Laserfiche WebLink
GENERAL CODE REQUIREMENTS APARTMENTS <br />AUTHORITY HAVING JURISDICTION CODE COMPLIANCE: RESIDENTIAL BUILDINGS BUILDING AREA TABLE: RESIDENTIAL BUILDINGS <br />ZEPHYRHILLS, FL BUILDING DEPARTMENT (813) 780-0020 <br />REFER TO SHEET A2.01 FOR COMPLETE AREA CALCULATIONS <br />OCCUPANCY TYPE: SINGLE OCCUPANCY MULTISTORY BUILDING (GROUP R-2 OCCUPANCY) <br />PROJECT INFORMATION <br />CONSTRUCTION TYPE: V-A <br />FIRE SPRINKLER PROVIDED: NFPA 13R SYSTEM PER FBC-B 903.3.1.2. <br />5 RESIDENTIAL BUILDING(S) 4-STORY WOOD FRAME WITH EXTERIOR LOAD BEARING WALLS <br />BUILDING AREA AND HEIGHT LIMITATION <br />1 CLUBHOUSE BUILDING 1-STORY EXTERIOR LOAD BEARING MASONRY WALLS <br />ALLOWED PROPOSED <br />1 POOL PAVILION 1-STORY CMU COLUMNS & WOOD FRAME WALLS <br />BUILDING HEIGHT (FBC-B 504.3) <br />60'-0" 5V-10" <br />1 TRASH ENLOSURE w MAINTENENCE 1-STORY MASONRY WALLS <br />MAX NUMBER OF STORIES (FBC-B 504.4) <br />4 4 <br />MAXIMUM AREA FOR A SINGLE STORY (FBC-B 506.2) Per Calculation. <br />18,480 SF 15,337 SF <br />■ BUILDING CODES <br />MAXIMUM BUILDING AREA (FBC-B 506.2) Per Calculation. <br />73,920 SF 60,754 SF <br />FLORIDA BUILDING CODE -ACCESSIBILITY (FBC-A) SEVENTH EDITION (2020) <br />FIRE PROTECTION (FBC-B TABLE 601 & 602): <br />FLORIDA BUILDING CODE - BUILDING (FBC-B) SEVENTH EDITION (2020) <br />STRUCTURAL FRAME <br />1 HR <br />1 HR <br />FLORIDA BUILDING CODE - ENERGY CONSERVATION (FBC-EC) SEVENTH EDITION (2020) <br />EXTERIOR BEARING WALLS <br />1 HR <br />1 HR <br />FLORIDA BUILDING CODE - EXISTING BUILDING (FBC-EB) SEVENTH EDITION (2020) <br />INTERIOR BEARING WALLS <br />1 HR <br />1 HR <br />FLORIDA BUILDING CODE - FUEL GAS (FBC-FG) SEVENTH EDITION (2020) <br />EXTERIOR NON -BEARING WALLS <br />0 HR <br />0 HR <br />FLORIDA BUILDING CODE - MECHANICAL (FBC-M) SEVENTH EDITION (2020) <br />INTERIOR NON -BEARING WALLS <br />0 HR <br />0 HR <br />FLORIDA BUILDING CODE - PLUMBING (FBC-P) SEVENTH EDITION (2020) <br />FLOOR CONSTRUCTION <br />1 HR <br />1 HR <br />FLORIDA BUILDING CODE - RESIDENTIAL (FBC-R) SEVENTH EDITION (2020) <br />ROOF CONSTRUCTION <br />1 HR <br />1 HR <br />FLORIDA FIRE PREVENTION CODE (FFPC) SEVENTH EDITION (2020) <br />NATIONAL ELECTRICAL CODE (NEC) 2017 EDITION <br />DWELLING UNIT SEPARATION <br />LOCAL ORDINANCES AS APPLICABLE <br />WALLS (FBC-B 708) <br />1 HR <br />1 HR <br />FLOOR / CEILING ASSEMBLY (FBC-B 711) <br />1 HR <br />1 HR <br />FLORIDA THRESHOLD BUILDING <br />ROOF / CEILING ASSEMBLY (FBC-B711) <br />1 HR <br />1 HR <br />ELEVATOR SHAFT ENCLOSURE (FBC-B 713.4) <br />2 HR <br />2 HR <br />THIS PROJECT CONTAINS THRESHOLD BUILDING(S). A THRESHOLD BUILDING, IN ACCORDANCE WITH FLORIDA <br />EXIT ACCESS STAIRWAYS (FBC-B 