My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4330 20th St (41)
Zephyrhills
>
Building Department
>
Building Plans
>
4330 20th St (41)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 9:05:10 AM
Creation date
2/18/2025 3:18:56 PM
Metadata
Fields
Template:
Building Plans
Street #
4330
Location
20th St
Contractor
Ryman Construction
Building Plans - Permit #
14830
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LABORATORY EQUIPMENT LIST <br />Research Group: <br />Nestle Waters North America <br />Room Nmae <br />Analv6caland MicroLabs <br />Roe: Number: <br />Prepared hW, <br />Epstein <br />Date: <br />08.26.2013 <br />LOCATION: <br />PLUMB NG: <br />IMECHANICAL <br />B: Bench Mounted <br />F <br />Floor of Fume Hood <br />CW : Cold Water', <br />G. <br />NaturalGas <br />PCW. <br />'Process Cooling Water <br />C ICeilingMountod <br />Fume Hood <br />HW HotWater - <br />A: <br />Compressed Air._.... <br />S T M : <br />.Steam <br />F Floor Standing <br />m <br />rH <br />_..... <br />Tarminatic nofconnection <br />RGW ReagantGradaWater <br />V <br />Vacuum <br />EXHt <br />Ventilation <br />U. Undercounter <br />Plug load <br />WST Waste Drain <br />SG <br />Special Gas <br />PE <br />PointExhaust <br />W: WaIIMounted <br />Hard Wire <br />IN2,He,etc.l <br />NITROGEN CYLINDER <br />DIONEXEQUIPMENT <br />CHEMICALEXHAUST D <br />HOOLAMINAS <br />FLOW HOOD <br />Nualle NU-301-530 <br />�■ <br />r R <br />LARGE r©®®�_____®�_-_--__--_--____— <br />- <br />LARGEM <br />SMALLFREEZER <br />Marvel Scientific <br />S tacked <br />r -VWn <br />1565 <br />Stacked <br />INCUBATORS #5 <br />GC to furnish and installbased onowner selected <br />7 EQUIPMENT SCHEDULE <br />DOOR SCHEDULE <br />ROOM NAME <br />DOOR Nc. <br />DOOR TYPE <br />DOOR DIMENSIONS <br />DOOR MATERIALS <br />LABEL <br />HRWR <br />DETAILS <br />FINIS.. <br />REMARKS <br />tN x H <br />THK <br />OOR <br />FIRMSET <br />M'CRO LAB <br />218 <br />A <br />3'-0" X T-0" <br />1 3/4" <br />HOLLO''W METAL <br />^M <br />- <br />i <br />F-1 <br />CARD READER <br />ANALYTICAL LAB <br />219A <br />A <br />3'-0" X 7'-O" <br />1 3/4"-OLLOJ`/ <br />METAL <br />"M <br />- <br />1 <br />P-1 <br />CARD READER <br />ANALYTICAL LAB <br />219E <br />A <br />3'-C" X 7'-0" <br />1 3/4" <br />HOLLO?Rr METAL <br />-,M <br />- <br />i <br />P-1 <br />CARD READER <br />ANALYTICAL LAB <br />219C <br />A <br />3'-0" X 7'-O" <br />1 3; 4" <br />=0LL0'v?t METAL <br />M <br />- <br />1 <br />P-1 <br />CARD READER <br />HARDWARE SCHEDULE <br />FINISH HARDWARE MATERIAL SHALL MATCH THE EXISTING BUILDING <br />STANDARD. <br />HARDWARE SET 1 LABS <br />STORLROOM FUNCTION LOCKSLT LLVLR DEVICE <br />BUTT HINGES <br />ELECTRIC STRIKE, FAIL SAFE <br />DOOR. SILENCERS <br />WALL STOP <br />CLOSER <br />CARD RLADER <br />34" HIGH STAINIESS STEEL KICKPLATE — BOTH SIDES OF DOOR <br />6 I SDOTOR AND HARDWARE SCHEDULES <br />DOOR SCHEDULE NOTES <br />9. <br />ALL DOORS CONTROLLED BY CARD READERS ON THE <br />1. <br />LOCKSETS, LEVER DEVICES AND FINISH HARDWARE <br />EMERGENCY EGRESS PATH SHALL HAVE A FAIL SAFE <br />SHALL MATCH OWNER STANDARD. ALL NEW CARD <br />LOCKING DEVICE AND SHALL AUTOMATICALLY UNLOCK <br />READERS SHALL MATCH THE EXISTING ACCESS CONTROL <br />UNDER THE FOLLOWING CONDITIONS: <br />SYSTEM <br />9.1. <br />LOSS OF POWER TO BUILDING OR DEVICE <br />9.2• <br />MALFUNCTION OF ACCESS CONTROL SYSTEM OR <br />2. <br />ALL NEW OR ALTERED DOORS TO HAVE <br />DEVICE <br />LEVER —OPERATED HARDWARE, AS SCHEDULED. ALL <br />9.3. <br />ACTIVATION OF BUILDING FIRE ALARM SYSTEM <br />DOORS MUST HAVE 32" MIN. CLEAR OPENING <br />9.4. <br />ACTIVATION OF SMOKE DETECTION SYSTEM <br />MEASURED FROM THE FACE OF THE DOOR WHEN IT IS <br />9.5. <br />BY REMOTE COMMAND FROM CENTRAL CONTROL <br />OPENED 90 DEG TO THE DOOR STOP. <br />POINT IN BUILDING <br />3. <br />PROVIDE HOLLOW METAL FRAMES, WRAPAROUND TYPE <br />10. <br />ALL DOORS AND HARDWARE TO CONFORM WITH LOCAL <br />WITH ADJUSTABLE JAMB ANCHORS. PROVIDE UL RATED <br />BUILDING CODES, FLORIDA ACCESSIBILITY CODE AND <br />JAMB ANCHORS AT ALL LABEL DOOR INSTALLATIONS. <br />FEDERAL ADA REGULATIONS. <br />ALL FRAMES TO BE CLASS "C" 45 MINUTE FIRE RATED, <br />U.N.O. <br />11. <br />EGRESS DOORS SHALL BE READILY OPERABLE FROM <br />EGRESS SIDE WITHOUT THE USE OF KEY OR SPECIAL <br />4. <br />ALL DOOR CLOSERS TO BE LOCATED ON ROOM <br />KNOWLEDGE. <br />INTERIOR SIDE OF DOOR OPENING, U.N.O. USE <br />PARALLEL ARM TYPE U.N.O. <br />12. <br />PROVIDE KNURLED SURFACE ON ENTRY SIDE OF <br />HARDWARE, AS TACTILE WARNING, FOR ALL DOORS TO <br />5. <br />KEYING REQUIREMENTS SHALL BE COORDINATED WITH <br />STORAGE ROOMS AND ANY OTHER ROOMS THAT MIGHT <br />THE OWNER'S REPRESENTATIVE. <br />CONTAIN HAZARDOUS OBJECTS OR MATERIALS. <br />6. <br />ALL DOOR CLOSERS SHALL MEET THE ACCESSIBILITY <br />CRITERIA ON ANSI A117 AND LOCAL BUILDING CODES <br />FOR MAXIMUM OPENING FORCE. <br />7. <br />ALL GLAZING FOR DOOR LTTES AT LABELED DOORS <br />SHALL BE X" INCH THICK FIRE RATED WIRE GLASS <br />U.N.O., TO MATCH EXISTING DOORS. <br />8. <br />GC TO COORDINATE ALL LOCKING AND CARD READER <br />REQUIREMENTS WITH OWNER REQUIREMENTS. <br />DOOR TYPES <br />A <br />1,q DOOR STYLE, MATERIAL <br />AND SIZE TO MATCH <br />BUILDING STANDARD <br />SCHEDULED HARDWARE <br />O <br />O <br />\ t7 <br />\ W <br />W <br />N <br />4 DOOR ELEVATIONS <br />SCALE: NTS <br />EXISTING 8" CMU WALL <br />VERIFY DIMS IN FIELD <br />FILL WITH GROUT <br />co <br />HINGE SIDE <br />ANCHORS --/ <br />NEW FURRED WALL SEALANT BOTH <br />PARTITION TYPE B. SIDES 5/8" <br />HOLLOW MEI`AL:�// <br />DOOR FRAME <br />PROVIDE U.L APPROVED ANCHORS <br />WHERE REQUIRED <br />5 JAMB IN CMU <br />SCHEDULED PARTITION <br />2" <br />� ,� JAMB ANCHOR — ADJUSTABLE <br />HOLLOW METAL FRAME (AT FIRE RATED PARTITIONS) <br />NOTE: AT FIRE RATED PARTITIONS USE UL <br />RATED ADJUSTABLE JAMB ANCHORS AND UL <br />LABELED HOLLOW METAL DOOR FRAMES <br />3 HEAD/JAMB IN GYP <br />SCALE: 1-1/2" =1'-0' <br />FINISH SCHEDULE <br />CEILINGS <br />TYPE <br />DESCRIPTION <br />MANUF. <br />SERIES/ STYLE <br />SIZE <br />LOCATION <br />REMARKS <br />sL.T— e <br />ACOUS'i E_.Pd.G LE <br />ANDwj SYSTEM <br />ARM',' -RCN,' VP <br />E HL <br />CLLAPv ROOM -L _+': kS .,E�. I L xY':'TH kS; tE'> <br />CLEAN ROOM �Eiu <br />=1' x x 3'4" vEILPvV <br />T LE <br />FLOOR <br />TYPE <br />DESCRIPTION <br />MANUF. <br />SERIES/ STYLE <br />COLOR NAME & NUMBER <br />SIZE <br />LOCATION <br />REMARKS <br />YF—? <br />RE N L-S FL33R,'NG <br />REPDX'r