POWER AND COMMUNICATION NOTES <br />1. <br />WHERE THE ARCHITECTURAL POWER AND COMMUNICATION <br />DRAWINGS INDICATE ITEMS SPECIFIED IN THE PROJECT <br />ENGINEERING DOCUMENTS, THIS INFORMATION IS <br />INCLUDED FOR THE PURPOSES OF COORDINATION AND <br />LOCATION, ONLY. <br />2. <br />EXPOSED ELECTRICAL, BUILDING CONTROL AND <br />COMMUNICATION DEVICES, INCLUDING LIGHTING FIXTURES, <br />RECEPTACLES, SWITCHES, THERMOSTATS, FIRE ALARM <br />A/V DEVICES AND TELEPHONES, SHALL BE LOCATED AS <br />INDICATED ON THE ARCHITECTURAL DRAWINGS. <br />3. <br />SEE THE PROJECT ENGINEERING DOCUMENTS FOR <br />MATERIAL AND INSTALLATION SPECIFICATIONS FOR THESE <br />ITEMS <br />4. <br />ALL OPERABLE DEVICES SHALL BE LOCATED AT <br />ACCESSIBLE HEIGHTS, AS SHOWN ON THE <br />ARCHITECTURAL STANDARDS ELEVATIONS. <br />5. <br />COORDINATE LOCATION OF ELECTRICAL OUTLETS WITH <br />EQUIPMENT REQUIREMENTS AND MILLWORK ELEVATIONS. <br />6. <br />ARCHITECT TO APPROVE ALL T-STAT AND FIRE PROBE <br />LOCATIONS PRIOR TO INSTALLATION. <br />7. <br />ALL POWER AND COMMUNICATIONS RECEPTACLES SHALL <br />BE ORIENTED HORIZONTALLY. <br />8. <br />LAB CABINETRY IS SHOWN FOR REFERENCE ONLY - <br />CABINETRY TO BE COORDINATED WITH OWNERS VENDOR. <br />GC TO COORDINATE WITH OWNER ANY WORK TO BE <br />DONE ON COORDINATION BETWEEN CABINET VENDOR <br />INSTALLATION, ELECTRICAL WORK AND EQUIPMENT <br />INSTALLATION. <br />GENERAL EQUIPMENT NOTES <br />1. <br />COORDINATE EXACT LOCATION, TERMINATIONS, MOUNTING <br />HEIGHTS AND ELECTRICAL CHARACTERISTICS FOR EACH <br />SPECIFIC MODEL AND PIECE OF EQUIPMENT WITH <br />OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER <br />PRIOR TO INSTALLATION. PROVIDE ELECTRICAL SERVICE <br />AS REQUIRED FOR EACH PIECE OF EQUIPMENT. ALL <br />RECEPTACLES SHALL BE OF VOLTAGE RATING AND <br />AMPACITY TO MATCH MANUFACTURER'S <br />RECOMMENDATIONS. INCLUDE ALL COSTS IN BASE BID <br />PROPOSAL <br />2. <br />REFER TO SHEET A-201 FOR EQUIPMENT SCHEDULE. <br />KEY NOTES <br />NEW CARD READER SYSTEM AT THIS <br />OINSTALL <br />LOCATION AND COORDINATE WITH NEW DOOR, <br />FRAME AND HARDWARE. COORDINATE <br />INSTALLATION OF CARD READER WITH EXISTING <br />SECURITY SYSTEM. <br />HEIGHT OF POWER, TELEPHONE AND <br />OCOORDINATE <br />DATA RECEPTACLE DEVICES WITH NEW LAB <br />CABINETRY, COUNTERTOP AND BACKSPLASH. ALL <br />POWER OUTLETS WITHIN 6' OF WATER MUST BE <br />A GFI RECEPTACLE. <br />COORDINATE HEIGHT OF POWER. TELEPHONE AND <br />3 <br />DATA RECEPTACLE DEVICES WITH EXISTING LAB <br />EQUIPMENT. <br />4 <br />AT ISLAND CABINETRY, GC TO PROVIDE AND <br />INSTALL A POWER POLE FROM THE CEILING TO <br />TOP OF COUNTERTOP WITH ELECTRICAL OUTLETS <br />CONTAINED WITHIN POLE