1 I 2 <br />3 <br />4 1 5 <br />I <br />A <br />I <br />0 <br />E. STRUCTURAL STEEL <br />1. ALL STRUCTURAL STEEL HAS BEEN DESIGNED AND SHALL BE FABRICATED AND ERECTED IN <br />ACCORDANCE WITH THE "BUILDING CODE", ANSUAISC 360-10 "SPECIFICATION FOR STRUCTURAL <br />STEEL BUILDINGS" (22 JUNE 2010), AND THE AISC STEEL CONSTRUCTION MANUAL (14TH EDITION) <br />CONFORMING TO THE PROVISIONS OF THE LOAD RESISTANCE FACTOR DESIGN (LRFD). <br />A. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE <br />REQUIREMENTS OF THE CURRENT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) <br />STEEL ERECTION STANDARDS 29-CFR, SUBPART R. <br />2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS UNLESS NOTED OTHERWISE <br />ON THE DRAWINGS - <br />TYPE <br />ASTM <br />GRADE <br />FY (MIN.) <br />(KSI) <br />STRUCTURAL WIDE FLANGE BEAMS AND COLUMNS <br />(W - SHAPES) <br />A992 <br />50 <br />STRUCTURAL CHANNELS AND ANGLES (C, MC, AND <br />L - SHAPES) <br />A36 <br />---- <br />36 <br />STRUCTURAL PLATES AND BARS (TYPICAL U.N.O.) <br />A36 <br />----- <br />36 <br />HOLLOW STRUCTURAL SECTIONS (HSS - SHAPES - <br />RECTANGULAR OR SQUARE) <br />A500 <br />C <br />50 <br />THREADED RODS <br />A36 <br />26 <br />STRUCTURAL ANCHOR RODS* <br />F1554 <br />----- <br />36 <br />WITH WELDABILITY SUPPLEMENT S1 <br />& CARBON EQUIVALENT FORMULA <br />PER ASTM F1554 SECTION 1.5.2.1 <br />STRUCTURAL HIGH STRENGTH BOLTS <br />A325 <br />------ <br />Fu = 120 KSI <br />HEADED SHEAR STUD CONNECTORS <br />A108 <br />TYPE B <br />51, Fu = 65 <br />KSI <br />* STRUCTURAL ANCHOR RODS SHALL MEET THE REQUIREMENTS OF A DUCTILE STEEL <br />ELEMENT PER ACI 318. A DUCTILE STEEL ELEMENT HAS TENSILE TEST ELONGATION OF AT LEAST <br />14 PERCENT AND REDUCTION IN AREA OF AT LEAST 30 PERCENT. <br />3. ALL WELDING FOR STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH RISC 360 AND AWS <br />D1.1-10 "STRUCTURAL WELDING CODE - STEEL". ALL WELDS SHALL USE E70XX ELECTRODES (Fu <br />= 70 KSI) UNLESS NOTED OTHERWISE. <br />4. SPLICES SHALL BE ALLOWED ONLY AT LOCATIONS SPECIFICALLY INDICATED ON THE <br />STRUCTURAL DRAWINGS UNLESS APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF <br />RECORD PRIOR TO TO BEGINNING FABRICATION OR CONSTRUCTION. <br />5. ALL COPES, HOLES, OPENINGS AND MODIFICATIONS REQUIRED IN STRUCTURAL STEEL MEMBERS <br />FOR ERECTION OR THE WORK OF OTHER TRADES SHALL BE SHOWN ON THE STRUCTURAL STEEL <br />SHOP DRAWINGS AND REQUIRE APPROVAL BY THE STRUCTURAL ENGINEER OF RECORD PRIOR <br />TO FABRICATION. <br />6 FIELD MODIFICATIONS (HOLES, LENGTH ADJUSTMENTS, ETC.) TO STRUCTURAL STEEL IS <br />PROHIBITED WITHOUT PRIOR APPROVAL BY THE STRUCTURAL ENGINEER OF