My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38130 Pretty Pond Rd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38130 Pretty Pond Rd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:53:26 AM
Creation date
2/18/2025 3:15:16 PM
Metadata
Fields
Template:
Building Plans
Street #
38130
Location
Pretty Pond Rd
Contractor
A1A Electrical Services
Building Plans - Permit #
20976
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
av <br />�i <br />Z Lca u <br />]C <br />u <br />w_Z <br />cc <br />0 u d <br />SCOPE OF WORK <br />TO PROVIDE COMPLIANCE WITH THE FLORIDA PROPOSED RULE 58A-5.036 EMERGENCY <br />ENVIRONMENTAL CONTROL FOR ASSISTED LIVING FACILITY. <br />PROJECT SITE INFORMATION <br />LOCATION: AMERICAN HOUSE ZEPHYRHILLS <br />38130 PRETTY POND ROAD. <br />ZEPHYRHILLS, FLORIDA 33540 <br />PASCO COUNTY <br />FACILITY TYPE: ASSISTED LIVING <br />144 BEDS <br />THREE STORY BUILDING <br />EVACUATION ZONE: ZONE NON EVAC <br />FLOOD ZONE: ZONE X <br />SINGLE CAMPUS: APPLICABLE <br />MINIMUM COOLING ZONE REFUGE AREA = 144 BEDS X 20 SQ.FT. XO.80 = 2,304 SQ.FT. <br />DESIGN CRITERIA IS TO REPLACE THE EXISTING 125 kW 208/120 V LEVEL 1 EMERGENCY <br />GENERATOR, WITH A NEW 400 kW 208/120 V LEVEL 1 NATURAL GAS SOUND ATTENUATED <br />EMERGENCY GENERATOR TO PROVIDE POWER TO A NEW 1600 A, NEMA 3R, SERVICE RATED <br />AUTOMATIC TRANSFER SWITCH (ATS). THE NEW LEVEL 1 EMERGENCY GENERATOR WILL <br />PROVIDE POWER THROUGH THE EXISTING ATS TO THE CRITICAL, LIFE SAFETY, AND EQUIPMENT <br />BRANCH CIRCUITS, AND PROVIDE STANDBY POWER UTILIZING THE SERVICE RATED ATS <br />BETWEEN NORMAL POWER AND THE GENERATOR POWER. THIS WILL SUPPLY POWER TO THE <br />ENTIRE BUILDING BASED UPON THE UTILITY BILLS OVER THE LAST YEAR. THE FACILITY <br />MAXIMUM DEMAND WAS 221 kW. THE NEW GENERATOR WILL UTILIZE NATURAL GAS AS THE <br />FUEL SOURCE IN ACCORDANCE WITH FLORIDA RULE 58A-5.036 (1)(b)3. CO/SMOKE DETECTORS <br />WILL REPLACE THE EXISTING SMOKE DETECTORS CONNECTED TO THE FIRE ALARM SYSTEM IN <br />THE RESIDENCE ROOM LOCATED ON THE DISCHARGE SIDE OF THE NEW GENERATOR. <br />ELECTRICAL LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />20 AMP ISOLATED GROUND DUPLEX <br />IG� <br />RECEPTACLE (ORANGE DEVICE) <br />18" AFF TO C/L <br />20 AMP ISOLATED GROUND DUPLEX <br />IGW- <br />RECEPTACLE (ORANGE DEVICE) <br />44" AFF TO C/L, OR AS NOTED <br />IG <br />20 AMP ISOLATED GROUND DUPLEX RECEPTACLE <br />18" AFF TO C/L <br />(ORANGE DEVICE) AND 20 A DUPLEX RECEPTACLE <br />20 AMP SINGLE RECEPTACLE <br />18" AFF TO C/L <br />EWC0- <br />20 AMP SINGLE RECEPTACLE FOR <br />COORDINATE WITH <br />ELECTRIC WATER COOLER <br />GENERAL CONTRACTOR <br />20 AMP QUADPLEX RECEPTACLE <br />18" AFF TO C/L <br />20 AMP GFCI DUPLEX RECEPTACLE <br />18" AFF TO C/L <br />WP($I`__ <br />20 AMP GFCI DUPLEX RECEPTACLE WITH <br />18" AFF TO C/L <br />WEATHERPROOF COVER <br />(D-- <br />20 AMP DUPLEX RECEPTACLE <br />18" AFF TO C/L <br />20 AMP DUPLEX RECEPTACLE ON <br />18" AFF TO C/L <br />EMERGENCY SYSTEM <br />MS <br />SWITCH, MOTOR RATED <br />46" AFF TO C/L <br />S <br />SWITCH, SINGLE POLE <br />46" AFF TO C/L <br />® ® <br />EXHAUST FAN <br />REFER TO MECHANICAL <br />DRAWINGS <br />EMERGENCY POWER OFF BUTTON WITH <br />46" AFF TO C/L <br />MANUAL RESET. RED COLOR. <br />Q <br />OUTLET, JUNCTION, OR PULL BOX <br />AS NOTED <br />0 ® <br />KEYNOTES / SCHEDULED NOTES <br />BRANCH CIRCUIT CONCEALED ABOVE CEILING OR <br />IN WALL. TWO CONDUCTORS PLUS GROUND <br />REQUIRED UNLESS OTHERWISE NOTED. <br />—}�— <br />BRANCH CIRCUIT WITH ISOLATED GROUND <br />HOME RUN TO PANELBOARD <br />BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB <br />— _ — <br />OR UNDERGROUND <br />— — — — <br />BRANCH CIRCUIT CONDUIT EXPOSED <br />—W— <br />SURFACE MOUNTED DECORATIVE <br />RACEWAY (E.G. WIREMOLD) <br />—LV— <br />LOW VOLTAGE WIRING INSTALLED IN CONDUIT <br />—LS— <br />LIFE SAFETY BRANCH CIRCUIT <br />—C— <br />CRITICAL BRANCH CIRCUIT <br />—EQ— <br />EQUIPMENT BRANCH CIRCUIT <br />—o <br />CONDUIT RUN UP <br />—� <br />CONDUIT RUN DOWN <br />EQUIPMENT CONNECTION <br />USING FLEXIBLE CONDUIT <br />PANELBOARD UNDER 250 VOLTS <br />72" AFF TO TOP <br />® <br />PANELBOARD OVER 250 VOLTS <br />72" AFF TO TOP <br />© <br />DRY TYPE TRANSFORMER <br />REFER TO TRANSFORMER <br />SCHEDULE <br />B <br />AUTOMATIC TRANSFER SWITCH <br />72" AFF TO TOP <br />GENERATOR REMOTE ANNUNCIATOR PANEL <br />60" AFF TO TOP <br />GRAP <br />GENERATOR <br />SECURE TO CONCRETE SLAB WITH <br />SPRING VIBRATION ISOLATORS <br />E;�3 <br />TIME SWITCH <br />WALL MOUNTED <br />® <br />CONTACTOR <br />WALL MOUNTED <br />FRAME SIZE <br />❑p 3 3 <br />DISCONNECT SWITCH <br />60" AFF TO TOP <br />FUSE SIZE <br />0 <br />MAGNETIC MOTOR STARTER <br />60" AFF TO TOP <br />STARTER SIZE <br />COMBINATION MAGNETIC MOTOR STARTER <br />60" AFF TO TOP <br />STARTER SIZE <br />Ep <br />MANUAL MOTOR STARTER <br />60" AFF TO TOP <br />STARTER SIZE <br />MOTOR CONNECTION <br />AS NOTED <br />® <br />ELECTRIC DUCT HEATER <br />REFER TO MECHANICAL <br />DRAWINGS <br />THERMOSTAT <br />REFER TO MECHANICAL <br />DRAWINGS <br />® <br />MOTORIZED DAMPER <br />REFER TO MECHANICAL <br />DRAWINGS <br />GENERAL ELECTRICAL CONSTRUCTION NOTES <br />1. PROVIDE PLASTIC COVERED TYPED DIRECTORY CARDS BEHIND DOORS OF NEW AND EXISTING <br />BRANCH CIRCUIT PANELBOARDS AFFECTED UNDER THE SCOPE OF THIS PROJECT. <br />DIRECTORIES SHALL INDICATE DEVICES BEING SERVED INCLUDING SPACE NUMBERS IN <br />WHICH DEVICES OR FIXTURES ARE LOCATED. SPACE NAMES AND NUMBERS SHALL MATCH <br />INSTALLED GRAPHICS IF DIFFERENT FROM THE SPACE NAMES AND NUMBERS ON DRAWINGS. <br />2. ELECTRICAL CONTRACTOR (E.C.) SHALL REFER TO THE ELECTRICAL SPECIFICATIONS FOR <br />ADDITIONAL DESIGN STANDARDS. THE ELECTRICAL SPECIFICATIONS ARE A BINDING PART OF <br />THE CONSTRUCTION DOCUMENTS. WHENEVER A CONFLICT OCCURS BETWEEN THE <br />CONTRACT DOCUMENTS AND THE SPECIFICATIONS, THE E.C. SHALL CONTACT APG <br />ENGINEERING FOR CLARIFICATION. <br />3. THE E.C. SHALL PROVIDE CODE COMPLIANT PENETRATIONS FOR ALL NEW CONDUITS <br />ENTERING/EXITING FIRE RATED WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR <br />LOCATIONS OF ALL FIRE RATED WALLS. E.C. SHALL