Laserfiche WebLink
1 <br />�J <br />UNIT A2 <br />I <br />TRAVEL WITHIN UNIT <br />= 48'-5" (FFPC) <br />UNIT C1 UNIT S5 1 U IT B2 <br />r7l[L� I [ <br />-��PD <br />- <br />5 <br />32" <br />36" 02 TRAVEL TO EXIT = 76 4' (FFPC) <br />oI Io �El 12 o El oo El <br />Building T <br />Building T <br />Third Floor Similar <br />34 <br />UNIT Al � � UNIT Al �{ UNIT Al <br />S OCCUPANCY & MEANS OF EGRESS: RESIDENTIAL BUILDINGS <br />SHEET NOTES <br />OCCUPANCY LOAD (FBC-B TABLE 1004.5 & FFPC TABLE 7.3.1.2) <br />A <br />REFER TO SHEET A1.03 FOR GENERAL NOTES <br />RESIDENTIAL UNITS (R-2) 200 S.F. GROSS/ <br />OCC. <br />B <br />RATINGS SHOWN INDICATE REQUIRED SEPARATION RATINGS ONLY, <br />REFER TO SHEET A1.02 FIRE -RESISTANCE RATING REQUIREMENTS FOR <br />TRAVEL DISTANCE FBC-B TABLE 1017.2 & FFPC 30.2.E <br />( ) <br />FBC-B ALLOWED <br />FFPC ALLOWED <br />PROPOSED <br />BUILDING ELEMENTS AND SHEETS A1,04 AND A1.05 FOR ALL <br />WITHIN DWELLING UNITS <br />N/A <br />125'-0" <br />53' <br />CONSTRUCTION ASSEMBLIES, ASSEMBLIES REFERENCED WITHIN THESE <br />UNIT ENTRY TO AN EXIT <br />N/A <br />200'-0" <br />100'-6" <br />DOCUMENTS COMPLY WITH BOTH SETS OF REQUIREMENTS <br />MOST REMOTE POINT WITHIN A STORY TO AN EXIT <br />250'-0" <br />N/A <br />129'-5" <br />C <br />OPENINGS INTO AND THROUGH ASSEMBLIES RATED FOR SEPARATION <br />EXITING REQUIREMENTS <br />FBC-B REQUIRED <br />FFPC REQUIRED <br />PROPOSED <br />SHALL BE PROTECTED AS NOTED ON A1.03, SPECIFICATION SECTION <br />NUMBER OF EXITS (FBC-B 1006 & FFPC 7.4) <br />2 EXITS <br />2 EXITS <br />2 EXITS <br />078413, AND PER CODE REQUIREMENTS <br />STAIR (COMMON) (FBC-B 1011 & FFPC 7.2.2) <br />D <br />SEE CONTRACTOR'S FIRE PROTECTION DRAWINGS FOR STANDPIPE AND <br />WIDTH <br />44" (MIN) <br />44" (MIN) <br />>44" <br />HOSE CONNECTION DETAIL, COORDINATE LOCATIONS WITH <br />RISE <br />7" (MAX) <br />4" (MIN) - 7" (MAX) <br />6" < R < T' <br />ARCHITECTURAL PLANS <br />RUN <br />11" (MIN) <br />1V (MIN) <br />11" <br />E <br />SEE CONTRACTOR'S FIRE PROTECTION DRAWINGS FOR IDENTIFICATION <br />LANDING <br />36" (MIN) <br />36' (MIN) <br />>36" <br />OF SPRINKLER AREAS AND SPRINKLER SYSTEM TYPE <br />HEADROOM <br />80" <br />80" <br />>801, <br />HANDRAIL DIAMETER <br />1.25"-2" (MAX) <br />1.25"-2" (MAX) <br />1.5" <br />F <br />LOCATE FIRE EXTINGUISHERS PER FLOOR AS SHOWN AND AS <br />HANDRAIL PROJECTION FROM WALL <br />1.5" <br />2.25" <br />2.25" <br />OTHERWISE NECESSARY SUCH THAT THE TRAVEL DISTANCE FROM ANY <br />POINT ON THE FLOOR TO THE NEAREST EXTINGUISHER IS WITHIN 75' <br />G <br />REFER TO ELECTRICAL DRAWINGS FOR EXIT AND EMERGENCY LIGHT <br />AND TWO-WAY COMMUNICATIONS SYSTEM LOCATIONS <br />a <br />H <br />CONTRACTOR SHALL COORDINATE WITH THE AHJ AND VERIFY WHETHER <br />SEPARATE PERMITS SHALL BE REQUIRED FOR THE FIRE ALARM SYSTEM, <br />FIRE SPRINKLER SYSTEM, AND FIRE SUPPRESSION SYSTEM <br />13-- <br />II �� <br />�� ► �� i i� <br />-1� �► <br />�) I *i►, ■II <br />► 0 <br />II <br />�_.�.