0 <br />v <br />0 <br />U �_o <br />DESIGN CRITERIA <br />1. ALL STRUCTURAL WORK SHALL CONFORM TO THE STRUCTURAL DRAWINGS AND SPECIFICATIONS AND MEET <br />THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (FBC) AND THE APPLICABLE BUILDING CODE <br />AMENDMENTS. THE ARCHITECTURAL DRAWINGS SHALL GOVERN ALL DIMENSIONS. <br />A BUILDING CODE: FBC - 6TH EDITION (2017) <br />B STRUCTURAL CONCRETE:BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE(ACI 318) <br />C STRUCTURAL STEEL:SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (AISC) <br />D CONCRETE MASONRY:BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES(ACI 530) <br />E COMPONENTS AND CLADDING LOADSWINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER <br />STRUCTURES(ASCE 7-16) <br />2. OCCUPANCY CATEGORY: II <br />3. ROOF LIVE LOADS: <br />a. BASIC ROOF LIVE LOAD 20 PSF <br />b. BASIC ROOF DEAD LOAD: 25 PSF <br />b.a. (SEE PLAN FOR ADDITIONAL DEAD LOADS OR EQUIPMENT LOADS) <br />4. WIND LOADS: <br />a. BASIC WIND SPEED (3-SECOND GUST) 140 MPH <br />b. BUILDING RISK CATEGORY II <br />c. WIND EXPOSURE "B" <br />d. INTERNAL PRESSURE COEFFICIENTS +0.18/-0.18 <br />IS. COMPONENTS AND CLADDING PRESSURE <br />5. EARTHQUAKE LOADS (-): <br />a. <br />SEISMIC IMPORTANCE FACTOR, IE <br />1.0 <br />b. <br />BUILDING RISK CATEGORY <br />II <br />c. <br />MAPPED SPECTRAL RESPONSE ACCELERATION, SS <br />.0559 <br />d. <br />MAPPED SPECTRAL RESPONSE ACCELERATION, S1 <br />.0301 <br />e. <br />SITE CLASS (ASSUMED) <br />D <br />f. <br />SPECTRAL RESPONSE COEFFICIENT, SDS <br />0.060 <br />g. <br />SPECTRAL RESPONSE COEFFICIENT, SD1 <br />0.048 <br />h. <br />SEISMIC DESIGN CATEGORY <br />A <br />1. <br />BASIC SEISMIC -FORCE -RESISTING SYSTEM <br />ORD BRACED FRAME <br />j. <br />DESIGN BASE SHEAR <br />2.00K <br />k. <br />SEISMIC RESPONSE COEFFICIENT, CS <br />0.0100 <br />I. <br />RESPONSE MODIFICATION FACTOR, R <br />1.0 <br />m. <br />ANALYSIS PROCEDURE USED <br />EQUIV. LATERAL FORCE <br />5. INTERIOR WALLS (MINIMUM LATERAL LOAD) 5 PSF <br />6. GROUND SNOW LOAD (PG = 0 PSF), N/A <br />7. SEE PLANS FOR ADDITIONAL LOADING CRITERIA. <br />GENERAL CONDITIONS <br />1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL OTHER <br />DISCIPLINES AND SPECIFICATIONS. THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER <br />TRADES AS TO SLEEVES, CHASES, HANGERS, INSERT ANCHORS, HOLES, AND OTHER ITEMS TO BE PLACED <br />OR SET IN THE STRUCTURAL WORK. <br />2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND <br />REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT ADVISE ON, NOR ISSUE DIRECTION, AS TO <br />SAFETY PRECAUTIONS AND PROGRAMS. <br />3. METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE <br />CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE <br />THE INTEGRITY AND STABILITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. THE STRUCTURE <br />SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER THE FINAL CONFIGURATION ONLY. <br />4. THE CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS AND VERIFY ALL DIMENSIONS, <br />ELEVATIONS, AND CONDITIONS PRIOR TO FABRICATION OF ANY STRUCTURAL COMPONENTS. IMMEDIATELY <br />NOTIFY THE ENGINEER AND/OR ARCHITECT OF ANY DISCREPANCIES OR CONFLICT WHERE THE INTENT OF <br />THE CONSTRUCTION DOCUMENTS ARE IN DOUBT OR WHERE THERE APPEARS TO BE A DEFECT OR <br />OMISSION IN THE CONSTRUCTION DOCUMENTS OR DISCREPANCY BETWEEN THE CONSTRUCTION <br />DOCUMENTS AND THE FIELD CONDITION. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING TO <br />OBTAIN ENGINEER'S CLARIFICATION BEFORE COMMENCING THE WORK. <br />5. