<br />BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States
<br />BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
<br />See General Information for Fire -resistance Ratings - ANSI/UL 263 Certified for United States
<br />2gEign Criteria and Allowable Variances
<br />See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
<br />esign Criteria and Allowable Variances
<br />Design No. U659
<br />November 06, 2015
<br />Nonbearing Wall Rating - 2 Hr
<br />* Indicates such products shall bear the UL or CUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
<br />1
<br />4
<br />1 1
<br />VERTICAL SECTION
<br />1
<br />P
<br />1 3 1
<br />HORIZONTAL SECTION
<br />1. Flashing Channels — Channels 8 in.wide with 3 in. flanges fabricated from nominal 16 MSG thick galvanized or aluminum -zinc alloy -coated sheet steel.
<br />Fastened to the support with 1/4 in. by 1-3/4 in. anchors spaced 12 in. OC.
<br />2. Steel Liner — Panels available in nominal 2 ft.-7-1/2 in, widths fabricated from nominal 22 MSG thick galvanized or aluminum -zinc alloy -coated sheet
<br />steel. Fastened to flashing channels with 3/4 In, long sheet metal screws spaced 12 In. OC. Interlocking joints of adjacent panels sealed with factory -
<br />applied butyl caulking and secured with 3/4 in. long sheet metal screws spaced 12 in. OC. Optionally, butyl tape applied between the steel liner panels and
<br />the flashing channels to provide an air barrier.
<br />or
<br />2.(b) Wall and Partition Facings — Corrugated or flat panel, available in various profiles and widths, fabricated from 22 MSG thick galvanized or
<br />aluminum -zinc alloy coated sheet steel. Fastened to the Z-bar sub-girts with 3/4 in. long sheet metal screws spaced 12 in. OC. Fastened to flashing
<br />channels with 3/4 in. long sheet metal screws spaced 16 in. OC. Side lap joints of adjacent panels fastened with 3/4 in. long sheet metal screws spaced 16
<br />In. OC. The top and bottom of exterior cladding are trimmed with cap and drip flashings respectively. Optionally, butyl tape applied between the panels and
<br />the flashing channels to provide an air barrier.
<br />3. Z-Bar Sub-Glrts — Notched Z-bars 8 in. wide with 1-3/4 in. flanges fabricated from nominal 18 MSG thick galvanized or aluminum -zinc alloy -coated
<br />sheet steel. Spaced a maximum of 5 ft. OC. Fastened to the steel liner panels (item 2a) or wall and partition panels (items 2b or 2c) with 1-1/4 in. long
<br />sheet metal screws spaced not more than 8 in. OC.
<br />4. Ceramic Fibre Blanket — 8 pcf density, 1/2 in. thick, installed to envelop the top surface and both flanged edges of the z-bar sub-girts. Blanket fixed
<br />to sub-girts with stick pins spaced 10 in. OC.
<br />5. Batts and Blankets — (BZJZ). Two layers of mineral wool batts, 24 or 32 in. wide by minimum 4 ft. long by 4 in. thick, designated "Roxulp Firewall
<br />2HR". Mineral Fibre Insulation, minimum density 4.5 pcf, installed with joints staggered a minimum of 12 in. within each layer and between adjacent layers.
<br />The overall thickness of the wall may be increased provided the Mineral Fibre Insulation (Item 5) is used to completely fill the wall cavity, and provided the
<br />size of the Flashing Channels (Item 1) and Z-Bar Sub-Girts (Item 3) are increased to match the thicker wall.
<br />ROCKWOOL — Types "Roxul Safe 55"
<br />* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
<br />respectively.
<br />Last U d0 ated on 2015-11-06
<br />Questions? Print h p_agg Terms of Use Page To12
<br />© 2018 UL LLC
<br />The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only
<br />those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product.
<br />UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions,
<br />Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The
<br />statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must
<br />include a copyright notice in the following format: "C) 2018 UL LLC".