M:lR7AR Y ...M' <br />SIO HARD CAR <br />;_'QLAL <br />S CLAC S <br />IONE <br />TH V '-OAT <br />S4 <br />PErsTEF <br />_ <br />b 4 HICK R'U''.i'ELED <br />LABS <br />BASE <br />TYPE <br />DESCRIPTION <br />MANUF. <br />COLOR NAME & NUMBER <br />SIZE <br />LOCATION <br />REMARKS <br />RUBBER <br />OR <br />t?hh;SvPvt--= OREASE <br />EQUA <br />«38 Ei°JT=; Co <br />4"N ROLLED GOODS <br />ALL '+'s•`kLLS AND CASE C46iNETS <br />COVE BASE <br />WALL <br />TYPE <br />DESCRIPTION <br />MANUF. <br />COLOR NAME/NUMBER <br />GENERAL COLOR/ FINISH <br />LOCATION <br />REMARKS <br />—: <br />t.. U3;:,,E:,.vr;r <br />3_N AMi MOOPE <br />Si E? SRE idtE i _ TEY aylt - -Bs)X` <br />H <br />SEMI 3 S., <br />LABS <br />MISC. <br />TYPE <br />DESCRIPTION <br />MANUF. NAME <br />COLOR/STYLE <br />LOCATION <br />REMARKS <br />k`:7—` <br />�ti i°it.i.)'4,,+ _., MEN'sS <br />!.1EU.HOS!�;:GE <br />CLr.�SI;^ A4E=4�:�;5 RJLLE>"—Slir:DE :;TS7Ef.t <br />7HERMOVE L 1300 SERIES <br />nAS}E '.4E.":`�t — SIL�iEt`� <br />;a 13tg <br />iv_.`d EXtt2ti? '','tr,P.i.Udr'S <br />It�CNUAL t�?_P.ATtC�f� <br />2 FINISH SCHEDULE <br />SCALE: <br />FINISH PLAN <br />1 SCALE: 1/8' =1'-0' <br />MEP / FP Engineer <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />Design Architect <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />FINISH PLAN NOTES <br />1. ALL INTERIOR WALL, CEILING FINISHES, FLOOR <br />COVERINGS AND TRIM TO COMPLY WITH 2O10 FBC. <br />2. PAINT SCHEDULE INDICATES COLOR AND GENERAL FINISH <br />ONLY. CONTRACTOR TO USE APPROPRIATE FINISHING <br />SYSTEM FOR EACH SUBSTRATE AS NEEDED. <br />3. HOLLOW METAL FRAMES AND DOORS TO BE PAINTED <br />WITH A SEMI —GLOSS FINISH TO MATCH ADJACENT WALL <br />FINISH. <br />4. FLOORS WHERE EXISTING MATERIAL HAS BEEN REMOVED <br />SHALL BE PATCHED, LEVELED AND PREPARED AS <br />REQUIRED TO ACCEPT NEW FLOORING MATERIAL <br />5. REFER TO SHEET A-801 FOR FLOORING TRANSITION <br />DETAILS. <br />6. ALL WALLS TO PAINTED P-1, UNLESS NOTED <br />OTHERWISE ON PLAN. <br />Nestle Waters North America <br />Nestle Waters North America <br />4330 20th Street <br />Zephyrhills, Florida 33542-6703 <br />972.462.3663 <br />KEY NOTES <br />1 PROVIDE MECHOSHADE WINDOW TREATMENTS AT <br />ALL NEW EXTERIOR WINDOWS. SEE FINISH <br />SCHEDULE FOR MORE INFORMATION. <br />ORUBBER BASE RB-1 TO BE INSTALLED AT BASE <br />CABINETRY AND AT WALLS. <br />4 <br />3 <br />09.18.2013 <br />09.11.2013 <br />ISSUE FOR PERMIT <br />ISSUE FOR BIDS <br />2 <br />1 <br />NO. <br />09.03.2013 <br />08.16.2013 <br />DATE <br />CD REVIEW PACKAGE <br />DID REVIEW PACKAGE <br />REVISIONS/ISSUANCES <br />..aowkPSTEIN <br />Architecture <br />Chicago <br />Interiors <br />New York <br />Engineering <br />Bucharest <br />Construction <br />Warsaw <br />600 W. Fulton Street <br />Chicago, IL 60661-1259 <br />T 312.454.9100 <br />www.epsteinglobal.com <br />PROJECT NUMBER: <br />12386 <br />PROJECT MANAGER: <br />JK <br />ARCH/ENG: <br />LK <br />SCALE: <br />9 <br />1/8" = 11-01 <br />DRAWN BY: <br />JK <br />CHECKED BY: <br />LK <br />FINISH PLAN AND <br />SCHEDULES <br />vv <br />SEAL <br />A-201 <br />A. Epstein and Sons International, Inc. Ali rights reserved. <br />
The URL can be used to link to this page
Your browser does not support the video tag.