Laserfiche WebLink
MARK <br />DESC <br />TYPE <br />W <br />H <br />HD HT <br />(S <br />REMARKS <br />AA <br />F <br />3 <br />3'4" <br />6'-0" <br />8'-0" <br />18 <br />SEE SHEET NOTE E <br />SEE SHEET NOTE E <br />* SEE ELEVATION FOR WINDOW HEAD HEIGHTS-1/A6.11 <br />BUILDING WINDOW SCHEDULE - BUILDING TYPE II <br />AREAREMARKS <br />MARK <br />DESC <br />TYPE <br />W <br />H <br />HD HT <br />CC <br />F <br />3 <br />T-0" <br />6'-0" <br />8'-0" <br />18 <br />SEE SHEET NOTE E <br />DID <br />F <br />4 <br />3'-0" <br />3'-0" <br />9 <br />SEE SHEET NOTE E <br />BUILDING WINDOW SCHEDULE - BUILDING TYPE I UNIT WINDOW SCHEDULE WINDOW TYPES SHEET NOTES CONTINUED SHEET NOTES <br />G WINDOWS SHALL MEET ALL FEDERAL, STATE, AND LOCAL A MATERIALS, TYPES, STYLES, SIZES, AND FINISHES FOR WINDOWS TO BE <br />REQUIREMENTS FOR ACCESSIBILITY, WHERE APPLICABLE, INCLUDING <br />CLEAR FLOOR SPACE, HEIGHT OF OPERABLE PARTS, AND FORCE <br />REQUIRED TO ACTIVATE OPERABLE PARTS. <br />H ALL WINDOWS SHALL BEAR THE APPROVED LABEL WITH THE <br />PRESSURES LISTED THAT MEET OR EXCEED THE REQUIRED PRESSURE <br />O FOR THE PROJECT AND BEAR A WDMA OR OTHER APPROVED LABEL <br />IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS, <br />AND APPROVED PRODUCT EVALUATION ENTITY TO INDICATE <br />COMPLIANCE WITH THE REQUIREMENT OF AAMANVDMA 101/I.S.2/NAFS. <br />J EMERGENCY ESCAPE AND RESCUE OPENINGS: IF REQUIRED, WINDOWS ENERGY STAR QUALIFIED, WHERE SPECIFIED. IF REQUIRED THE <br />O O O INDICATED AS "EMERGENCY EGRESS" ON THE DRAWINGS SHALL CRITERIA FOR U-FACTOR AND SHGC SHALL BE AS INDICATED ON THE <br />COMPLY WITH APPLICABLE CODE REQUIREMENTS. DRAWINGS OR AS OTHERWISE SPECIFIED. <br />1 K . WINDOW FRAME PROFILES INDICATED IN THE DETAILS ARE GENERIC C IF REQUIRED BY NOTE ON Al.02, WINDOWS SHALL BE IMPACT RATED <br />AND MAY NOT REFLECT THE ACTUAL WINDOW PROFILE PER THE AND COMPLY WITH APPLICABLE CODE AND THE AHJ. <br />AS INDICATED ON THE DRAWINGS AND AS SPECIFIED, WHERE <br />APPLICABLE, UNLESS OTHERWISE DIRECTED BY THE OWNER AND <br />APPROVED BY THE ARCHITECT. INSTALL WINDOWS LEVEL, PLUMB, <br />SQUARE, TRUE TO LINE, ANCHORED SECURELY, AND IN PROPER <br />RELATION TO FLASHING REQUIREMENTS AND OTHER ADJACENT <br />CONSTRUCTION. COMPLY WITH DRAWINGS, MANUFACTURER'S WRITTEN <br />INSTRUCTIONS, AND ALL APPLICABLE CODES. <br />B ALL EXTERIOR WINDOWS SHALL BE SEALED AND WEATHER STRIPPED. <br />WINDOW UNITS SHALL DISPLAY LABELS SHOWING COMPLIANCE WITH <br />THE STATE'S ENERGY CODE. WINDOWS MAY ALSO BE REQUIRED TO BE <br />* SEE ELEVATION FOR WINDOW HEAD HEIGHTS-11A6,21 WINDOW MANUFACTURER SPECIFIED OR OTHERWISE SELECTED. THE <br />CONTRACTOR SHALL INSTALL WINDOWS TO PREVENT WATER INTRUSION <br />D IF REQUIRED, FIRE -RATED WINDOWS SHALL COMPLY WITH APPLICABLE <br />PER SPECIFICATIONS AND DETAILS INDICATED ON THE DRAWINGS. <br />CODE, NFPA 80, AND DISPLAY REQUIRED