E FLOOR / CEILING ASSEMBLIES <br />ROOF / CEILING ASSEMBLIES (CONT) <br />CONSTRUCTION ASSEMBLY NOTES <br />TYPICAL AT UNITS / INTERIOR SPACES <br />FW 1 <br />FLOORING PER INTERIOR FINISH SCHEDULE/NOTES <br />3/4" POURED GYPSUM CONCRETE UNDERLAYMENT <br />1 HOUR RATED <br />SOUND UNDERLAYMENT WITH PERIMETER ISOLATION <br />THROUGHOUT ALL UNIT AREAS. GC TO SUBMIT MFR TEST <br />1 <br />DATA INDICATING MIN IIC 50 COMPLIANCE WITH ASSEMBLY <br />UNDERWRITER'S <br />J U <br />(1) LAYER 3/4" (NOMINAL) T&G WOOD STRUCTURAL PANEL <br />LABORATORY <br />SHEATHING SUBFLOOR PER STRUCTURAL DRAWINGS <br />(UL) DESIGN <br />20" WOOD TRUSS AT 24" OC MAX PER STRUCTURAL DRAWINGS <br />L546 <br />UNFACED BATT INSULATION: SECURE TO SUBFLOOR (BASE <br />BID) OR OVER RC AS NOTED BELOW (ALT DEDUCT) <br />IIC 50+ <br />PER <br />ili'tt` - - <br />;Oi li lli 1(1(1('�(1�; ' i 1(4n <br />� , <br />RESILIENT CHANNELS PERPENDICULAR TO TRUSSES AT 16" <br />A1176.02-201-10 <br />"� "� " "� "� )l " "� " "" <br />OC, REDUCE TO 12" OC IF INSULATION LOCATED OVER <br />A8745.06-201-10 <br />CHANNELS <br />100528151CRT-001M <br />(1) LAYER 5/8" FIRE -RATED TYPE C GYPSUM BOARD (EXT <br />GRADE AT NON -CONDITIONED SPACE) <br />TYPICAL AT UNIT BALCONY <br />FW 5 <br />1.5" MIN NORMALWEIGHT OR LIGHTWEIGHT CONCRETE <br />TOPPING ON 60 MIL (MIN) ELASTOMERIC MEMBRANE <br />(1) LAYER 3/4" (NOMINAL) T&G WOOD STRUCTURAL PANEL <br />1 HOUR RATED <br />SHEATHING SUBFLOOR PER STRUCTURAL DRAWINGS <br />WOOD TRUSS AT 24" OC MAX PER STRUCTURAL DRAWINGS <br />UNDERWRITER'S <br />WITH SLOPED TOP CHORD TO PROVIDE 18" DEPTH AT T.O. <br />LABORATORY <br />SLOPE AND 17" AT B.O. SLOPE <br />(UL) DESIGN <br />L528 <br />RESILIENT CHANNELS PERPENDICULAR TO TRUSSES AT 16" OC <br />(1) LAYER 5/8" FIRE -RATED TYPE C EXT GRADE GYPSUM BOARD <br />TYPICAL AT INTERIOR LOCATION(S) <br />/ <br />FLOORING PER INTERIOR FINISH SCHEDULE/NOTES <br />3/4" POURED GYPSUM CONCRETE UNDERLAYMENT <br />2 HOUR RATED <br />(1) LAYER 3/4" (NOMINAL) T&G WOOD STRUCTURAL PANEL <br />SHEATHING SUBFLOOR PER STRUCTURAL DRAWINGS <br />;.,.., <br />20" WOOD TRUSS AT 24" OC MAX PER STRUCTURAL DRAWINGS <br />UNDERWRITER'S <br />U U L U M U " <br />LABORATORY <br />(UL) DESIGN <br />L577 <br />UNFACED BATT INSULATION: SECURE TO SUBFLOOR <br />(1) LAYER 5/8" FIRE -RATED TYPE C GYPSUM BOARD <br />RESILIENT CHANNELS PERPENDICULAR TO TRUSSES AT 12" OC <br />(2) LAYER 518" FIRE -RATED TYPE C GYPSUM BOARD (FACE <br />LAYER TO BE EXT GRADE AT NON -CONDITIONED SPACE) <br />NOTE: NO DUCTS/DAMPERS ALLOWED <br />TYPICAL WITHIN STAIR UNIT <br />FW 10 <br />FLOORING PER INTERIOR FINISH SCHEDULE/NOTES <br />3/4" POURED GYPSUM CONCRETE UNDERLAYMENT <br />1 HOUR RATED <br />(1) LAYER 3/4" (NOMINAL) T&G WOOD STRUCTURAL