Laserfiche WebLink
ELECTRICAL PANEL <br />TO BE RELOCATED <br />WINDOW TO BE <br />REPLACED IN KIND <br />CONVERT <br />LAUNDRY IN <br />NEW BATHROOM <br />& LAUNDRY <br />LAUNDRY <br />CARPORT TO BE <br />CONVERTED IN <br />NEW BEDROOM <br />CARPORT <br />------ ---------- <br />------------ --------------------- <br />_ <br />DOOR TO - <br />rilliz <br />REMAIN <br />WINDOW REMAIN <br />I <br />FLORIDA ROOM <br />i I CONVERSION TO <br />DINING ROOM <br />II II <br />FLORIDA <br />I I <br />'I ROOM <br />I I <br />I I <br />I I <br />WINDOW TO <br />BE REPLACED <br />IN KIND <br />BATH <br />WINDOW TO BE <br />I REPLACED IN KIND <br />5' <br />I III o �o REF. DOOR TO <br />III BE REMOVED <br />IIII <br />KITCHEN <br />* W-V <br />III WALL SECTION <br />III TO BE REMOVED <br />III REPAIR (1) <br />III PRE-ENGINEERED <br />WOOD ROOF TRUSS, <br />III AS PER DETAILS <br />IIII <br />IIII <br />IIII <br />IIII <br />IIII <br />IIII <br />SCOPE OF WORK: <br />LIVING <br />ROOM <br />WINDOW TO BE <br />REPLACED IN KIND <br />W%H <br />I s <br />J_ <br />WINDOW TO BE <br />REPLACED IN KIND <br />WINDOW TO BE <br />REPLACED IN KIND <br />WINDOW TO BE N11 <br />REPLACED I <br />DINING <br />ROOM <br />BATH <br />BEDROOM #2 <br />-------------- <br />II \ <br />II <br />WALL SECTION i <br />TO BE REMOVED <br />I <br />II � <br />II — <br />I <br />I <br />II <br />II <br />II <br />i <br />WINDOW TO BE <br />REPLACED I <br />1 <br />I I I <br />I I <br />--- BEDROOM #1 <br />OPEN / _ WINDOW TO BE <br />PORCH REPLACED IN KIND <br />EXISTING FLOOR PLAN <br />SCALE: 1 /4"=V-0" <br />PROJECT RELATED TO CODE CASE # 1965-2023 <br />1. CONVERSION OF EXISTING CARPORT AND LAUNDRY ROOM IN NEW <br />MASTER BEDROOM AND MASTER BATHROOM <br />2. CONVERSION OF EXISTING CONDITIONED FLORIDA ROOM IN NEW DINING <br />ROOM. <br />3. REMOVE INTERIOR PARTITION WALLS AS SHOWN <br />4. CONSTRUCTION OF NEW EXTERIOR (NON LOAD BEARING WALL) IN <br />CARPORT AREA. <br />5. RELOCATE EXISTING INTERIOR BATHROOM. <br />6. CONSTRUCTION OF NEW SHOWER IN EXISTING HALF BATH. <br />7. REPLACE ALL EXISTING WINDOWS EXCEPT FOR FLORIDA ROOM AREA. <br />8. REPLACE EXISTING DOOR AND INSTALL NEW DOORS. <br />9. REMOVE CERAMIC TILE AND INSTALL NEW VINYL OR CERAMIC FLOORING <br />10. REPLACE ALL ELECTRICAL FIXTURES, REWIRE ONLY FOR NEW AREA AND <br />NEW ELECTRICAL FIXTURES. <br />11. ELECTRICAL PANEL TO BE RELOCATED <br />12. INSTALL NEW PLUMBING FOR BATHROOMS, <br />13. REPLACE ALL PLUMBING FIXTURES. <br />14. AC UNIT TO BE REPLACED. <br />15. REPAIR DRYWALL HOLES AND INSTALL NEW DRYWALL IN NEW WALLS <br />AREA <br />16. PAINT ALL INTERIOR AND EXTERIOR WALLS <br />17. REPAIR ONE ROOF TRUSS AS PER DETAILS. <br />18. ROOFING REPLACED IN A SEPARATE PERMIT BGR-007033-2023. <br />19. INSTALL NEW R-13 INSULATION FOR NEW EXTERIOR WALLS. <br />20. INSTALL R-38 INSULATION IN ATTIC FOR NEW MASTER BEDROOM AREA. <br />21. CONTRACTOR/BUILDER TO VERIFY EXISTING INSULATION TO COMPLY WITH <br />2020 FBC—RESIDENTIAL. <br />22. NO EXCAVATIONS TO BE DONE <br />WALL LEGEND <br />8" BLOCK MASONRY WALL <br />® <br />8" BLOCK MASONRY WALL + 1 FACE FURRING' <br />4" INTERIOR PARTITION WALL <br />® <br />4" WOOD EXTERIOR WALL <br />NEW 4" WOOD EXTERIOR WALL <br />NEW 4" INTERIOR PARTITION WALL <br />WALL SECTION TO BE REMOVED <br />EXISTING FRONT ELEVATION <br />SCALE: 1/4 =V-0" <br />EXISTING LEFT ELEVATION <br />SCALE. 