�:�,�J <br />�o <br />�� <br />� 1. �I'® <br />��; I■❑, � ����� <br />ID �, ■ <br />� <br />r� —� <br />_�_— �-,��. <br />��� <br />IQ;♦y <br />-- - - <br />1 <br />®I <br />I <br />o <br />I <br />= ''�I= i <br />�. <br />�� �� I II <br />I <br />I <br />■ <br />e I - Fourth Floor Life Safety Plan <br />e I - Second Floor Life Safety Plan <br />v to <br />FROM FLOORS ABOVE <br />TRAVEL WITHIN UNIT <br />= 42'-7" (FFPC) <br />FROM FLOORS ABOVE <br />I <br />1 /16" = 1'-0" <br />1 /16" = 1'-O" <br />35 <br />M35 <br />32" <br />36" <br />FIRE PROTECTION RESPONSIBILITY <br />THE CONTRACTOR'S FIRE PROTECTION ENGINEER SHALL BE THE <br />"ENGINEER OF RECORD" FOR THE FIRE PROTECTION SYSTEM AND SHALL <br />PREPARE COMPLETE AND FINAL FIRE PROTECTION DESIGN DOCUMENTS <br />WITH HYDRAULIC CALCULATIONS, SIGNED AND SEALED, AS DEFINED BY THE <br />F.A.C. 61G15-32 AND SHALL SUBMIT REQUIRED DOCUMENTATION TO THE <br />ARCHITECT FOR GENERAL REVIEW. UPON APPROVAL THE CONTRACTOR <br />SHALL SUBMIT SIGNED AND SEALED DOCUMENTS TO THE AHJ FOR REVIEW <br />AND APPROVAL. <br />E KEYNOTES <br />01 FIRE ALARM CONTROL PANEL (FACP), REFER TO CONTRACTOR'S FIRE <br />PROTECTION DRAWINGS <br />02 FIRE ALARM ANNUNCIATOR PANEL (FAAP), REFER TO CONTRACTOR'S <br />FIRE PROTECTION DRAWINGS <br />03 FIRE SPRINKLER RISER CLOSET, REFER TO CONTRACTOR'S FIRE <br />PROTECTION DRAWINGS <br />04 STANDPIPE / HOSE VALVE CONNECTION, REFER TO CONTRACTOR'S FIRE <br />PROTECTION DRAWINGS <br />05 FIRE EXTINGUISHER IN SEMI -RECESSED CABINET, REFER TO DETAILS, <br />GENERAL NOTES / LEGEND FOR MOUNTING REQUIREMENTS <br />06 ELEVATOR CONTROLLER CLOSET <br />07 ELEVATOR CONTROLLER <br />08 AREA OF REFUGE TWO-WAY COMMUNICATION SYSTEM, REFER TO <br />ELECTRICAL DRAWINGS <br />09 "NOT AN EXIT" SIGN, CONTRACTOR TO PROVIDE A 7"X10" DURABLE <br />SELF-ADHESIVE VINYL SIGN PER LIFE SAFETY PLANS <br />10 KNOX BOX FOR EMERGENCY ACCESS BY FIRE DEPARTMENT TO ALL <br />RESTRICTED ACCESS AREAS FOR THE PROJECT, CONTRACTOR SHALL <br />PROVIDE AND COORDINATE EXACT LOCATION WITH AHJ <br />11 EMERGENCY RESPONDER RADIO COVERAGE SYSTEM, CONTRACTOR <br />SHALL PROVIDE 2-HOUR RATED CHASE, CONDUIT, RATED BACKBOARD, <br />AND POWER PER OWNER'S CONSULTANT REQUIREMENTS <br />LEGEND <br />— , — DESIGNATES 1 HR FIRE RATING FOR ADJACENT <br />WALL <br />-2-2 -2-2- DESIGNATES 2 HR FIRE RATING FOR ADJACENT <br />WALL <br />SEMI -RECESSED FIRE EXTINGUISHER IN CABINET, <br />Ito REFER TO GENERAL NOTES <br />DESIGNATES DOOR IS NOT AN EXIT <br />4 FLOOR OCCUPANCY (GROSS UNIT / SQUARE <br />FOOTAGE) USING STAIRS (TOTAL / NUMBER OF <br />120 STAIRS) <br />100 ROOM AREA (IN SF) <br />OCCUPANT LOAD FACTOR <br />2 OCCUPANT LOAD (PERSONS) <br />3 EGRESS LOAD (PERSONS) <br />32 REQUIRED EXIT WIDTH PER CODE <br />2 PROVIDED EXIT WIDTH <br />STARTING POINT <br />D=120' <br />TOTAL DISTANCE TO GRADE. LEVEL <br />PATH OF TRAVEL <br />3FORUME <br />ro <br />a <br />Y <br />ARCHITECTURE & <br />a <br />ED INTERIOR DESIGN, INC. <br />C <br />c <br />rn <br />U) <br />237 S. Westmonte Drive, Suite 220 <br />`o <br />Altamonte Springs, FL 32714 <br />C 407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />09/16/2022 <br />Karen V McIntyre <br />AR0017018 <br />SET DISTRIBUTIONS: <br />11/24/21 100% DD Set <br />_12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />0 SHEET REVISIONS: <br />PROJECT NO. 4097 <br />Building Type I - <br />Life Safety Plans <br />Building T <br />p I Fir-qt Flnnr I ifr gafn_tx/ Plan <br />1 /16" = 1'-0" <br />Al. 11 <br />