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ENGINEER AND/OR ARCHITECT <br />FOR APPROVAL PRIOR TO FABRICATION OF ANY STRUCTURAL COMPONENTS. ALL CHANGES REQUIRE THE <br />WRITTEN APPROVAL OF THE ENGINEER AND/OR ARCHITECT. UNAUTHORIZED DEVIATIONS ARE THE SOLE <br />RESPONSIBILITY OF THE CONTRACTOR. <br />6. THE CONTRACTOR SHALL SHORE OR CRIB THE STRUCTURE FOR ALL CONSTRUCTION LOADS WHICH EXCEED <br />THE NOTED DESIGN LOADS. DO NOT APPLY ANY ERECTION OR CONSTRUCTION LOADS UNTIL STRUCTURAL <br />FRAMING IS PROPERLY CONNECTED TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE. <br />7. ALL STRUCTURAL WORK THAT IS COMPOSED OF COMPONENTS DESIGNED BY OTHERS SHALL BE IN <br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS AND SUPERVISED BY <br />THE MANUFACTURER'S REPRESENTATIVE(S) DURING THE MANUFACTURING, DELIVERY, HANDLING, <br />STORAGE, AND ERECTION AS REQUIRED. <br />8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT <br />SPECIFICALLY SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY <br />THE ENGINEER. <br />9. ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF THOSE STANDARDS, UNLESS <br />OTHERWISE NOTED. <br />10. COORDINATE ALL CONSTRUCTION ACCESS AND OPERATIONS FOR ALL WORK THAT OCCURS ADJACENT TO <br />AN EXISTING STRUCTURE AS NECESSARY TO AVOID DISRUPTION TO SAID STRUCTURE. <br />11. ALL STRUCTURAL CONSTRUCTION DOCUMENTS (DRAWINGS, DETAILS, CALCULATIONS, AND ALL OTHER <br />STRUCTURAL INFORMATION) PROVIDED ARE THE PROPERTY OF THE ENGINEER AND ARE FOR USE ON THIS <br />PROJECT ONLY. ANY OTHER USE OF THE STRUCTURAL CONSTRUCTION DOCUMENTS IS STRICTLY <br />PROHIBITED WITHOUT THE WRITTEN PERMISSION OF ENGINEER. <br />12. IF DRAWINGS AND CALCULATIONS ARE PROVIDED ELECTRONICALLY; COPIES OF THE ORIGINAL <br />CONSTRUCTION DOCUMENTS AS DESIGNED BY ENGINEER HAVE BEEN RETAINED BY ENGINEER. ENGINEER <br />IS NOT RESPONSIBILITY FOR ANY SUBSEQUENT CHANGES TO THE REPRODUCIBLE ORIGINAL <br />CONSTRUCTION DOCUMENTS (I.E. DOCUMENTS PROVIDED ELECTRONICALLY) WHICH ARE NOT MADE OR <br />OTHERWISE COMMUNICATED IN WRITING BY ENGINEER. <br />SHOP DRAWINGS / DEFERRED STRUCTURAL SUBMITTALS <br />NOTE: DEFERRED_ STRUCTURAL SUBMITTALS SHALL BE SUBMITTED TO THE_ BUILDING OFFICIAL WITH <br />E REVIEWED AND FOUND <br />DOCUMENTS HAVE BEEN NOTATION INDICATING THAT THE DEFERRED SUBMITTAL --__ <br />TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. DEFERRED SUBMITTAL ITEMS SHALL <br />APPROVED BY THE BUILDING <br />_ <br />NOT BE INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPR _ O- <br />OFFICIAL (FBC-B SEC 107.3.4.1 <br />1. THE CONTRACTOR SHALL SUBMIT A MINIMUM OF THREE COPIES OF THE FOLLOWING SHOP DRAWINGS <br />(MAXIMUM SCALE 1/8: = 1'-0") TO THE ARCHITECT/ENGINEER PRIOR TO THE FABRICATION OF ANY <br />STRUCTURAL COMPONENTS (ONE COPY TO BE RETAINED BY THE ARCHITECT AND ENGINEER). AS A <br />MINIMUM, ALL SHOP DRAWING SUBMITTALS SHOULD INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS OF <br />INSTALLATION AND CONNECTIONS, AND MATERIAL SPECIFICATIONS, UNLESS OTHERWISE NOTED. <br />2. SHOP DRAWINGS AND OTHER ITEMS SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW <br />PRIOR TO FABRICATION. BEFORE BEING SUBMITTED FOR REVIEW, ALL SHOP DRAWINGS SHALL BE <br />CHECKED BY THE FABRICATOR AND BEAR THE CHECKER'S INITIALS AND SHALL BE REVIEWED BY THE <br />CONTRACTOR FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS AND HAVE AN APPROVAL STAMP <br />PLACED ON EACH SHOP DRAWING INDICATING SUCH. ANY SHOP DRAWING NOT CHECKED OR REVIEWED BY <br />THE FABRICATOR AND CONTRACTOR PRIOR TO BEING SUBMITTED TO THE ARCHITECT/ENGINEER FOR <br />REVIEW MAY BE REJECTED AND RETURNED WITHOUT REVIEW. <br />3. IN NO CASE SHALL REPRODUCTION OF THE CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS. <br />4. DESIGN AND DETAILING SHALL BE PERFORMED USING RATIONAL ENGINEERING DESIGN PRACTICES AND BE <br />BASED ON STANDARD PRACTICES IN ACCORDANCE WITH CONSTRUCTION DOCUMENTS AND THE BUILDING <br />CODE AND ALL APPLICABLE BUILDING CODE AMENDMENTS. <br />5. THE ENGINEER'S REVIEW IS TO VERIFY CONFORMANCE WITH DESIGN CONCEPT AND GENERAL COMPLIANCE <br />WITH THE PERTINENT CONTRACT DOCUMENTS. THE ENGINEER'S REVIEW DOES NOT RELIEVE THE <br />CONTRACTOR OF THE RESPONSIBILITY TO REVIEW, CHECK, AND COORDINATE THE SHOP DRAWINGS PRIOR <br />TO SUBMISSION. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS <br />ASSOCIATED WITH THE SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSIONS, ETC. <br />6. AS A MINIMUM, SUBMIT THE FOLLOWING SHOP DRAWINGS FOR REVIEW: <br />a. REINFORCING STEEL IN REINFORCED CONCRETE AND MASONRY CONSTRUCTION - INCLUDE DETAILS OF <br />ALL BENT BARS, <br />VERTICAL REINFORCING AND HORIZONTAL BOND BEAM REINFORCING. INCLUDE PLANS AND <br />ELEVATIONS AS REQUIRED TO <br />CLEARLY SHOW ALL REINFORCING. <br />b. ALL CONCRETE CONSTRUCTION - SUBMIT A CONCRETE MIX DESIGN FOR EACH CONCRETE STRENGTH. <br />AS A MINIMUM, EACH <br />DESIGN SHALL INCLUDE PROPORTIONS OF CEMENT, FINE AND COURSE AGGREGATES, AND WATER, <br />STRUCTURAL NOTES <br />SCALE NTS <br />GRADATION OF COMBINED <br />AGGREGATES, AND CONCRETE COMPRESSIVE TEST RESULTS. CERTIFICATION SHALL BE FROM AN <br />ACCEPTABLE TESTING <br />LABORATORY. <br />c. PRECAST CONCRETE - SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED BY A <br />QUALIFIED PROFESSIONAL <br />ENGINEER. CALCULATIONS SHALL INCLUDE AS A MINIMUM, ALL LOADS, STRESSES, AND DEFLECTIONS <br />ASSOCIATED WITH EACH <br />MEMBER. <br />d. <br />e. STRUCTURAL STEEL - SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED <br />(CALCULATIONS ONLY) BY A <br />QUALIFIED PROFESSIONAL ENGINEER. CALCULATIONS SHALL INCLUDE AS A MINIMUM, ALL LOADS, <br />STRESSES,AND <br />DEFLECTIONS ASSOCIATED WITH EACH MEMBER AND/OR CONNECTION. <br />f. COLD -FORMED STEEL PURLINS AND GIRTS - SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND <br />SEALED BY A <br />QUALIFIED PROFESSIONAL ENGINEER. <br />SHOP DRAWINGS / DEFERRED STRUCTURAL SUBMITTALS (con't) <br />g. COLD -FORMED STEEL STUDS AND POSTS - SUBMIT ERECTION DRAWINGS. AS A MINIMUM ERECTION <br />DRAWINGS SHALL SHOW <br />LAYOUT, PIECE MARKS AND ASSOCIATED MEMBER SIZES INCLUDES STUDS/POSTS, TOP AND BOTTOM <br />TRACK/ANGLE, AND <br />COMPONENTS AND ACCESSORIES. <br />h. STEEL DECKING / PANELING - AS A MINIMUM, SUBMIT MANUFACTURER'S CATALOG WITH SHOP <br />DRAWINGS. <br />1. STEEL GRATING AND/OR FLOOR PLATE - INCLUDE ALL JOINT LOCATIONS, CONNECTION DETAILS, AND <br />GRADE OF STEEL. AS A <br />MINIMUM, SUBMIT MANUFACTURER'S CATALOG WITH SHOP DRAWINGS. <br />j. SHOP FABRICATED WOOD TRUSSES - SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND <br />SEALED BY A QUALIFIED <br />PROFESSIONAL ENGINEER. AS A MINIMUM, ALL SHOP DRAWINGS AND CALCULATIONS SHALL BE IN <br />CONFORMANCE WITH IBC <br />SECTION 2303.4. <br />7. AS A MINIMUM, SUBMIT THE FOLLOWING DEFERRED SUBMITTAL FOR REVIEW BY THE ENGINEER OR RECORD <br />AND REVIEW AND APPROVAL BY THE BUILDING OFFICIAL: <br />a. PRE-ENGINEERED METAL BUILDING- SUBMIT SHOP DRAWINGS AND CALCULATIONS AND A LETTER <br />SIGNED AND SEALED BY THE <br />PRE-ENGINEERED METAL BUILDING SYSTEMS ENGINEER OF RECORD STATING THAT THE <br />PRE-ENGINEERED METAL BUILDING IS <br />DESIGNED TO CONFORM TO THE DESIGN CRITERIA SET FORTH BY THE PROJECT ENGINEER OF RECORD. <br />THE SHOP DRAWING <br />SUBMITTAL SHALL INCLUDE ALL ANCHOR BOLT REQUIREMENTS AND FOUNDATION REACTIONS. <br />8. OTHER SUBMITTALS MAY BE REQUIRED PER THE SPECIFICATIONS OR THE SEPARATE NOTES CONTAINED <br />HEREIN. <br />9. TEMPORARY OR PERMANENT SYSTEMS OR FRAMING MEMBERS THAT ARE NOT SPECIFICALLY DESIGNED, <br />DETAILED, OR SPECIFIED IN THE CONTRACT DOCUMENTS BUT ARE REQUIRED TO COMPLETE THE FINISHED <br />STRUCTURE, SHALL BE DESIGNED AND DETAILED BY OR UNDER THE DIRECTION OF A QUALIFIED <br />PROFESSIONAL ENGINEER. ALL REQUESTED SUBMITTALS FOR THESE SYSTEMS OR FRAMING MEMBERS <br />SHALL BE SIGNED AND SEALED BY SAID QUALIFIED PROFESSIONAL ENGINEER. <br />10. ALL SIGNED AND SEALED SHOP DRAWINGS AND/OR CALCULATIONS THAT ARE REQUIRED TO BE SUBMITTED <br />FOR REVIEW SHALL BE DONE BY OR UNDER THE DIRECTION OF A QUALIFIED PROFESSIONAL ENGINEER. <br />11. A QUALIFIED PROFESSIONAL ENGINEER IS A PROFESSIONAL ENGINEER WHO IS LEGALLY REGISTERED AND <br />LICENSED TO PROVIDE ENGINEERING SERVICES IN THE JURISDICTION IN WHICH THE PROJECT IS LOCATED <br />AND WHO IS EXPERIENCED IN PROVIDING ENGINEERING SERVICES RELATED TO THE WORK SUBMITTED. <br />SAID ENGINEER SHALL BE CAPABLE OF PERFORMING DESIGN AND DETAILING USING RATIONAL <br />ENGINEERING DESIGN PRACTICES BASED ON STANDARD PRACTICES IN ACCORDANCE WITH THE CONTRACT <br />DOCUMENTS, THE BUILDING CODE, AND ALL APPLICABLE BUILDING CODE AMENDMENTS. <br />FOUNDATION DESIGN <br />1. THE