My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4330 20th St (39)
Zephyrhills
>
Building Department
>
Building Plans
>
4330 20th St (39)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 9:02:07 AM
Creation date
2/18/2025 3:18:31 PM
Metadata
Fields
Template:
Building Plans
Street #
4330
Location
20th St
Contractor
Alston Construction
Building Plans - Permit #
22093
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 <br />3 <br />4 1 5 <br />A. DESIGN CRITERIA <br />1. "BUILDING CODE" -"INTERNATIONAL BUILDING CODE 2015" (IBC 2015) AS <br />SUPPLEMENTED BY ASCE 7 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER <br />STRUCTURES" (2010) AND MODIFIED BY STRUCTURAL REQUIREMENTS AND CRITERIA <br />SPECIFIED BY ICC / NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF <br />STORM SHELTERS 2014 (ICC 500-2014) (INCLUDING ALL LOCAL REQUIREMENTS AND <br />AMENDMENTS TO THE "BUILDING CODE") <br />2. <br />A <br />3 <br />LIVE LOADS DETERMINED IN ACCORDANCE WITH THE "BUILDING CODE". <br />LOCATION <br />MINIMUM <br />UNIFORMLY <br />DISTRIBUTED <br />LIVE LOAD <br />MINIMUM <br />CONCENTRATED <br />LIVE LOAD <br />ROOF - (CANOPY AREA) <br />20 PSF <br />300 LBS <br />ROOFS (MINIMUM) PER ICC-500 <br />100 PSF <br />------ <br />ROOFS (MINIMUM) PER ICC--500 <br />100 PSF <br />---- <br />SNOW LOADS - N/A <br />4. WIND LOADS DETERMINED IN ACCORDANCE WITH. THE STRUCTURAL REQUIREMENTS <br />AND THE CRITERIA AS SPECIFIED IN THE BUILDING CODE AND ICC/NSSA STANDARD <br />FOR THE DESIGN AND CONSTRUCTION OF STORM.SHELTERS 2014 (ICC 500-2014). <br />I <br />0 <br />5 <br />0 <br />WIND LOAD PARAMETERS - <br />BUILDING ADDITION: <br />RISK CATEGORY <br />it <br />NOMINAL DESIGN WIND <br />SPEED <br />Vasd = 250 <br />MPH <br />(ICC 500, SECTION 304.2) <br />WIND EXPOSURE CATEGORY <br />C <br />(ICC 500, SECTION 304.4) <br />INTERNAL PRESSURE <br />COEFFICIENT <br />GCpi = <br />+/-0.55 <br />(ASCE 7, TABLE 26.11-1, PARTIALLY <br />ENCLOSED) <br />DIRECTIONALITY FACTOR <br />Kd = 1.0 <br />(ICC 500, SECTION 304.3) <br />CANOPY AND PARAPET: <br />RISK CATEGORY <br />II <br />WIND IMPORTANCE FACTOR <br />Iw = 1.0 <br />(ASCE 7) <br />ULTIMATE DESIGN WIND <br />SPEED <br />Vug = 140 <br />MPH <br />(ASCE 7) <br />WIND EXPOSURE CATEGORY <br />C <br />(ASCE 7) <br />INTERNAL PRESSURE <br />COEFFICIENT <br />GCpi = <br />+/-0.55 <br />(ASCE 7; PARTIALLY ENCLOSED) <br />DEBRIS CRITERIA - <br />TORNADO MISSILE IMPACT <br />CRITERIA <br />(ICC 500, SECTION 305) <br />MISSILE SIZE <br />15 lb. 2x4 <br />MISSILE SPEED (VERTICAL <br />SURFACES) <br />100 MPH <br />MISSILE SPEED (HORIZONTAL <br />SURFACES). <br />67 MPH <br />SEISMIC LOADS DETERMINED IN ACCORDANCE WITH THE "BUILDING CODE". <br />DESCRIPTION OF THE STRUCTURE AND LATERAL FORCE RESISTING SYSTEM: ALL <br />LATERAL LOAD RESISTANCE AND STABILITY OF THE BUILDING IN THE COMPLETED <br />STRUCTURE IS PROVIDED BY BEARING WALL SYSTEM WITH ORDINARY REINFORCED <br />MASONRY SHEAR