Z Y <br />7 W <br />Q U <br />>- 5.: F <br />Co a <br />Z LU 0 <br />3uz <br />i oc <br />ova <br />IFj <br />cvus <br />Classified by <br />underwriters Laboratories, Inc. <br />to UL 1479 and CAN/ULCS115 <br />System No. C-AJ-1184 <br />ANSI/UL1479 (ASTM E814) <br />CAN/ULC S115 <br />F Rating — 3 Hr <br />F Rating — 3 Hr <br />T Rating — 0 Hr <br />FT Rating — 0 Hr <br />FH Rating — 3 Hr <br />FTH Rating — 0 Hr <br />1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m') concrete. Wall <br />may also be constructed of any UL Classified Concrete Blocks*. Floor may also be constructed of any min 7-1/2 in. (190 mm) thick UL Classified <br />hollow core Precast Concrete Units*. Max diam of opening is 14 in. (356 mm) when concrete floor or wall is used and max 7 in. (178 mm) when <br />precast concrete units are used. <br />See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. <br />2. Through -Penetrants — One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The <br />annular space between pipe, conduit or tubing and periphery of opening shall be min 0 in. (point contact) to max 3-1/4 in. (83 mm). Pipe, conduit <br />or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes, conduits or tubing may <br />be used: <br />A. Steel Pipe — Nom 10 in. (254 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe — Nom 10 in. (254 mm) diam (or smaller) cast or ductile iron pipe. <br />C. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing or steel conduit. <br />D. Copper Tubing — Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing. <br />E. Copper Pipe — Nom 4 in. (102 mm) diam (or smaller) regular (or heavier) copper pipe. <br />3. Forms — (Not Shown, Optional) — Used as a form to prevent leakage of fill material during installation. Forms to be rigid sheet material, cut to fit <br />the contour of the penetrating item and positioned as required to accommodate the required thickness of fill material. Forms to be removed after <br />fill material has cured. Additional forming material may be used concrete block wall is penetrated. A min 1/2 in. (13 mm) thickness of min 4 pcf <br />(64 kg/m') mineral wool batt insulation is firmly packed into the annulus as a permanent form and recessed from both surfaces of the wall as <br />required to accommodate the required thickness of fill material. <br />4. Fill, Void or Cavity Material* — Sealant — Min 1 in. (25 mm) thickness of fill material applied within the annulus. At the point contact location <br />between through penetrant and concrete, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at the concrete through penetrant <br />interface. When precast concrete units are used, the fill material shall be installed within annular space, flush with lower surface of floor. When <br />concrete block wall is penetrated, a min 1 in. (25 mm) thickness of fill material shall be applied within the annulus flush with both surfaces of wall. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS605, FS-ONE Sealant or FS-ONE MAX Intumescent Sealant <br />* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), <br />respectively. <br />Reproduced by HILTI, Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />Hilti Firestop Systems January07,2015 <br />FLOOR OR WALL PENETRATIONS <br />IFj <br />c V� us <br />Classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CAN/ULC-S115 <br />System No. W-L-1054 <br />ANSI/UL1479 (ASTM E814) <br />CAN/ULC S115 <br />F Ratings —1 and 2 Hr (See Items 1 and <br />F Ratings —1 and 2 Hr (See Items 1 and <br />3) <br />3) <br />T Rating — 0 Hr <br />FT Rating — 0 Hr <br />L Rating at Ambient — Less Than 1 <br />FH Ratings —1 and 2 Hr (See Items 1 <br />CFM/sq ft <br />and 3) <br />L Rating at 400 F — Less Than 1 CFM/sq <br />FTH Rating — 0 Hr <br />ft <br />FTH Rating — 0 Hr <br />L Rating at Ambient — Less Than 1 <br />CFM/sq ft L Rating at 400 F — Less Than <br />1 CFM/sq ft <br />1. Wall Assembly — The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified <br />in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction <br />features: <br />A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) <br />lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. When steel studs are <br />used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed <br />between the vertical studs and screw -attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. (102 to 152 <br />mm) wider and 4 to 6 in. (102 to 152 mm) higher than the diam of the penetrating item such that, when the penetrating item is installed in the <br />opening, a 2 to 3 in. (51 to 76 mm) clearance is present between the penetrating item and the framing on all four sides. <br />B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 It (122 cm) wide with square or tapered edges. The gypsum board type, thickness, number of <br />layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance <br />Directory. Max diam of opening is 32-1/4 in. (819 mm) for steel stud walls. Max diam of opening is 14-1/2 in. (368 mm) for wood stud walls. <br />The F and FH Ratings of the firestop system are equal to the fire rating of the wall assembly. <br />2. Through -Penetrants — One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The <br />annular space shall be min 0 in. to max 2-1/4 in. (57 mm). Pipe may be installed with continuous point contact. Pipe, conduit or tubing may be <br />installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tubing to be rigidly supported on both sides of wall <br />assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: <br />A. Steel Pipe — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe — Nom 30 in. (762 mm) diam (or smaller) cast or ductile iron pipe. <br />C. