Laserfiche WebLink
M <br />I <br />ABBREVIATION <br />LEGEND <br />Pounds Per Linear Foot <br />1. <br />FIRE PROTECTION <br />BUILDINGS SHALL BE PROVIDED WITH A FIRE SPRINKLER SYSTEM AS REQUIRED BY THE BUILDING CODE, <br />1. <br />GENERAL DATA <br />CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY <br />AC <br />Air Condition(edler) <br />FPM <br />Feet Per Minute <br />PLF <br />AFF <br />Above Finish Floor <br />FIR <br />Fire Rated <br />PLYWD <br />Plywood <br />DESIGNED AND INSTALLED TO COMPLY WITH THE APPLICABLE NFPA STANDARD. <br />ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO <br />AHJ <br />Authority Having Jurisdiction <br />FRCP <br />Fiber Reinforced Cement <br />PRE -EN <br />Pre-engineered <br />PROCEEDING WITH THE WORK. <br />AHU <br />Air Handler Unit <br />Plaster <br />PSF <br />Pounds Per Square Foot <br />2. <br />THE CONTRACTOR'S FIRE PROTECTION ENGINEER SHALL BE THE "ENGINEER OF RECORD" FOR THE FIRE <br />ALT <br />Alternate <br />FRP <br />Fiber Reinforced Panel <br />PSI <br />Pounds Per Square Inch <br />PROTECTION SYSTEM AND SHALL PREPARE COMPLETE AND FINAL FIRE PROTECTION DESIGN DOCUMENTS <br />2. <br />DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION <br />ALUM <br />Aluminum <br />FRT <br />Fire Retardant Treated <br />P-T <br />Post Tension <br />WITH HYDRAULIC CALCULATIONS, SIGNED AND SEALED, AS REQUIRED AND DEFINED BY THE AHJ AND SHALL <br />OF BUILDING COMPONENTS. DRAWINGS WORK IN CONJUNCTION WITH SPECIFICATIONS, PRODUCT <br />APT <br />Apartment <br />FT <br />Foot / Feet <br />PT <br />Pressure Treated Wood <br />SUBMIT REQUIRED DOCUMENTATION TO THE ARCHITECT FOR GENERAL REVIEW. UPON APPROVAL, THE <br />MANUFACTURER'S RECOMMENDATIONS, AND INDUSTRY STANDARDS REGARDING EXACT REQUIREMENTS OF <br />BALC <br />Balcony <br />FTG <br />Footing <br />PTAC <br />Package Terminal AC <br />CONTRACTOR SHALL SUBMIT SIGNED/SEALED DOCUMENTS TO THE AHJ FOR REVIEW AND APPROVAL. <br />PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND CLASSIFICATIONS. <br />BDA <br />Bi-Directional Amplification <br />FND <br />Foundation <br />PTD <br />Painted <br />3. <br />ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK <br />System <br />FOB <br />Face of Beam <br />PVC <br />Poly Vinyl Chloride <br />■ PAINTING <br />ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS AND SHALL COORDINATE AND SEQUENCE THEIR <br />BFF <br />Below Finish Floor <br />FOS <br />Face of Stud <br />QT <br />Quarry Tile <br />WORK WITH OTHER TRADES. DO NOT BASE SCOPE OF WORK SOLELY ON A REVIEW OF THE SHEETS <br />BLDG <br />Building <br />GA <br />Gauge <br />RAD <br />Radius <br />1. <br />REFER TO, AND COORDINATE WITH, INTERIOR FINISH SCHEDULE AND SEPARATE DOCUMENTS PREPARED BY <br />TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. <br />BLKG <br />BM <br />Blocking <br />Beam <br />GALV <br />GAR <br />Galvanized <br />Garage <br />RCP <br />REF <br />Reflected Ceiling Plan <br />Reference <br />INTERIOR DESIGNER AND/OR OWNER, WHEN APPLICABLE, FOR SPECIFIC PAINT SELECTIONS, COLORS, FINISH <br />4. <br />DO NOT SCALE DRAWINGS. USE ONLY PRINTED DIMENSIONS. <br />TEXTURES, AND OTHER REQUIREMENTS. <br />BR <br />Bedroom <br />GC <br />General Contractor <br />REFRIG <br />Refrigerator <br />5. <br />THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING AND <br />BRG <br />Bearing <br />GLS <br />Glass <br />REINF <br />Reinforce(edling) <br />2. <br />ALL EXTERIOR VENTS AND EQUIPMENT THAT ARE VISIBLE ON EXTERIOR OF BUILDING SHALL BE PAINTED A <br />PROPOSED TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES <br />BRZWY <br />Breezeway <br />GLZ <br />Glazing <br />REQD <br />Required <br />COLOR TO MATCH THE ADJACENT SURFACE, UNO. <br />PRIOR TO PROCEEDING WITH THE PROJECT. <br />BTM <br />Bottom <br />GYPBD <br />Gypsum Board <br />RM <br />Room <br />B.O. <br />Bottom of <br />HC <br />Hollow Core <br />RO <br />Rough Opening <br />3. <br />ALL COLOR TRANSITIONS SHALL BE ON THE INSIDE CORNERS, UNLESS OTHERWISE SPECIFIED IN COLOR <br />6. <br />THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, <br />CAB <br />Cabinet <br />HB <br />Hose Bibb <br />RS <br />Rough Sawn <br />STUDY ELEVATIONS. <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS AND <br />CALC <br />Calculation <br />HDR <br />Header <br />RSC <br />Rough Sawn Cedar <br />4. <br />CONTACT THE OWNER OR ARCHITECT IF THERE ARE ANY QUESTIONS PRIOR TO PAINTING. <br />PROGRAMS, THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PROPER INSTALLATION AND APPLICATION <br />CER <br />Ceramic <br />HDW <br />Hardware <br />SAN <br />Sanitary <br />OF ALL MATERIALS AND PRODUCTS AS REQUIRED PER THE MANUFACTURER'S WRITTEN REQUIREMENTS, <br />CFM <br />Cubic Feet Per Minute <br />HORIZ <br />Horizontal <br />SC <br />Solid Core <br />5. <br />PREPARATION AND APPLICATION OF PRIMER AND FINISH PAINT PRODUCTS SHALL BE DONE PER THE <br />QUALITY CONTROL, AND FOR COORDINATING ALL PORTIONS OF THE WORK. <br />CFS <br />Clear Floor Space <br />HR <br />Hour <br />SCH <br />Schedule <br />MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />CIP <br />Cast In Place <br />HT <br />Height <br />SEP <br />Separation <br />7. <br />DIMENSIONS SHOWN ARE TO FACE OF THE SPECIFIED BUILDING MATERIAL; (CONCRETE, CMU, WOOD/METAL <br />CJ <br />Control Joint <br />HVAC <br />Heating, Venting & AC <br />SF <br />Square Feet <br />6. <br />ALL GYPSUM BOARD FINISHED SURFACES IN CONDITIONED AND NON -CONDITIONED SPACES SHALL BE <br />STUD, ETC.), AND TO CENTERLINE OF OPENINGS, UNO. <br />CL <br />Center Line <br />HW <br />Hot Water <br />S/F <br />Storefront <br />PAINTED AS SPECIFIEDUNO. <br />, <br />8. <br />IF REQUIRED BY THE AHJ, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND SUBMITTING <br />CLG <br />Ceiling <br />IBC <br />International Building Code <br />SGD <br />Sliding Glass Door <br />PRODUCT APPROVAL DOCUMENTATION TO THE AHJ IN THE FORM REQUIRED BY THE AHJ. THE CONTRACTOR <br />CLOS <br />Closet <br />ID <br />Interior Design <br />SHT <br />Sheet <br />CABINETS & COUNTERTOPS <br />MUST FIRST SUBMIT THE PRODUCT DOCUMENTATION TO THE ARCHITECT FOR REVIEW AND APPROVAL <br />CLR <br />Clear <br />IDF <br />Intermediate Distribution <br />SHTG <br />Sheathing <br />BEFORE SUBMITTING TO THE AHJ. <br />CMU <br />Concrete Masonry Unit <br />Frame <br />Sl <br />Square Inches <br />1. <br />VANITY BASE CABINETS SHALL BE 21" DEEP WITH 22" TOPS, UNO, REFER TO INTERIOR ELEVATIONS FOR <br />COL <br />Column <br />IIC <br />Impact Insulation Class <br />SIM <br />Similar <br />HEIGHTS, COUNTERTOP OVERHANG AT THE EXPOSED END OF THE VANITY CABINET SHALL NOT BE MORE <br />9, <br />ANY ERRORS, OMISSIONS OR INCONSISTENCIES DISCOVERED IN THE DOCUMENTS, OR ANY VARIATION OR <br />CONC <br />Concrete <br />IN <br />Inch / Inches <br />SOG <br />Slab On Grade <br />THAN V. <br />AMBIGUITIES BETWEEN THESE DRAWINGS AND ACTUAL SITE AND CONSTRUCTION CONDITIONS AND/OR <br />COND <br />Condenser / Condensate <br />INST <br />Installation <br />SP <br />Spring Point <br />REQUIREMENTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IF A DISCREPANCY IS FOUND IN <br />CONT <br />Continuous <br />INSUL <br />Insulation(ed) <br />SPEC <br />Specifications <br />2. <br />KITCHEN BASE CABINETS TO BE 24" DEEP WITH 25" TOPS, LINO. UPPER CABINETS TO BE 12" DEEP. REFER TO <br />THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING, <br />CORR <br />Corridor <br />INT <br />Interior <br />SPF <br />Spruce -Pine -Fur <br />INTERIOR ELEVATIONS FOR HEIGHTS. <br />10. <br />ANY ON SITE OBSERVATIONS BY THE ARCHITECT SHALL BE IN THE FORM OF RANDOM OBSERVATIONS ONLY <br />CID <br />Cement Plaster <br />JB <br />Junction Box <br />SQ <br />Square <br />q <br />3. <br />CONTRACTOR OR CABINET MANUFACTURER TO FIELD VERIFY FINISH TO FINISH DIMENSIONS PRIOR TO <br />AND DO NOT RELIEVE THE CONTRACTOR FROM HIS RESPONSIBILITY OF BUILDING ACCORDING TO THE <br />CPT <br />Carpet <br />JST <br />Joist <br />SS <br />Stainless Steel <br />FABRICATION OF CABINETS. <br />APPROVED CONSTRUCTION DOCUMENTS, IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS, AND <br />CT <br />Ceramic Tile <br />JT <br />Joint <br />STC <br />Sound Transmission Class <br />AS REQUIRED BY THE AHJ. <br />CW <br />Cold Water <br />KDAT <br />Kiln Dried After Treatment <br />STD <br />Standard <br />4. <br />ALL EXPOSED FINISHED SURFACES SHALL MATCH THE COLOR AND FINISH OF THE ADJACENT FINISHED <br />D <br />Dryer <br />KIT <br />Kitchen <br />STL <br />Steel <br />SURFACE; INCLUDING EXPOSED CABINET ENDS SHALL MATCH CABINET FRONT, <br />11. <br />ALL MATERIALS IN DIRECT CONTACT WITH OTHER MATERIALS SHALL BE COMPATIBLE AND COMPLY WITH THE <br />DAS <br />Distributed Antenna System <br />LAM <br />Laminate <br />STO <br />Storage <br />5. <br />ALL WALLS / PARTITIONS SUPPORTING WALL HUNG CABINETS SHALL HAVE FRAMING WITH 2 X 4 STUDS <br />MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />DIA <br />DIM <br />Diameter <br />Dimension <br />LAV <br />LF <br />Lavatory <br />Linear Feet <br />SIN <br />SW <br />Shear Wall <br />Symmetrical <br />AT 16" O.C. MAX. OR 2 X 6 STUDS AT 24" O.C. MAX., LINO. <br />12. <br />ALL MATERIALS AND PRODUCTS INDICATED ON THE DRAWINGS SHALL BE AS SPECIFIED, UNO. SEE PROJECT <br />DN <br />Down <br />LGMF <br />Light Gauge Metal Framing <br />SYP <br />Southern Yellow Pine <br />MANUAL SPECIFICATIONS. <br />DIN <br />Dining <br />LIN <br />Linen <br />T&B <br />Top & Bottom <br />SOUND TRANSMISSION CLASS <br />13. <br />THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND INSTALL AN IDENTIFYING SYMBOL ON <br />DP <br />Deep <br />LR <br />Living Room <br />T&G <br />Tongue & Groove <br />STRUCTURES