOR <br />242 <br />INT <br />STAIRS <br />F <br />T-0" <br />7'-0" <br />METAL <br />METAL <br />K <br />- <br />90 MIN <br />243 <br />INT <br />BUILDING SERVICES <br />F <br />3'-0" <br />T-0" <br />METAL <br />METAL <br />G <br />- <br />20 MIN <br />245 <br />INT <br />ELEV CLOSET <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />I <br />- <br />20 MIN <br />246 <br />INT <br />MECH <br />F <br />T-0" <br />T-0" <br />METAL <br />METAL <br />H <br />- <br />20 MIN <br />A TYPICAL DETAILS ILLUSTRATE ASSEMBLY OF MATERIALS TO ACHIEVE <br />DESIGN INTENT AND MAINTAIN FIRE RATINGS AND WEATHER/AIR <br />BARRIER REQUIREMENTS AS NECESSARY. CONTRACTOR IS <br />RESPONSIBLE FOR VERIFYING CONSTRUCTION ASSEMBLIES ALONG <br />WITH STRUCTURAL AND ARCHITECTURAL PLANS TO DETERMINE ACTUAL <br />DOOR FRAME THICKNESS REQUIRED IN ALL CONDITIONS <br />B MATERIALS, TYPES, STYLES, SIZES, AND FINISHES FOR DOORS TO BE AS <br />INDICATED ON THE DRAWINGS AND AS SPECIFIED, UNLESS OTHERWISE <br />DIRECTED BY THE OWNER AND APPROVED BY THE ARCHITECT. INSTALL <br />WORK PLUMB, RIGID, PROPERLY ALIGNED, AND SECURELY FASTENED IN <br />PLACE. COMPLY WITH DRAWINGS, MANUFACTURER'S WRITTEN <br />INSTRUCTIONS, AND ALL APPLICABLE CODES. <br />C ALL EXTERIOR DOORS SHALL BE SEALED AND WEATHER STRIPPED. <br />EXTERIOR DOORS SHALL COMPLY WITH THE STATE'S ENERGY CODE OR <br />OTHER APPLICABLE STANDARD. <br />1 <br />D IF REQUIRED BY NOTE ON A1.02, EXTERIOR DOORS AND FRAMES SHALL <br />BE IMPACT RATED AND COMPLY WITH APPLICABLE CODE AND THE AHJ. <br />E ALL FIRE -RATED DOOR ASSEMBLIES SHALL BE INSTALLED ACCORDING <br />TO NFPA 80 AND DISPLAY REQUIRED LABELS PER CODE. <br />F GLAZING IN DOORS, ADJACENT TO DOORS, OR OTHER HAZARDOUS <br />LOCATIONS AS DEFINED BY THE BUILDING CODE, SHALL COMPLY WITH <br />SAFETY GLAZING REQUIREMENTS PER THE BUILDING CODE AND CPSC 16 <br />CFR 1201 OR ANSI Z97.1 AS APPROPRIATE. <br />G DOORS AND HARDWARE SHALL MEET ALL FEDERAL, STATE, AND LOCAL <br />REQUIREMENTS FOR ACCESSIBILITY, WHERE APPLICABLE, INCLUDING <br />THE FORCE REQUIRED TO OPERATE THE DOORS AND HARDWARE, <br />THRESHOLD REQUIREMENTS, AND CLOSING SPEED FOR SELF -CLOSING <br />DOORS. <br />H HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE <br />NON -REMOVABLE PINS AND NON -EXPOSED SCREWS. <br />J FRONT MAIN ENTRANCE DOOR FOR RESIDENTIAL DWELLING UNITS <br />SHALL HAVE DOOR VIEWER(S); TYPICAL ONE VIEWER PER DOOR <br />AT 60" AFF, EXCEPT FOR UNITS REQUIRED TO PROVIDE TWO VIEWERS <br />PER DOOR, ONE AT 60" AFF AND ONE AT 43" AFF MAXIMUM, UNO. <br />K COORDINATE DOORS THAT REQUIRE ELECTRIFIED DOOR