JUST ABOVE COUNTER. <br />OF EXISTING ALARM STROBES TIED TO <br />OLOCATION <br />THE WATER PROCESSING PLC. STROBES TO <br />REMAIN IN CURRENT LOCATION. <br />OPROVIDE <br />J-BOX IN WALL FOR DISHWASHER <br />HOOK-UP. <br />EXISTING CARD READER SYSTEM AT THIS <br />OREUSE <br />LOCATION AND COORDINATE WITH NEW DOOR, <br />FRAME AND HARDWARE. <br />8 <br />REUSE EXISTING CARD READERS ON BOTH SIDES <br />OF DOOR AND EMERGENCY DOOR RELEASE AT <br />THIS LOCATION. COORDINATE WITH NEW DOOR, <br />FRAME AND HARDWARE. <br />POWER & COMMUNICATION SYMBOLS <br />ELECTRICAL DUPLEX RECEPTACLE <br />® <br />ELECTRICAL QUAD RECEPTACLE <br />JUNCTION BOX <br />TELE/DATA PORT RECEPTACLE <br />© <br />POWER POLE <br />QS <br />ALARM STROBE DEVICE - CEILING MOUNTED <br />CR <br />CARD READER DEVICE <br />LIGHT SWITCH <br />044" <br />HEIGHT DESIGNATION ABOVE FINISHED FLOOR <br />AFF <br />FOR MOUNTING DEVICE <br />1*1 <br />0 <br />Col <br />4 I SPO,WER & COMMUNICATIONS PLAN 2 SPACALE:,RTITION PLAN <br />CALE: <br />REFLECTED CEILING PLAN NOTES <br />1. REFER TO MECHANICAL AND FIRE PROTECTION ENGINEERING <br />DRAWINGS FOR SCOPE OF WORK. <br />2. SUBMIT ALL FIXTURE SAMPLES AND PRODUCT <br />INFORMATION TO ARCHITECT FOR APPROVAL PRIOR TO <br />COMMENCEMENT OF WORK. <br />3. LIGHT FIXTURES ARE SHOWN FOR REFERENCE ONLY. <br />SEE ELECTRICAL DRAWINGS FOR LIGHTING FIXTURE <br />SPECIFICATIONS AND FOR ADDITIONAL LIGHTING <br />FIXTURES, INCLUDING EXIT SIGNS, EMERGENCY LIGHTING, <br />DISPLAY LIGHTING AND CABINET DISPLAY LIGHTING. <br />4. ALL BLOCKING TO BE FIRE RETARDANT TREATED, U.N.O. <br />5. ALL LIGHT SWITCHES SHALL BE GANGED TOGETHER IN A <br />SINGLE FACEPLATE. G.C. TO COORDINATE ALL WALL <br />MOUNTED DEVICES ARE GANGED IN AN ORGANIZED MANNER. <br />REFER TO MOUNTING DIAGRAM ON SHEET CA-001. <br />6. REFER TO FINISH SCHEDULE A-201 FOR ADDITIONAL <br />CEILING SCOPE OF WORK. <br />7. ALL HVAC GRILLS, DIFFUSERS, SPRINKLER HEADS, STROBES <br />AND OTHER CEILING MOUNTED DEVICES SHALL BE <br />CENTER® IN ACOUSTICAL CEILING TILES, U.O.N. <br />KEY NOTES <br />OCENTER CEILING GRID IN ROOM AS SHOWN TO <br />ACCOMMODATE LIGHTING LAYOUT INDICATED ON <br />THE DRAWINGS. <br />OLOCATION OF EXHAUST FOR CHEMICAL HOOD. <br />REFER TO MECHANICAL ENGINEERING DRAWINGS <br />FOR MORE INFORMATION. <br />OLOCATION OF EXHAUST HOOD OVER AUTOCLAVE. <br />REFER TO MECHANICAL ENGINEERING DRAWINGS <br />FOR MORE INFORMATION. <br />RCP SYMBOLS <br />F1 2' X 2' RECESSED, T5 FLUORESCENT LIGHT <br />FIXTURE <br />o� <br />3 I SREFLECTED CEILING PLAN 11 I SDEMOLITION PLAN <br />MEP / FP Engineer <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />GENERAL NOTES <br />1. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. IN THE <br />EVENT THAT DISCREPANCIES ARE NOTED BETWEEN THE <br />SITE CONDITIONS AND THE PROJECT DOCUMENTS, THE <br />OWNER'S REPRESENTATIVE SHALL BE NOTIFIED <br />IMMEDIATELY. <br />2. ALL NEW PARTITIONS TO BE TYPE "A' UNLESS NOTED <br />OTHERWISE. ALL EXISTING CONCRETE BLOCK WALLS SHALL <br />BE TYPE "B". SEE PARTITION TYPES ON SHEET A-801. <br />3. DOOR INSTALLATIONS ARE DESIGNATED 000 <br />SEE SHEET A-201 FOR DOOR SCHEDULE FO. <br />4. ALL WORK IS TO BE DONE IN ACCORDANCE WITH LOCAL <br />BUILDING CODES AND ALL OTHER CODES WHICH MAY <br />HAVE AUTHORITY OVER THIS PROJECT. PROVIDE ALL <br />NECESSARY SAFEGUARDS, BARRIERS, TEMPORARY POWER, <br />LIGHTING, FIRE PROTECTION, ETC., AS REQUIRED DURING <br />DEMOLITION AND CONSTRUCTION. <br />5. ALL WOOD MATERIALS, INCLUDING FRAMING, BLOCKING, <br />AND PLYWOOD, SHALL BE FIRE RETARDANT TREATED,U.N.O. <br />6. ALL FIRE RATED CONSTRUCTION AND SMOKE PARTITIONS <br />SHALL BE FULLY SEALED TO THE STRUCTURE ABOVE. ALL <br />PENETRATIONS IN FIRE RATED CONSTRUCTION AND SMOKE <br />PARTITIONS SHALL BE FULLY FIRESTOPPED. <br />7. PARTITION REINFORCING/BLOCKING SHALL BE PROVIDED AT <br />ALL LOCATIONS WHERE WALL MOUNTED MILLWORK, <br />FURNITURE, EQUIPMENT, GRAB BARS, CLOSET RODS AND <br />ACCESSORIES ARE SHOWN ON THE PROJECT DRAWINGS. <br />8. ALL PARTITIONS THAT EXTEND FROM EXISTING PARTITIONS <br />SHALL MATCH AND ALIGN WITH THE EXISTING <br />CONSTRUCTION. <br />9. ALL EXISTING FLOOR SLABS TO RECEIVE NEW FLOOR <br />FINISHES SHALL BE PATCHED, REPAIRED, LEVELED AND <br />PREPARED AS REQUIRED TO RECEIVE NEW SPECIFIED <br />FLOORING MATERIAL <br />10. MAXIMUM TRANSITION HEIGHT FROM EXISTING THRESHOLDS <br />TO NEW FLOORING NOT TO EXCEED 1/2" (TYP.). <br />11. COORDINATE ALL REQUIRED GYP. BD. CONTROL JOINT <br />LOCATIONS WITH ARCHITECT. <br />12. GC TO VERIFY ALL EXISTING WALLS EXTEND FROM FLOOR <br />TO DECK AND ALL PENETRATIONS ARE PROPERLY SEALED. <br />ALL NEW PARTITIONS MUST ALSO GO TO DECK AND HAVE <br />PROPERLY SEALED PENETRATIONS TO ENSURE POSITIVE <br />PRESSURE AND HUMIDITY LEVELS ARE MAINTAINED <br />BETWEEN LAB AND SURROUNDING SPACES. <br />GENERAL PLAN DEMOLITION NOTES <br />1. ALL ITEMS SHOWN DASHED TO BE DEMOLISHED. REFER TO <br />ENGINEERING DRAWINGS FOR ADDITIONAL DEMOLITION <br />INFORMATION ON OTHER BASE BUILDING SYSTEMS AND <br />STRUCTURAL COMPONENTS. <br />2. ALL WORK IS TO BE DONE IN ACCORDANCE WITH LOCAL <br />BUILDING CODES AND ALL OTHER CODES WHICH MAY HAVE <br />AUTHORITY OVER THIS PROJECT. PROVIDE ALL NECESSARY <br />SAFEGUARDS, BARRIERS, TEMPORARY POWER, LIGHTING, <br />FIRE PROTECTION, ETC., AS REQUIRED DURING DEMOLITION. <br />3. CONTRACTORS SHALL FIELD SURVEY SITE OF PROPOSED <br />WORK