PANEL <br />SHEATHING SUBFLOOR PER STRUCTURAL DRAWINGS <br />2x10 JOISTS AT 16" OC MAX PER STRUCTURAL DRAWINGS <br />UNDERWRITER'S <br />RESILIENT CHANNELS PERPENDICULAR TO JOISTS AT 24" OC <br />LABORATORY <br />(UL) DESIGN <br />(1) LAYER 5/8" FIRE -RATED TYPE C GYPSUM BOARD <br />L514 <br />TYPICAL AT PITCHED ROOF <br />RW 1 <br />ROOFING PER PLANS, ELEVATIONS AND DETAILS: <br />A. ARCHITECTURAL FIBERGLASS ASPHALT SHINGLES <br />B. STANDING SEAM METAL ROOF PANELS <br />1 HOUR RATED <br />,�,�,—� <br />.� <br />C. CONCRETE ROOF TILE SET WITH FOAM ADHESIVE <br />ROOF UNDERLAYMENT PER SPECIFICATIONS AND ROOFING <br />��- <br />SYSTEM REQUIREMENTS <br />UNDERWRITER'S <br />LABORATORY <br />(UL) DESIGN <br />(1) LAYER 112" 5/8" (NOMINAL) WOOD STRUCTURAL PANEL <br />ROOF SHEATHING PER STRUCTURAL DRAWINGS <br />P522 <br />WOOD TRUSS AT 24" OC MAX PER STRUCTURAL DRAWINGS <br />WITH SLOPE PER ROOF PLAN(S) <br />BLOWN OR BATT INSULATION OVER CONDITIONED SPACES <br />1 ` <br />RESILIENT CHANNELS PERPENDICULAR TO TRUSSES AT 12" OC <br />(1) LAYER 5/8" FIRE -RATED TYPE C GYPSUM BOARD (EXTERIOR <br />GRADE AT UNCONDITIONED SPACES) <br />TYPICAL AT 2-HOUR CEILING MEMBRANE <br />RW 5 <br />O <br />(1) LAYER 3/4" (NOMINAL) WOOD STRUCTURAL PANEL <br />SHEATHING PER STRUCTURAL DRAWINGS <br />2x8 JOISTS AT 24" OC MAX PER STRUCTURAL DRAWINGS <br />2 HOUR RATED <br />GYPSUM <br />(3) LAYERS 5/8" FIRE -RATED GYPSUM BOARD <br />ASSOCIATION <br />(GA) DESIGN <br />FC 5725 <br />i—, <br />7/8" METAL FURRING CHANNELS PERPENDICULAR TO JOISTS <br />AT 24" OC <br />(1) LAYER 5/8" FIRE -RATED TYPE X GYPSUM BOARD (EXTERIOR <br />GRADE AT UNCONDITIONED SPACES) <br />I NT <br />(FIRE SIDE) <br />NOTE: NO INSULATION OR DUCTS/DAMPERS ALLOWED <br />TYPICAL AT CAP SLAB WITHIN TRUSS CAVITY AND ABOVE UNFINISHED/UNCONDITIONED SPACE <br />RC-53 <br />2 HOUR RATED <br />6" THICK CONCRETE SLAB PER STRUCTURAL DRAWINGS <br />CALCULATED <br />PER <br />FBC-B 722.2.2.1 <br />e <br />a <br />(REFER TO <br />CALCULATIONS <br />1 <br />ON THIS SHEET) <br />A ASSEMBLIES MAY NOT BE NUMBERED IN SEQUENTIAL ORDER. <br />B THE INDICATED UL ASSEMBLIES AND OTHER SPECIFIED FIRE RATED DESIGNS ARE THE "BASIS OF DESIGN" FOR FIRE SAFETY, SOUND <br />TRANSMISSION, MATERIAL SELECTION, ETC. THE COMPONENTS OF THE RATED ASSEMBLY SHALL BE PER THE SPECIFIED FIRE TEST AND/OR <br />SOUND TEST. THE CONTRACTOR MAY SUBMIT ALTERNATE ASSEMBLIES FOR REVIEW AND APPROVAL BY THE ARCHITECT, PRIOR TO <br />CONSTRUCTION, TO BE USED IN PLACE OF THE ASSEMBLIES INDICATED ON THESE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL <br />PROVIDE ALL MATERIALS AND EQUIPMENT AS INDICATED IN THE ASSEMBLY AND/OR WITHIN THE SYSTEM THAT IS PART OF THE ASSEMBLY. <br />SUBSTITUTION OF MATERIALS OR