713.4) <br />2 HR <br />2 HR <br />STATUTE, IS ANY BUILDING WHICH IS GREATER THAN 3 STORIES OR 50 FEET IN HEIGHT, OR WHICH HAS AN <br />CORRIDORS (FBC-B 1020.1) <br />1 HR <br />1 HR <br />ASSEMBLY OCCUPANCY CLASSIFICATION THAT EXCEEDS 5,000 SQUARE FEET IN AREA AND AN OCCUPANT <br />CONTENT OF GREATER THAN 500 PERSONS. FOR THRESHOLD INSPECTION PLAN, SEE STRUCTURAL DOCUMENTS. <br />INTERIOR FINISHES: RESIDENTIAL BUILDINGS <br />TO THE BEST OF THE ARCHITECTS KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE <br />MINIMUM BUILDING CODES AND THE APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL <br />GROUP R-1(SPRINKLERED) <br />AUTHORITY IN ACCORDANCE WITH FBC BUILDING, SECTION 110.8 THRESHOLD BUILDING AND FLORIDA STATUTES <br />CONTRACTOR SHALL COMPLY WITH THE MORE STRINGENT REQUIREMENT WHERE REQUIREMENTS OVERLAP. <br />CHAPTER 633. <br />DESCRIPTION FBC-B TABLE 803.11 FFPC 30.3.3.2 -NEW PROPOSED <br />FLORIDA WIND-BORNE DEBRIS REGION <br />(GROUP R-2 SPRINKLERED) APARTMENT BUILDINGS <br />ALLOWED <br />ALLOWED <br />TO THE BEST OF THE ARCHITECTS KNOWLEDGE, THIS PROJECT IS NOT LOCATED IN A WIND-BORNE DEBRIS <br />INT EXIT STAIRWAYS, RAMPS C <br />A <br />A <br />REGION AS DEFINED IN CHAPTER 2 OF THE FBC. REFER TO STRUCTURAL DRAWINGS FOR WIND LOADING <br />& PASSAGEWAYS <br />REQUIREMENTS. OPENING PROTECTIONS ARE NOT REQUIRED TO COMPLY WITH FBC 1609.1.2. <br />CORRIDORS & ENCLOSURE C <br />A OR B <br />A <br />FOR EXIT ACCESS <br />ACCESSIBILITY REQUIREMENTS <br />ROOMS & ENCLOSED C <br />A, B, OR C <br />C <br />1. IN BUILDINGS WITH FOUR OR MORE DWELLING UNITS AND AT LEAST ONE ELEVATOR, ALL DWELLING UNITS AND <br />SPACES <br />ALL PUBLIC AND COMMON USE AREAS ARE SUBJECT TO THE DESIGN AND CONSTRUCTION REQUIREMENTS OF <br />THE FAIR HOUSING ACT (FHA). IN BUILDINGS WITH FOUR OR MORE UNITS AND NO ELEVATOR, ALL GROUND <br />FLOOR UNITS AND PUBLIC AND COMMON USE AREAS ARE SUBJECT TOFHA'SDESIGN AND CONSTRUCTION <br />OW-1 IFE SAFETY COMPLIANCE: RESIDENTIAL BUILDINGS <br />REQUIREMENTS. SUCH REQUIREMENTS ARE BASED ON THE FHA DESIGN MANUAL, REVISED AS <br />OF 1998. THESE UNITS ARE DESIGNATED "ADAPTABLE UNITS." MULTI -STORY UNITS IN BUILDINGS WITHOUT <br />REFER TO SHEETS A1.11 THROUGH A1.21 FOR LIFE SAFETY PLANS <br />ELEVATORS, CARRIAGE UNITS, AND UNITS IN BUILDINGS WITH LESS THAN FOUR UNITS ARE NOT COVERED BY <br />FHA. <br />UNIT AREA TABLE <br />2. COMMON USE AREAS, AS DEFINED BY FHA, ARE SPACES AND FACILITIES USED EXCLUSIVELY BY TENANTS AND <br />THEIR GUESTS AND SHALL COMPLY WITH BOTH THE FHA AND APPLICABLE REFERENCES TO ICC/ANSI <br />Al 17.1-2003, WHICH IS A SAFE HARBOR RECOGNIZED BY FHA. IF A LATER EDITION OF ICC/ANSI Al 17.1 IS LISTED <br />IN THE CODE COMPLIANCE SECTION OF