LABELS PER CODE. REFER TO <br />THE DOOR AND WINDOW SHEETS FOR FIRE -RATED LOCATIONS. <br />L THE CONTRACTOR MUST SUBMIT PROPOSED WINDOWS TO THE <br />ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. THE SUBMITTAL <br />E GLAZING IN HAZARDOUS LOCATIONS, AS DEFINED BY THE BUILDING <br />SHALL BE COMPLETE WITH PROPOSED WINDOW INSTALLATION DETAILS <br />CODE, SHALL HAVE SAFETY GLAZING MATERIAL IN COMPLIANCE WITH <br />RELATIVE TO THE CONDITIONS INDICATED AND AS NOTED ION THE <br />THE BUILDING CODE AND CPSC 16 CFR 1201 OR ANSI Z97.1 AS <br />SPECIFICATIONS. <br />APPROPRIATE. REFER TO DOOR AND WINDOW SHEETS FOR <br />HAZARDOUS LOCATIONS. <br />F OPERABLE WINDOWS, WHERE THE OPENING OF THE SILL PORTION IS <br />MORE THAN 72" ABOVE THE FINISHED GRADE AND LESS THAN 24" ABOVE <br />THE FINISHED FLOOR SURFACE, SHALL HAVE WINDOW OPENING <br />CONTROL DEVICES (WOCD) COMPLIANT WITH ASTM F 2090. <br />BUILDING WRAP <br />STONE VENEER <br />MORTAR SETTING BED <br />CEMENT PLASTER SCRATCH COAT <br />MORTAR JOINTS <br />LATH PER SPECIFICATIONS <br />ASPHALT PAPER <br />CONT SEALANT W/ BACKER <br />ROD AS NEEDED <br />HARD COAT FOAM BAND <br />PER ELEVATIONS WI DRIP <br />-SLOPE TOP 15" MIN <br />SELF ADHERING FLASHING <br />CASING BEAD <br />GAP, NO SEALANT <br />METAL FLASHING <br />CONT SEALANT <br />CONT SEALANT <br />BEHIND WINDOW FIN <br />Window Head <br />at Stone Veneer & Foam Band <br />EXTERIOR SHEATHING <br />BUILDING WRAP <br />STONE VENEER <br />CEMENT PLASTER SCRATCH COAT <br />MORTAR SETTING BED <br />ASPHALT PAPER <br />CONT SEALANT W/ BACKER <br />ROD AS NEEDED <br />LATH PER SPECIFICATIONS <br />SELF ADHERING FLASHING <br />CASING BEAD <br />HARD COAT FOAM BAND <br />PER ELEVATIONS <br />CONT SEALANT W/ BACKER <br />ROD AS NEEDED <br />CONT SEALANT <br />BEHIND WINDOW FIN <br />Window Jamb <br />at Stone Veneer & Foam Band <br />WINDOW PER SCHEDULE <br />SHIM AS NEEDED,1/4" MAX <br />DISCONTINUOUS SEALANT BEHIND <br />WINDOW FIN, (2) 2" MIN. GAPS <br />CONT SEALANT W/ BACKER <br />ROD AS NEEDED <br />CASING BEAD <br />HARD COAT FOAM BAND PER <br />ELEVATIONS SLOPE TOP 150 MIN <br />SELF ADHERING FLASHING <br />CONT SEALANT W/ BACKER <br />ROD AS NEEDED <br />ASPHALT PAPER <br />LATH PER SPECIFICATIONS <br />MORTAR SETTING BED <br />MORTAR JOINTS <br />CEMENT PLASTER SCRATCH COAT <br />STONE VENEER <br />BUILDING WRAP <br />Window Sill <br />at Stone Veneer & Foam Band <br />i <br />EXTERIOR SHEATHING <br />BUILDING WRAP <br />FIBER CEMENT LAP SIDING <br />i <br />EXTERIOR SHEATHING <br />i <br />SELF ADHERING FLASHING <br />BUILDING WRAP <br />\ / <br />(PER FIBER CEMENT PANELMFR <br />SELF ADHERING FLASHING TO EXTEND <br />RECOMMENDATIONS) <br />2" PAST END OF FIBER CEMENT TRIM i <br />EXTERIOR SHEATHING <br />FIBER CEMENT PANEL -----.,,,FIBER <br />CEMENT STARTER STRIP z <br />HEADER PER STRUCTURAL DRAWINGS <br />SELF ADHERING