ADDITIONAL MATERIALS WHICH ARE NOT ALLOWED PER THE ASSEMBLY WILL NOT BE ACCEPTED. APPROVAL <br />OF THE ASSEMBLY BY THE ARCHITECT DOES NOT RELEASE THE CONTRACTOR FROM THE RESPONSIBILITY OF MEETING ALL APPLICABLE CODES <br />AND REGULATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR SUBMITTING DOCUMENTATION OF ANY PROPOSED ALTERNATE ASSEMBLIES <br />TO THE AHJ FOR APPROVAL PRIOR TO CONSTRUCTION. <br />C CONTRACTOR TO PROVIDE CURRENT UL LISTED PENETRATION FIRESTOP SYSTEM DESIGNS AND INSTALLATIONS COMPATIBLE FOR THE FIRE <br />RATED ASSEMBLIES BEING PENETRATED. SUBMIT COPIES OF UL LISTED PENETRATION SYSTEMS TO ARCHITECT FOR REVIEW AND APPROVAL, <br />PRIOR TO CONSTRUCTION. CONTRACTOR IS ALSO RESPONSIBLE FOR SUBMITTING DOCUMENTATION OF PROPOSED PENETRATION FIRESTOP <br />SYSTEM TO THE AHJ FOR APPROVAL PRIOR TO CONSTRUCTION. <br />D THE ANNULAR SPACE OF PENETRATIONS OF METAL PIPING OR TUBING WITH A MAX 6" DIA. THROUGH HORIZONTAL ASSEMBLIES SHALL BE <br />PROTECTED PER CODE OR BY AN APPROVED FIRESTOP SYSTEM. <br />E FIRESTOP SYSTEM PENETRATIONS THROUGH WALLS SHALL HAVE'F' RATINGS MATCHING THE WALL BEING PENETRATED. <br />F FIRESTOP SYSTEM PENETRATIONS THROUGH HORIZONTAL ASSEMBLIES SHALL HAVE'F' &'T' RATINGS MATCHING THE FLOOR BEING <br />PENETRATED, EXCEPT THAT T-RATINGS ARE NOT REQUIRED WHERE THE PENETRATIONS OCCUR WITHIN THE CAVITIES OF WALLS PER CODE. <br />G COPIES OF ALL REFERENCED FIRE -RATED DESIGNS HAVE BEEN INCLUDED IN THE PROJECT MANUAL SPECIFICATIONS. <br />H FOR NEW BUILDINGS THREE STORIES OR GREATER IN HEIGHT, THE FOLLOWING QUALITY ASSURANCE PROGRAM FOR FIRE -STOP SYSTEMS, <br />PENETRATIONS AND JOINTS SHALL BE PROVIDED BY THE OWNER: INSPECTIONS OF INSTALLED FIRE -STOP SYSTEMS SHALL BE PERFORMED BY <br />A THIRD PARTY INSPECTOR IN ACCORDANCE WITH NFPA-1-2012 FIRE CODE SECTION 12.3.2, PER ASTM E 2174 AND E 2393 AS APPLICABLE, IN <br />ACCORDANCE WITH AHJ REQUIREMENTS. THE THIRD PARTY INSPECTOR WILL BE CONTRACTED BY THE OWNER. REFER ALSO TO <br />SPECIFICATIONS DIVISION 07, PENETRATION FIRESTOPPING. <br />I RESILIENT CHANNEL (RC) INSTALLATION: FOR ALL WALLS SCHEDULED WITH RC, INSTALL HORIZONTALLY AT 24" OC MAX, 4"-6" FROM CEILING <br />AND 2" FROM BOTTOM, AND AS REQUIRED TO SUPPORT CABINETS, ALWAYS WITH OPEN LEG POINTING UP. NEST/OVERLAP CHANNEL ENDS 4". <br />FOR ALL CEILINGS SCHEDULED WITH RC, INSTALL PER TESTED ASSEMBLY REFERENCED. PROVIDE A 1l4"-1/2" GAP BETWEEN THE ENDS OF ALL <br />RC AND ADJACENT CONSTRUCTION. SCREWS USED TO ATTACH GYP BD TO RC SHALL NOT DIRECTLY CONTACT FRAMING/STRUCTURE. <br />J ACOUSTICAL SEALANT: APPLY CONTINUOUS BEAD OF ACOUSTICALSEALANT (114"-112") APPROVED FOR USE IN FIRE -RATED ASSEMBLIES AS <br />NOTED BELOW AS A CRITICAL COMPONENT OF ACHIEVING A MINIMUM SOUND RATING OF