THESE DOCUMENTS AS MAY BE REQUIRED BY BUILDING CODE, STATE <br />OR MUNICIPALITY, THEN THE APPLICABLE REQUIREMENTS PROVIDING A HIGHER LEVEL OF ACCESSIBILITY <br />SHALL BE FOLLOWED. <br />3. PUBLIC USE AREAS, AS DEFINED BY FHA, ARE SPACES THAT ARE MADE AVAILABLE TO THE GENERAL PUBLIC <br />AND SHALL COMPLY WITH THE FHA AND THE AMERICANS WITH DISABILITY ACT (ADA) 2010 STANDARDS FOR <br />ACCESSIBLE DESIGN, AS CONSTITUTED WITH AMENDMENTS IN THE 2017 FLORIDA ACCESSIBILITY CODE FOR <br />BUILDING CONSTRUCTION (FAC). <br />4. TO THE BEST OF THE ARCHITECT'S KNOWLEDGE, SUCH PUBLIC USE AREAS WITHIN THE BUILDINGS DESCRIBED <br />BY THESE DOCUMENTS INCLUDE: PRIMARY CLUBHOUSE ENTRANCE, CLUBHOUSE LOBBY/FOYER, LEASING <br />OFFICE, PUBLIC RESTROOMS, POOL AREA, POOL GATES, AND THE ACCESSIBLE ROUTE CONNECTING THE <br />SAME. <br />N <br />ca <br />U <br />UNIT TYPE <br />UNIT <br />NAME <br />UNIT AREA IN SF <br />TOTAL UNIT <br />AREA IN SF <br />UNIT TOTAL <br />BYNAME <br />UNIT TOTAL <br />BY TYPE <br />% UNIT <br />TYPE <br />A/C <br />NON -A/C <br />GARAGE <br />1 BED / 1 BATH <br />Al <br />716 <br />83 <br />0 <br />799 <br />72 <br />117 <br />46.43% <br />1 BED / 1 BATH <br />A2 <br />797 <br />80 <br />0 <br />877 <br />40 <br />1 BED / 1 BATH <br />A3 <br />724 <br />3 <br />0 <br />727 <br />5 <br />2 BED / 2 BATH <br />131 <br />1053 <br />98 <br />0 <br />1151 <br />28 <br />123 <br />48.81 % <br />2 BED 12 BATH <br />B2 <br />1061 <br />80 <br />0 <br />1141 <br />40 <br />2 BED / 2 BATH <br />B3 <br />1117 <br />84 <br />0 <br />1201 <br />28 <br />2 BED /2 BATH <br />B4 <br />1039 <br />82 <br />0 <br />1121 <br />15 <br />2 BED / 2 BATH <br />B5 <br />1099 <br />81 <br />0 <br />1180 <br />12 <br />3 BED / 2 BATH <br />C1 <br />1289 <br />66 <br />0 <br />1355 <br />12 <br />12 <br />0.05% <br />TOTAL UNITS IN PROJECT <br />252 <br />100.00% <br />NOTE 1: THIS INFORMATION SHALL NOT BE USED FOR CONDOMINIUM DOCUMENTS <br />NOTE 2: UNIT AREAS LISTED ARE FROM OUTSIDE TO OUTSIDE OF EXTERIOR WALL OR UNIT PERIMETER WALL, <br />AND TO CENTERLINE OF TENANT WALLS (WHERE APPLICABLE) <br />NOTE 3: 251 LEASEABLE UNITS & 1 DEDICATED MODEL UNIT <br />RESIDENTIAL BLDG TYPE <br />1 <br />II <br />BLDG # ON SITE <br />3, 4, 5 <br />1,2 <br /># UNITS / BLDG TYPE <br />52 (3 TOTAL ON SITE) <br />48 (2 TOTAL ON SITE) <br />A/C <br />NON -A/C <br />GROSS <br />A/C <br />NON -A/C <br />GROSS <br />1ST FLOOR <br />13,650 <br />1,686 <br />15,336 <br />12,652 <br />1,641 <br />14,293 <br />2ND FLOOR <br />13,647 <br />1,485 <br />15,132 <br />12,650 <br />1,439 <br />14,089 <br />3RD FLOOR <br />13,647 <br />1,485 <br />15,132 <br />12,650 <br />1,439 <br />14,089 <br />4TH FLOORS <br />13,647 <br />1,485 <br />15,132 <br />12,650 <br />1,439 <br />14,089 <br />BUILDING TOTAL <br />54,591 <br />6,141 <br />60,732 <br />50,602 <br />5,958 <br />56,560 <br />QUANTITY ON SITE <br />3 <br />2 <br />TOTAL SF ON SITE <br />182,196 <br />113,120 <br />RESIDENTIAL BLDG TOTAL <br />295,316 <br />RESIDENTIAL BUILDING TYPE DIAGRAMS <br />BUILDING TYPE 1(3 ON SITE) <br />16 A1-1 BED / 1 BATH <br />8 A2 -1 BED / 1 BATH <br />1 A3 -1 BED/1 BATH C1 B5 B2 B2 Al B3 <br />4 B1- 2 BED / 2 BATH <br />8 1324 2 BED/2 BATH A2 Al Al Al B4 61 A2 <br />4 B3 - 2 BED 12 BATH <br />3 B4 - 2 BED / 2 BATH C1 B5 B2 B2 Al B3 <br />4 B5 - 2 BED / 2 BATH <br />4 C1- 3 BED / 2 BATH I /,42 //A1 -'Al ,�-'Al ,-' B4 i 131 <br />52 TOTAL UNITS <br />C1 <br />B5 <br />B2 <br />B2 Al B3 <br />A2 <br />Al <br />Al <br />Al',,-'B4 <br />61 <br />C1 <br />B5 <br />B2 <br />B2 Al B3 <br />A2 <br />Al <br />Al <br />Al A3 <br />B1 <br />TAIRS <br />ENTRY <br />TAIRS <br />BUILDING TYPE II (2 ON SITE) <br />12 Al -1 BED / 1 BATH <br />8 A2-1 BED/1 BATH <br />B3 <br />Al <br />B2 <br />B2 Al B3 <br />1 A3 -1 BED / 1 BATH <br />8 B1- 2 BED / 2 BATH <br />A2 <br />g1 <br />B4 <br />Al B1 <br />A2 <br />8 132 - 2 BED/2 BATH <br />8 133 - 2 BED 12 BATH <br />3 134 - 2 BED/2 BATH <br />g3 <br />Al <br />B2 <br />B2 All B3 <br />48 TOTAL UNITS <br />A2 <br />B1 <br />B4 <br />Al B1 <br />B3 Al B2 B2 1 B3 <br />A2 B1 B4 Al B1 <br />B3 Al B2 B2 1 B3 <br />A2 B1 A3 Al B1 <br />0 UNIT TYPE DIAGRAMS <br />UNIT Al <br />1 BED / 1 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 36'-10" <br />UNIT 61 <br />2 BED / 2 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 43'-0" <br />UNIT B4 <br />2 BED / 2 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 43'-0" <br />RS <br />UNIT A2 <br />1 BED / 1 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 36-10" <br />UNIT B2 <br />2 BED / 2 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 53-0" <br />UNIT B5 <br />2 BED / 2 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 4Y-7" <br />UNIT A3 <br />1 BED / 1 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 34'-1 V <br />UNIT B3 <br />2 BED / 2 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 4V-7" <br />UNIT C1 <br />3 BED / 2 BATH <br />TRAVEL DISTANCE WITHIN <br />DWELLING UNIT = 42'-10" <br />m <br />a <br />FORUMN <br />ARCHITECTURE & <br />CL <br />INTERIOR DESIGN, INC. <br />I <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />02/17/2022 <br />Karen \/ Mr.IntvrP <br />SET DISTRIBUTIONS: <br />11/24/21 100% DOD Set <br />12123/21 Owner Review Set <br />02117/22 Permit Set <br />A SHEET REVISIONS: <br />PROJECT NO. 4097 <br />Building & Unit Areas, <br />Diagrams & Project <br />Information <br />A1.02 <br />