My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38130 Pretty Pond Rd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38130 Pretty Pond Rd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:53:26 AM
Creation date
2/18/2025 3:15:16 PM
Metadata
Fields
Template:
Building Plans
Street #
38130
Location
Pretty Pond Rd
Contractor
A1A Electrical Services
Building Plans - Permit #
20976
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t Y <br />Q's <br />U <br />11" <br />GENERATOR IS A SEPARATELY <br />DERIVED SYSTEM DO NOT <br />REMOVE N-G BOND AT <br />GENERATOR ::L <br />TYPICAL FOR EACH <br />91. <br />SERVICE DISCONNECTS N <br />TYPICAL FOR EACH <br />1 NAMEPLATE DETAIL <br />NOT TO SCALE <br />OVER <br />LOW <br />HIGH ENGINE <br />HIGH ENGINE <br />CRANK <br />WATER <br />TEMP. <br />TEMP. <br />SHUTDOWN <br />TEMP. <br />PRE -ALARM <br />SHUTDOWN <br />LOW OIL <br />LOW OIL <br />OVER <br />LOW <br />PRESSURE <br />PRESSURE <br />SPEED <br />FUEL <br />PRE -ALARM <br />SHUTDOWN <br />SHUTDOWN <br />PRESSURE <br />LOW <br />CONTROLS <br />LOW <br />BATTERY <br />COOLANT <br />NOT IN <br />CRANKING <br />CHARGER <br />LEVEL <br />AUTO <br />VOLTAGE <br />FAILURE <br />LOW <br />0 <br />0 <br />BATTERY <br />COMMON <br />SILENCE <br />LAMP <br />VOLTAGE <br />ALARM <br />ALARM <br />TEST <br />v <br />GENERATOR REMOTE ANNUNCIATOR PANEL (GRAP) DETAIL <br />NOT TO SCALE <br />NEW NATURAL GAS GENERATOR 350 kW/ 438 kVA <br />OUTDOOR <br />TIER 3 <br />LEVEL 2 <br />TYPE 60 <br />GENERATOR PERFORMANCE NOTES <br />1. A MANUFACTURER'S REPRESENTATIVE SHALL BE PRESENT AT THE <br />PRE- AHCA AND FINAL AHCA SURVEYS TO SIMULATE ALARMS <br />AND SHUTDOWN TESTS PER NFPA 110 REQUIREMENTS. <br />GENERATOR ALARM DETAIL <br />NOT TO SCALE <br />BRANCH CIRCUIT FOR POWER RECEPTACLE. <br />cn <br />EQUIPMENT <br />NAME <br />� 11 � � � � � 11 3/8" LETTERS <br />EQUIPMENT <br />VOLTAGE <br />1600 A, 208 V, 3 P, 4W /1/4" LETTERS <br />PANELBOARD O <br />SERVICE RATED SOURCE <br />/4" <br />1/4"LETTERS <br />G EN I STAND-BY SYSTEM <br />LETTERS <br />NOTES: <br />1. NAMEPLATE SHALL BE 1/16" PHENOLIC PLASTIC LAMINATE WITH COLORS <br />AS FOLLOWS: <br />POWER SYSTEM <br />NAMEPLATE <br />LETTERING <br />NORMAL <br />BLACK PLATE <br />WHITE TEXT <br />CRITICAL BRANCH <br />ORANGE PLATE <br />BLACK TEXT <br />LIFE SAFETY BRANCH <br />YELLOW PLATE <br />BLACK TEXT <br />EQUIPMENT SYSTEM <br />GREEN PLATE <br />WHITE TEXT <br />GENERATOR DISTRIBUTION <br />PURPLE PLATE <br />WHITE TEXT <br />2. SECURE NAMEPLATE TO SURFACES WITH (2) 5/32" FLATHEAD BRASS <br />SCREWS. <br />AUTOMATIC TRANSFER SWITCH <br />NAMEPLATE IDENTIFICATION <br />NOT TO SCALE <br />WATER JACKET <br />HEATER <br />, GENERATOR <br />PNL LSMP - 9 W AT ERHOUSING <br />I (SEE SPECIFICATIONS) <br />i ANNUNCIATOR <br />PANEL <br />CONTROL <br />i WIRING AS <br />REQUIRED <br />i GENERATOR <br />WATER JACKET HEATER, <br />3 #10 AWG, 1 #10 AWG <br />G N D 