WALLS. THE CONCRETE ROOF SLAB ON COMPOSITE STEEL DECK <br />SERVES AS HORIZONTAL DIAPHRAGM THAT DISTRIBUTES THE LATERAL WIND AND <br />SEISMIC LOADS HORIZONTALLY TO THE VERTICAL MASONRY SHEAR WALLS. THE <br />VERTICAL MASONRY SHEAR WALLS CARRY THE APPLIED LOADS TO THE BUILDING <br />FOUNDATIONS. <br />SEISMIC DESIGN PARAMETERS - <br />RISK CATEGORY <br />II <br />SEISMIC IMPORTANCE FACTOR <br />l e = 1.0 <br />MAPPED SPECTRAL RESPONSE <br />ACCELERATION AT SHORT PERIOD <br />SS = 0.068g <br />MAPPED SPECTRAL RESPONSE <br />ACCELERATION AT PERIOD OF 1 SECOND <br />S , = 0.034g <br />SITE CLASSIFICATION <br />CLASS D* <br />DESIGN SPECTRAL RESPONSE <br />ACCELERATION AT SHORT PERIOD <br />SDS= 0.072g <br />(CALCULATED) <br />DESIGN SPECTRAL RESPONSE <br />ACCELERATION AT A PERIOD OF 1 SECOND <br />SDI = 0.055g <br />(CALCULATED) <br />SEISMIC DESIGN CATEGORY <br />I A <br />* SITE CLASSIFICATION ASSUMED AS "CLASS D", PER IBC 2015 SECTION 16.13.3.2. <br />CALCULATED SAS, SDI, CS, AND SEISMIC DESIGN CATEGORY BASED ON ASSUMED <br />SITE CLASSIFICATION. <br />LOAD COMBINATIONS ARE IN ACCORDANCE WITH THE "BUILDING CODE" (IBC 2015, <br />SECTION 1605.2). <br />A. DESIGN CRITERIA <br />7. NO PROVISIONS FOR ANY FUTURE BUILDING EXTENSION OR ADDITION HAVE BEEN <br />MADE IN THE STRUCTURAL DESIGN. <br />8. PROJECT PROVIDES AN OPEN MEETING ROOM LOCATED OUTSIDE OF AN EXISTING <br />BUILDING. THE OPEN MEETING ROOM IS DESIGNED TO MEET ICC 500-2014 <br />STRUCTURAL CRITERIA TO FUNCTION AS A HARDENED AREA. <br />B. SOIL PREPARATION AND FOUNDATIONS <br />1. FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS <br />CONTAINED IN THE "GEOTECHNICAL ENGINEERING REPORT" PREPARED FOR THE PROJECT BY <br />TERRACON CONSULTANTS, INC. DATED FEBRUARY 12, 2019. <br />A. THE CONTRACTOR MAY NOT RELY UPON NON -TECHNICAL DATA, OPINIONS, OR <br />INTERPRETATIONS FOUND IN THE GEOTECHNICAL REPORT IDENTIFIED ABOVE NOR UPON THE <br />COMPLETENESS THEREOF FOR CONTRACTORS PURPOSES. COPIES OF THE AFOREMENTIONED 3. <br />GEOTECHNICAL REPORT ARE NOT INCLUDED WITH THE BIDDING DOCUMENTS. THE <br />GEOTECHNICAL REPORT IS NOT PART OF THE CONTRACT DOCUMENTS, BUT THE TECHNICAL <br />DATA CONTAINED: THEREIN UPON WHICH THE CONTRACTOR IS ENTITLED TO RELY, AS <br />SPECIFICALLY LISTED IN THE FOREGOING SUBPARAGRAPH, IS INCORPORATED INTO THE <br />CONTRACT DOCUMENTS BY REFERENCE. <br />2. ALL EXCAVATION, FILL, COMPACTION, PREPARATION AND GRADING OF THE SITE SHALL BE IN <br />ACCORDANCE WITH IBC 2015 AND OSHA REQUIREMENTS <br />3. SOIL SUPPORTED FOUNDATIONS <br />A. DESIGN BEARING PRESSURE (NET) IS 2,500 PSF FOR SPREAD FOOTING SHALLOW FOUNDATIONS <br />BEARING ON UNDISTURBED FIRM SUBGRADE SOIL OR APPROVED STRUCTURAL FILL MATERIAL. <br />DESIGN VALUES AND BEARING MATERIALS SHALL BE VERIFIED AND APPROVED BY A QUALIFIED <br />LICENSED GEOTECHNICAL ENGINEER. <br />B. MAT SLAB FOUNDATIONS SHALL BE PLACED ON APPROVED COMPACTED STRUCTURAL FILL OR <br />ON APPROVED UNDISTURBED NATIVE MATERIAL. <br />C. FOUNDATION REINFORCING SHALL BE SUPPORTED FROM ABOVE OR WITH 3 INCH BAR <br />SUPPORTS AT 4 FEET ON CENTER (MAX.) WHILE DEPOSITING CONCRETE IN FORMS. <br />D. MOISTURE CONTENT IN MAT SLAB FOUNDATION EXCAVATIONS NECESSARY TO PREVENT LOSS <br />OF COMPACTION SHALL BE MAINTAINED UNTIL MAT SLAB FOUNDATION ARE PLACED. MAT SLAB <br />FOUNDATION SHALL BE POURED AS SOON AS PRACTICAL AFTER EXCAVATION AND SUBGRADE <br />PREPARATION ARE COMPLETED. IN NO CASE SHALL EXCAVATIONS BE ALLOWED TO REMAIN <br />OPEN OVERNIGHT. <br />E. A MODULUS OF SUBGRADE REACTION VALUE (k) EQUAL TO 150 PCI HAS BEEN USED TO DESIGN <br />THE MAT SLAB FOUNDATIONS BEARING ON COMPACTED AGGREGATE OVER APPROVED <br />COMPACTED STRUCTURAL FILL. CONTRACTOR SHALL COORDINATE AND VERIFY MODULUS OF <br />SUBGRADE REACTION WITH GEOTECHNICAL ENGINEER. <br />C. CAST -IN -PLACE CONCRETE <br />1. ALL STRUCTURAL CAST -IN -PLACE CONCRETE HAS BEEN DESIGNED AND SHALL BE <br />CONSTRUCTED IN ACCORDANCE WITH THE "BUILDING CODE" AND ACI 318-14 "BUILDING CODE <br />REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY". <br />2. CONCRETE REQUIREMENTS <br />A. CONCRETE FOR THE STRUCTURE INDICATED ON THE CONTRACT DOCUMENTS HAS BEEN <br />ASSIGNED THE FOLLOWING EXPOSURE CLASSES IN ACCORDANCE WITH ACI 318, SECTION <br />19.3.1 <br />LOCATION <br />EXPOSURE CLASSES - <br />EXTERIOR FOUNDATIONS <br />FO, SO, PO, CO <br />EXTERIOR SLAB ON STEEL DECK <br />FO, SO, PO, CO <br />BASED ON THE EXPOSURE CLASSES ASSIGNED, CONCRETE MIXTURES SHALL COMPLY WITH <br />THE MOST RESTRICTIVE REQUIREMENTS ACCORDING TO ACI 318, TABLE 19.3.2.1 <br />B. CAST -IN -PLACE CONCRETE 28-DAY SPECIFIED COMPRESSIVE STRENGTHS AND PROPERTIES <br />LOCATION <br />MIN. <br />fc <br />(PSI) <br />UNIT <br />WEIGHT <br />(PCF) <br />MAX. <br />W/C <br />RATIO <br />AIR <br />ENT. <br />% <br />EXTERIOR FOUNDATIONS <br />4000 <br />145t5 <br />0.45 <br />6 +/- 1.5 <br />EXTERIOR SLAB ON STEEL DECK <br />4000 <br />145t5 <br />0.50 <br />6 +/- 1.5 <br />C. PROVIDE TYPE 1 / it PORTLAND CEMENT MEETING THE REQUIREMENTS OF ASTM C150. <br />D. FLY ASH ON NATURAL POZZOLAN USED AS ADMIXTURES SHALL CONFORM TO ASTM C618. <br />E. PROVIDE CONCRETE AGGREGATES CONFORMING TO ASTM C33 FOR NORMAL -WEIGHT <br />CONCRETE. <br />F. WATER USED FOR MIXING CONCRETE SHALL BE POTABLE AND CONFORM TO ASTM C1602. <br />G. THE USE OF CALCIUM CHLORIDE, ADMIXTURES CONTAINING CHLORIDES AND OTHER <br />CHLORIDE CONTAINING AGENTS IN CAST -IN -PLACE STRUCTURAL CONCRETE IS PROHIBITED. <br />C. CAST -IN -PLACE CONCRETE <br />H. CONCRETE WITH AN EXPOSURE TO FREEZING AND THAWING OR DEICING CHEMICALS SHALL . ^*040 <br />HAVE AIR ENTRAINMENT PRODUCING A TOTAL AIR CONTENT OF 6 PERCENT +/-1.5 PERCENT a Na tl'GompM <br />BY VOLUME. AIR ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260. ENGINEERING#31348 <br />I. CONCRETE CLEAR COVER OVER REINFORCING SHALL BE IN ACCORDANCE WITH ACI 318, AS <br />LISTED BELOW, UNLESS NOTED OTHERWISE - <br />LOCATION <br />CLEAR COVER (IN.) <br />CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH <br />3 <br />EXPOSED TO EARTH OR WEATHER #6 AND LARGER <br />2 <br />EXPOSED TO EARTH OR WEATHER #5 AND SMALLER <br />1-1/2 <br />SLABS NOT EXPOSED TO WEATHER <br />3/4 <br />CONCRETE REINFORCING SHALL MEET THE FOLLOWING: <br />A. STEEL REINFORCING BARS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615 GRADE <br />60. STEEL REINFORCING BARS REQUIRED TO BE WELDED SHALL CONFORM TO THE <br />REQUIREMENTS OF ASTM A706 GRADE 60. WELDING OF STEEL REINFORCING BARS SHALL BE <br />IN ACCORDANCE WITH AWS D1.4-98 "STRUCTURAL WELDING CODE - REINFORCING STEEL". <br />WELDING OF REINFORCING OTHER THAN SPECIFIED IS PROHIBITED. STEEL REINFORCEMENT <br />SHOP DRAWINGS SHALL CLEARLY DENOTE ALL WELDING REQUIREMENTS FOR REVIEW AND <br />PRIOR APPROVAL. <br />B. ALL REINFORCING SHALL BE CONTINUOUS UNLESS NOTED OR INDICATED OTHERWISE. LAP <br />SPLICES AND EMBEDMENT LENGTHS FOR REINFORCING SHALL BE IN ACCORDANCE WITH THE <br />"REINFORCEMENT SPLICE AND EMBEDMENT SCHEDULE" AND THE "ACI STANDARD 90 AND 180 <br />DEGREE HOOK REINFORCEMENT EMBEDMENT SCHEDULE" SHOWN ON THE STRUCTURAL <br />DRAWINGS UNLESS NOTED OTHERWISE. WHERE REINFORCING BARS OF DIFFERENT SIZES <br />LAP, PROVIDE A LAP SPLICE LENGTH FOR THE LARGER REINFORCING BAR SIZE. <br />C. STEEL REINFORCEMENT SHOP DRAWINGS SHALL BE SUBMITTED WITH REINFORCING STEEL <br />DETAILED IN ACCORDANCE WITH ACI PUBLICATION SP-66 (04) "ACI DETAILING MANUAL - 2004". <br />D. ALL STEEL REINFORCEMENT SHOWN TO HAVE A 90 DEGREE LEG SHALL CONFORM TO THE <br />REQUIREMENTS OF A STANDARD ACI 90 DEGREE HOOK UNLESS NOTED OTHERWISE. <br />4. FORMING AND EMBEDMENTS SHALL MEET THE FOLLOWING: <br />A. ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED 3/4 INCH INSIDE FORMS OR <br />TOOLED TO 3/8 INCH RADIUS ON SLABS UNLESS NOTED OTHERWISE. <br />B. MAT FOUNDATION SLABS -ON -GRADE SHALL HAVE CONSTRUCTION JOINTS AND CONTROL <br />JOINTS (SAWED JOINTS) LOCATED AS SHOWN ON THE DRAWINGS. SHOULD THE <br />CONTRACTOR DESIRE TO DEVIATE FROM THE MAT FOUNDATION SLAB -ON -GRADE. JOINT <br />LAYOUT SHOWN, THE CONTRACTOR SHALL SUBMIT AN ALTERNATE JOINT LAYOUT AND <br />SPACING IN ACCORDANCE WITH THE RECOMMENDATIONS OF ACI 302.1 R "GUIDE FOR <br />CONCRETE FLOOR AND SLAB CONSTRUCTION", LATEST EDITION. THE CONTRACTOR SHALL <br />LOCATE AND DIMENSION ALL MAT FOUNDATION SLAB -ON -GRADE JOINTS ON THE STEEL <br />REINFORCEMENT SHOP DRAWINGS. <br />C. NO ALUMINUM SHALL BE EMBEDDED IN CONCRETE. CONDUITS AND PIPING RUNNING <br />HORIZONTALLY SHALL NOT BE EMBEDDED IN THE MAT SLAB FOUNDATION OR ELEVATED <br />CONCRETE SLABS ON STEEL DECK. VERTICAL PENETRATIONS THRU ELEVATED SLABS <br />REQUIRE PRIOR WRITTEN APPROVAL FROM THE FOR AND WHERE ALLOWED SHALL BE <br />COORDINATED NOT TO CONFLICT WITH REINFORCING AND SHALL BE LOCATED AND <br />DIMENSIONED ON THE STEEL REINFORCEMENT AND STEEL DECK SHOP DRAWINGS. VERTICAL <br />PENETRATIONS THRU ELEVATED