Laserfiche WebLink
2 <br />IBM <br />F <br />MECHANICAL NOTES: <br />I. CONTRACTOR TO VERIFY ALL CONDITIONS ON SITE PRIOR TO BIDDING <br />AND BEGINNING WORK AND NOTIFY OF ANY DISCREPANCIES. <br />2. CONTRACTOR SHALL COMPLY WITH 2O04 FLORIDA BUILDING CODE. <br />3. CONTRACTOR TO OBTAIN AND PAY FOR ALL PERMITS, FEES, <br />LICENSES AND INSPECTIONS. <br />4. CONTRACTOR SHALL OBSERVE OSHA SAFETY STANDARDS AND <br />MAINTAIN AREA CLEAN DAILY. <br />S. ALL FINAL CONNECTIONS BY THIS CONTRACTOR TO ALL EQUIPMENT. <br />6. ALL INTERIOR RECTANGULAR DUCTWORK TO BE GALVANIZED <br />SHEET METAL IN ACCORD. WITH SMACNA DUCT CONSTRUCTION <br />STANDARDS, 1/2" W.G.. DISHWASHER EXH. DUCT TO BE ST.STL. <br />7. DUCTWORK SHALL BE FABRICATED AND BRACED IN <br />ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS. <br />8. ALL DUCTWORK SHALL COMPLY WITH NFPA 90A. <br />9. ALL KITCHEN HOOD DUCTWORK SHALL COMPLY WITH NFPA 96, BLACK STEEL. <br />10. FLEXIBLE DUCTWORK SHALL BE INSULATED WITH 1" THICK <br />VAPOR BARRIER, FLEXMASTER TYPE 3 OR EQUAL. NO FLEXIBLE <br />DUCTWORK SHALL BE INSTALLED ABOVE INACCESSIBLE <br />CEILINGS. <br />11. SUPPLY DUCTWORK SHALL BE INSULATED 1" THICK FIBERGLASS <br />WITH VAPOR BARRIER, 25/50 FIRE HAZARD RATING, SEALED SEAMS. <br />12. FURNISH AND INSTALL ALL CONTROL WIRING FOR OPERATION <br />OF EQUIPMENT. <br />13. PROVIDE FOR FLEXIBLE CONNECTIONS AT EQUIPMENT. <br />14. INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE. <br />15. PROVIDE SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW <br />PRIOR TO ORDERING. <br />16. DUCTWORK SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW PRIOR <br />TO FABRICATION, THE CONTRACTOR SHALL PREPARE DETAILED <br />CONSTRUCTION SHOP DRAWINGS OF THE ENTIRE EXTENT OF <br />THE SHEET METAL DUCT INSTALLATION. LOCATIONS OF ALL <br />DUCTS TO BE FIELD VERIFIED TO ELIMINATE INTERFERENCE <br />WITH BUILDING CONSTRUCTION AND WORK OF OTHER TRADES. <br />17. PROPER FIRE PROTECTION MEASURES SHALL BE ENFORCED <br />AT ALL TIMES. <br />18. CONTRACTOR TO COORDINATE DUCTWORK WITH CEILING HEIGHT <br />AND EXISTING STRUCTURAL STEEL. <br />19. ALL WALL AND ROOF PENETRATIONS BY THIS CONTRACTOR. <br />OPENINGS SHALL BE FLASHED, COUNTERFLASHED AND SEALED <br />WEATHERTIGHT AND WATERPROOF. <br />20. CONTRACTOR SHALL PROVIDE, IN WRITING, A ONE (1) YEAR <br />GUARANTEE AND WARRANTY ON ALL MATERIAL, EQUIPMENT <br />AND WORKMANSHIP. ANY DEFECTS WILL BE REPAIRED OR <br />REPLACED AT NO COST TO THE OWNER. <br />21. ALL MECHANICAL EQUIPMENT AND APPLIANCES SHALL BEAR THE <br />LABEL OF AN APPROVED TESTING AGENCY. ALL EQUIPMENT SHALL <br />BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. <br />22. ALL EQUIPMENT SHALL BE IN STRICT ACCORDANCE WITH ASHRAE <br />STANDARD 62.1.2004 AS PER INDOOR AIR QUALITY CONSTRUCTION OF <br />EQUIPMENT STANDARDS. <br />23. ALL LOCAL AND EXHAUST FANS MUST BE A MINIMUM OF 10'-O" AWAY <br />FROM OUT DOOR AIR INTAKES PER FLORIDA 2004 BUILDING CODE. <br />24. EQUIPMENT MANUFACTURES NAMES & MODEL NUMBERS ARE SHOWN <br />FOR BASIS