CONSTRUCTED WITH A LIGHT -FRAME TRUSS COMPONENT IN A MANNER SUFFICIENT TO COMPLY <br />DR <br />Door <br />LT <br />Light <br />TB <br />Towel Bar <br />1. <br />COMPLY WITH BUILDING CODE FOR SOUND TRANSMISSION CONTROL REQUIREMENTS. UNLESS OTHERWISE <br />WITH THE STATE OF FLORIDA FIRE MARSHAL'S OFFICE IN ACCORDANCE WITH FLORIDA STATUTE 633.027, PER <br />DS <br />Down Spout <br />MAX <br />Maximum <br />TEMP <br />Tempered <br />INDICATED, MAINTAIN RATINGS OF AT LEAST 50 STC AND 50 IIC BETWEEN DWELLING UNITS AND BETWEEN <br />THE REQUIREMENTS OF THE FLORIDA ADMINISTRATIVE CODE RULE 69A-60.0081, AND AS DETERMINED BY THE <br />DTL <br />Detail <br />MDF <br />Main Distribution Frame <br />THK <br />Thick <br />DWELLING UNITS AND COMMON SPACES. PENETRATIONS, EDGES, AND JOINTS MUST BE TREATED TO <br />AHJ. <br />DW <br />Dishwasher <br />MECH <br />Mechanical <br />TPD <br />Toilet Paper Dispenser <br />MAINTAIN REQUIRED RATINGS. <br />DWG <br />Drawing <br />MEM <br />Membrane <br />TPH <br />Toilet Paper Holder <br />EA <br />Each <br />MEP <br />MECH, ELEC, PLMG <br />T.O. <br />Top of <br />■ SITE WORK & FOUNDATION <br />ELEC <br />Electric(al) <br />MFR <br />Manufacturer(ed) <br />TOS <br />Top of Slab <br />INSULATION <br />ELEV <br />Elevation <br />MIN <br />Minimum <br />TOFD <br />Top of Floor Deck <br />1. <br />FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR ACTUAL VALUE AS SPECIFIED <br />ENG <br />Engineer(ed) <br />MIR <br />Mirror <br />TRS <br />Truss <br />1. <br />INSULATION SHALL COMPLY WITH THE BUILDING CODE. PROVIDE INSULATING MATERIALS WHICH COMPLY <br />BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS, FOUNDATIONS AND SLABS ARE DESIGNED <br />EOP <br />Edge of Paver <br />MISC <br />Miscellaneous <br />TS <br />Tube Steel <br />WITH REQUIREMENTS INDICATED INCLUDING R-VALUES AND THAT MEET OR EXCEED THE REQUIREMENTS OF <br />TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE SOILS. A CERTIFIED SOILS <br />EOS <br />Edge of Slab <br />MPH <br />Miles Per Hour <br />TYP <br />Typical <br />THE STATE ENERGY EFFICIENCY CODE. <br />ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE WITH SUBSURFACE SOIL <br />EQ <br />Equal <br />MR <br />Moisture Resistant <br />UL <br />Underwriters Laboratory <br />2. <br />INSTALL INSULATION PER MANUFACTURER'S WRITTEN INSTRUCTIONS APPLICABLE TO PRODUCTS AND <br />INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT FOOTINGS SHOWN HERE <br />EQUIV <br />Equivalent <br />MTD <br />Mounted <br />UNO <br />Unless Noted Otherwise <br />ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR REVISED DESIGNS. <br />EWC <br />Electric Water Cooler <br />MTL <br />Metal <br />VC <br />Vinyl Covered <br />APPLICATIONS INDICATED. <br />Z. <br />THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED SITE <br />EXP <br />Expansion <br />NFA <br />Net Free Area <br />VCT <br />Vinyl Composite Tile <br />3. <br />CONCEALED INSTALLATIONS SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A <br />UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED <br />EXT <br />Exterior <br />NUM/# <br />NOM <br />Number <br />Nominal <br />VER <br />Verify <br />SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450. <br />AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL, <br />EXTG <br />FACP <br />Existing <br />Fire Alarm Control Panel <br />NRC <br />Noise Reduction Class <br />VERT <br />VE <br />Vertical <br />Verify In Field <br />STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY <br />FB <br />Blocking <br />Fire Blocking <br />NT <br />NTS <br />Noise Scale <br />VLT <br />Vault <br />GYPSUM BOARD <br />COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL <br />FBC <br />Florida Building Code <br />On Center <br />VWC <br />Vinyl Wall Covering <br />CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY, <br />FD <br />Floor Drain <br />OCC <br />Occupancy I Occupant <br />W <br />Washer <br />1. <br />ALL INTERIOR NON -RATED WALL CONSTRUCTION TO HAVE 1/2" MINIMUM REGULAR GYPSUM BOARD, UNO. <br />3. <br />REFER TO CIVIL ENGINEER'S SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES, <br />FE <br />Fire Extinguisher <br />OFW <br />Outside Face of Wall <br />W/ <br />With <br />2. <br />ALL INTERIOR FIRE -RATED WALL CONSTRUCTION TO HAVE 5/8" FIRE -RATED GYPSUM BOARD, LINO. <br />FLOOR ELEVATIONS, UTILITIES, DRAINAGE, AND ALL INFORMATION RELATED TO THE PROJECTS ON -SITE <br />FF <br />Finished Floor <br />OH <br />Overhang <br />W/D <br />Washer/Dryer Combination <br />DEVELOPMENT AND OFF -SITE REQUIREMENTS, IF APPLICABLE. <br />FFE <br />Finished Floor Elevation <br />OS <br />Outside of Stud <br />W/0 <br />Without <br />3. <br />GYPSUM BOARD INSTALLATION SHALL BE IN CONFORMANCE WITH THE GYPSUM ASSOCIATION'S <br />FIN <br />Finish(ed) <br />OSB <br />Oriented Strand Board <br />WC <br />Water Closet <br />RECOMMENDED PRACTICES FOR THICKNESS, ATTACHMENT, TAPING, FINISHING AND STUD SPACING. PROVIDE <br />4. <br />REFER TO LANDSCAPE ARCHITECT'S AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL <br />FJS <br />Finger Jointed Studs <br />PAN <br />Pantry <br />WD <br />Wood <br />TEXTURE FINISH AS SPECIFIED OR DIRECTED BY THE INTERIOR DESIGNER, IF APPLICABLE, AND APPROVED BY <br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES, <br />FLR <br />Floor <br />PKG <br />Package <br />WDW <br />Window <br />THE OWNER. <br />ETC. <br />FM <br />Field Measure <br />PLAM <br />Plastic Laminate <br />WIC <br />Walk In Closet <br />4. <br />GYPSUM BOARD USED IN A FIRE RATED ASSEMBLY SHALL CONFORM EXACTLY TO THE REQUIREMENTS OF THE <br />5. <br />CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL <br />FOM <br />Face of Masonry /Concrete <br />PLB <br />Plumb <br />WH <br />Water Heater <br />ASSEMBLY LISTED. <br />NOT BE LESS THAN 6 INCHES, UNO. <br />FP <br />Fire Protection <br />PLMG <br />Plumbing <br />SYMBOLS LEGEND <br />CENTERLINE OF BUILDING/OBJECT <br />OD D00 NUMBERED DOOR SYMBOLS <br />0,_0„ ELEVATION TARGET, INDICATES HGT AFF <br />D_ KEY NOTE WITH LEADER INDICATOR <br />R \ REVISION DELTA <br />Ct „ ,-0 TITLE MARKER <br />O LETTERED WINDOW SYMBOL <br />COMPLETE SECTION: <br />YA <br />X DETAIL NUMBER <br />LOCATION & DIRECTION OF CUT <br />.X SHEET ON WHICH DETAIL APPEARS <br />NOTE <br />PARTIAL SECTION: <br />X DETAIL NUMBER <br />LOCATION & DIRECTION OF CUT <br />AXAX SHEET ON WHICH DETAIL APPEARS <br />NOTE <br />A ELEVATION: <br />X DETAIL NUMBER <br />DETAIL DIVISION <br />SHEET ON WHICH DETAIL APPEARS <br />ASSEMBLY TAG: <br />W� L DESIGNATION <br />5. BASE FOR TILE: GLASS MAT WATER-RESISTANT GYPSUM BACKING PANELS, DISCRETE NONASBESTOS <br />FIBER -CEMENT INTERIOR SUBSTRATE SHEETS OR NONASBESTOS FIBER -MAT REINFORCED CEMENTITIOUS <br />BACKER UNITS IN COMPLIANCE WITH ASTM C 1178, C 1288 OR C 1325 AND INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS. <br />WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET <br />COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840 AND MANUFACTURER <br />RECOMMENDATIONS. REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER <br />WALL AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840. <br />6. ALL GYPSUM BOARD USED IN NON -CONDITIONED AND/OR EXTERIOR CONDITIONS TO BE EXTERIOR GRADE <br />GYPSUM SHEATHING BOARD, 5/8" THICK, UNO. AS AN ALTERNATE TO STANDARD GYPSUM SHEATHING, THE <br />CONTRACTOR MAY INSTALL A GLASS -MAT GYPSUM SHEATHING PRODUCT. PROVIDE FIRE -RATED EXTERIOR <br />GRADE GYPSUM SHEATHING BOARD AS REQUIRED FOR FIRE -RATED ASSEMBLIES. <br />7. CONTROL JOINTS TO BE INSTALLED PER GYPSUM ASSOCIATION GA-234 AND PER MANUFACTURER'S <br />RECOMMENDATIONS AND MINIMUM REQUIREMENTS. REFER TO THE PROJECT MANUAL SPECIFICATIONS, <br />DIVISION 09 GYPSUM BOARD, FOR ADDITIONAL INFORMATION. GYPSUM BOARD CONTROL JOINT LOCATIONS <br />ARE NOT SHOWN ON THE DRAWINGS, EXCEPT WHERE INCORPORATED AS A DESIGN ACCENT OR <br />ARCHITECTURAL FEATURE. PROPOSED GENERAL CONTROL JOINT LOCATIONS SHALL BE DETERMINED BY THE <br />CONTRACTOR AND THE CONTRACTOR SHALL HAVE THE OWNER REVIEW AND APPROVE PROPOSED <br />LOCATIONS PRIOR TO INSTALLATION, <br />8. WATER-RESISTANT GYPSUM BOARD SHALL BE USED FOR WALLS AND CEILINGS IN TUB AND SHOWER AREAS <br />ABOVE TILE SURFACES IN COMPLIANCE WITH ASTM C1396. <br />PIPE & TUBE RAILINGS <br />1. HANDRAILS AND GUARDS TO BE FABRICATED AS INDICATED ON THE DRAWINGS AND AS SPECIFIED, RAILING <br />FABRICATOR'S STATE REGISTERED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE FINAL DESIGN <br />AND PREPARATION OF THE SHOP DRAWINGS AND PROVIDE SIGNED AND SEALED COPIES AS REQUIRED. <br />2. PROVIDE SOLID STRUCTURAL REINFORCEMENT, (FRAMING, BLOCKING, ETC.), AS REQUIRED TO SECURELY <br />ATTACH HANDRAILS, GUARDRAILS, AND RAILING POSTS TO RESIST LINEAR AND CONCENTRATED LOADS AS <br />REQUIRED BY CODE. <br />3. GUARDS SHALL HAVE INTERMEDIATE PICKETS SUCH THAT A 4" DIAMETER SPHERE CANNOT PASS <br />THROUGH. BOTTOM RAIL SHALL REJECT PASSAGE OF 2" DIAMETER SPHERE. THE TRIANGULAR OPENINGS <br />FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL AT THE OPEN SIDE OF THE STAIRWAY SHALL BE OF A <br />MAXIMUM SIZE SUCH THAT A SPHERE OF 6" IN DIAMETER CANNOT PASS THROUGH THE OPENING. HEIGHT OF <br />GUARDS SHALL BE AS INDICATED ON THE DRAWINGS OR AS OTHERWISE REQUIRED BY CODE. <br />4. PROVIDE ALL REQUIRED ACCESSORIES, FITTINGS, AND ANCHORS AS NECESSARY FOR A COMPLETE <br />INSTALLATION. INSTALLATION SHALL COMPLY WITH APPLICABLE CODE REQUIREMENTS. FINISHES SHALL BE <br />AS INDICATED OR SPECIFIED, WHERE APPLICABLE, OR AS DIRECTED BY THE OWNER. <br />5. SEPARATE DISSIMILAR METALS WITH BUTYL RUBBER OR POLYPROPYLENE GASKET OR MASTIC COMPOUND. <br />6. INSTALL MULTI -POLYMER PLASTIC OR SIMILAR