FLASHING TO EXTEND <br />HEADER PER STRUCTURAL DRAWINGS <br />GAP, NO SEALANT Z <br />HEADER PER STRUCTURAL DRAWINGS <br />2" PAST END OF FIBER CEMENT TRIM <br />INTERIOR SHEATHING <br />INTERIOR SHEATHING <br />METAL FLASHING <br />INTERIOR SHEATHING <br />CONT SEALANT <br />SHIM AS NEEDED, 14'MAX <br />SHIM AS NEEDED, 114" MAX <br />SHIM AS NEEDED, 1l4" MAX <br />5/4 FIBER CEMENT TRIM <br />\ <br />SLOPE TOP AT 15" \ <br />CONT SEALANT <br />METAL FLASHING----_514 <br />FIBER CEMENT TRIM z <br />\ <br />N <br />METAL FLASHING N <br />GAP, NO SEALANT ��� oo <br />GAP, NO SEALANT <br />CONT SEALANT AT ROUGH <br />CONT SEALANT <br />CONT SEALANT AT ROUGH <br />CONT SEALANT <br />CONT SEALANT AT ROUGH <br />OPENING TO WINDOW FRAME <br />OPENING TO WINDOW FRAME <br />OPENING TO WINDOW FRAME <br />CONT SEALANT <br />CONT SEALANT <br />CONT SEALANT AT RETURN <br />BEHIND WINDOW FIN <br />CONT SEALANT AT RETURN <br />BEHIND WINDOW FIN <br />CONT SEALANT AT RETURN <br />TO WINDOW FRAME <br />TO WINDOW FRAME <br />TO WINDOW FRAME <br />WINDOW PER SCHEDULE <br />WINDOW PER SCHEDULE <br />WINDOW PER SCHEDULE <br />Window Head <br />( � �W�ido�wHe ad <br />3" = 1'-0" v i at Fiber Cement Panel <br />EXTERIOR SHEATHING <br />BUILDING WRAP <br />(PER FIBER CEMENT PANEL <br />MFR RECOMMENDATIONS) <br />FIBER CEMENT PANEL <br />OR SHEATHING SELF ADHERING FLASHING <br />TO EXTEND 2" PAST END <br />FRAMING PER STRUCTURAL OF FIBER CEMENT TRIM <br />INGS <br />CONT SEALANT <br />\S NEEDED,1/4" MAX <br />5/4 FIBER CEMENT TRIM <br />NG WRAP <br />CONT SEALANT <br />BEHIND WINDOW FIN <br />SEALANT AT ROUGH <br />NG TO WINDOW FRAME <br />SEALANT AT <br />tN TO WINDOW FRAME <br />)W PER SCHEDULE <br />3" = 1'-011 <br />CONT SEALANT AT SILL <br />TO WINDOW FRAME <br />CONT SEALANT AT ROUGH <br />OPENING TO WINDOW FRAME <br />WOODEN BACK DAM <br />SELF ADHERING FLASHING, <br />WRAPPED INTO ROUGH OPENING <br />AND OVER WOODEN BACK DAM <br />CONT SEALANT <br />APRON & SILL SELECTED BY OWNER <br />CONT SEALANT <br />WOOD FRAMING PER STRUCTURAL <br />DRAWINGS <br />INTERIOR SHEATHING <br />EXTERIOR SHEATHING <br />3" = 1'-0" <br />CONT SEALANT WITH <br />BACKER ROD AS NEEDED <br />3" = 1'-0" <br />INTERIOR SHEATHING <br />WOOD FRAMING PER STRUCTURAL <br />DRAWINGS <br />SHIM AS NEEDED, 1/4"MAX <br />L:LBUILDING WRAP, <br />i FOLD INTO OPENING <br />Window Jamb <br />at Fiber Cement Panel <br />WINDOW PER SCHEDULE <br />SHIM AS NEEDED,1/4" MAX <br />CONT SEALANT W/ BACKER <br />ROD AS NEEDED <br />DISCONTINUOUS SEALANT BEHIND <br />WINDOW FIN, (2) 2" MIN. GAPS <br />5/4 FIBER CEMENT TRIM <br />SLOPE TOP AT 150 <br />CONT SEALANT <br />SELF ADHERING FLASHING <br />TO EXTEND 2" PAST END <br />OF FIBER CEMENT TRIM <br />FIBER CEMENT PANEL <br />BUILDING WRAP <br />(PER FIBER CEMENT PANEL <br />MFR RECOMMENDATIONS) <br />EXTERIOR SHEATHING <br />Window Sill <br />at Fiber