RECORD. <br />.7. WHERE NO CAMBER. IS INDICATED, FABRICATE STEEL BEAMS $O THAT ANY NATURAL CAMBER IS <br />UPWARD AFTER ERECTION. <br />F. STEEL DECK <br />1. STEEL ROOF DECKS SHALL COMPLY WITH THE REQUIRMENTS OF THE "BUILDING CODE" AND <br />THE LATEST EDITION OF THE STEEL DECK INSTITUTE (SDI) SPECIFICATIONS FOR STEEL DECKS. <br />2. STEEL ROOF DECK SHALL BE 1-1/2 INCH DEEP WIDE RIB (TYPE B) STEEL ROOF DECK WITH AN <br />UNCOATED DESIGN THICKNESS OF 0.0358 IN. (20 GA.). DECKING SHALL HAVE A MINIMUM YIELD <br />STRENGTH OF 33 KSI, A MINIMUM ip OF 0.201 IN.^4/FT., A MINIMUM In OF 0.222 IN."4/FT., A <br />MINIMUM Sp OF 0.234 IN.^3/FT., AND A MINIMUM Sn OF 0.247 IN.^WT.. DECKING SHALL RECEIVE A <br />G60 GALVANIZED FINISH. DECKING SHALL BE CONTINUOUS OVER A MINIMUM OF THREE <br />SUPPORTS WITHOUT INTERRUPTION. EACH DECK.UNIT SHALL BE ATTACHED TO SUPPORTING <br />MEMBERS AND ADJACENT PANELS AS SHOWN ON THE'TYPICAL STEEL ROOF DECK SUPPORT <br />AND SIDELAP ATTACHMENT DETAIL". <br />3. ALL ROOF DECK OPENINGS GREATER THAN 6 INCHES WIDE MEASURED PARALLEL TO THE <br />SUPPORTING MEMBERS SHALL BE FRAMED WITH STEEL ANGLES AS SHOWN ON THE TYPICAL <br />ROOF DECK OPENING FRAMING DETAILS" UNLESS NOTED OTHERWISE. <br />4. LOADS SHALL NOT BE DIRECTLY HUNG FROM THE ROOF DECK WITHOUT PRIOR REVIEW AND <br />APPROVAL BY THE DECK SUPPLIER AND REVIEW BY THE STRUCTURAL ENGINEER OF RECORD. <br />5. COMPOSITE STEEL ROOF DECK SHALL BE 3 INCH DEEP COMPOSITE STEEL DECK WITH AN <br />UNCOATED DESIGN THICKNESS OF 0.0358 IN. (20 GA.). DECKING SHALL HAVE A MINIMUM YIELD <br />STRENGTH OF 50 KSI, A MINIMUM Ip OF 0.920 IN.^4/FT., A MINIMUM In OF 0.919 IN."4/FT., A <br />MINIMUM Sp OF 0.534 IN."3/FT., AND A MINIMUM Sn OF 0.551 IN."3/FT.. DECKING SHALL RECEIVE <br />A G60 GALVANIZED FINISH. DECKING SHALL BE CONTINUOUS OVER A MINIMUM OF THREE <br />SUPPORTS WITHOUT INTERRUPTION. <br />6. NO OPENINGS SHALL BE ALLOWED IN COMPOSITE STEEL ROOF DECK. <br />7. COMPOSITE STEEL DECK HANGER TAB LOADS SHALL NOT EXCEED 60 LBS. PER HANGER TAB <br />OR THE DECK MANUFACTURER'S RECOMMENDED ALLOWABLE HANGER TAB LOAD. IN ADDITION, <br />LOADS ON HANGERS SHALL BE DISTRIBUTED IN SUCH A MANNER THAT THE TRIBUTARY LOADS <br />FOR EACH HANGER DOES NOT EXCEED 5 PSF. DO NOT HANG MEP EQUIPMENT AND PIPING <br />DIRECTLY FROM COMPOSITE STEEL DECK <br />F. STEEL DECK <br />8. ALL WELDING FOR STEEL DECK SHALL BE IN ACCORDANCE WITH AWS D1.3-08, "STRUCTURAL <br />WELDING CODE -SHEET STEEL". USE E60XX ELECTRODES (Fu = 60 KSI) FOR WELDING STEEL <br />ROOF DECK, COMPOSITE STEEL DECK, AND NON -COMPOSITE STEEL DECK WITH A THICKNESS <br />OF 0.0295 INCH (22 GA.) OR GREATER TO SUPPORTING STEEL MEMBERS UNLESS NOTED <br />OTHERWISE. USE E70XX ELECTRODES (Fu = 70 KSI) FOR WELDING NON -COMPOSITE STEEL <br />DECK WITH A THICKNESS LESS THAN 0.0295 INCH (22 GA.) TO SUPPORTING STEEL MEMBERS. <br />WELDING WASHERS SHALL BE USED ON ALL DECK UNITS WITH A THICKNESS LESS THAN 0.0295 <br />INCH (22 GA.). <br />9. COMPOSITE CONSTRUCTION NOTES - <br />A. THE COMPOSITE FLOOR SYSTEM INCLUDING COMPOSITE STEEL BEAMS AND CONCRETE SLABS 4. <br />ON COMPOSITE STEEL ROOF DECKS HAVE BEEN DESIGNED UNSHORED. <br />B. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING FOR THE CONCRETE SLABS ON 5. <br />COMPOSITE STEEL ROOF DECK, IF NECESSARY, IN ACCORDANCE WITH THE DECK <br />MANUFACTURER'S RECOMMENDATIONS FOR THE SPAN AND SPAN CONDITIONS INDICATED. <br />C. CONDUITS AND PIPES SHALL NOT BE EMBEDDED IN THE CONCRETE SLABS ON COMPOSITE <br />STEEL ROOF DECK. <br />D. CONDUITS, PIPES, AND SLEEVES SHALL NOT PENETRATE VERTICALLY THROUGH THE 6. <br />CONCRETE SLABS ON COMPOSITE STEEL DECK OR THE COMPLETED. COMPOSITE STEEL DECK <br />SYSTEM WITHOUT WRITTEN APPROVAL FROM THE STRUCTURAL EOR, EXCEPT THAT (3) - 3 INCH <br />DIAMETER PIPE SLEEVES WILL BE ALLOWED FOR THE HVAC SYSTEM. WHERE ALLOWED BY THE <br />EOR, VERTICAL PENETRATIONS THROUGH CONCRETE SLABS ON COMPOSITE STEEL ROOF <br />DECK SHALL BE ACCOMPLISHED USING SLEEVES THAT COMPLY WITH ICC-500, CORED <br />PENETRATIONS WILL NOT BE ALLOWED. THE CONTRACTOR SHALL SUBMIT STEEL DECK SHOP <br />DRAWINGS. WHERE ALLOWED BY THE EOR, THE STEEL DECK SHOP DRAWINGS SHALL INDICATE <br />THE SIZE AND LOCATION OF ALL PENETRATIONS THROUGH THE CONCRETE SLABS ON 7. <br />COMPOSITE STEEL ROOF DECK FOR REVIEW BY THE STRUCTURAL ENGINEER PRIOR TO <br />FABRICATION AND CONSTRUCTION OF THE DECKING. <br />E. ` STEEL HEADED SHEAR STUD CONNECTORS USED FOR COMPOSITE BEAMS SHALL CONFORM TO <br />THE REQUIREMENTS OF AWS D1.1-10 "STRUCTURAL WELDING CODE - STEEL" AND ASTM A108, <br />TYPE B, Fu = 65 KSI, Fy = 51 KSI. PROVIDE STEEL HEADED STUDS CONNECTORS OF QUANTITY, <br />SIZE, AND LENGTH AS INDICATED ON THE DRAWINGS. <br />F. STEEL HEADED SHEAR STUD CONNECTORS USED AS SHEAR CONNECTORS FOR COMPOSITE <br />STEEL BEAMS SHALL BE WELDED AND TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF <br />AWS D1.1-10. LOCATE AND INSTALL ALL STEEL HEADED SHEAR STUD CONNECTORS THROUGH <br />COMPOSITE STEEL ROOF DECK IN THE "STRONG" POSITION AS DEFINED IN AISC 360. <br />G. MISCELLANEOUS <br />E. THE GENERAL CONTRACTOR SHALL REVIEW AND APPROVE ALL SHOP DRAWINGS PRIOR TO <br />SUBMITTAL NOTING CHANGES MADE WHICH DO NOT COMPLY WITH CONTRACT DOCUMENT <br />DRAWINGS AND SPECIFICATIONS. PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL <br />ENGINEER OF RECORD AND ARCHITECT SHALL BE