FOUNDATION DESIGN IS BASED ON THE FINDINGS AND RECOMMENDATIONS MADE BY GEOTECHNICAL <br />ENGINEER OF RECORD. SUBGRADE PREPARATION SHALL CONFORM STRICTLY WITH THE <br />RECOMMENDATIONS GIVEN IN THIS REPORT AND AS PER THE GEOTECHNICAL ENGINEER'S FIELD <br />INSTRUCTIONS. <br />2. ASSUMED GEOTECHNICAL INFORMATION (IN THE ABSENCE OF REPORT): <br />a. ALLOWABLE SOIL PRESSURE 2,000 PSF <br />b. SOIL DENSITY 110 PCF <br />3. FOOTINGS SHALL BEAR AT LEAST 18" BELOW LOWEST ADJACENT FINISHED GRADE. FOOTING <br />SHOWN ON THE DRAWINGS ARE MINIMUM AND FOR GUIDANCE ONLY; THE ACTUAL <br />DEPTHS/ELEVATIONS S O , <br />ELEVATIONS OF FOOTINGS MUST BE ESTABLISHED BY THE CONTRACTOR IN THE FIELD. <br />4. ALL FOOTINGS SHALL BEAR ON UNDISTURBED, FIRM NATURAL SOIL OR COMPACTED FILL CAPABLE OF <br />SUPPORTING THE DESIGN BEARING PRESSURE NOTED HEREIN. <br />5. ALL SOIL SURROUNDING AND BENEATH ALL FOOTINGS, SLABS, ETC. SHALL BE PROTECTED AGAINST FROST <br />OR FREEZING DURING CONSTRUCTION. <br />6. THE CONTRACTOR SHOULD EMPLOY A PROFESSIONAL GEOTECHNICAL ENGINEER TO INSPECT THE <br />FOUNDATIONS AND BEARING LEVELS AND VERIFY THAT THE MATERIAL ON WHICH THE FOUNDATIONS WILL <br />BEAR HAS AT LEAST THE ABOVE NOTED CAPACITY AND GIVE RECOMMENDATIONS FOR SUBGRADE <br />PREPARATION. STRICTLY FOLLOW GEOTECHNICAL ENGINEER'S RECOMMENDATIONS FOR SUBBASE AND <br />FOOTING BEARING MATERIAL AND PREPARATION AS REQUIRED. <br />7. IMMEDIATELY NOTIFY THE ENGINEER AND/OR ARCHITECT IF UNSUITABLE SOIL OR SOIL CONDITIONS AT <br />VARIANCE WITH THE GEOTECHNICAL REPORT IS DISCOVERED AT THE FOOTING ELEVATIONS SPECIFIED. <br />8. NO BACKFILL SHALL BE PLACED AGAINST WALLS UNTIL WALLS AND SLABS (OR HORIZONTAL BEAMS AND <br />STRUTS) SUPPORTED E DESIGN STRENGTH OR PRIOR TO THE COMPLETE <br />THEREON N O HAVE ATTAINED <br />INSTALLATION OF THE LATERAL LOAD RESISTING SYSTEM. <br />9. BACKFILL BEHIND ALL RETAINING AND/OR BASEMENT WALLS WITH FREE DRAINING GRANULAR FILL AND <br />PROVIDE SUBSURFACE DRAINAGE AS REQUIRED. ALL BACKFILL MATERIAL SHALL CONFORM STRICTLY WITH <br />THE RECOMMENDATIONS GIVEN IN THE GEOTECHNICAL REPORT MENTIONED ABOVE OR PER A <br />PROFESSIONAL GEOTECHNICAL ENGINEER'S FIELD INSTRUCTIONS. <br />10. PROVIDE VERTICAL CONTROL JOINTS IN RETAINING WALLS AS INDICATED. PROVIDE ADDITIONAL JOINTS AS <br />REQUIRED SO THE SPACING BETWEEN JOINTS DOES NOT EXCEED A SPACING OF 3.0 X WALL HEIGHT (25 <br />FEET MAXIMUM). PROVIDE EXPANSION JOINTS AT EVERY FOURTH CONTROL JOINT, UNLESS OTHERWISE <br />NOTED. <br />11. THE EXISTENCE OF UNDERGROUND STRUCTURES AND/OR UTILITIES IS NOT KNOWN. IT IS THE <br />CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER OR NECESSARY AUTHORITIES THE <br />LOCATIONS OF ALL EXISTING UNDERGROUND STRUCTURES AND/OR UTILITIES. <br />12. WHERE FOOTINGS ARE IN CLOSE PROXIMITY OF SEWERS, DRAINS, CONDUITS, PIPES, ETC., THE BOTTOM OF <br />FOOTING SHALL BE SET AT OR BELOW THE INVERT ELEVATION OF THE ADJACENT ELEMENT. <br />CAST -IN -PLACE CONCRETE <br />1. ALL REINFORCED CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND <br />APPLICABLE AMENDMENTS AND THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI <br />318) OF THE AMERICAN CONCRETE INSTITUTE. <br />2. ALL REINFORCED CONCRETE MIX DESIGNS SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING <br />CODE AND APPLICABLE AMENDMENTS AND THE "SPECIFICATIONS FOR STRUCTURAL CONCRETE" (ACI 301) <br />OF THE AMERICAN CONCRETE INSTITUTE. <br />3. ALL REINFORCING STEEL FABRICATION AND PLACEMENT SHALL BE PERFORMED IN ACCORDANCE WITH THE <br />BUILDING CODE AND APPLICABLE AMENDMENTS AND THE "MANUAL OF STANDARD PRACTICE" (CRSI MSP-1) <br />OF THE CONCRETE REINFORCING STEEL INSTITUTE AND THE "SPECIFICATIONS FOR STRUCTURAL <br />CONCRETE FOR BUILDINGS" (ACI 301) AND "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" (ACI <br />315) OF THE AMERICAN CONCRETE INSTITUTE, <br />4. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (144 PCF+) CONFORMING TO ASTM C94 WITH ALL <br />CEMENT CONFORMING TO ASTM C150, TYPE I OR II. MAXIMUM AGGREGATE SIZE SHALL BE 1-1/2" FOR <br />FOOTINGS AND 3/4" FOR WALLS AND SLABS, CONFORMING TO ASTM C33. <br />5. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'C) AT 28 DAYS, SLUMP AND MAXIMUM <br />WATER/CEMENT RATIO REQUIREMENTS: <br />a. STRUCTURAL CONCRETE: 3000 PSI 2" - 4" SLUMP* W/C RATIO = .58 <br />b. CONCRETE FILL: 2500 PSI 2" - 4" SLUMP W/C RATIO = .58 <br />6. OBTAIN EACH TYPE OF CEMENT OF THE SAME BRAND FROM THE SAME MANUFACTURER'S PLANT, EACH <br />AGGREGATE FROM ONE SOURCE, AND EACH ADMIXTURE FROM THE SAME MANUFACTURER. <br />7. ALL CONCRETE EXPOSED TO WEATHER SHALL HAVE ENTRAINED AIR IN ACCORDANCE WITH SECTION 1904 <br />OF THE IBC. <br />8. FOR AIR ENTRAINED CONCRETE - MAXIMUM W/C RATIO = .44 <br />9. ALL ADMIXTURES SHALL CONFORM TO ASTM C260, C494, C618, C989 AND C1017 (LISTING IS NOT ALL <br />INCLUSIVE). <br />10. ALL GROUT SHALL BE NONMETALLIC SHRINKAGE -RESISTANT GROUT PROVIDED BY A MANUFACTURER <br />APPROVED IN WRITING BY THE STRUCTURAL ENGINEER AND INSTALLED AND MIXED PER THE <br />MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS. ALL GROUT SHALL HAVE A MINIMUM <br />COMPRESSIVE STRENGTH (F'C) AT 28 DAYS EQUAL TO 5000 PSI. <br />11. REINFORCEMENT: <br />a. DEFORMED BARS ASTM A615, GRADE 60 <br />b. WELDED WIRE REINFORCEMENT ASTM A185 <br />c. GALVANIZED REINFORCEMENT ASTM A767, CLASS II <br />12. REINFORCING STEEL SHALL HAVE THE FOLLOWING MINIMUM CLEAR CONCRETE COVER UNLESS OTHERWISE <br />NOTED: <br />a. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" <br />b. CONCRETE SURFACES IN CONTACT WITH SOIL OR EXPOSED TO <br />c. EARTH OR WEATHER (#6 BARS OR LARGER) 2" <br />(#5 BARS OR SMALLER) 1-1/2" <br />d. COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1-1/2" <br />e. CONCRETE SURFACES NOT IN CONTACT WITH SOIL OR <br />EXPOSED TO WEATHER INCLUDING WALLS AND TOP AND <br />BOTTOM OF SLABS 1" <br />CAST -IN -PLACE CONCRETE (con't) <br />13. WELDING OF REINFORCING BARS IS PROHIBITED WITHOUT PRIOR WRITTEN APPROVAL FROM THE <br />ENGINEER. IF WELDING OF REINFORCING IS NECESSARY, IT SHALL BE PERFORMED IN ACCORDANCE WITH <br />AWS D1.4. REINFORCING STEEL FOR WELDED ASSEMBLIES SHALL CONFORM TO ASTM A706 <br />SPECIFICATIONS. <br />14. SPLICED BARS SHALL HAVE A MINIMUM LAP OF CLASS B TENSION LAP SPLICE PER TYPICAL DETAILS UNLESS <br />OTHERWISE NOTED. STAGGER SPLICE WHERE POSSIBLE. <br />15. GALVANIZED REINFORCING SHALL BE TREATED TO PREVENT REDUCTION OF BOND. OTHERWISE PROVIDE <br />SPLICE LENGTHES EQUIVILANT TO EPDXY COATED REINFORCING. <br />16. ALL REINFORCING STEEL INDICATED AS BEING CONTINUOUS (CONT.) ON THE PLANS AND DETAILS SHALL BE <br />LAPPED WITH A CLASS B SPLICE OR 36 X BAR DIAMETER (WHICHEVER IS GREATER) UNLESS OTHERWISE <br />NOTED. <br />17. REINFORCING BARS TO EXTEND 12 BAR DIAMETERS BUT NOT LESS THAN 12" BEYOND BAR BENDS, UNLESS <br />OTHERWISE NOTED. <br />18. PROVIDE ADDITIONAL BARS IN FOOTINGS, GRADE BEAMS, WALLS AND SLABS AS SHOWN IN TYPICAL <br />DETAILS. <br />19. ALL REINFORCING STEEL SHALL BE SET AND TIED IN PLACE PRIOR TO POURING OF CONCRETE. NO BARS <br />PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED <br />OR APPROVED BY THE ENGINEER IN WRITING. <br />20. PROVIDE CORROSION RESISTANT ACCESSORIES SUCH AS PLASTIC COATED (NOT PLASTIC TIPPED) OR <br />STAINLESS STEEL CHAIRS IN ALL EXPOSED CONCRETE CONSTRUCTION. PRECAST CONCRETE CHAIRS OR <br />SAND PLATE CHAIRS SHALL BE USED FOR THE SUPPORT OF REINFORCING ON GRADE. CONCRETE BLOCK <br />OR CLAY MASONRY BRICK ARE NOT PERMITTED. <br />21. ALL WWR SHALL BE CHAIRED TO ITS PROPER HEIGHT AND MAINTAINED AT THE PROPER LEVEL <br />THROUGHOUT THE CONCRETE PLACING OPERATION. LIFTING OF WWR WITH A HOOK DURING CONCRETE <br />PLACEMENT SHALL NOT BE PERMITTED. <br />22. CONSTRUCTION JOINTS SHALL NOT BE PLACED AT LOCATIONS OTHER THAN THOSE SHOWN ON THE <br />DRAWINGS WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ENGINEER AND ARCHITECT. <br />23. SEALANT AND WATERSTOPS SHALL BE PROVIDED IN JOINTS WHERE SHOWN ON THE DRAWINGS OR IN <br />ACCORDANCE WITH THE IBC. <br />24. ALL EXPOSED CORNERS OF CONCRETE TO HAVE 3/4" MINIMUM CHAMFER UNLESS OTHERWISE NOTED. <br />25. CONCRETE SHALL BE DISCHARGED AT THE SITE WITHIN 1-1/2 HOURS AFTER WATER HAS BEEN ADDED TO <br />THE CEMENT AND AGGREGATE. ADDITION OF WATER TO THE MIX AT THE PROJECT SITE IS STRICTLY <br />PROHIBITED. ALL WATER MUST BE ADDED AT THE BATCH PLANT ONLY. <br />26. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CONCRETE OPENINGS AND/OR <br />PENETRATIONS REQUIRED FOR OTHER TRADES PRIOR TO PLACING CONCRETE. <br />27. CONDUITS OR PIPES EMBEDDED IN SLABS SHALL NOT HAVE AN OUTSIDE DIMENSION LARGER THAN 1/3 THE <br />SLAB THICKNESS AND SHALL BE SPACED NO CLOSER THAN 3 DIAMETERS ON CENTER. ALUMINUM CONDUITS <br />SHALL NOT BE EMBEDDED IN CONCRETE. <br />28. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR REGLETS, PIPE SLEEVES, <br />CONDUITS OR OTHER ITEMS TO BE EMBEDDED OR PASSED THROUGH CONCRETE. <br />29. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOORS AND FOR ALL FLOOR <br />SLOPES. <br />TUILT-UP CONCRETE <br />1. ALL DESIGN, FABRICATION, TRANSPORTATION, AND ERECTION SHALL BE PERFORMED IN ACCORDANCE <br />WITH THE ALL APPLICABLE REQUIREMENTS OF THE AMERICAN CONCRETE INSTITUTE AND THE PRECAST <br />PRESTRESSED CONCRETE INSTITUTE. <br />2. ALL PRECAST CONCRETE TILT -UP WALL PANELS SHALL BE 5-1/2" THICK UNLESS NOTED OTHERWISE. IF <br />THICKNESS VARIES THE CONTRACTOR SHALL NOTIFY THE ENGINEER/ARCHITECT IN WRITING TO OBTAIN <br />ENGINEER/ARCHITECT'S APPROVAL PRIOR TO FABRICATION. <br />3. PRECAST CONCRETE ELEMENTS SHALL BE DESIGNED TO SUPPORT THE MINIMUM LOADS INDICATED BELOW <br />(PLUS SELF WEIGHT) AT THE SPAN AND SPACING INDICATED ON THE DRAWINGS: <br />a. SUPERIMPOSED UNIFORM DEAD LOAD 7 PSF (ROOF) <br />b. SUPERIMPOSED UNIFORM LIVE LOADS SEE DESIGN LOADS <br />c. SUPERIMPOSED UNIFORM SNOW LOAD SEE DESIGN LOADS <br />d. LATERAL LOADS SEE DESIGN LOADS <br />4. PLATES AND ANCHORS SHALL BE DESIGNED BY THE PRECAST CONCRETE MANUFACTURER/SUPPLIER TO <br />DEVELOP THE ENTIRE CONNECTION. <br />5. THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR REVIEW THE METHOD OF LIFTING PANELS PRIOR <br />TO FABRICATION OF PANELS AND SHALL FURNISH AND INSTALL ALL LIFTING INSERTS AND ANY ADDITIONAL <br />REINFORCING REQUIRED BY THE LIFTING METHOD. <br />6. OPENINGS IN PANELS FOR CONNECTION PURPOSES AND ANY DEVIATION IN THE PANELS FROM WHAT IS <br />SHOWN IN THE CONSTRUCTION DOCUMENTS SHALL BE SUBMITTED TO THE ENGINEER/ARCHITECT IN <br />WRITING TO OBTAIN ENGINEER/ARCHITECT'S APPROVAL PRIOR TO FABRICATION. <br />CONCRETE UNIT MASONRY <br />1. ALL MASONRY WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND APPLICABLE <br />AMENDMENTS AND THE "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530/ASCE 5) AS <br />WELL AS THE "SPECIFICATIONS FOR MASONRY STRUCTURES" (ACI 530.1/ASCE 6) OF THE AMERICAN <br />CONCRETE INSTITUTE AND THE AMERICAN SOCIETY OF CIVIL ENGINEERS. <br />2. ALL MORTAR SHALL BE ASTM C270, TYPE M (BELOW GRADE) OR TYPE S (ABOVE GRADE AND BE MADE WITH <br />PORTLAND CEMENT / LIME (NON AIR ENTRAINED). THE MORTAR SHALL OBTAIN A MINIMUM COMPRESSIVE <br />STRENGTH OF 1,800 PSI AT 28 DAYS. THE USE OF PREMIXED MASONRY CEMENT MORTAR IS STRICTLY <br />PROHIBITED. <br />3. ALL MASONRY GROUT SHALL BE ASTM C476, WITH A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI WITHIN <br />AT 28 DAYS CONCRETE SHALL NOT BE USED IN LIEU OF MASONRY GROUT. <br />4. CONCRETE MASONRY UNITS (NORMAL WEIGHT UNITS WITH A DRY UNIT WEIGHT OF NOT MORE THAN 135 <br />PCF) <br />a. HOLLOW UNITS ASTM C90, TYPE N-1 <br />b. SOLID UNITS ASTM C145, TYPE N-1 <br />5. THE MINIMUM COMPRESSIVE STRENGTH OF MASONRY (F-M) SHALL NOT BE LESS THAN 1,500 PSI AS <br />DETERMINED BY THE UNIT STRENGTH METHOD OF ACI 530. <br />6. REINFORCEMENT: <br />a. DEFORMED BARS ASTM A615, GRADE 60 <br />b. JOINT REINFORCEMENT ASTM A951 <br />c. GALVANIZED REINFORCEMENT ASTM A767, CLASS II <br />7. GALVANIZED REINFORCING SHALL BE TREATED TO PREVENT REDUCTION OF BOND. OTHERWISE PROVIDE <br />SPLICE LENGTHES EQUIVILANT TO EPDXY COATED REINFORCING. <br />8. UNLESS OTHERWISE NOTED, CENTER ALL VERTICAL REINFORCING IN CMU CORE AND HOLD IN POSITION <br />WITH CAGING DEVICES. <br />9. UNLESS OTHERWISE NOTED, ALL WALLS SHALL BE LAID IN RUNNING BOND. BOND CORNERS AND <br />INTERSECTIONS