OF DESIGN. <br />25. DUCT MOUNTED SMOKE DETECTORS, PROVIDED BY THE ELECTRICAL <br />CONTRACTOR, SHALL BE MOUNTED BY THIS CONTRACTOR. <br />26. PROVIDE RETURN AIR DUCT WITH 1/2" ACOUSTICAL LINING. <br />27. HOOD EXHAUST DUCTWORK TO HAVE 2 HOUR FIREPROOF INSULATION. <br />28. PROVIDE DUCT SMOKE DETECTORS FOR ALL AC EQUIPMENT <br />2000 CFM OR GREATER. <br />29. PROVIDE FIRE STOPPING AT ALL FIRE WALL PENETRATIONS. <br />SEE ARCHITECTURAL DRAWINGS FOR FIRE WALL LOCATIONS. <br />30. PROVIDE FIRE DAMPERS AT ALL FIRE WALL. SEE ARCHITECTURAL <br />DRAWINGS FOR LOCATIONS. <br />31. CONTRACTOR SHALL BALANCE ALL AIR SYSTEMS PER NEBB. <br />32. ALL DUCTWORK ASSOCIATED WITH POOL AREA TO BE ALUMINUM WITH <br />WATERTIGHT JOINTS AND SEAMS. <br />33. ALL APPURTENANCES REQUIRED FOR A COMPLETE AND OPERATING <br />SYSTEM ARE NOT SHOWN. CONTRACTOR TO PROVIDE ALL APPURTENANCES <br />NECESSARY FOR A COMPLETE OPERATING SYSTEM. CONTRACTOR TO <br />CONTACT ARCHITECT/ENGINEER IN WRITING, PRIOR TO BIDDING FOR <br />CLARIFICATION OF DISCREPANCIES OR OMISSIONS IN DESIGN <br />DOCUMENTS. <br />HVAC ABBREVIATIONS: <br />AFF ABOVE FINISHED FLOOR <br />AHU AIR HANDLING UNIT <br />AP ACCESS PANEL <br />ATC AUTOMATIC TEMPERATURE CONTROL <br />BDD BACKDRAFT DAMPER <br />BHP BRAKE HORSEPOWER <br />BTU BRITISH THERMAL UNIT <br />CD CEILING DIFFUSER <br />CFM CUBIC FEET PER MINUTE <br />DB DRY BULB <br />DEG DEGREES (FAHRENHEIT) <br />DIA/0 DIAMETER <br />DN DOWN <br />DX DIRECT EXPANSION <br />EA EXHAUST AIR <br />EF EXHAUSTFAN <br />EG EXHAUST GRILLE <br />ER EXHAUST REGISTER <br />ESP EXTERNAL STATIC PRESSURE <br />EXH EXHAUST <br />OF DEGREE(S) FAHRENHEIT <br />FD FIRE DAMPER <br />FLA FULL LOAD AMPS <br />HOA HAND-OFF AUTOMATIC SELECTOR SWITCH <br />HP HORSEPOWER <br />HVAC HEATING, VENTILATING, AIR CONDITIONING <br />HAV HEATING & VENTILATING <br />IN/WG INCHES WATER GAUGE <br />KW KILOWATT <br />LAT LEAVING AIR TEMPERATURE <br />LD LINEAR DIFFUSER <br />LVR LOUVER <br />MBH <br />1000 BTU PER HOUR <br />NTS <br />NOT TO SCALE <br />OA <br />OUTSIDE AIR <br />OAD <br />OUTSIDE AIR DAMPER <br />OAI <br />OUTSIDE AIR INTAKE <br />RG <br />RETURN AIR GRILLE <br />RH <br />RELATIVE HUMIDITY <br />RHC <br />REHEAT COIL <br />RPM <br />REVOLUTIONS PER MINUTE <br />RR <br />RETURN AIR REGISTER <br />RS <br />REFRIGERANT SUCTION <br />SEF <br />SMOKE EXHAUST FAN <br />SF <br />SUPPLY AIR FAN <br />SH <br />SENSIBLE HEAT <br />SP <br />STATIC PRESSURE <br />T <br />THERMOSTAT <br />DUCT SYMBOLS: <br />VOLUME <br />DAMPER <br />10" 18" <br />VOLUME <br />DAMPERS <br />VOLUME <br />DAMPER <br />TURNING VANES <br />EXHAUST FAN SCHEDULE <br />STATIC <br />UNIT NO. <br />AREA SERVED <br />DUTY <br />CFM <br />RE <br />PN <br />HP <br />RPM <br />TIP <br />REMARKS* <br />DRIVE <br />BASIS OF DESIGN <br />ELEC. <br />H2� <br />SPEED <br />77 <br />eE <br />LIVING UNITS <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />1 <br />DIRECT <br />CARNES VCDD010C <br />120/1/60 <br />e102 <br />ELEV. RM C125 <br />EXH <br />141 <br />.125" <br />WATTS <br />710 <br />1 <br />DIRECT <br />CARNES VCDD015C <br />120/1/60 <br />eJAN.C12013102 <br />EXH <br />141 <br />.125" <br />WATTS <br />710 <br />1 <br />DIRECT <br />CARNES VCDD015C <br />120/1/60 <br />77 <br />eTOILET <br />C120A <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />1 <br />DIRECT <br />CARNES VCDDOIOC <br />120/1/60 <br />eDISHWASHER300 <br />EXH <br />500 <br />.5" <br />WATTS <br />960 <br />DIRECT <br />CARNES VCDD070C <br />120/1/60 <br />120 <br />GREENHECK <br />e/EF\ <br />ELEC. RM <br />EXH <br />240 <br />.25" <br />WATTS <br />2600 <br />2,5 <br />DIRECT <br />CBF-205-QD <br />120/1/60 <br />300 <br />eBEAUTY <br />C113 <br />EXH <br />534 <br />.75��WATTS <br />980 <br />1 <br />DIRECT <br />CARNES VCDD070C <br />120/1/60 <br />EF <br />131 <br />8 <br />TOILET C106 <br />EXH <br />196 <br />.25" <br />WATTS <br />740 <br />1 <br />DIRECT <br />CARNES VCDD020C <br />120/1/60 <br />77 <br />eTOILET <br />C107 <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />1 <br />DIRECT <br />CARNES VCDD010C <br />120/1/60 <br />EF <br />102 <br />10 <br />ELEV. RM C132 <br />EXH <br />141 <br />.125" <br />WATTS <br />710 <br />1 <br />DIRECT <br />CARNES VCDD015C <br />120/1/60 <br />EF <br />77 <br />11 <br />TOILET C135A <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />1 <br />DIRECT <br />CARNES VCDD010C <br />120/1/60 <br />EF <br />77 <br />12 <br />TOILET C204 <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />1 <br />DIRECT <br />CARNES VCDD010C <br />120/1/60 <br />EF <br />77 <br />13 <br />TOILET C304 <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />1 <br />DIRECT <br />CARNES VCDD010C <br />120/1/60 <br />EF <br />77 <br />14 <br />JANITOR C133 <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />1 <br />DIRECT <br />CARNES VCDD010C <br />120/1/60 <br />EF <br />77 <br />15 <br />JANITOR C233 <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />i <br />DIRECT <br />CARNES VCDD010C <br />120/1/60 <br />EF <br />77 <br />16 <br />JANITOR C333 <br />EXH <br />93 <br />.25" <br />WATTS <br />640 <br />1 <br />DIRECT <br />CARNES VCDD010C <br />120/1/60 <br />EF <br />RESIDENTIAL <br />DRYER <br />EXH <br />120 <br />2.00" <br />83 <br />WATTS <br />800 <br />7,8 <br />DIRECT <br />FANTECH DBF4XLT <br />120/1/60 <br />17 <br />BOOSTER <br />REMARKS: <br />1. RADIATION DAMPER 3. SHUTTER DAMPER 5. FAN THERMOSTAT 7. FURNISH WITH PRESSURE SWITCH <br />2. WALL SLEEVE 4. MOTOR GUARD 6. EQUAL PRODUCTS BY GREENHECK ARE APPROVED 8. FURNISH WITH DBLT4 LINT TRAP <br />TURNING VANES <br />RETURN OR <br />EXHAUST <br />SUPPLY <br />TURNING <br />VANES <br />45° EL. <br />90° EL:'-W <br />WIDTH "W" = INS. RADIUS <br />TURNING <br />VANES <br />�x <br />RETURN OR <br />EXHAUST <br />kLNJ I;i <br />SUPPLY <br />TURNING <br />VANES <br />AIR DISTRIBUTION, GENERAL SYMBOLS & <br />NOMENCLATURE: <br />NOTE: <br />VOLUME DAMPER 1. FOR EQUIPMENT SCHEDULES FOR CONDENSING UNITS (CU), <br />UNIT AIR HANDLING UNITS (FSO) AND CEILING CASSETTE <br />UNITS (FXF), SEE MECHANICAL SPECIFICATIONS. <br />DAMPER <br />(type as indicated; BBD, <br />�- MOD, FD, SD/FD, VD, etc.) <br />- DAMPER <br />ODUCT MOUNTED SMOKE DETECTOR <br />D <br />c FLEXIBLE CONNECTION <br />FLEXIBLE DUCTWORK <br />FLEXIBLE DUCTWORK <br />TO THERMOSTAT <br />TURNING VANES <br />��- FULLY LOUVERED DOOR (LIVING UNITS) <br />DIFFUSER, REGISTER & GRILLE SCHEDULE <br />DUTY <br />SYMBOL <br />AREA SERVED <br />MODEL <br />FINISH <br />REMARKS <br />BAKED WHITE <br />SUPPLY <br />CD <br />AS NOTED <br />CARNES SETS <br />ENAMEL <br />W/ OPPOSED BLADE DAMPER <br />BAKED WHITE <br />SUPPLY <br />SR <br />AS NOTED <br />CARNES RTDB <br />ENAMEL <br />W/ OPPOSED BLADE DAMPER <br />BAKED WHITE <br />RETURN <br />RR <br />AS NOTED <br />CARNES RSAB <br />ENAMEL <br />BAKED WHITE <br />EXHAUST <br />ER <br />AS NOTED <br />CARNES RSAB <br />ENAMEL <br />BAKED WHITE <br />TRANSFER <br />GR <br />AS NOTED <br />CARNES RSAB <br />ENAMEL <br />WITH FIRE DAMPER <br />BAKED WHITE <br />SUPPLY <br />SG <br />AS NOTED <br />CARNES RSAB <br />ENAMEL <br />BAKED WHITE <br />SUPPLY <br />FRD <br />AS NOTED <br />TITUS TMSA-FR <br />ENAMEL <br />BAKED WHITE <br />RETURN <br />FRG <br />AS NOTED <br />TITUS PAS-FR <br />ENAMEL <br />FAN SCHEDULE <br />STATIC <br />UNIT NO. <br />AREA SERVED <br />CFM <br />PRESSURE <br />HP <br />RPM <br />TIP <br />REMARKS* <br />DRIVE <br />BASIS OF DESIGN <br />ELEC <br />IN. H2O <br />SPEED <br />eATRIUM <br />1 <br />14,000 <br />0.5" <br />5 <br />884 <br />5,909 <br />1, 2, 3, 4, 5 <br />BELT <br />COOK 330CPS <br />208/3/60 <br />eAE <br />ATRIUM <br />14,000 <br />0.5" <br />5 <br />884 <br />5,909 <br />1,2,3,4,5 <br />BELT <br />COOK 330CPS <br />208/3/60 <br />REMARKS: <br />1. EXPDXY COATING 4. BIRSCREEN <br />2. WEATHER OVER 5. UL LISTED FOR SMOKE CONTROL <br />3. RAIN HOOD <br />KITCHEN MAKE-UP / EXHAUST UNIT <br />UNIT No. <br />CFM <br />SUPPLY <br />CFM <br />EXHAUST <br />SUPPLY <br />ESP <br />SUPPLY <br />HP <br />EXHAUST <br />ESP <br />SUPPLY <br />HP <br />MBH HEATING <br />MOH <br />GAS <br />CF/H <br />ELECTRIC <br />FUSING <br />REMARKS <br />BASIS OF DESIGN <br />MUA <br />1,958 <br />3,375 <br />1" <br />1.1/2 <br />2" <br />3 <br />NONE <br />NONE <br />208/3/60 <br />30 HACR <br />12" HIGH GALV. PREFAB ROOF CURB, <br />SUPPLY EXTENSION <br />GREENHECK KSF <br />1 <br />VENT SCHEDULE <br />UNIT NO. <br />CFM <br />SQ. FT. <br />REMARKS <br />BASIS OF DESIGN <br />RV <br />1 <br />534 <br />.96 <br />PREFAB CURB, BIRDSCREEN <br />CARNES GSAA12 <br />LOUVER SCHEDULE <br />UNIT NO. WIDTH HEIGHT FREE AREA (SQFT) BASIS OF DESIGN REMARKS <br />FURNISH WITH ES-30 (45x8) BACKDRAFT DAMPER <br />L 45 IN. 8 IN. 0.55 GREENHECK EHH-501X FURNISH WITH TITUS 23RL RETURN GRILLE (45x8 FACE W/ WHITE BORDER) <br />1 FURNISH LOUVER WIT BAKED ENAMEL FINISH. COLOR TO BE CHOSEN BY OWNER. <br />ROOFTOP AIR CONDITIONING UNIT SCHEDULE <br />UNIT <br />NO. <br />SUPPLY <br />AIR <br />CFM <br />OUTSIDE <br />AIR <br />CFM <br />COOLING <br />ELECTRIC HEATING <br />RE -HEAT <br />ELECTRICAL <br />REMARKS <br />BASIS OF DESIGN <br />EXT <br />S.P. <br />EAT <br />SENS <br />BTU/HR <br />TOTAL <br />BTU/HR <br />COIL LAT <br />BTU/HR <br />OUTPUT <br />BTU/HR <br />INPUT <br />ELECTRIC <br />FLA <br />EAT <br />LAT <br />BTU/HR <br />OUTPUT <br />LAT <br />LAT <br />VOLTAGE <br />MCA <br />MOCP <br />SA FAN <br />HP <br />CU FAN <br />HP <br />DB <br />WB <br />DB <br />WB <br />OAU <br />4550 <br />4550 <br />2" <br />94 <br />79 <br />188,500 <br />377,510 <br />56 <br />55 <br />205,100 <br />4x15KW <br />166.8 <br />37 <br />79 <br />104,000 <br />75 i 61.7 <br />75161.7 <br />230/3/60 <br />188 <br />225 <br />5.0 <br />0.75 <br />1 2 3 4 5 6 7 8 9 <br />AAON RM-025.8-0-BB02.344 <br />Nam <br />be advised thisA <br />of . <br />hractor in � . <br />review is not intemw <br />bmitted n1ans it it. - <br />40ta <br />to be 2 <br />u* safety codes. <br />� val of the <br />REMARKS: <br />1. 2" PLEATED FILTER <br />2. THROUGH BASE ELECTRICAL & GAS <br />3. UNIT MOUNTED DISCONNECT <br />4. POWERED CONVENIENCE OUTLET <br />S. SMOKE DETECTOR <br />6. PROVIDE WITH 12" TALL GALVANIZED ROOF CURB <br />7. PROVIDE WITH 2-POSITION MOTORIZED OUTSIDE AIR DAMPER <br />8. FACTORY HINGED PANELS <br />9. DUAL SETPOINT AUTOCHANGEOVER SENSOR WITHOUT STATUS INDICATOR LIGHTS <br />DAIKEN SYSTEM COORDINATION <br />GENERAL CONTRACTOR SHALL REFER TO MECHANICAL <br />SPECIFICATIONS FOR DAIKEN SYSTEM AIR HANDLING <br />UNIT CAPACITIES, CONDENSING UNIT CAPACITIES, <br />REFRIGERANT PIPE SIZES, AND ASSOCIATED <br />ACCESORIES. CONTACT ROB TEETSEL AT PRO -TECH AIR <br />CONDITIONING AND HEATING, INC. 407.291.1642 <br />ALL FORK SHALL COMPLY WITHALL <br />PREVAILING CODES, <br />CITY FLORIDABUILDRIG <br />CODE, NATIONAL ELECTRIC CODE ANIi <br />OF ZEPHYRHILLS ORDINANCES <br />llWDA-r <br />PLANS EXANNER <br />,"u"lry to ensure that the plans are . <br />+ance *rich all applicable NFPA codes ano <br />e In a event that further examination or <br />h ®n reveals areas of no' <br />�e ttr 's n-c°mP►iar,Ce, it shall be <br />bft responsibility, at their sere expense to <br />those areas in compliance. The City assumes no <br />bitity for the contractors failure to be in compli <br />anM <br />"ka* NFPA Codes and local ordin <br />. <br />FREDERICK MUSCATELLO, PE <br />FL. PE # 62451 <br />PO Box 941168 <br />MAITLAND, FL 32794-1168 <br />EMAIL: fredOfcmengineering.com <br />v <br />t <br />U <br />z <br />O <br />U <br />� <br />O <br />w <br />p� <br />U <br />0 <br />o <br />O <br />O <br />w <br />600 <br />aD <br />_0 <br />N <br />r <br />0 <br />0 <br />w <br />U <br />.. N <br />M <br />m <br />]C <br />W <br />o <br />UJ <br />(n <br />project no. <br />drawn by: <br />2006-068.00 <br />date: <br />checked by: <br />NOV , 2006 <br />scale: <br />approved by: <br />sheet no. <br />ml A 00 <br />a <br />L <br />c <br />ca @ <br />0L <br />C N <br />0)_C <br />N <br />m o <br />N 3 <br />0 0r <br />>'N <br />t c <br />+1 0 <br />� C <br />0 0 <br />C <br />�+ C <br />0 N <br />30 <br />