HARDWARE <br />WITH CONNECTIONS TO POWER SUPPLIES AND WITH BUILDING SAFETY <br />AND SECURITY SYSTEMS. <br />�L THE KEYING SYSTEM TO BE AS INDICATED IN THE SPECIFICATIONS, OR <br />i AS SPECIFIED BY THE OWNER. <br />M ALL SWINGING DOOR AND GATES LOCATED WITHIN AN ACCESSIBLE <br />ROUTE SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE WITHIN 10" <br />OF THE FINISHED FLOOR OR GROUND MEASURED VERTICALLY THAT <br />SHALL EXTEND THE FULL WIDTH OF THE DOOR OR GATE. TEMPERED <br />GLASS DOOR WITHOUT VERTICAL STILES NEED NOT PROVIDE THE 10" AS <br />LONG AS THE TOP LEADING EDGE OF THE BOTTOM RAIL IS 60 DEGREES <br />MINIMUM FROM THE HORIZONTAL. <br />REMARKS <br />1 INSULATED DOOR <br />2 SELF -CLOSING, SELF -LATCHING INSULATED DOOR <br />I <br />3 SAFETY GLASS <br />4 VENT PER MECHANICAL DRAWINGS <br />5 GC TO VERIFY WITH DOOR MANUFACTURER THAT 34" NOMINAL <br />CLEARANCE IS PROVIDED AT ALL PASS THROUGH DOORS WITHIN UNITS <br />6 SOLID CORE <br />7 DOUBLE DOOR WITH ASTRAGAL, WEATHER STRIPPING ALL SIDES, DOOR <br />SWEEP (AUTOMATIC DOOR BOTTOM) <br />8 REQUIRES AUTOMATIC DOOR BOTTOM (ASSAABLOY SA3) FULL DOOR <br />WIDTH <br />9 T-0" DOOR WITH SIDELIG T <br />10 INTUMESCENT PAINT 1 <br />HARDWARE <br />A. <br />UNIT ENTRY DOOR: <br />1. <br />KEYED DEADBOLT - THUMBTURN INSIDE <br />2. <br />LATCHSET: KEYED ENTRY - WITH LEVER HANDLE <br />3. <br />HINGES: 1 PAIR 4" X 4" PAINTABLE SPRING HINGES AND % <br />PAIR 4" X 4" PAINTABLE STANDARD HINGE. <br />4. <br />KNOCKER / VIEWER. COORDINATE WI FHFC REQUIREMENTS <br />5. <br />STOP: CONVEX WALL STOP, <br />6. <br />SWEEP/SEAL: PROVIDE DOOR BOTTOM SWEEP TO SEAL AT <br />THRESHOLD AND NOT DRAG ON ENTRY FLOORING <br />7. <br />ADD DOORBELL - SEE ELEC. DRAWINGS <br />B. <br />BALCONY/PATIO DOOR <br />1. <br />DEADBOLT - THUMBTURN INSIDE, BLIND OUTSIDE <br />2. <br />LEVER STYLE LATCHSET: PASSAGE <br />3. <br />HINGES:1 PAIR 4" X 4" PAINTABLE SPRING HINGES <br />AND Yz PAIR 4" X 4" PAINTABLE STANDARD HINGE. <br />4. <br />STOP: ADJUSTABLE DOME <br />5. <br />SWEEPISEAL: PROVIDE DOOR BOTTOM SWEEP TO <br />SEAL AT THRESHOLD AND NOT DRAG ON FLOORING <br />C. <br />BEDROOM AND BATHROOM DOORS: <br />1. <br />LATCHSET: PRIVACY LATCH. <br />2. <br />HINGES: 1 '/z PAIR 3'/i' X 3 Yz' PAINTABLE STANDARD HINGES. <br />3, <br />STOP: SPRING DOOR STOP (TYPICAL); OR HINGE PIN DOOR <br />STOP, ONLY IF REQUIRED BASED ON LOCATION. <br />4. <br />PROVIDE UNDERCUT AT BEDROOM AND HALL DOORS PER <br />MECHANICAL. <br />D. <br />ALL OTHER INTERIOR SWING DOORS (INCLUDING LINEN CLOSET): <br />1. <br />LATCHSET: PASSAGE LATCH. <br />2. <br />HINGES: 1 Y2 PAIR 3'/z" X 3'/" PAINTABLE STANDARD HINGES. <br />3. <br />STOP: SPRING DOOR STOP (TYPICAL); OR HINGE PIN DOOR <br />STOP, ONLY IF REQUIRED BASED ON LOCATION. <br />E. <br />BUILDING <br />ENTRY DOOR: <br />1. <br />PULL AT EXTERIOR W/ MAGNETIC KEY / FOB <br />2. <br />PANIC HARDWARE <br />3. <br />BOTTOM SWEEP <br />4. <br />HINGES PER DOOR: (1)PAIR 4" X 4" HINGES AND 1/2 PAIR 4X4 <br />STANDARD HINGE <br />5. <br />CLOSER <br />6. <br />KICK PLATE <br />F. <br />BUILDING SIDE ENTRY DOOR: <br />1. <br />2. <br />PULL AT EXTERIOR W/ MAGNETIC KEY 1 FOB <br />PANIC HARDWARE <br />3. <br />BOTTOM SWEEP <br />4. <br />HINGES PER DOOR: (1)PAIR 4" X 4" HINGES AND 1/2 PAIR 4X4 <br />STANDARD HINGE <br />5. <br />CLOSER <br />6. <br />KICK PLATE <br />G. <br />BOOSTER PUMP I BUILDING SERVICES / ELEC CLOSETS: <br />1. <br />DEADBOLT - KEYED OUTSIDE, BLIND INSIDE <br />2. <br />PANIC HARDWARE <br />3. <br />PASSAGE LATCH <br />4. <br />(1) PAIR 4"x4" HINGES & 1/2 PAIR 4"x4" STANDARD HINGE <br />5. <br />BOTTOM SWEEP & DOOR SEAL <br />6. <br />CLOSER <br />H. <br />RISER / MECH CLOSETS: <br />1. <br />DEADBOLT - KEYED OUTSIDE, BLIND INSIDE <br />2. <br />PASSAGE LATCH <br />3. <br />(1) PAIR 4"x4" HINGES & 1/2 PAIR 4"x4" STANDARD HINGE <br />4. <br />BOTTOM SWEEP & DOOR SEAL <br />5. <br />CLOSER <br />I. <br />DAS CLOSET/ELEVATOR CLOSET: <br />1. <br />LATCHSET: PASSAGE LATCH <br />2. <br />HINGES: (1) PAIR 4"x4" HINGES & 1/2 PAIR 4"x4" STANDARD <br />HINGES <br />3. <br />STOP: SPRING DOOR STOP (TYPICAL); OR HINGE PIN DOOR <br />STOP, ONLY IF REQUIRED BASED ON LOCATION <br />J. <br />STAIR - EXTERIOR: <br />1. <br />PANIC HARDWARE WI HEAD AND FOOT BOLTS <br />2. <br />BLIND OUTSIDE (EXIT ONLY FOR SECURITY) <br />3. <br />BOTTOM SWEEP <br />4. <br />(1) PAIR 4"x4" HINGES & 1/2 PAIR 4"x4" STANDARD HINGE - ADD <br />CONCEALED HINGES FOR SECURITY <br />5. <br />CLOSER <br />6. <br />KICK PLATE <br />K. <br />STAIR - INTERIOR: <br />1. <br />PANIC HARDWARE <br />2. <br />PASSAGE LATCH <br />3. <br />BOTTOM SWEEP <br />4. <br />(1) PAIR 4" X 4" HINGES AND'/2 PAIR 4X4 STANDARD HINGE <br />5. <br />CLOSER <br />6. <br />KICK PLATE <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />09/16/2022 <br />Karen V McIntyre <br />AOnn17010 <br />SET DISTRIBUTIONS: <br />11/24/21 100% DD Set <br />12/23/21 Owner Review Set _ <br />02/17/22 Permit Set <br />0 SHEET REVISIONS: <br />a <br />C <br />M <br />4 <br />C <br />0 <br />E <br />U <br />0 <br />a <br />a� <br />L PROJECT NO. <br />4097 <br />Apartments - <br />Door Schedules & <br />Details <br />A9.11 <br />