TO DETERMINE THE EXTENT AND NATURE OF <br />DEMOLITION WORK. <br />4. WHERE EXISTING PARTITIONS ARE TO REMAIN (ADJACENT <br />TO DEMOLITION OR NEW WORK), CONTRACTOR IS TO <br />REMOVE ALL FINISH MATERIALS, PATCH AS REQUIRED TO <br />MAKE AS NEW, AS OUTLINED IN THE CONTRACT <br />DOCUMENTS. <br />5. REMOVE ALL CONSTRUCTION SHOWN ON THE DRAWINGS AS <br />"DEMOLISHED" INCLUDING, BUT NOT LIMITED TO FLOORING, <br />PARTITIONS, CEILINGS AND ELEMENTS OCCURRING ABOVE <br />FINISHED CEILING, HANGERS, STRAPS, AND OTHER <br />ACCESSORY OBJECTS CONNECTED WITH DEMOLITION. <br />6. REMOVE BUILT-IN CABINET WORK ONLY FROM WALLS <br />SHOWN TO BE DEMOLISHED, UNLESS NOTED OTHERWISE. <br />7. WHERE PARTITIONS ARE BEING REMOVED, ALL ELECTRICAL <br />OUTLETS & SWITCHES SHALL BE DISCONNECTED AT <br />DISTRIBUTION PANELS & ALL WIRE REMOVED FROM <br />CONDUIT. <br />8. REMOVE ALL LOW VOLTAGE OR SIGNAL CABLES AND <br />CONNECTORS NO LONGER REQUIRED FOR THE OPERATION <br />OF THE OWNER'S TELEPHONE, DATA OR OTHER SYSTEMS. <br />9. REMOVE ALL FINISHES AND WALL BASES. PREP WALLS <br />AND FLOORS AS REQUIRED FOR NEW FINISHES. <br />10. COORDINATE WITH OWNER THE CAREFUL RELOCATION OF <br />VARIOUS LARGE PIECES OF EXISTING LAB EQUIPMENT. SEE <br />EQUIPMENT SCHEDULE FOR LIST OF EXISTING EQUIPMENT <br />TO BE REUSED. <br />11. ALL EXISTING PARTITIONS TO REMAIN SHALL HAVE ALL <br />CLIPS/BRACKETS/HANGERS/ETC. REMOVED FROM SURFACE. <br />ALL REMAINING WALLS SHALL BE PROPERLY <br />PATCHED/REPAIRED FOR RECEIPT OF NEW SPECIFIED <br />FINISH. <br />Design Architect <br />Nestle Waters North America <br />EPSTEIN <br />Nestle Waters North America <br />600 West Fulton <br />4330 20th Street <br />Chicago, IL 60661 <br />Zephyrhills, Florida 33542-6703 <br />312.454.9100 <br />972.462.3663 <br />KEY NOTES <br />ONEW EXTERIOR WINDOWS TO BE INSTALLED PER <br />LOCAL BUILDING CODE TO MATCH EXISTING <br />ADJACENT WINDOWS. CONTRACTOR TO VERIFY <br />EXISTING WINDOW TYPE AND SUBMIT NEW <br />WINDOW SPECIFICATIONS TO OWNER AND <br />ARCHITECT FOR REVIEW. <br />OINSTALL NEW PAINTED WINDOW SILLS AND <br />INTERIOR DRYWALL AS NEEDED AT EXTERIOR <br />WALL. <br />3 LAB CABINETRY AND COUNTERTOP TO BE <br />SUPPLIED AND INSTALLED BY OWNERS VENDOR <br />GC TO PROVIDE IN -WALL BLOCKING FOR ALL <br />UPPER CABINETRY. <br />OCONTRACTOR TO COORDINATE RE -LOCATION OF <br />EXISTING LAB EQUIPMENT WITH OWNER. <br />PROVIDE NEW DOOR, FRAME AND HARDWARE. <br />OCOORDINATE WITH CARD READER INSTALLATION. <br />REFER TO DOOR SCHEDULE FOR MORE <br />INFORMATION. <br />OLOCATION OF NEW EMERGENCY EYEWASH/SPRAY <br />HOSE UNIT. REFER TO PLUMBING ENGINEERING <br />DRAWINGS FOR MORE INFORMATION. <br />OPROVIDE ROUGH -IN PLUMBING BELOW