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing or 6 in. (152 mm) . diam steel conduit. <br />D. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. <br />E. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) regular (or heavier) copper pipe. <br />3. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces of <br />wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at the <br />pipe wall interface on both surfaces of wall. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant <br />* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), <br />respectively. <br />Reproduced by HILTI, Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />Hifd Firestop Systierins <br />January 23, 2015 <br />WALL PENETRATIONS <br />CV <br />c V� us <br />Classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CAN/ULC•S115 <br />System No. C-AJ-1421 <br />ANSI/UL1479 (ASTM E814) <br />CAN/ULC S115 <br />F Ratings — 2 or 3 Hr <br />F Ratings — 2 or 3 Hr <br />T Rating — 0 Hr <br />FT Rating — 0 Hr <br />L Rating at Ambient — Less Than 1 <br />FH Ratings — 2 or 3 Hr <br />CFM/sq ft <br />L Rating at 400 F — Less Than 1 <br />FTH Rating — 0 Hr <br />CFM/sq ft <br />L Rating at Ambient — Less Than 1 <br />CFM/sq ft <br />L Rating at 400 F — Less Than 1 <br />CFM/sq ft <br />SECTION A -A <br />1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m') concrete. Wall <br />may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 6 in. (152 mm). <br />See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. <br />2. Metallic Sleeve — (Optional) Nom 6 in. (152 mm) diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, <br />flush with floor or wall surfaces. <br />3. Through -Penetrant — One metallic pipe or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space <br />between pipe, tube or conduit and periphery of opening shall be min 0 in. (pant contact) to max 5-318 in. (137 mm). Pipe or conduit to be rigidly <br />supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or conduits may be used: <br />A. Steel Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe — Nom 4 in. (102 mm) diam (or smaller) cast or ductile iron pipe. <br />C. Copper Pipe — Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe. <br />D. Copper Tubing — Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing. <br />E. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel conduit. <br />F. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT). <br />4. Firestop System — The firestop system shall consist of the following: <br />A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m') mineral wool batt insulation firmly packed into opening as a permanent <br />form. Packing material to be recessed from top surface of floor or from both surfaces of wall to accommodate the required thickness of fill <br />material. <br />B. Fill, Void or Cavity Material* - Sealant — Min 1/4 in. (6 mm) thickness of fill material applied within the annulus, flush with top surface of floor or <br />with both surfaces of wall. For 3 Hr rated assemblies, a min 1/4 in. (6 mm) diam bead of fill material shall be applied at the concrete/pipe <br />interface at the point contact location on the top surface of floor and on both surfaces of wall. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CFS-S SIL GG, CFS-S SIL SL, FS-ONE Sealant, FS-ONE MAX Intumescent <br />Sealant or CP604 Self -Leveling Firestop Sealant. CP604 and CFS-S SIL SL shall be used in floor applications only. <br />When CP604, CFS-S SIL GG or CFS-S SIL SL (floors only) is used, F Rating is 2 Hr. <br />* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), <br />respectively. <br />Reproduced by HILTI, Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />Hilti Firestop Systems January 28, 2015 <br />FLOOR OR WALL PENETRATIONS <br />NOT TO SCALE I NOT TO SCALE I �`�� NOT TO SCALE <br />(A <br />tki <br />r- <br />Lr) <br />r- <br />0 <br />Z <br />C <br />0 <br />0) <br />•4) <br />0 <br />5 <br />5 <br />Ln <br />ZU <br />E-MM(> <br />_ <br />Z <br />Ln <br />Ln <br />N <br />N <br />�ti <br />n <br />n <br />LU`° <br />W <br />C <br />U_ <br />W� <br />~ <br />3 <br />� <br />Z <br />Z <br />O <br />(5 <br />b <br />O <br />Z <br />IL <br />IL <br />WUJI <br />IX <br />LL <br />l7 <br />Z <br />m <br />N <br />J <br />a <br />N <br />00 <br />— <br />m <br />t <br />a <br />on <br />W <br />Z <br />can <br />M <br />LUN <br />W <br />CCU <br />— <br />> <br />_O <br />J <br />CU <br />Q <br />Ll <br />u <br />QU <br />L <br />L <br />o <br />q <br />-J <br />= <br />3 <br />LU <br />Ln <br />U <br />W <br />a <br />N <br />cv <br />(11 <br />Q <br />dam' <br />V <br />a <br />W <br />IV <br />W <br />O <br />O <br />Q <br />Iflc <br />Z <br />O <br />LU <br />Z <br />-p <br />Ln <br />M <br />M <br />LU <br />V <br />C <br />a <br />'% <br />o <br />W <br />>%� <br />4 1 <br />�^ <br />LU <br />L. <br />a <br />M <br />L <br />L <br />.c <br />z <br />00 <br />M <br />a <br />N <br />\\Xj%IIIIII//// <br />o�GIP-\-EWIS JOy� <br />\\CENSF. SO <br />* ,No 38680 <br />0 TATE OF <br />George Johnson, P.E. <br />PE38680 <br />ISSUE DATE: 10/19/2018 <br />PROJECT NUMBER: 2847 <br />REVISIONS: <br />NO. DATE DESCRIPTION <br />ELECTRICAL DETAILS <br />TO THE BEST OF THE ENGINEERS KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER 553.79 AND CHAPTER 633, FLORIDA STATUTES. <br />0 2018 APG ENGINEERING <br />E302 <br />