REQUIRED FOR ALL DEVIATIONS FROM THE <br />CONTRACT DOCUMENTS MADE BY THE CONTRACTOR. REQUEST FOR INFORMATION SHALL <br />NOT BE USED TO INTRODUCE SUBSTITUTIONS, DEVIATIONS, OR CHANGES FROM THE <br />REQUIREMENTS INDICATED BY THE CONSTRUCTION DOCUMENTS. <br />F. DESIGN AND PROVIDE TEMPORARY BRACING AND SHORING AS REQUIRED FOR STABILITY <br />DURING CONSTRUCTION. <br />PLANS, SECTIONS, AND DETAILS SHALL NOT BE SCALED FOR DETERMINATION OF QUANTITIES, <br />LENGTHS, OR FIT OF MATERIALS. <br />SEE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DESIGN DOCUMENTS FOR SIZE AND <br />LOCATION OF ALL OPENINGS, SLEEVES, CURBS, PADS, INSERTS, ETC. NOT SHOWN ON <br />STRUCTURAL DRAWINGS. BEFORE FABRICATION OF MATERIALS, COORDINATE WITH <br />ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND SPECIFICATIONS AND <br />PROVIDE ALL MISCELLANEOUS AND STRUCTURAL ITEMS INDICATED OR REQUIRED TO <br />COMPLETE THE WORK. <br />THE DESIGN DOCUMENTS REFLECT THE FINAL COMPLETED STATE OF THE STRUCTURAL <br />SYSTEMS AND ELEMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION <br />RELATED ENGINEERING TO INCLUDE BUT NOT BE LIMITED TO CONSTRUCTION MEANS AND <br />METHODS, TEMPORARY SUPPORTS, SHORING AND BRACING, TEMPORARY USE OF <br />STRUCTURES, PARTIALLY CONSTRUCTED STRUCTURES AND INCOMPLETE STRUCTURES. ALL <br />CONSTRUCTION AND RELATED ENGINEERING SHALL BE IN ACCORDANCE WITH ASCE 37-14 <br />"DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION". <br />SPECIAL INSPECTIONS AND STRUCTURAL TESTS SHALL BE PERFORMED IN ACCORDANCE WITH <br />THE MORE STRINGENT REQUIREMENTS OF THE PROJECT CONTRACT DOCUMENTS DRAWINGS, <br />THE "BUILDING CODE" (AS DEFINED ON.SHEET S-001), AND AS DIRECTED BY THE BUILDING <br />OFFICIAL. <br />THE OWNER SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PERFORM INSPECTIONS <br />DURING CONSTRUCTION ON THE TYPES OF WORK LISTED UNDER IBC 2012 SECTION 1705 IN <br />ADDITION TO THE INSPECTIONS IDENTIFIED IN IBC 2015 SECTION 110 AND TO PROVIDE TESTING <br />AND INSPECTIONS INDICATED IN THE PROJECT DRAWINGS AND SPECIFICATIONS. <br />AN APPROVED AGENCY SHALL BE OBJECTIVE, COMPETENT AND INDEPENDENT FROM THE <br />CONTRACTOR RESPONSIBLE FOR THE WORK BEING INSPECTED. <br />THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSONS) WHO SHALL DEMONSTRATE <br />G. HEADED SHEAR STUD CONNECTORS SHALL BE SPACED EQUALLY ALONG THE CENTERLINE OF COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE <br />THE STEEL BEAM. THE SPACING OF THE HEADED SHEAR STUD CONNECTORS ALONG THE PARTICULAR TYPE OF CONSTRUCTION OF OPERATION REQUIRING SPECIAL INSPECTION. <br />LENGTH OF A SUPPORTING STEEL BEAM SHALL NOT EXCEED 12 INCHES. <br />THE CONTRACTOR