Laserfiche WebLink
TRU55 5Y5TEM REQUIREMENTS <br />FL (2020 FDC), WIND: 140-150 MPH <br />I ALL PRE-ENGINEERED WOOD PRODUCTS SHALL BE VERIFIED BY TRUSS <br />MANUFACTURER. TRU55 MANUFACTURER SHALL HAVE THE AUTHORITY TO MAKE <br />SUB5TITUTIONS FOR PRODUCTS SPECIFIED ON THE PLANS DUE TO AVAILABILITY <br />OR ECONOMICS. CHANGES SPECIFIED BY THE TRUSS MANUFACTURER SHALL <br />CONTROL. CHANGES MADE AFTER TRUSS ENGINEERING HAS BEEN PROVIDED TO <br />ENGINEER OF RECORD, MUST BE APPROVED BY THE ENGINEER OF RECORD, <br />2 TRUSS MANUFACTURER TO PROVIDE SEPARATE LAYOUT AND TRUSS <br />COMPONENT DE51GN SIGNED AND SEALED BY A FLORIDA REGISTERED <br />PROFESSIONAL ENGINEER. <br />3 ALL PRE-ENGINEERED WOOD PRODUCTS ARE THE RESPONSIBILITY OF THE TRU55 <br />MANUFACTURER. THE TRUSS ENGINEER 15 A DELEGATED ENGINEER FOR THIS <br />PROJECT, AND AS SUCH, 15 RESPONSIBLE FOR THE VALIDITY OF THE <br />COMPONENTS PROVIDED. FRAMING LAYOUTS SHOWN MAY BE CHANGED BY THE <br />TRUSS MANUFACTURER, THE DELEGATED ENGINEER 15 RESPONSIBLE FOR <br />PROVIDING A FINAL 5EALED SET OF ALL CALCULATIONS AND LAYOUTS FOR THIS <br />PROJECT TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO MANUFACTURE <br />OF SAID COMPONENTS. ENGINEER OF RECORD HAS NOT REVIEWED THE <br />PRE-ENGINEERED TRUSS MANUFACTURER'S COMPONENTS AT THIS TIME AND <br />RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER SUCH INFORMATION HAS <br />BEEN PROVIDED FOR REVIEW. CONTRACTOR, AS PROJECT COORDINATOR, <br />SHALL BE RESPONSIBLE FOR INSURING INFORMATION REQUESTED ABOVE HAS <br />BEEN SUBMITTED TO ENGINEER OF RECORD IN A TIMELY MANNER WHEN <br />AVAILABLE. <br />4 ALL PRE-ENGINEERED TRUSSES TO BE DESIGNED U51NG THE M05T RECENT TPI <br />CRITERIA, TRUSSES TO BE HANDLED AND INSTALLED U51NG M05T RECENT 15C51 <br />RECOMMENDATIONS. TEMPORARY AND PERMANENT BRACING SHALL BE PER <br />M05T RECENT 15C51 RECOMMENDATIONS UNLE55 NOTED OTHERWISE, OR MORE <br />STRINGENT CODE REQUIREMENTS APPLY, TRU55 ENGINEER 15 RESPONSIBLE FOR <br />INDICATING ALL TRU55 TO TRU55 CONNECTORS. ALL COMPONENTS TO BE <br />DESIGNED FOR BOTH GRAVITY AND UPLIFT LOAD CASES, INCLUDING BEAM <br />COMPONENT5.UPON REVIEW, ENGINEER OF RECORD WILL PROVIDE A REVIEW <br />LETTER INDICATING ANY CHANGE IN STRAPPING OR SUPPORT BASED ON THAT <br />REVIEW. CONSTRUCTION COMMENCING PRIOR TO ENGINEER'S REVIEW 15 <br />SUBJECT TO MODIFICATION BASED ON REVIEW LETTER. <br />5 ALL METAL CONNECTORS * FABRICATIONS SHALL COMPLY w/ A15C SPECS. <br />6 SOLID BLOCK ALL J015T $ RAFTERS AT POINTS OF SUPPORT. <br />7 CONTRACTOR SHALL CORRELATE w/ TRUSS MANUFACTURER TO ENSURE <br />ADEQUATE BEARING 15 PROVIDED AT END REACTIONS OF ALL GIRDER TRUSSES. <br />8 CONTRACTOR SHALL PROVIDE ALL FASTENING DEVICES NECESSARY * SUITED <br />FOR EACH APPLICATION AND BE RESPONSIBLE FOR ITEMS TO BE INSTALLED <br />CORRECTLY, <br />9 BRACE TRUSSES DURING ERECTION * AFTER PERMANENT INSTALLATION TO <br />COMPLY w/ TPI BWT-76 <br />10 ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT w/ MASONRY, <br />CONCRETE OR 501L SHALL BE PRESSURE -TREATED. <br />11 ALL WOOD FRAMING SHALL BE FABRICATED * INSTALLED PER AITC AND TPI <br />NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. <br />12 ROOF SHEATHING: EXPOSURE B, 7/16" W5P. EXPOSURE C, 10/32" W5P. ATTACHE <br />w/ 8d COMMON NAILS w/ 6:12 NAILING PATTERN PERIMETER EDGE ZONE (48") <br />NAILING TO BE 4:4 NAILING PATTERN (INSTALL BLOCKING IN PERIMETER EDGE <br />ZONE AT 48" O.C.) <br />13 ALL TRUSSES SHALL BE DESIGNED FOR BEARING ON SPF#2 OR #3 PLATES OR <br />LEDGERS (UNO) <br />DE51GN NOTE <br />FRAMING PLAN 15 DIAGRAMMATIC IN NATURE AND 15 PROVIDED FOR ILLUSTRATION <br />PURPOSES ONLY. TRUSS MANUFACTURER TO PROVIDE SEPARATE LAYOUT AND <br />TRU55 COMPONENT DE51GN SIGNED AND SEALED BY A NORTH CAROLINA <br />REGISTERED PROFESSIONAL ENGINEER, <br />NOTE: FOR MUST REVIEW AND APPROVE TRUSS PLANS PRIOR TO THE START OF ANY <br />CONSTRUCTION. TRU55 CONNECTORS, FOUNDATION , AND BEARING WALLS ALL <br />SUBJECT TO CHANGE BA5ED ON TRUSS PLANS <br />NOTE: ROOFING TRU55E5 5Y OTHERS <br />HEADER/BEAM * COLUMN NOTES: <br />THE NUMBER SHOWN AT BEAM AND HEADER SUPPORTS INDICATES THE NUMBER OF <br />SUPPORT STUDS REQUIRED IN STUD POCKET OR COLUMN. THE NUMBER OF KING <br />STUDS AT EACH END OF THE HEADERS IN LOAD BEARING AND EXTERIOR WALLS SHALL <br />BE ACCORDING TO ITEM (d) IN TABLE R602.3(5) OR AS BELOW <br />UP TO 4': 1 KING STUD <br />41-81 2 KING STUDS <br />8'-II' 3 KING 5TUD5 <br />OVER 11' 4 KING STUDS <br />HEADER AT LOAD BEARING WALLS: <br />2X4 WALLS (2) 2X10 (U.N.O.) <br />2XG WALLS (3) 2XIO (U.N.O.) <br />USE (1) JACK AND (1) KING STUD AT EACH END, U.N.O. <br />SEE TBL RG02.7.5 FOR FULL HGT STUDS AT EACH END IN EXTERIOR WALLS <br />NON LOAD (1) 2X4 LAID FLAT FOR OPENINGS UP TO 8' w IF VERTICAL DISTANCE <br />BEARING: TO PARALLEL NAILING SURFACE 15 NOT MORE THAN 24" <br />USE (1) JACK AND (1) KING STUD AT EACH END <br />HEADER HEIGHT NOTE: <br />ALL WINDOW HEAD HEIGHTS ARE 0-8" A.F.F. UNLE55 NOTED OTHERWISE. <br />TYPICAL 51MP50N <br />HANGERS <br />ITEM NUMBER