Laserfiche WebLink
5/23/2022 12:25:57 PM <br />ELECTRICAL KEY 5YM130L <br />—4•5• HOSE BIB <br />120V DUPLEX CONVENIENCE DUPLEX <br />OUTLET.(GFI) 120V OR 240V, GFI OUTLET, <br />(W)WEATHERPROOF DUPLEX RECEPTACLE <br />w/ GFI. (AR) ARC FAULT CIRCUIT <br />INTERRUPTER <br />220V OUTLET <br />120V DUPLEX CONVENIENCE RECEPTACLE, <br />+48, + 72" FOR MICRO -HOOD, IN <br />ATTIC(DASHED) <br />120V DUPLEX CONVENIENCE DUPLEX <br />RECEPTACLE, CEILING MOUNTED - GARAGE <br />14 DOOR OPENER <br />-�- SWITCHES <br />3-WAY SWITCH <br />KD <br />WALL MOUNT FIXTURE <br />GARAGE DOOR PUSH BUTTON <br />® 48" FLUORESCENT/LED LIGHT FIXTURE <br />GENERAL ELECTRICAL NOTES: <br />1) PER NEC SECTION 210.12(5) ALL 15A * 20A, 120V BRANCH <br />CIRCUITS SUPPLYING OUTLETS REQUIRE AFCI PROTECTION. <br />2) CARBON MONOXIDE PROTECTION PER FLORIDA 5TATUTE5 <br />553.585 (2). TO BE INSTALLED WITHIN 10' OF EVERY SLEEPING <br />ROOM. <br />3) PER NEC SECTION 210.8(5)(4) ALL 15A * 20A, 125V <br />RECEPTACLES INSTALLED OUTDOORS MUST BE GFI-PROTECTED. <br />4) PER NEC SECTION 210.8(13)(5) ALL 15A * 20A, 125V <br />RECEPTACLES INSTALLED WITHIN G' OF A SINK (IN NON -DWELLING <br />UNIT OCCUPANCIES-i.e. OUTDOOR SUMMER KITCHENS <br />RECEPTACLES) MUST BE GFCI-PROTECTED. <br />5) PER NEC SECTION 40G.8(5)(1) 15A * 20A RECEPTACLES IN A <br />WET LOCATION MUST BE WITHIN AN ENCLOSURE THAT IS <br />WEATHERPROOF WHEN AN ATTACHMENT 15 PLUGGED IN AND ALL <br />NON -LOCKING RECEPTACLES SHALL BE LISTED AS WEATHER <br />RESISTANT. <br />G) PER NEC SECTION 40G.11 IN DWELLING UNITS, ALL 15A * 20A, <br />125V RECEPTACLES SHALL BE LISTED AS TAMPER -RESISTANT. <br />7) PER NEC SECTION 800.15G NO LE55 THAN ONE <br />COMMUNICATIONS OUTLET SHALL BE INSTALLED WITHIN EACH <br />DWELLING UNIT. <br />8) PER NEC SECTIONS R3,14.3 AND R315.1 SMOKE DETECTORS TO <br />BE INSTALLED IN51DE EA SLEEPING AREA <br />9) PROVIDE GAS DROPS AS PER SPECIFICATIONS. <br />10) PRE -WIRE FOR OPTIONAL CEILING FAN PER SPECIFICATIONS. <br />CENTER JUNCTION BOX IN ROOM. <br />11) JUNCTION BOX AT WATER HEATER, RANGE AND /OR DRYER TO <br />BE 220v WHERE GAS IS NOT AN OPTION, AND IIOv WHEN GAS 15 <br />AN OPTION. PROVIDE APPROPRIATE RECEPTACLE PER APPLIANCE <br />12) PROVIDE ADDITIONAL EXTERIOR WEATHERPROOF RECEPTACLE <br />WIN 15' OF CONDEN51NG UNITS <br />13) ALL GARAGE OUTLETS SHALL BE ON A DEDICATED CIRCUIT. <br />14) ELECTRICAL RECEPTACLE, SWITCH QUANTITIES * LOCATIONS <br />SHOWN ON PLAN ARE FOR ILLUSTRATION PURPOSES ONLY. <br />ACTUAL NUMBER * LOCATIONS SHALL BE FIELD DETERMINED AS <br />PER CLIENT * BUILDER EXCEPT WHERE CODE REQUIREMENTS <br />APPLY, <br />ALL ELECTRICAL DESIGN AND WORK SHALL BE IN STRICT <br />COMPLIANCE WITH THE 2014 NEC /NFPA 70 <br />ALL ELECTRICAL DESIGN AND WORK SHALL BE IN STRICT <br />COMPLIANCE WITH THE FBC ENERGY CONSERVATION R404. <br />z <br />J <br />2 <br />V) <br />z <br />w <br />0 <br />JUDITH ANN KOEHN, CPBD, AIBD <br />AKOHN @ONTWERPESTUDIO.COM <br />727.400.9459 1 910.374.78G3 <br />WWW.ONTWERPE5TU DI O.COM <br />N•C-B•D•C <br />MEMBER <br />Creating where people live A I <br />B Q_, <br />AMERICAN E of <br />BUILDING- DESIGN <br />N <br />Ln <br />0 <br />m <br />W <br />O <br />m <br />C <br />0 <br />— <br />Q <br />V <br />0 <br />0 <br />LL <br />Q <br />�- <br />UJ <br />lU <br />- <br />m <br />J <br />J <br />Ln <br />!L <br />W <br />N <br />REV DATE DESCRIPTION <br />- - <br />z <br />3 <br />PROJECT NO: 2204-25G <br />DATE: 23.05.2022 <br />DRAWN BY: A. KOHN <br />"CONSTRUCTION DOCUMENTS ARE ORIGINAL <br />AND UNPUBLISHED MATERIALS OF THE <br />DESIGNER, THEY SHALL NOT BE COPIED IN <br />ANY FORM WITHOUT THE EXPRESSED <br />WRITTEN CONSENT OF THE DESIGNER. <br />0 2' 4' 8' ELECTRICAL PLAN <br />ELECTRICAL PLAN I m SCALE. 114„ = 1'-0" E I.O <br />-- - <br />- i __1_1i 11T--. "C iL e a➢7I P i ]TM lt�:i i :n.. � i -� - -. T- I I I <br />