3/4" CONDUIT TO <br />i PNL LSMP-7 <br />0 <br />0 <br />I <br />i 1 <br />i 0 <br />BATTERY CHARGER, 2 <br />i #10 AWG, 1 #10 AWG <br />GENERATOR i GND 3/4" CONDUIT TO <br />CONTROL PANEL i PNL LSMP - 6 <br />BATTERY CHARGER EPO <br />CONTROL WIRING AS <br />REQUIRED TO <br />TRANSFER SWITCHES <br />EMERGENCY GENERATOR SYSTEM - <br />INTERLOCKING DIAGRAM <br />NOT TO SCALE <br />NTROL WIRING TO AUTOMATIC TRANSFER SWITCH <br />a - <br />° d <br />LV CABLING ( PER GENERATOR <br />MANUFACTURER) IN A 1" CONDUIT TO THE <br />e GENERATOR REMOTE ANNUNCIATOR PANEL. <br />41 <br />as <br />OPTIONAL STAND-BY GENERATOR. <br />ELECTRICAL STUB -UP AREAS <br />-d'° <br />L n dd- <br />EMERGENCY GENERATOR DETAIL <br />—SEE STRUCTURAL DETAIL DRAWINGS S1.0 <br />FOR ADDITIONAL INFORMATION <br />GROUND OBSERVATION BOX <br />GROUNDING <br />ELECTRODE SYSTEM <br />5/8" x 10'-0" CU. <br />GROUND ROD. <br />GROUNDING <br />ELECTRODE <br />CONDUCTOR o <br />BOLLARDS <br />REFER TO STRUCTURAL <br />ENGINEERING DRAWINGS FOR <br />ADDITIONAL INFORMATION <br />CONCRETE SLAB <br />14 <br />d° a GRADE <br />° SIDE VIEW <br />1/16" THICK WHITE PLASTIC WITH <br />FACE COLORED PER SPECIFICATIONS <br />1/2" HIGH LETTERING <br />i <br />FOR PANELBOARD NAME <br />�( �( <br />PANEL "XXXX" <br />1/4" HIGH LETTERING <br />I20/208V, 30, 4W <br />FOR REMAINING TEXT <br />FED FROM PANEL "XXXX" <br />VIA T-XXX <br />TYPICAL 120/2080V PANELBOARD <br />PANELBOARD NAME PANEL "XXXX" <br />PANELBOARD VOLTAGE 277/48OV, 30, 4W <br />PANELBOARD SOURCE FED FROM PANEL "XXXX" <br />TYPICAL 277/480V PANELBOARD <br />NOTES: <br />1. NAMEPLATE SHALL BE 1/16" PHENOLIC PLASTIC LAMINATE WITH COLORS AS FOLLOWS: <br />POWER SYSTEM <br />NAMEPLATE <br />LETTERING <br />NORMAL <br />BLACK PLATE <br />WHITE TEXT <br />CRITICAL BRANCH <br />ORANGE PLATE <br />BLACK TEXT <br />LIFE SAFETY BRANCH <br />YELLOW PLATE <br />BLACK TEXT <br />EQUIPMENT SYSTEM <br />GREEN PLATE <br />WHITE TEXT <br />GENERATOR DISTRIBUTION <br />PURPLE PLATE <br />WHITE TEXT <br />2. SECURE NAMEPLATE TO SURFACES WITH TWO (2) 5/32" FLAT HEAD BRASS SCREWS. <br />PANELBOARD NAMEPLATES <br />NOT TO SCALE <br />GROUNDING ELECTRODE n <br />CONDUCTOR. CONNECT TO <br />BUILDING STRUCTURE AND MA <br />WATER LINE. (1) #250 kcmil AL. <br />5/8" x 10'-0" CU GROUND ROD, <br />MINIMUM 10'-0" APART <br />EQU I. <br />REFEF <br />UTILITY TRANSFORMER GENERATOR <br />MDP LOAD <br />A CIRCUIT BREAKER <br />0 A CIRCUIT BREAKER <br />MAIN SERVICE AND GENERATOR GROUNDING DETAIL <br />� NOT TO SCALE <br />DETAIL NOTES <br />1. RECEPTACLE IN NEMA 311 ENCLOSURE. ENCLOSURE SHALL REMAIN <br />WEATHER PROOF WHEN RECEPTACLE IS IN USE <br />2. 3/4" RIGID STEEL CONDUIT <br />3. GROUND <br />4. 