MODEL FA5TNER5 <br />UPLIFT# <br />SHEAR <br />NOTES <br />JACK TRUSSES WD. TO HETA20 16-10d X 1-1/2" <br />1890 <br />271/625 <br />MASONRY <br />BEAM5/HIP <br />GIRDER/COMMON <br />HETA20 32-IOd X I-1/2" <br />2,646 <br />540l1,250 <br />(2) STRAP / <br />TRUSSES WD. TO <br />TRU55 / GIRDER <br />MA50NRY <br />COMMON TRU55E5 HU526 28-I0d <br />1,550 <br />- <br />HANGER <br />(HANGERS) <br />GIRDER TO GIRDER HGU5210-2 62-16d <br />3,080 <br />- <br />HANGER <br />(HANGERS) <br />WOOD TO WOOD NO 16-8d X 1-1/2" <br />850 <br />505/450 <br />WOOD / WOOD <br />VALLEY TRUSSES / LU528-2 10-16d <br />1,140 <br />1.265 <br />FRAMING <br />HIP GIRDER HETA16 32-10d X I-I/2" <br />2,500 <br />1.210 <br />(2) STRAP PER1,160 <br />MANUF. <br />WOOD TO WOOD GIRDER MT518 28-I06 X 1-1/2" <br />2,000 <br />- <br />(2) STRAPS <br />" OR EQUAL <br />T/C TAPCON CONCRETE FA5TNER5 <br />LOADS TAKEN FROM MANUFACTURERS SPECIFICATIONS <br />ACTUAL LOADS MAY BE LE55 <br />NOTE: SEE 2ND FLOOR PLAN AT PLUMB DOWNS <br />UNLE55 NOTED OTHERWISE PER NOTE OR DETAIL <br />a <br />N, <br />Lu <br />w <br />z <br />0 <br />z <br />w <br />ry <br />n <br />a <br />5 H EAR WALL NOTE <br />ALL EXTERIOR WALLS ARE TO BE CON5IDERED <br />SHEAR RF-515TING COMPONENTS. <br />ROUGH OPENING <br />NOTE: <br />FIELD VERIFY MASONRY AND FRAME OPENINGS <br />OF WINDOWS AND DOORS WITH MANUFACTURE <br />SPECIFICATIONS. <br />MINIMUM ROOF SHEATHING <br />THICKNE55 <br />WIND <br />SPEED <br />RAFTER/TRU55 SPACING <br />150 <br />140 <br />24 IN, O.C. <br />7/16 <br />15/32 <br />(24/16) <br />15/32 <br />(32/16) <br />19/32 <br />MINIMUM SHEATHING THICKNESS, INCHES <br />(PANEL SPAN RATING) EXPOSURE C <br />(40/20) <br />(40120) <br />MINIMUM SHEATHING THICKNESS, INCHES <br />19/32 <br />0/32 <br />(PANEL SPAN RATING) EXPOSURE D <br />(40/20) <br />(40/20) <br />ROOF SHEATHING ATTACHMENT <br />WIND SPEED <br />RAFTER/TRU55 SPACING <br />140 150 <br />24 IN, O.C. <br />E F E F <br />EXPOSURE B <br />RAFTER/TRU55 5G = 0.42 6 6 6 6 <br />RAFTER/TRU55 5G = 0.45 <br />6 <br />6 <br />6 <br />6 <br />EXP05URE C <br />RAFTER/TRU55 SG = 0.42 1 4 1 4 1 4 4 <br />RAFTER/TRU55 5G = 0.49 <br />6 <br />6 <br />6 <br />6 <br />EXPOSURE D <br />WTERlTRU55 5G = 0.42 4 4 4 4 <br />RAFTERfTRU55 5G = 0.49 <br />6 <br />6 <br />4 <br />4 <br />E = NAIL SPACING ALONG PANEL EDGES (INCHES) <br />F = NAIL SPACING ALONG INTERMEDIATE SUPPORTS IN THE PANEL FIELD <br />(INCHES) <br />a.FOR SHEATHING LOCATED A MINIMUM OF 4 FEET FROM THE PERIMETER <br />EDGE OF THE