<br />1 UL RATED WALL - 2 HOUR PANEL WALL - U659 (SEE PLAN FOR LOCATION)
<br />SCALE NTS
<br />PRODUCTS S QUANTITIES STORED:
<br />1. NO HAZARDOUS MATERIAL STORED ON SITE
<br />2. STRUCTURAL STEEL PIECES AND PARTS
<br />2 STORED MATERIALS LIST
<br />SCALE: NTS
<br />System No. W-L-1030
<br />XHEZ.W-L-1030
<br />Through -penetration Firestop Systems
<br />Page Bottom
<br />Design/System/Construction/Assembly Usage Disclaimer
<br />0 Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed
<br />or Classified products, equipment, system, devices, and materials.
<br />0 Authorities Having Jurisdiction should be consulted before construction.
<br />0 Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with
<br />applicable requirements. The published information cannot always address every construction nuance encountered in the field.
<br />0 When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product
<br />manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each
<br />product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate
<br />methods of construction.
<br />0 Only products which bear UL's Mark are considered as Classified, Listed, or Recognized.
<br />Through -penetration Firestop Systems
<br />See General Information for Through -penetration Firestop Systems
<br />System No. W-L-1030
<br />June 25, 2011
<br />F Ratings — 1 and 2 Hr (See Item 1)
<br />T Rating — 0 Hr
<br />r}••A
<br />2` I -
<br />r .f
<br />Z:, _ M
<br />J 1:`3A)
<br />SECMN A•SRA
<br />1. Wall Assembly — The 1 or 2 hr fire -rated gypsum wallboard/stud assembly shall be constructed of the materials and in
<br />the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and
<br />shall include the following construction features:
<br />A. Studs — Wall flaming may consist of either wood studs or steel channel studs. Wood studs to
<br />consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced
<br />max 24 in. OC.
<br />B. Gypsum Board* — 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard
<br />type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the
<br />individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max dery of opening is 5
<br />in.
<br />2. Through Penetrants — One metallic pipe, conduit or tubing to be centered within the firestop system. A nom annular
<br />space of 1/4 in. is required within the firestop system. Pipe, conduit or tubing to be rigidly supported on both sides of wall
<br />assembly. The following types and sizes of metallic pipes, conduits or tubing may be used:
<br />A. Steel Pipe — Nom 4 in. diam (or smaller) Schedule 5 (or heavier) steel pipe.
<br />B. Conduit — Nom 4 in. diam (or smaller) steel electrical metallic tubing or rigid steel conduit.
<br />3. Firestop System — The firestop system shal consist of the following:
<br />A. Packing Material — (Optional) — Nom 1/2 in. diam poyurethane backer rod friction fitted into
<br />the opening. Packing material to be recessed from both surfaces of wall as required to
<br />accommodate the required thickness of fit material.
<br />B. F81, Vold or Cavity Material* — Caulk — For 2 hr fire -rated assemblies, min 5/8 In. thickness
<br />of fill material applied within annulus on both surfaces of wall. Additional flit material to be installed
<br />such that a min 3/8 in, crown is formed around the penetrating Rem.
<br />For 1 hr fire -rated assemblies, min 5/8 in. thickness of fill material applied on both surfaces of wall.
<br />Additional fill material to be installed such that a min 3/8 in. crown is formed around the penetrating
<br />item and lapping 1 in. beyond the periphery of the opening.
<br />EGS NELSON FIRESTOP — Type CLK N/S (Non -Sag) Caulk.
<br />*Bearing the UL Classification Mark
<br />Last Updated on 2011-06-25
<br />Questions? Print this page Notice of Disclaimer Page Too
<br />© 2012 UL LLC
<br />The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
<br />under UUs Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up
<br />Service. Always look for the Mark on the product.
<br />UL permits the reproduction of the material contained In the Online Certification Directory subject to the following conditions: 1. The Guide
<br />Information, Designs and/or Listings (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data
<br />(or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted
<br />material. In addition, the reprinted material must Include a copyright notice In the following format: "© 2012 UL LLC".