SINK FOR <br />DISHWASHER HOOK-UP. REFER TO PLUMBING <br />ENGINEERING DRAWINGS FOR MORE INFORMATION. <br />OLOCATION OF REINSTALLED TIMECLOCK. <br />COORDINATE LOCATION WITH OWNER AND <br />ELECTRICAL OUTLET. <br />NORTH <br />(T <br />GENERAL RCP DEMOLITION NOTES <br />1. ALL CEILING ELEMENTS INCLUDING, BUT NOT LIMITED TO <br />GRID, TILE, LIGHTING, MECH. GRILLS AND ELEMENTS <br />OCCURING ABOVE FINISHED CEILING, SUCH AS HANGERS, <br />STRAPS AND OTHER ACCESSORY OBJECTS CONNECTED <br />WITH THE CEILING ARE TO BE DEMOLISHED. REFER TO <br />ENGINEERING DRAWINGS FOR ADDITIONAL DEMOLITION <br />INFORMATION. <br />2. ALL WORK IS TO BE DONE IN ACCORDANCE WITH LOCAL <br />BUILDING CODES AND ALL OTHER CODES WHICH MAY <br />HAVE AUTHORITY OVER THIS PROJECT. PROVIDE ALL <br />NECESSARY SAFEGUARDS, BARRIERS, TEMPORARY <br />POWER, LIGHTING, FIRE PROTECTION, ETC., AS REQUIRED <br />DURING DEMOLITION. <br />3. CONTRACTORS SHALL FIELD SURVEY SITE OF PROPOSED <br />WORK TO DETERMINE THE EXTENT AND NATURE OF <br />DEMOLITION WORK. <br />KEY NOTES <br />1 REMOVE EXISTING EXTERIOR WINDOWS, SILLS AND <br />INTERIOR DRYWALL AS REQUIRED. PREPARE <br />OPENINGS FOR REPLACEMENT WINDOWS. <br />OCOORDINATE WITH OWNER ANY EXISTING LAB <br />EQUIPMENT TO BE RELOCATED TO TEMPORARY <br />LAB LOCATION. <br />OREMOVE EXISTING DOOR, FRAME AND HARDWARE. <br />OREMOVE EXISTING LAB CABINETRY AND <br />4 COUNTERTOPS, INCLUDING SINKS, AND CAP <br />PLUMBING AT SOURCE. <br />OREMOVE EXISTING DOOR, FRAME, HARDWARE AND <br />CARD READER SYSTEM. <br />OREMOVE EXISTING TIMECLOCK AND RETURN TO <br />OWNER FOR REINSTALLATION. <br />OLOCATION OF EXISTING ALARM STROBES TIED TO <br />THE WATER PROCESSING PLC. STROBES TO <br />REMAIN IN CURRENT LOCATION. PROTECT DURING <br />DEMOLITION PHASE. <br />8 DURING DEMOLITION, CONTRACTOR TO <br />COORDINATE MOLD REMEDIATION SCOPE OF <br />WORK WITH QUALIFIED ENVIRONMENTAL <br />CONSULTANT. <br />4 <br />3 <br />09.18.2013 <br />09.11.2013 <br />ISSUE FOR PERMIT <br />ISSUE FOR BIDS <br />2 <br />09.03.2013 <br />CD REVIEW PACKAGE <br />1 <br />NO. <br />08.16.2013 <br />DATE <br />DD REVIEW PACKAGE <br />REVISIONS/ISSUANCES <br />PSTEIN <br />Architecture <br />Chicago <br />Interiors <br />New York <br />Engineering <br />Bucharest <br />Construction <br />Warsaw <br />600 W. Fulton Street <br />Chicago, IL 60661-1259 <br />T 312.454.9100 <br />www.epsteinglobal.com <br />PROJECT NUMBER: 12386 <br />PROJECT MANAGER: JK <br />ARCH/ENG: LK <br />SCALE: 1/8" = 1'-0" <br />DRAWN BY: JK <br />CHECKED BY: LK <br />DEMOLITION, PARTITION, <br />REFLECTED CEILING AND <br />POWER & COMM. PLANS <br />A-1 01 <br />©)=X A. Epstein and Sons Intem tonal, Inc. AH rights reserved <br />