NOTIFY THE OWNER OF ALL EXISTING <br />NON -CODE COMPLIANT ELECTRICAL PENETRATIONS WITHIN THE PROJECT SCOPE <br />(INCLUDING BUT NOT LIMITED TO EXISTING ELECTRICAL ROOMS AND CORRIDORS) AND IT <br />SHALL BE THE RESPONSIBILITY OF THE OWNER TO CORRECT. <br />4. IT IS THE RESPONSIBILITY OF THE E.C. TO REMOVE AND RE -INSTALL ANY LUMINAIRES OR <br />CEILING MOUNTED DEVICES NEEDING TO BE TEMPORARILY REMOVED DUE TO THE <br />RENOVATION OF ANY MECHANICAL OR ELECTRICAL SYSTEMS. THE E.C. SHALL VERIFY ALL <br />AREAS OF POTENTIAL CEILING RE -WORK PRIOR TO BID. <br />5. THE E.C. SHALL VISIT THE SITE PRIOR TO BID AND ALLOW FOR EXISTING CONDITIONS IN BID. <br />THE E.C. SHALL CONFIRM WITH OWNER TO MATCH THE ESTABLISHED COLOR SCHEME OF <br />EXISTING ELECTRICAL DEVICES ON SITE. <br />6. THE E.C. SHALL INCLUDE A GREEN INSULATED GROUNDING CONDUCTOR WITHIN ALL <br />BRANCH CIRCUITS. SIZE GROUNDING CONDUCTOR PER N.E.C. TABLE 250.122. <br />DESIGN GENERAL NOTES <br />1. VOLTAGE DROP CALCULATIONS HAVE BEEN PERFORMED AND COMPLY WITH FLORIDA <br />BUILDING CODE 2017 ENERGY CONSERVATION, CHAPTER 4, SECTION C405.6.3. FEEDER <br />AND BRANCH CIRCUITS COMBINED HAVE BEEN SIZED FOR A MAXIMUM VOLTAGE DROP OF <br />FIVE PERCENT (5%) AT DESIGN LOAD. DURING CONSTRUCTION ALL 208/120 VOLT BRANCH <br />CIRCUITS THAT EXCEED 120 FEET IN LENGTH FROM THE ELECTRIC PANEL TO THE DEVICE <br />SHALL REQUIRE THE CONDUCTORS TO BE UPSIZED TO THE NEXT NOMINAL SIZE SO AS NOT <br />TO EXCEED THE MAXIMUM VOLTAGE DROP. <br />2. THE INSTALLATION SHALL COMPLY WITH ALL LAWS IN EFFECT APPLYING TO ELECTRICAL <br />INSTALLATIONS. THE FOLLOWING CODES ARE APPLICABLE: <br />2.1. FLORIDA PROPOSED RULE 58A-5.036 (3/26/18) <br />2.2. NFPA 70: NATIONAL ELECTRICAL CODE (2014) <br />2.3. NFPA 99: STANDARD FOR HEALTH CARE FACILITIES (2015) <br />2.4. NFPA 101: LIFE SAFETY CODE (2015) <br />2.5. NFPA 110: STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS (2013) <br />2.6. NFPA 241: STANDARD FOR SAFEGUARDING CONSTRUCTION ALTERATION AND <br />DEMOLITION OPERATIONS (2013) <br />2.7. NFPA 780 : STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION SYSTEM <br />(2013) <br />2.8. FLORIDA BUILDING CODE (2017) <br />2.9. FLORIDA FIRE PREVENTION CODE (6TH EDITION) (2017) <br />2.10. FACILITY GUIDELINE INSTITUTE FOR DESIGN AND CONSTRUCTION OF HEALTHCARE <br />FACILITIES (2014) <br />GENERAL NOTES <br />1. AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL ELECTRICAL <br />RACEWAYS AND SHALL BE SIZED IN ACCORDANCE WITH N.E.C. ARTICLE 250-122. <br />2. DISREGARD SYMBOLS AND ABBREVIATIONS NOT USED ON CONTRACT DOCUMENTS. <br />ELECTRICAL <br />ABBREVIATIONS <br />AFF - ABOVE FINISHED FLOOR <br />LW - LOW WHITE <br />AHU -AIR HANDLING UNIT <br />HP - HORSEPOWER, HEAT PUMP <br />BFG -BELOW FINISHED GRADE <br />HVAC - HEATING, VENTING AIR CONDITIONING <br />C -CONDUIT <br />JB -JUNCTION BOX <br />CLG -CEILING MOUNTED <br />LRA - LOCKED ROTOR AMPERES <br />C/L - CENTERLINE <br />MCB - MAIN CIRCUIT BREAKER <br />CU - CONDENSING UNIT <br />MLO - MAIN LUGS ONLY <br />CW -COOL WHITE <br />N- NEUTRAL <br />DN - DOWN <br />NL - NIGHT LIGHT <br />EDH - ELECTRIC DUCT HEATER <br />OB - OUTLET BOX <br />EF - EXHAUST FAN <br />PB - PULL BOX, PUSHBUTTON <br />ENCL - ENCLOSURE <br />PS - PAY STATION <br />EWC - ELECTRIC WATER COOLER <br />RECEPT - RECEPTACLE <br />EWH - ELECTRIC WATER HEATER <br />SC -SMOKE COMPARTMENT <br />EX - EXPLOSION PROOF <br />SF -SUPPLY FAN <br />FCU - FAN COIL UNIT <br />SPEC -SPECIFICATIONS <br />FHP - FRACTIONAL HORSEPOWER <br />TL - TWISTLOCK <br />FLA -FULL LOAD AMPERES <br />TP -TAMPER PROOF <br />GND -GROUND <br />TTB -TELEPHONE TERMINAL BOARD <br />GFI - GROUND FAULT INTERRUPTER <br />WP - WEATHER PROOF <br />GWH -GAS WATER HEATER <br />WR - WEATHER RESISTANT <br />HID - HIGH INTENSITY DISCHARGE <br />WW - WARM WHITE <br />HOA - HANDS OFF AUTOMATIC <br />XFMR -TRANSFORMER <br />HORIZ - HORIZONTAL <br />CU -COPPER <br />AL -ALUMINUM <br />ELECTRICAL SHEET INDEX <br />NUMBER <br />DESCRIPTION <br />E0.1 <br />ELECTRICAL NOTES, LEGENDS, AND SHEET INDEX <br />E1.1 <br />ELECTRICAL PARTIAL SITE PLAN <br />E2.1 <br />ELECTRICAL FLOOR PLAN <br />E2.2 <br />ENLARGED ELECTRICAL ROOM AND GENERATOR LOCATION <br />E3.1 <br />ELECTRICAL DETAILS <br />E3.2 <br />ELECTRICAL DETAILS <br />E4.1 <br />ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULES <br />E5.1 <br />ELECTRICAL SPECIFICATIONS <br />E5.2 <br />ELECTRICAL SPECIFICATIONS <br />E5.3 <br />ELECTRICAL SPECIFICATIONS <br />E5.4 <br />ELECTRICAL SPECIFICATIONS <br />E5.5 <br />ELECTRICAL SPECIFICATIONS <br />E5.6 <br />ELECTRICAL SPECIFICATIONS <br />E6.1 <br />ELECTRICAL COORDINATION STUDY AND FAULT CURRENT STUDY <br />TO THE BEST OF THE ENGINEERS KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER 553.79 AND CHAPTER 633, FLORIDA STATUTES. <br />Q <br />'% <br />O <br />O <br />Ql <br />��,OO <br />Ln <br />a <br />z <br />u <br />tm <br />m <br />m <br />W <br />N <br />N <br />tj <br />u0 <br />x <br />LLIJ <br />3 <br />sC <br />LL <br />� <br />3 <br />� <br />z <br />z <br />FO <br />W <br />z0 <br />CL <br />a <br />Wuj <br />w <br />LL <br />l7 <br />Z <br />m <br />J <br />N <br />a <br />N <br />00 <br />— <br />M <br />t <br />N <br />uO <br />Z <br />rn <br />m <br />v <br />� <br />W <br />b <br />O <br />— <br />Q, <br />> <br />a <br />LL <br />U <br />4A <br />qt <br />M <br />= <br />LU <br />u <br />Linca <br />N <br />CW <br />a) <br />G <br />Q <br />q-4- <br />U <br />J <br />crm <br />a <br />W <br />fV <br />W <br />{..f` <br />D <br />O <br />O <br />Q <br />ZO <br />W <br />�M <br />CCZ <br />d' <br />Ln <br />M <br />Lu <br />V <br />= <br />C <br />a <br />"a <br />L. <br />L. <br />W <br />W <br />Sa <br />G <br />Mt <br />z <br />M <br />N <br />V, LEWIS ✓p�� <br />'No 38680 * = <br />tea <br />Qom•; STATE OF <br />�S'•.'LORIOP.•' <br />'IIII11110%\0 <br />George Johnson, P.E. <br />PE 38680 <br />ISSUE DATE: 10/19/2018 <br />PROJECT NUMBER: 2847 <br />REVISIONS: <br />NO. DATE I DESCRIPTION <br />ELECTRICAL NOTES, <br />LEGENDS, AND SHEET INDEX <br />EOm <br />© 2018 APG ENGINEERING <br />
The URL can be used to link to this page
Your browser does not support the video tag.