1-5/8" GALVANIZED UNISTRUT SUPPORT, 36" LONG, 6" A.F.G. TO <br />BOTTOM OF RECEPTACLE. <br />WEATHERPROOF RECEPTACLE <br />NOT TO SCALE <br />EMERGENCY GENERATOR PLAN <br />R766 (30.2) TYP. DOOR SWING <br />CONCRETE SLAB <br />R746 (29.4) TYP. DOOR SWING <br />EMERGENCY GENERATOR :::�\\ AIR <br />BOND TO GENERATOR ENCLOSURE <br />GENERATOR ENCLOSURE AIRn \, AIR <br />COPPER -CLAD GROUND <br />d d - - - ° da <br />ROD. HARGER CATALOG <br />III Ns 5810. (TYPICAL) <br />d, <br />BOND TO FUEL OIL TANK AND <br />GENERATOR FRAME <br />MAIN LIGHTNING CONDUCTOR. <br />DISCHARGE AIR <br />HARGER CATALOG N2 29R. <br />34 ' <br />SOLID COPPER AIR TERMINALMARGER <br />— AIR U AIR U AIR <br />CATALOG Ns 63. (TYPICAL) <br />AIR TERMINAL (TYPICAL) <br />MAIN LIGHTNING CONDUCTOR <br />AIR INTAKE <br />ADHESIVE CABLE HOLDER. HARGER <br />AIR 10" TYP <br />LIGHTNING PROTECTION, INC. <br />CATALOG Ns 262. (TYPICAL) <br />AIR TERMINAL BRACE <br />HARGER CATALOG Ns 140 AD. <br />(TYPICAL) <br />ACCESS PANEL <br />GENERATOR CONTROL PANEL <br />0wo12" <br />REFER TO STRUCTURAL ENGINEERING <br />DRAWINGS FOR CONCRETE PAD SIZING <br />REQUIREMENTS. <br />GRADE <br />EMERGENCY GENERATOR ELEVATION <br />NOTE: WHEN GENERATOR ENCLOSURE IS 48" OR GREATER, PROVIDE ONE <br />AIR TERMINAL ON EACH CORNER. <br />MAXIMUM SPACING OF AIR TERMINALS SHALL NOT EXCEED 20'-0" <br />AND SHALL BE LOCATED WITHIN <br />24" OF THE GENERATOR SET PERIMETER. <br />EMERGENCY GENERATOR ELEVATION AND <br />LIGHTNING PROTECTION SYSTEM REQUIREMENTS <br />NOT TO SCALE <br />0 <br />C <br />'i <br />O <br />O <br />0) <br />~ <br />Ln <br />z <br />470OQ <br />c <br />oM <br />V <br />m <br />tj <br />cV <br />N <br />tj <br />�� <br />w� <br />C9CU <br />W <br />C <br />LL <br />w° <br />a <br />H <br />z <br />-z <br />O <br />(Dt <br />0 <br />z <br />IL <br />IL <br />wLLI <br />w <br />Z <br />m <br />cV <br />a <br />cV <br />00 <br />— <br />M <br />t <br />fV <br />U <br />o <br />� <br />Z <br />cM <br />M <br />v <br />CU <br />W <br />N <br />— <br />•� <br />> <br />O <br />J <br />Q <br />LL <br />u <br />W <br />L <br />o <br />4- <br />i <br />3 <br />w <br />L <br />u <br />W <br />d <br />N <br />m <br />W <br />2 <br />.4 <br />u <br />Q <br />J <br />J <br />x <br />a <br />W <br />N <br />W <br />O <br />O <br />Q <br />ZO <br />cm <br />W <br />z <br />a <br />-a <br />Ln <br />cm <br />M <br />W <br />crm <br />'C <br />G <br />a <br />m <br />•° <br />'i <br />o <br />W <br />�w <br />�^ <br />W <br />L <br />a <br />M <br />t <br />t <br />z <br />a <br />MN <br />GO.Ewls ilo <br />�s0 <br />• �( No 38680 <br />44/ <br />i Q�•. -STATE OF •��<(/ <br />�� � •'•.'�CORIDP ••'G\ \� <br />"'%ss/ON A\- 0\\. <br />////1111110 <br />George Johnson, P.E. <br />PE 38680 <br />ISSUE DATE: 10/19/2018 <br />PROJECT NUMBER: 2847 <br />REVISIONS: <br />NO. DATE DESCRIPTION <br />ELECTRICAL DETAILS <br />NOT TO SCALE <br />TO THE BEST OF THE ENGINEERS KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER 553.79 AND CHAPTER 633, FLORIDA STATUTES. <br />© 2018APG ENGINEERIN, <br />E301 <br />
The URL can be used to link to this page
Your browser does not support the video tag.