Cement Panel <br />CONT SEALANT AT ROUGH <br />OPENING TO WINDOW FRAME <br />CONT SEALANT AT <br />RETURN TO WINDOW FRAME <br />WINDOW PER SCHEDULE <br />3" = 1'-0" <br />CONT SEALANT AT SILL <br />TO WINDOW FRAME <br />CONT SEALANT AT ROUGH <br />OPENING TO WINDOW FRAME <br />SELF ADHERING FLASHING, <br />FOLD INTO OPENING <br />'CONT SEALANT <br />APRON & SILL SELECTED BY OWNER <br />CONT SEALANT <br />i <br />WOOD FRAMING PER STRUCTURAL <br />DRAWINGS <br />INTERIOR SHEATHING <br />i <br />3" = 1'-0" <br />at Fiber Cement Lap Siding <br />EXTERIOR SHEATHING - <br />BUILDING WRAP - <br />FIBER CEMENT LAP SIDING - <br />SELF ADHERING FLASHING - <br />TO EXTEND 2" PAST END <br />OF FIBER CEMENT TRIM <br />CONT SEALANT- <br />5/4 FIBER CEMENT TRIM- <br />CONT SEALANT - <br />BEHIND WINDOW FIN <br />CONT SEALANT WITH - <br />BACKER ROD AS NEEDED <br />3" = 1'-0" <br />INTERIOR SHEATHING <br />WOOD FRAMING PER STRUCTURAL <br />DRAWINGS <br />i <br />SHIM AS NEEDED, 1/4" MAX <br />/ BUILDING WRAP, <br />i FOLD INTO OPENING <br />Window Jamb <br />at Fiber Cement Lap Siding <br />WINDOW PER SCHEDULE <br />SHIM AS NEEDED,1/4" MAX <br />CONT SEALANT W/ BACKER <br />ROD AS NEEDED <br />DISCONTINUOUS SEALANT BEHIND <br />WINDOW FIN, (2) 2" MIN. GAPS <br />5/4 FIBER CEMENT TRIM <br />SLOPE TOP AT 15" <br />CONT SEALANT <br />SELF ADHERING FLASHING <br />TO EXTEND 2" PAST END <br />OF FIBER CEMENT TRIM <br />FIBER CEMENT LAP SIDING <br />BUILDING WRAP <br />EXTERIOR SHEATHING <br />Window Sill <br />at Fiber Cement Lap Siding <br />CONT SEALANT AT ROUGH <br />OPENING TO WINDOW FRAME <br />CONT SEALANT AT <br />RETURN TO WINDOW FRAME <br />WINDOW PER SCHEDULE <br />3" = 1'-0" <br />kLANT AT SILL <br />)W FRAME <br />kLANT AT ROUGH <br />TO WINDOW FRAME <br />IERING FLASHING, <br />D OPENING <br />kLANT <br />SILL SELECTED BY OWNER <br />kLANT <br />AMING PER STRUCTURAL <br />S <br />SHEATHING <br />3" = 1'-011 <br />ro <br />FORUME <br />ARCHITECTURE & <br />a <br />INTERIOR DESIGN, INC. <br />C <br />C <br />m <br />237 S. Westmonte Drive, Suite 220 <br />`o <br />Altamonte Springs, FL 32714 <br />c 407.830.1400 <br />AR97193 <br />www.foru marchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />09/16/2022 <br />Karen V McIntyre <br />AR0017018 <br />SET DISTRIBUTIONS: <br />11/24/21 100% DID Set <br />L 12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />Q SHEET REVISIONS: <br />r PROJECT NO. 4097 <br />F <br />Apartments - <br />Window Schedules <br />& Details <br />A9.21 <br />MARK <br />DESC <br />TYPE <br />W <br />H <br />HD HT <br />NSF) <br />REMARKS <br />A <br />SH <br />1 <br />3'-0" <br />6-4' <br />$'-0" <br />18 <br />B <br />SH <br />2 <br />6'-0" <br />6-0" <br />8'-0" <br />36 <br />C <br />SH <br />1 <br />2'-0" <br />4'4" <br />8'-0" <br />9 <br />D <br />SH <br />1 <br />2'4" <br />4'-8" <br />8'-0" <br />12 <br />