ROOF, INCLUDING 4 FEET ON EACH 51DE OF RIDGES AND HIPS, <br />NAIL SPACING 15 PERMITTED TO BE 6 INCHES ON CENTER ALONG PANEL <br />EDGES AND 6 INCHES ON CENTER ALONG INTERMEDIATE SUPPORTS IN THE <br />PANEL FIELD. <br />b.WHERE RAFTER/TRU55 SPACING 15 LE55 THAN 24 INCHES ON CENTER, <br />ROOF SHEATHING FASTENING 15 PERMITTED TO BE IN ACCORDANCE WITH <br />THE AWC WPCM OR THE AWC ND5. <br />VENT AREA <br />I'-4" 26'-0" I'-4" <br />879 SQ. FT- <br />ROOF FRAMING PLAN <br />ATTIC VENT CALCULATION <br />PROVIDE ATTIC VENTILATION IN COMPLIANCE W/ F.B.0 RESIDENTIAL CODE. THE <br />REQUIRED NET FREE VENTILATING AREA OF NOT LESS THAN 1/150 OF THE SPACE <br />VENTILATED. AREA MAY BE REDUCED TO 1/300 PROVIDED THAT 50 PERCENT (BUT <br />NOT MORE THAN 80%) OF THE REQ'D VENTILATING AREA IS PROVIDED IN THE UPPER <br />PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET ABOVE EAVE OR <br />CORNICE WITH THE BALANCE OF THE REQ'D VENTILATION PROVIDED BY THE EAVE <br />OR CORNICE VENTS. <br />NOTE: TYPICAL VENTILATION INCLUDES <br />1. SOFFIT VENTS <br />(AREA: 6.42 SQ.IN. PER FOOT- VERIFY W/ MANUFACTURER) <br />2. LOMANCO 770* ATTIC VENT LOCATED 12" MIN. FROM RIDGE <br />(AREA: 70 SQ. IN. - VERIFY W/ MANUFACTURER). <br />*(1) LOMANCO 770D VENT AT 140 S.I. EA CAN BE USED IN PLACE OF (2) 770 VENTS. <br />AREA 1 - AREA VENTILATION REQUIRED - UPPER & LOWER VENTS PROVIDED <br />879 S.F. ATTIC AREA / 300 = 2.93 S.F. X 144 = 421.92 S.I. <br />421.92 S.I. / 2 = 210.96 S.I. UPPER AND LOWER VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />4 LOMANCO OFF RIDGE VENTS AT 70 S.I. EA. = 280.00 > 210.96 S.I. <br />LOWER VENTILATION PROVIDED <br />33 FT. SOFFIT VENTS (MIN.) AT 6.42 SI./FT = 211.86 > 210.96 S.I. <br />2 0-0" <br />41-011 1. 21-0" 1. 41-011 1. 41-011 1. 4'-011 1 41-01' I 41-011 <br />II <br />- - <br />#5DI.0) <br />IWASHERII DRYER <br />I <br />m <br />I ROUGH OPENING NOTE. I <br />INDICATES OPENING VIF MA50NRY4 FRAME OPENING5 <br />OF WINDOWS * DOORS w/ MANUF. <br />IN WALL ABV <br />SDLO <br />4" THICK, 2500 P.5.1, CONCRETE <br />SLAB ON GRADE W/ 6x6 WELDED <br />WIRE MESH OR FIBER ME5H OVER I <br />I 6 MIL VAPOR BARRIER ON CLEAN, I <br />Q <br />I WELL- COMPACTED, TERMITE I <br />I TREATED, GRANULAR FILL. -TYPICAL <br />I <br />i Lu <br />o <br />I o� I <br />o <br />Q <br />I <br />INDICATES I - #5 VERT. REBAR <br />IN MASONRY CELL FILLED SOLID <br />I W/ CONCRETE. VERT. REINF. <br />O <br />SHALL BE HOOKED INTO BEAM I <br />ABV * FTG. BELOW PROVIDE 25" I <br />`t <br />MIN. LAP WHERE 5PLICED/WIRE <br />TOGETHER. TYPICAL I <br />I <br />5 <br />p <br />I SDLO 5DI.0 5DI.0L4 I <br />o <br />------------------------ - -� <br />FOUNDATION PLAN <br />no <br />[_ SLAB LEGEND <br />x 2 INDICATES RECESS IN 5LA5 <br />E _ ] INDICATES OPENING ABV <br />INDICATES STEP DOWN AND <br />MEASUREMENT IN SLAB <br />INDICATES 145 VERTICAL REBAR <br />■IN GROUTED FILLED CELL IN NEW <br />5" CMU WALL(5HEAR WALL <br />5ECRTON). FILL 50LID FROM FTG <br />TO TIE BEAM <br />AtINDICATES 245 VERTICAL <br />REBAP, FILL 50LID FROM FTG TO <br />TIE BEAM <br />NOTE: <br />VERT, REINF. SHALL HOOK INTO BEAM <br />ABOVE * FOOTING BELOW, PROVIDE 25" <br />MIN. LAP WHERE SPLICES OCCUR, AND <br />WIRE TOGETHER. <br />FILLED CELLS NOTE: <br />FILLED CELLS NEXT TO ALL CORNERS, <br />NEXT TO ALL OPENINGS, UNDER ALL <br />GIRDERS, @ ALL CORNERS, AND 48" O.C. <br />MAXIMUM. <br />"CONTRACTOR TO VIF ALL EXISTING <br />FILLED CELLS -TYP <br />7 <br />z JUDITH ANN KOEHN, CPBD, AIBD <br />> AKOHN@ONTWERPE5TUDIO.COM <br />727.490.9459 1 910.374.7863 <br />p WWW.ONTWERPE5TUDIO.COM <br />z <br />w N-C-B-D'C <br />0 • NATIONAL COUNCIL OF • <br />o <br />0 <br />�� oP <br />4 <br />� r <br />Judith Ann Koehn <br />cEUWICATI - 10.267 <br />W TM <br />MEMBER <br />Creating where peape live A L <br />B.D� <br />: <br />AMERICAN E of <br />BUILDING- DESIGN <br />N <br />It <br />Ln <br />O <br />c� <br />O <br />m <br />(WJ <br />V <br />Q <br />O <br />� <br />o <br />Q <br />0 <br />(� <br />V <br />Q <br />0 <br />Lu <br />m <br />J <br />S_ <br />L <br />In <br />=' <br />_ <br />T <br />CO <br />Q_. <br />LLJ <br />N <br />zp <br />wFA� <br />w <br />A`aoN� <br />N � <br />O <br />U <br />OQ <br />zOU <br />�CUm <br />pg w <br />rA <br />w <br />�A <br />z oxA <br />k o,V� <br />W� <br />w <br />EnO <br />�pZ <br />p A0 <br />M b <br />�E4z8 <br />F <br />� OumU <br />� <br />a <br />0 <br />0 <br />� h <br />� <br />W <br />QMN <br />Z <br />>* <br />a M <br />M <br />�l' <br />� <br />'4 '?i <br />wa x <br />W W <br />z <br />W <br />h--�i <br />R, N E-I A-i <br />REV DATE DESCRIPTION <br />2 <br />3 <br />PROJECT NO: 2204-25G <br />DATE: 23,05.2022 <br />DRAWN BY: A. KOHN <br />*CONSTRUCTION DOCUMENTS ARE ORIGINAL <br />AND UNPUBLISHED MATERIALS OF THE <br />DESIGNER, THEY SHALL NOT BE COPIED IN <br />ANY FORM WITHOUT THE EXPRESSED <br />WRITTEN CONSENT OF THE DESIGNER, <br />0 21 4' 8' 5TUCTURAL PLANS <br />SCALE: 114" = P-0" 51.0 <br />5/23/2022 12:26:03 PM <br />HI I i. I I u', H i-ii ".Ili I I II - 1111 111 111A IIII: 1i <br />