MATERIAL BEARING SHIM STRIPS, 1/8"THICK, BETWEEN THE <br />BOTTOM OF SURFACE MOUNTED METAL RAILING POST AND CONCRETE SURFACES. <br />DAS/BDA SYSTEMS FIRESTOP QUALITY ASSURANCE <br />PER NFPA 1:11,10, MINIMUM RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT COMMUNICATIONS SHALL BE <br />MAINTAINED AT A LEVEL DETERMINED BY THE AHJ AND NFPA 1221. A THIRD PARTY SHALL EVALUATE THE SIGNAL <br />STRENGTH AT THE COMPLETION OF CONSTRUCTION FOR CONFORMANCE WITH THE REQUIREMENTS. IF THE <br />SIGNAL STRENGTH IS NOT COMPLIANT, THE OWNER SHALL PROVIDE A RADIO COMMUNICATION ENHANCEMENT <br />SYSTEM OR OTHER MEANS REQUIRED TO COMPLY WITH THE REQUIREMENTS OF THE AHJ PRIOR TO THE FINAL <br />FIRE INSPECTION. IF A RADIO COMMUNICATION ENHANCEMENT SYSTEM IS REQUIRED, IT IS THE OWNER'S <br />RESPONSIBILITY TO PROVIDE THE NECESSARY CONSULTANTS TO DESIGN THE SYSTEM AND COORDINATION FOR <br />ALL ADDITIONAL REQUIREMENTS. <br />NFPA GRAB BARS <br />PER THE FLORIDA STATE FIRE MARSHAL ON DECEMBER 21, 2021, SECTION 24.2.8 OF NFPA 101 IS IN THE PROCESS <br />OF BEING MODIFIED TO ELIMINATE THE NEED FOR CERTAIN GRAB BARS. THESE DRAWINGS REFLECT THIS <br />PROPOSED CHANGE. <br />FOR NEW BUILDINGS THREE STORIES OR GREATER IN HEIGHT, THE FOLLOWING QUALITY ASSURANCE PROGRAM <br />FOR FIRE -STOP SYSTEMS, PENETRATIONS AND JOINTS SHALL BE PROVIDED: INSPECTIONS OF INSTALLED <br />FIRE -STOP SYSTEMS SHALL BE PERFORMED BY A THIRD PARTY INSPECTOR IN ACCORDANCE WITH NFPA-1-2012 <br />FIRE CODE SECTION 12.3.2, PER ASTM E 2174 AND E 2393 AS APPLICABLE, IN ACCORDANCE WITH AHJ <br />REQUIREMENTS.. THE THIRD PARTY INSPECTOR WILL BE CONTRACTED BY THE OWNER. REFER ALSO TO <br />SPECIFICATIONS DIVISION 07, PENETRATION FIRESTOPPING <br />MAILBOXES & PARCEL BOXES <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND INSTALLATION OF THE POSTAL <br />BOXES IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, APPLICABLE ACCESSIBILITY <br />REQUIREMENTS, AND THE USPS REQUIREMENTS. <br />2. ALL MAILBOXES AND PARCEL BOXES FOR ALL UNITS COVERED BY THE APPLICABLE ACCESSIBILITY <br />STANDARDS MUST BE INSTALLED WITHIN HEIGHT RANGE INDICATED ON THE DRAWINGS <br />WEATHER/WATER INTRUSION PREVENTION <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER INSTALLATION OF ALL MATERIALS REQUIRED TO <br />PREVENT WATER INTRUSION, INCLUDING BUT NOT LIMITED TO; FLASHINGS, WEATHER/WATER-RESISTIVE <br />BARRIERS (BUILDING WRAP), SELF -ADHERING MEMBRANES, AND SEALANTS AS INDICATED ON THE DRAWINGS <br />OR AS OTHERWISE REQUIRED IF NOT INDICATED. <br />2. ALL PENETRATIONS THROUGH THE EXTERIOR CLADDING SYSTEM SHALL BE PROPERLY SEALED. <br />DECAY & TERMITE PROTECTION <br />1. ALL BUILDINGS SHALL HAVE TERMITE PROTECTION AGAINST SUBTERRANEAN TERMITES, INCLUDING SOIL <br />APPLIED PESTICIDES, BAIT SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF <br />TERMITE PROTECTION LABELED FOR USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION TO COMPLY <br />WITH APPLICABLE BUILDING CODE AND THE AHJ. <br />2. THE CONTRACTOR SHALL PROVIDE TERMITE PROTECTION AS REQUIRED BY ALL APPLICABLE CODES. TERMITE <br />PROTECTION SHALL BE INSTALLED BY A LICENSED PEST CONTROL COMPANY PER THE TERMITICIDE <br />MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH APPLICABLE RULES AND LAWS <br />ESTABLISHED BY THE STATE. <br />3. THE TERMITE PROTECTION SHALL BE PROVIDED BY USING REGISTERED TERMITICIDES, THE TREATMENT <br />SHALL COMPLY WITH APPLICABLE RULES AND LAWS ESTABLISHED BY THE STATE. <br />4. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED AND POSTED AS REQUIRED BY CODE OR BY THE <br />AHJ. IF REQUIRED BY THE AHJ, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE AHJ BY A LICENSED <br />PEST CONTROL COMPANY. <br />5. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST V-0" AWAY FROM BUILDING SIDEWALLS, <br />UNO. <br />6. ALL WOOD FRAMING MEMBER AND FURRING STRIPS IN CONTACT WITH OR ATTACHED DIRECTLY TO MASONRY <br />OR CONCRETE SHALL BE OF APPROVED PRESERVATIVE TREATED (PT) WOOD AND ALL FASTENERS AND <br />ANCHORS TO BE COMPATIBLE. <br />7. PROVIDE CODE REQUIRED CLEARANCE AT EXTERIOR WALL BETWEEN WALL COVERING AND FINAL GRADE FOR <br />TERMITE INSPECTION. <br />BUILDING ADDRESS <br />BUILDING ADDRESS OR NUMBERS, AS APPROVED BY THE AHJ, SHALL BE PROVIDED FOR THE BUILDINGS SO <br />THAT THE ADDRESS OR NUMBER IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY, THE <br />NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. BUILDING ADDRESSES SHALL BE DETERMINED BY <br />THE AHJ AND APPROVED BY THE OWNER. THE CONTRACTOR SHALL VERIFY SIZE AND LOCATION <br />REQUIREMENTS WITH AHJ. <br />FIRE EXTINGUISHERS <br />PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EACH BUILDING AS REQUIRED AND SPECIFIED IN <br />NFPA 10. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN LOCATIONS INDICATED ON THE DRAWINGS <br />OR MINIMUM OF (1) FIRE EXTINGUISHER PER BREEZEWAY, CORRIDOR, GENERAL BUILDING AREA, OR AS <br />OTHERWISE REQUIRED BY THE AHJ. EXTINGUISHERS SHALL BE INSTALLED WITH THE TOP AT 41" MAX FROM <br />THE GROUND. LIGHT HAZARD AREAS: FIRE EXTINGUISHERS SHALL HAVE A MINIMUM RATING OF 2A:10-B:C, <br />UNO. AND BE LOCATED PER FLOOR WITH A MAXIMUM TRAVEL DISTANCE OF 75 FEET TO THE EXTINGUISHER. <br />ORDINARY HAZARD AREAS: FIRE EXTINGUISHERS SHALL HAVE A MINIMUM RATING OF 2A:20-B:C, UNO, AND BE <br />LOCATED PER FLOOR WITH A MAXIMUM TRAVEL DISTANCE OF 50 FEET TO THE EXTINGUISHER. <br />2. WHERE REQUIRED OR AS INDICATED ON THE DRAWINGS, PROVIDE PORTABLE FIRE EXTINGUISHERS IN EACH <br />INDIVIDUAL RESIDENTIAL DWELLING UNIT AS RECOMMENDED BY NFPA 10 AND INSTALLED AS INDICATED ON <br />THE DRAWINGS OR AT A MINIMUM OF (1) FIRE EXTINGUISHER PER FLOOR LEVEL OF A LIVING UNIT WITH A <br />MAXIMUM TRAVEL DISTANCE OF 40 FEET TO THE EXTINGUISHER OR AS REQUIRED BY LOCAL AHJ. EACH <br />EXTINGUISHER SHOULD HAVE A MINIMUM RATING OF 2A:10-B:C, LINO. <br />3. WHERE APPLICABLE, COMMERCIAL KITCHEN AREAS (INCLUDING OUTDOOR KITCHEN AREAS) SHALL BE <br />PROVIDED WITH WET CHEMICAL TYPE, CLASS K FIRE EXTINGUISHERS PER NFPA-10, SIZE AS REQUIRED BY THE <br />AHJ. <br />as <br />3 <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.foru marchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />02/17/2022 <br />Karen V McIntyre <br />AR0017018 <br />SET DISTRIBUTIONS: <br />11/24/21 100% DID Set <br />12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />0 SHEET REVISIONS: <br />PROJECT NO. 4097 <br />Apartments - <br />Generaf Notes <br />Al .03 <br />