STC & IIC 50 PER FBC/IBC CHAPTER 12: <br />• WITHIN ALL DWELLING UNITS ABOVE THE GROUND FLOOR, APPLY ACOUSTICAL SEALANT AT THE BOTTOM OF GYP BD SHEATHING INSTALLED <br />ON INTERIOR WALLS, TENANT WALLS, AND WALLS SEPARATING UNITS FROM COMMON AREAS, CORRIDORS AND/OR BREEZEWAYS. <br />• WITHIN ALL DWELLING UNITS, APPLY ACOUSTICAL SEALANT AROUND THE PERIMETER OF ALL MEMBRANE PENETRATIONS OF GYP BD WALL <br />AND CEILING SHEATHING INSTALLED ON TENANT WALLS, WALLS SEPARATING UNITS FROM COMMON AREAS, CORRIDORS AND/OR <br />BREEZEWAYS, AND AT FLOOR -CEILING ASSEMBLIES. SUCH MEMBRANE PENETRANTS INCLUDE ELECTRICAL BOXES (FOR SWITCHES, <br />OUTLETS, LIGHT FIXTURES AND CEILING FANS), MECHANICAL DUCTWORK I BOXES, SPRINKLER HEADS, ETC. <br />K REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING BUT NOT LIMITED TO LUMBER SIZE/GRADE/SPACING, <br />ATTACHMENT, ADDITIONAL ENGINEERED WOOD SHEATHING REQUIRED TO DEVELOP SHEAR, SCHEDULES FOR <br />COLUMNS/POST/HEADERS/LINTELS AND OTHER REQUIREMENTS. <br />RATED ASSEMBLY CALCULATIONS (AS REFERENCED) <br />WOOD WALLS (FROM FIRE SIDE) PER FBC 722.6: <br />FIRE RATING AT CMU WALLS PER FBC 722.3.2: <br />RATING <br />RATING <br />MATERIAL <br />(MINUTES) <br />AGGREGATE & MIN EQUIV THICKNESS (HOURS) <br />WOOD STUDS AT 16" OC MAX <br />20 <br />LIMESTONE AT 2.7" OR SILICEOUS AT 2.8" 1 <br />(1) LAYER 5/8" FIRE -RATED <br />40 <br />LIMESTONE AT 4.0" OR SILICEOUS AT 4.2" 2 <br />TYPE X GYP BD <br />TOTAL TIME <br />60 <br />AT CIP CONCRETE PER FBC 722.2: <br />AT CIP COLUMNS PER FBC 722.2.4: <br />CMU COLUMNS PER 722.3.5 <br />MIN THICKNESS SLAB/WALL <br />TYPICAL <br />(WORST -CASE RATING <br />MIN RATING <br />DIMENSION RATING <br />AGGREGATE) (HOURS) <br />DIMENSION (HOURS) <br />(MIN SIDE) (HOURS) <br />3.5" 1 <br />8" 1 <br />8" 1 <br />5.0" 2 <br />10" (OR 8" X 36" MIN) 2 <br />10" 2 <br />6.25" 3 <br />12" (OR 8" X 36" MIN) 3 <br />12" 3 <br />7.0" 4 <br />14" (OR 10" X 36" MIN) 4 <br />16"+ 4 <br />ASSEMBLY TAG <br />ASSEMBLY TYPE <br />W = <br />WALL <br />F = <br />FLOOR <br />R = <br />ROOF <br />ASSEMBLY MATERIAL <br />W = <br />WOOD <br />C = <br />CONCRETE <br />P77—S = STEEL <br />ASSEMBLY NUMBER <br />0 INSULATION <br />DESIGN INSULATION MIN VALUES <br />FOR ASSEMBLIES SCHEDULED <br />WITH INSULATION, TYPICAL/UNO: <br />R-11 MIN AT TENANT SEPARATION <br />R-13 AT 2x4 STUD FRAMING <br />R-19 AT 2x6 STUD FRAMING <br />R-30 AT ATTIC <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />09/16/2022 <br />Karen V McIntyre <br />SET DISTRIBUTIONS: <br />11/24/21 100%" DD Set <br />12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />0 SHEET REVISIONS: <br />PROJECT NO. 4097 <br />Aaprtments - <br />Construction & <br />Referenced <br />Assemblies <br />Al .05 <br />