OF ALL WALLS. ALL UNITS SHALL BE LAID WITH FULL MORTAR COVERAGE ON HEAD, BED <br />(FACE SHELL), WEBS, AND COLLAR JOINTS, UNLESS OTHERWISE NOTED. <br />10. ALL INTERSECTING WALLS SHALL BE TIED TOGETHER IN MASONRY BOND BEAMS, UNLESS OTHERWISE <br />NOTED. <br />11. HORIZONTAL TRUSS -TYPE JOINT REINFORCEMENT SHALL BE PLACED IN ALL WALLS SPACED AT 16 INCHES <br />ON CENTER. COORDINATE BRICK TIE BACK REQUIREMENTS WITH THE ARCHITECTURAL DRAWINGS. UNLESS <br />OTHERWISE NOTED, STOP ALL HORIZONTAL JOINT REINFORCEMENT AT CONTROL JOINTS. <br />12. PROVIDE SOLIDLY GROUTED HORIZONTAL BOND BEAMS WITH CONTINUOUS REINFORCING AS INDICATED. <br />DISCONTINUE ALL HORIZONTAL REINFORCING AT CONTROL JOINTS EXCEPT FOR THE BOND BEAMS AT <br />BEARING ELEVATIONS. <br />13. PROVIDE VERTICAL CONTROL JOINTS AS INDICATED. PROVIDE ADDITIONAL JOINTS AS REQUIRED SO THE <br />SPACING BETWEEN JOINTS DOES NOT EXCEED A SPACING OF 1.5 X WALL HEIGHT (25 FEET MAXIMUM). <br />WHERE BEAMS OR LINTELS BEAR AT CMU CONTROL JOINTS, OFFSET & LAP THE VERTICAL REINFORCING. <br />14. PROVIDE AN ADDITIONAL VERTICAL REINFORCING BAR (SAME SIZE AS ADJACENT WALL) FULL HEIGHT OF <br />WALL AT ALL CORNERS, INTERSECTIONS, WALL ENDS, BEAM BEARINGS, OPENING EDGES, AND EACH SIDE <br />OF CONTROL JOINTS UNLESS OTHERWISE NOTED. <br />15. VERTICAL REINFORCING SHALL EXTEND TO 2" BELOW THE TOP OF THE CMU WALL OR PARAPET. <br />16. UNLESS OTHERWISE NOTED, GROUT CMU SOLID A MINIMUM OF THREE COURSES BELOW ALL BEAM BEARING <br />PLATES, BEAMS, LINTELS, POSTS, AND SIMILAR CONDITIONS OVER A WIDTH OF 7-8" CENTERED ON THE <br />BEARING LOCATION. <br />17. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE OVERALL THICKNESS OF THE WALL, WALL <br />CONSTRUCTION REQUIREMENTS, AND THE LOCATIONS OF ALL DOOR AND WINDOW OPENINGS AND MEP <br />PENETRATIONS. <br />18. NO CHASES, RISERS, CONDUITS, OR TOOTHING OF MASONRY SHALL OCCUR WITHIN 17" OF CENTERLINE OF <br />BEAM BEARING OR LOAD CONCENTRATION. <br />19. HIGH LIFT GROUTING: GROUT LIFT HEIGHTS UNDER THE FOLLOWING CONDITIONS PERMIT GROUT TO BE <br />PLACED IN LIFTS NOT EXCEEDING 12.67 FEET. CONDITIONS THAT MUST BE MET ARE: <br />THE MASONRY HAS CURED FOR AT LEAST FOUR HOURS * THE GROUT HAS A SLUMP OF 10 TO 11 INCHES <br />THERE ARE NO INTERMEDIATE HORIZONTAL REINFORCED BOND BEAMS BETWEEN THE TOP AND BOTTOM OF <br />THE POUR HEIGHT IF THESE CONDITIONS ARE MET BUT INTERMEDIATE BOND BEAMS ARE PRESENT WITHIN <br />THE POUR, THEN THE LIFT IS LIMITED TO THE BOTTOM OF THE BOND BEAM, BUT CANNOT EXCEED 12.67 <br />FEET. REGARDLESS OF OTHER CONDITIONS, IF THE MASONRY HAS NOT CURED FOR AT LEAST FOUR HOURS <br />BEFORE GROUTING OR IF THE GROUT HAS A SLUMP LESS THAN 10 INCHES, GROUT LIFTS CANNOT EXCEED <br />FIVE FEET. PROVIDE INSPECTION PORTS AT BASE OF WALL AT EACH REINFORCED CELL WHERE HEIGHT OF <br />POUR EXCEEDS 5FT. <br />CONCRETE/MASONRY ANCHORS <br />1. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE KWIK BOLT TZ (ICC <br />ESR-1917) AS MANUFACTURED BY THE HILTI CORP. OR AN APPROVED EQUIVALENT IN STRENGTH AND <br />EMBEDMENT. <br />2. ADHESIVE ANCHORS SHALL BE HIT -RE 500-SD (ICC ESR-2322) INTO CONCRETE, HIT HY 150 MAX (ESR-1967) <br />INTO MASONRY (CMU), AND HIT HY 70 MAX (ESR-1967) INTO MASONRY (MULTI-WYTHE BRICK) AS <br />MANUFACTURED BY THE HILTI CORP. OR AN APPROVED EQUIVALENT IN STRENGTH AND EMBEDMENT. <br />3. DRIVE PINS AND OTHER GAS DRIVEN FASTENERS SHALL BE 0.145" DIAMETER WITH STEP SHANK TRAK-IT C5 <br />AS MANUFACTURED BY THE POWERS FASTENERS, INC. OR AN APPROVED EQUIVALENT IN STRENGTH AND <br />EMBEDMENT. INSTALL IN STRICT ACCORDANCE WITH ICC-ES REPORT ESR-3275. MINIMUM EMBEDMENT IN <br />CONCRETE SHALL BE 3/4" UNLESS OTHERWISE NOTED. MAINTAIN AT LEAST 3" TO NEAREST CONCRETE <br />EDGE. <br />4. ALL ANCHORS SHALL BE INSTALLED WITH STEEL WASHERS. <br />5. WHEN USING ADHESIVE ANCHORING SYSTEMS THE MANUFACTURER SHALL SUPPLY THE ANCHOR AND <br />ADHESIVE, UNLESS OTHERWISE NOTED. <br />6. ALL ALTERNATE PRODUCTS SHALL HAVE A CURRENT ICC EVALUATION REPORT. <br />7. ANCHORS INSTALLED INTO MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS UNLESS OTHERWISE <br />NOTED. IF GROUTED CELLS ARE NOT ENCOUNTERED, BREAK INTO CELL AND GROUT SOLID 8". <br />8. ALL ANCHORS SHALL BE APPROVED FOR USE WITH CRACKED CONCRETE AND CONFORM TO CURRENT ICC <br />ES REPORT ICC-ES AC193 FOR MECHANICAL ANCHORS AND ICC-ES AC308 FOR ADHESIVE ANCHORS). <br />9. INSTALL ALL ANCHORS IN STRICT ACCORDANCE WITH ALL APPLICABLE ICC-ES AND BUILDING CODE <br />REQUIREMENTS. ALL ANCHOR SPACING, EMBEDMENT, EDGE DISTANCE, AND INSTALLATION SHALL BE IN <br />ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. REFER TO SECTIONS AND DETAILS ON THE <br />DRAWINGS FOR ADDITIONAL INFORMATION. <br />10. ALL PERSONNEL INSTALLING MECHANICAUADHESIVE ANCHORS SHALL BE TRAINED BY THE PRODUCT <br />MANUFACTURER ON PROPER INSTALLATION TECHNIQUES. TRAINING DOCUMENTATION FROM THE <br />MANUFACTURER REQUEST. <br />SHALL BE AVAILABLE UPON RE L Q <br />PROVIDE CONCRETE HAVING FOLLOWING GENERAL CHARACTERISTICS <br />DESCRIPTION AS PER MAX. AGG. SIZE MAX. W/C AVERAGE <br />ASTM A39 INCH RATIO ENTRAINED AIR <br />FOOTING, 4000(UNO ON PLANS) 1 0.50 6.5% <br />SLAB ON GRADE <br />FRAMED FLOORS 4000 1/2 0.500 6.5% - 1 <br />W 4000 6.5% <br />WALLS 1 0.50 <br />AVERAGE AIR ENTRAINMENT VALUES ARE FOR IN PLACE CONCRETE. TOLERANCE ON TOTAL AIR <br />CONTENT IS 1.5 % PER ACI. <br />SPECIFIED HEREIN. SPECIFIC DRAWINGS OR DETAILS MAY OR MAY NOT INDICATE EPDXY COATING OR <br />UNCOATED REINFORCING. IN AREAS OF DISPUTE THIS SCHEDULE SHALL GOVERN IN ALL CASES. <br />DESCRIPTION COVER PROTECTION <br />WALLS NOT IN 1 112" UNCOATED <br />CONTACT WI EARTH <br />WALLS IN 2^ UNCOATED <br />CONTACT W/EARTH <br />FOOTING I WALLS CAST 3" UNCOATED <br />AGAINST EARTH <br />FRAMED FLOORS 314" NU C AO TED <br />SLAB ON -GRADE MID -DEPTH, I UNCOATED <br />LINO <br />I <br />LIGHTNING STEEL CG19-014 <br />Fc F CONNELLY 13ROUP <br />C O N S U LTING ENGIN E E R S <br />T 200 2nd Ave South - #465 . St Petersburg, FL 33701 <br />Q infoCconnellyengineering.com <br />(T)813.232.8448 (F)800.698. 1945 <br />0 <br />www.connellyengineering.com <br />PROJECT <br />m,A PERMT NiENr . <br />0 A en Pn MM owl BE CONSTRUCTED BE A ucvlSE TO PROCEED WITH THWORKc WORK DATA <br />CU AND ROT AS AUTHORITY TO VNOIATE, CANCEL ALTER OR ET AM AM OF THE PROVIdORB'- <br />♦ OF THE TMWLL CODES. NON NULL ISSUANCE OF A POW PREYERT THE WILDS DESIGNER <br />♦� OFFCIAL FROM THEREAFTER RESUMD A CORRECTION OF ERRORS INFILM <br />CON STRUCTON OR VIOLATIONS OF OF TCOE. EVERY POW ISSUED SHALL BECOME <br />♦ INVALID IRaEee THE WORK AUTHOR® BY SUCH PEMAIT E COAREMCm NnEN SIX -.- -- <br />QI NOWTE AFTER ITS NIN AKL OR F THE WORK AUTHORIZED By WCH POW N DRAWN BY <br />SUSPENDED OR AMNodED FOR A PERIOD OF BOt FDNTIN AFTER THETOE THEWORK E <br />u I owex�D. JJC <br />WE HEREBY CERTIFY THAT TEE PLANE AND SPECIFICATIONS CMKY WITH THE <br />Q ESINIENIMITB OF THE APPLICABLE SULONS CODES SPECIFIED ON THE TITLE SHEET CHECKED <br />p CRC <br />J <br />CL / <br />LU <br />LL! <br />0 <br />s' <br />in FBC <br />ml <br />6TH EDITION <br />cu <br />fm <br />(2017) <br />I <br />o t <br />a CONNELLY GROUP CONSULTING ENGINEERS AND THEIR <br />o AGENTS, RESERVES THE RIGHT TO REVISE DETAILS <br />w ! SHOWN HERE AT SUCH TIME AS REVISIONS WILL RESULT <br />a IN ENGINEERING OR ECONOMIC IMPROVEMENTS. THESE <br />N DRAWINGS ARE GRAPHIC REPRESENTATION OF A DESIGN <br />I-- CONCEPT. ACTUAL DETAILS SUBJECT TO FIELD <br />UJILU VERIFICATION. <br />x <br />to <br />i <br />W <br />� <br />I <br />W <br />cu <br />C3 <br />Ln <br />cn <br />c <br />w <br />z' <br />O <br />coI <br />>- <br />J <br />L <br />W <br />ci <br />c <br />O <br />z <br />Q <br />tf7 <br />zmom <br />O <br />F- <br />v <br />J ! <br />V <br />O <br />C7 <br />U_ <br />L <br />CU <br />T <br />PERSONS <br />O <br />W <br />EREVIEW <br />DRAWING SETS <br />'. <br />�I <br />11.14.18 (01! • 18.04.IB (OBl <br />. _ <br />- - <br />BID <br />00.00.00 <br />PERMIT (00 REVIEW) <br />08.06.19 <br />PROFESSIONAL SEAL <br />DATE SEALED: SEPTEMBER 6, 2018 <br />o � <br />Nz r <br />0 <br />o°�OAQj�zko) I a1` GH Q <br />CHRISTOPHER R. CONNELLY, PE <br />PE-FL63888 i CA•FL 26841 <br />STRUCTURAL NOTES <br />