SHALL COORDINATE AND PROVIDE SUFFICIENT NOTIFICATION AND ACCESS <br />H. PROVIDE HEADED SHEAR STUD CONNECTORS AT 12 INCHES ON CENTER FOR ALL STEEL BEAMS FOR ALL TESTING AND INSPECTION. <br />AND GIRDERS SUPPORTING CONCRETE SLABS ON COMPOSITE STEEL ROOF DECK WHERE <br />HEADED SHEAR STUD CONNECTORS ARE NOT INDICATED ON THE DRAWINGS. H. STRUCTURAL SPECIAL INSPECTIONS AND TESTS <br />1. IBC 2015 SPECIAL INSPECTIONS AND TESTS - GENERAL REQUIREMENTS - <br />I. PROVIDE STEEL DECK SHOP DRAWINGS SHOWING EXACT LAYOUT OF COMPOSITE BEAM STEEL A. THE CONTRACTOR SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PERFORM <br />HEADED SHEAR STUD CONNECTORS FOR EACH SPAN AND DECK INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF WORK LISTED UNDER IBC 2015 SECTION <br />1705 "REQUIRED SPECIAL INSPECTIONS AND TESTS" AND SPECIFICATION 014000 "QUALITY <br />REQUIREMENTS". THESE INSPECTIONS ARE IN ADDITION TO THE INSPECTIONS DEFINED IN IBC <br />G. MISCELLANEOUS 2015 SECTION 110. THE INSPECTING AGENCY MUST PROVIDE REPORTS OF THE SPECIAL <br />INSPECTIONS DIRECTLY TO THE GENERAL CONTRACTOR. <br />1. SHOP DRAWINGS SHALL BE ORIGINAL DRAWINGS, PREPARED BY THE CONTRACTOR, <br />SUBCONTRACTOR, SUPPLIER OR DISTRIBUTOR. REPRODUCTION OF STRUCTURAL CONTRACT <br />DOCUMENTS AS ERECTION PLANS OR DETAILS WILL NOT BE PERMITTED AND WILL BE <br />REJECTED WITHOUT REVIEW. ALL SHOP DRAWINGS SHALL BE REVIEWED AND STAMPED BY <br />THE CONTRACTOR PRIOR TO SUBMITTAL FOR REVIEW. <br />2. THE CONTRACTOR SHALL DESIGN AND PROVIDE ALL ITEMS REQUIRED FOR ATTACHING <br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, EQUIPMENT AND ELEMENTS TO THE BUILDING <br />STRUCTURE AND TO RESIST ALL LOADS INCLUDING SEISMIC LOADS. ATTACHMENT SHALL BE <br />MADE SO AS NOT TO OVERSTRESS THE STRUCTURAL MEMBERS. THE CONTRACTOR SHALL <br />COORDINATE THE ATTACHMENTS AND LOCATIONS OF THE EQUIPMENT AND ELEMENTS AND <br />INCORPORATE THEIR REQUIREMENTS INTO THE STRUCTURAL STEEL SHOP DRAWINGS. THE <br />SHOP DRAWING SUBMITTAL SHALL INCLUDE ATTACHMENT CALCULATIONS AND SHALL BE <br />SEALED AND SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE <br />PROJECT IS LOCATED. REFER TO THE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL <br />DESIGN DOCUMENTS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. <br />3. THE CONTRACTOR SHALL INCLUDE AND PROVIDE THE FOLLOWING SERVICES - <br />A. VERIFICATION OF ALL DIMENSIONS, ELEVATIONS, OPENING SIZES, AND EQUIPMENT WEIGHTS <br />PRIOR TO STARTING WORK AND INCORPORATE THIS INFORMATION INTO THE PROJECT SHOP <br />AND ERECTION DRAWINGS. <br />B. VERIFICATION OF ALL DIMENSIONS AND MEMBER SIZES RELATING TO ALL EXISTING <br />CONSTRUCTION AND CONDITIONS. <br />C. VERIFICATION OF ALL FLOOR DRAINS, SLOPED FLOORS, FLOOR DEPRESSIONS AND OFFSETS <br />WITH THE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS PRIOR TO THE <br />SUBMITTAL OF STRUCTURAL STEEL, STEEL DECK, AND CONCRETE REINFORCEMENT SHOP <br />DRAWINGS. <br />D. COORDINATE .WITH THE OWNER AND REMOVE ALL ABANDONED FOUNDATIONS, UTILITIES, <br />PIPELINES, ETC. THAT MAY INTERFER WITH THE NEW CONSTRUCTION. <br />2. STATEMENT OF SPECIAL INSPECTIONS: THIS "STATEMENT OF SPECIAL INSPECTIONS" HAS BEEN <br />PREPARED IN ACCORDANCE WITH THE SPECIAL INSPECTION AND TESTING REQUIREMENTS OF <br />IBC 2015 SECTION 1704. THIS "STATEMENT OF SPECIAL INSPECTIONS" ENCOMPASSES THE <br />FOLLOWING DISCIPLINE: STRUCTURAL. IT INCLUDES THE SCHEDULE OF "IBC 2015 - REQUIRED <br />SPECIAL INSPECTIONS AND TESTS" NOTED BELOW THAT ARE APPLICABLE TO THE PROJECT. <br />3. IBC 2015 - REQUIRED SPECIAL INSPECTIONS AND TESTS - <br />A. SPECIAL INSPECTIONS AND TESTS OF ELEMENTS AND NONSTRUCTURAL COMPONENTS OF <br />BUILDINGS AND STRUCTURES SHALL MEET THE APPLICABLE REQUIREMENTS OF THE IBC 2015 <br />SECTION 1705 AND THE CONTRACT DOCUMENTS. <br />TYPE OF CONSTRUCTION <br />IBC 2015 <br />SECTION <br />INSPECTION <br />REQUIRED <br />YES <br />NO <br />NIA <br />1. <br />STEEL CONSTRUCTION <br />1705.2 <br />X <br />- <br />A. <br />STRUCTURAL STEEL <br />1705.2.1 <br />X <br />- <br />- <br />B. <br />COLD -FORMED STEEL DECK <br />1705.2.2 <br />X <br />- <br />- <br />2. <br />CONCRETE CONSTRUCTION <br />1705.3 <br />X <br />- <br />- <br />3. <br />MASONRY CONSTRUCTION <br />1705.4 <br />X <br />- <br />- <br />4. <br />SOILS <br />1705.6 <br />X <br />- <br />- <br />5. <br />FABRICATED ITEMS <br />1705.10 <br />X <br />- <br />- <br />6. <br />SPECIAL INSPECTIONS FOR WIND RESISTANCE <br />1705.11 <br />X <br />- <br />- <br />7. <br />TESTING FOR SEISMIC RESISTANCE <br />1705.13 <br />NCIO is off& nAw <br />a WaSkell convany <br />ENGINEERING $31348 <br />STUART T. WEBB <br />STRUCTURAL ENGINEER <br />a <br />U� <br />o) <br />N <br />a <br />00 <br />0 <br />z <br />O <br />U. <br />z <br />z <br />Oo <br />O <br />w <br />D. <br />V) <br />0 <br />co <br />�N <br />U �ti <br />W CN <br />o <br />cis <br />J <br />cM <br />Nw O <br />= 9 <br />z F- G a <br />cl) N J lm m. LL x <br />W <br />M <br />Q � _ <br />a <br />LLJ <br />00 <br />.w� N <br />w <br />z <br />u <br />C� <br />z <br />c <br />O <br />m <br />O <br />z <br />z <br />zOC <br />J <br />a <br />z <br />O� <br />cl) <br />Q) <br />J <br />w <br />m <br />Q <br />z <br />z <br />w <br />z <br />O <br />w <br />5 <br />m <br />-11) <br />w <br />0- <br />SHEET <br />IDENTIFICATION <br />S-003 <br />