SLABS SHALL BE SLEEVED OR FORMED ONLY. CORE. <br />DRILLING WILL NOT BE ALLOWED. ALL SLEEVED PENETRATIONS SHALL BE COORDINATED BY <br />THE CONTRACTOR AND LOCATED AND DIMENSIONED ON THE STEEL REINFORCEMENT AND <br />STEEL DECK SHOP DRAWINGS. THE NUMBER AND SPACING OF ADJACENT SLEEVES SHALL BE <br />COORDINATED WITH THE STRUCTURAL ENGINEER OF RECORD PRIOR TO INSTALLATION TO <br />PREVENT ANY IMPACT ON STRUCTURAL CAPACITY OR PERFORMANCE. <br />5. CURING FOR CONCRETE SURFACES NOT IN CONTACT WITH FORMS. ONE OF THE FOLLOWING <br />PROCEDURES SHALL BE APPLIED IMMEDIATELY AFTER COMPLETION OF PLACEMENT AND <br />FINISHING. ALL CONCRETE MAT FOUNDATION SLABS -ON -GRADE SHALL BE CURED USING <br />MOISTURE RETAINING MATERIAL INDICATED IN ITEM "A" BELOW. <br />A. APPLICATION OF MOISTURE RETAINING CURING MATERIALS CONSISTING OF BURLAP BACKED <br />WHITE WATERPROOF SHEET MATERIALS, CONFORMING TO ASTM C171 "STANDARD <br />SPECIFICATION FOR SHEET MATERIALS FOR CURING CONCRETE". CURING SHALL BE <br />CONTINUED AT LEAST 7 DAYS. <br />B. APPLICATION OF A CURING COMPOUND CONFORMING TO ASTM C309 "STANDARD <br />SPECIFICATION FOR LIQUID MEMBRANE FORMING COMPOUNDS FOR CURING CONCRETE". <br />THE COMPOUND SHALL BE APPLIED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE <br />MANUFACTURER IMMEDIATELY AFTER ANY WATER SHEEN WHICH MAY DEVELOP AFTER <br />FINISHING HAS DISAPPEARED FROM THE CONCRETE SURFACE. IT SHALL NOT BE USED ON <br />ANY SURFACE AGAINST WHICH ADDITIONAL CONCRETE OR SUBSEQUENTLY APPLIED FINISH <br />MATERIAL OF SYSTEM IS TO BE BONDED UNLESS IT IS PROVEN THAT THE CURING COMPOUND <br />WILL NOT PREVENT PROPER BOND, OR UNLESS POSITIVE MEASURES ARE TAKEN TO REMOVE <br />IT COMPLETELY FROM AREAS TO RECEIVE BONDED APPLICATIONS. CURING SHALL BE <br />CONTINUED AT LEAST 7 DAYS. <br />6. ALL EXTERIOR CONCRETE MAT FOUNDATION SLABS -ON -GRADE AND ELEVATED SLABS ON <br />STEEL DECK SHALL RECEIVE A STEEL TROWEL FINISH UNLESS NOTED OTHERWISE, <br />SPECIFIED, OR REQUIRED BY A SUBSEQUENT FLOOR FINISH SYSTEM OR MATERIAL. <br />��� J •"'�,� N $fir'" <br />Goo <br />STUART T`WEBB <br />STRUCTURAL ENGINEER <br />REG. NO.65469 <br />U <br />0 <br />rn <br />NQ <br />M <br />0 <br />O <br />�Z <br />0 <br />�a <br />z� <br />Oo <br />O <br />LL <br />m <br />ILo. <br />0 <br />0 <br />00 <br />U <br />N <br />� <br />w <br />� <br />¢ <br />N <br />0 <br />o <br />M <br />or)6 <br />�_ <br />u" <br />0 <br />z <br />= vi <br />mo <br />m <br />0 <br />m <br />m <br />U- <br />co <br />Ix <br />NJ <br />l <br />1m <br />M 5. <br />o- <br />J <br />N <br />U <br />w <br />z <br />O <br />z <br />o <br />m <br />Lu <br />0 <br />m <br />H <br />z <br />Z <br />z <br />J <br />�z <br />Oa <br />0 <br />~ <br />J <br />w <br />03 <br />Z <br />Z <br />Z <br />� <br />w <br />O <br />w <br />m <br />O <br />w <br />a <br />SHEET <br />IDENTIFICATION <br />S-ool <br />
The URL can be used to link to this page
Your browser does not support the video tag.