<br />UL RATED THRU-WALL PENETRATION - RATING SAME AS WALL RATING
<br />SCALE NTS
<br />LIGHTNING STEEL
<br />CG19-014
<br />CONNELLY GROUP
<br />CONSULTING INGIN19R8
<br />Q200
<br />2nd Ave South - *465 - St Petersburg, FL 33701
<br />info@connellyengineering.com
<br />9
<br />(T) 813, 232. 8448 (F) 800. 698. 1945
<br />CO
<br />U7
<br />www.connellyengineering.—
<br />r
<br />C"
<br />O
<br />N
<br />\
<br />FBC'CHOPTER I
<br />A BIIAiL BE CONSTRUCTED TO SE A LMM TO PROCEED WrrH THE wax
<br />SIDE MY OF THE PROVISIONS
<br />OF THE ECHMCAiCME0 AUTHORITY SBORS u ICEL ALTOR ER MVENT THE KUM
<br />PROJECT
<br />DATA
<br />-
<br />DESIGNER
<br />\
<br />OiFE AL FROM THEREAFTER RERNIO A CORRECTION OF ER OS BI PLARL
<br />CMYRUCTIOM OR VIOLATORS OF THIS CODE FIRM PERMIT MM SHALL BECOMECRC
<br />WVALUO MISS THE WORK NnIIOR®BT SUCH PERMIT S COMMMM WHEN SIX
<br />MONTHS AFTER in MIS AWL ON r THE Wax AUTKEOEO BT S!" POW IS
<br />KWENDED OR ABAM70 M FOR A PERIOO OF BR ARMTHS AFTER THE THE THE WORK 16
<br />DRAWN BY
<br />JJC
<br />W
<br />QMEEAEN
<br />SOFTHEATP CAMPURLRRDDx000 BPEF ONTHET TTMINEET
<br />CHECKED
<br />C
<br />CRC
<br />IH
<br />O
<br />J
<br />a
<br />I—
<br />LU
<br />LIJ
<br />MC
<br />fn
<br />a
<br />e
<br />a
<br />FBCu�
<br />r`
<br />O
<br />6TH EDITION
<br />IU
<br />(2017)
<br />a
<br />CONNELLY GROUP CONSULTING ENGINEERS AND THEIR
<br />c
<br />AGENTS, RESERVES THE RIGHT TO REVISE DETAILS
<br />LIJ
<br />SHOWN HERE AT SUCH TIME AS REVISIONS WILL RESULT
<br />IN ENGINEERING OR ECONOMIC IMPROVEMENTS. THESE
<br />N
<br />DRAWINGS ARE GRAPHIC REPRESENTATION OF A DESIGN
<br />CONCEPT. ACTUAL DETAILS SUBJECT TO FIELD
<br />LU
<br />VERIFICATION.
<br />s
<br />w
<br />W
<br />W
<br />N
<br />41140
<br />C3 Ln
<br />cn
<br />O
<br />1=
<br />M
<br />O
<br />>MNM U
<br />1=
<br />Z
<br />W
<br />c)
<br />CJ U)
<br />J
<br />%#0
<br />0
<br />J
<br />V
<br />o
<br />C3
<br />Ln
<br />LL.LL-
<br />N
<br />3
<br />z
<br />is W
<br />d' N
<br />DRAWING SETS
<br />REVIEW 11.14.16 (01) - 12.04.18102)
<br />BID 00.00.00
<br />PERMIT (8D REVIEW) 08.06.19
<br />PROFESSIONAL SEAL
<br />DATE SEALED: SEPTEMBER 6, 2018
<br />4N...
<br />/ VI
<br />001,
<br />LU
<br />CHRISTOPHER R. CONNELLY, PE
<br />a
<br />PE-FL83888 i CA+L 26841
<br />J
<br />a
<br />UL RATINGS