1/4 —1 -0 <br />EXISTING RIGHT ELEVATION <br />SCALE: 1 /4"= V-0" <br />SECTION R318 <br />PROTECTION AGAINST TERMITES <br />R318.1 Termite protection. <br />Termite protection shall be provided by registered termiticides, including soil applied pesticides, <br />baiting systems, and pesticides applied to wood, or other approved methods of termite <br />protection labeled for use as a preventative treatment to new construction. See Section 202, <br />"Registered termiticide." Upon completion of the application of the termite protective treatment, <br />a Certificate of Compliance shall be issued to the building department by the licensed pest <br />control company that contains the following statement: "The building has received a complete <br />treatment for the prevention of subterranean termites. Treatment is in accordance with rules <br />and laws established by the Florida Department of Agriculture and Consumer Services." <br />R318.1.1 <br />If soil treatment is used for subterranean termite prevention, the initial chemical soil <br />treatment inside the foundation perimeter shall be done after all excavation, backfilling and <br />compaction is complete. <br />R318.1.2 <br />If soil treatment is used for subterranean termite prevention, soil area disturbed after initial <br />chemical soil treatment shall be retreated with a Chemical soil treatment, including spaces <br />boxed or formed. <br />R318.1.3 <br />If soil treatment is used for subterranean termite prevention, space in concrete floors boxed <br />out or formed for the subsequent installation of plumbing traps, drains or any other purpose <br />shall be created by using plastic or metal permanently placed forms of sufficient depth to <br />eliminate any planned soil disturbance after initial chemical soil treatment. <br />R318.1.4 <br />If soil treatment is used for subterranean termite prevention, chemically treated soil shall be <br />protected with a minimum 6 mil vapor retarder to protect against rainfall dilution. If rainfall <br />occurs before vapor retarder placement, retreatment is required. Any work, including <br />placement of reinforcing steel, done after chemical treatment until the concrete floor is <br />poured, shall be done in such manner as to avoid penetrating or disturbing treated soil. <br />R318.1.5 <br />If soil treatment is used for subterranean termite prevention, concrete overpour <br />or mortar accumulated along the exterior foundation perimeter shall be removed <br />prior to exterior chemical soil treatment, to enhance vertical penetration of the <br />chemicals. <br />R318.1.6 <br />If soil treatment <br />is used for subterranean termite <br />prevention, chemical soil <br />treatments <br />shall <br />also be applied under all exterior concrete or grade within 1 <br />foot (305 <br />mm) <br />of the primary structure sidewalls. <br />Also, a vertical chemical <br />barrier shall <br />be applied <br />promptly after construction is <br />completed, including initial <br />landscaping <br />and <br />irrigation/sprinkler installation. Any <br />soil disturbed after the <br />chemical vertical <br />barrier is applied shall be promptly <br />retreated. <br />R318.1.7 <br />If a registered termiticide formulated and registered as a bait system is used <br />for subterranean termite prevention, Sections R318.1.1 through R318.1.6 do not <br />apply; however, a signed contract assuring the installation, maintenance and <br />monitoring of the baiting system that is in compliance with the requirements of <br />Chapter 482, Florida Statutes shall be provided to the building official prior to <br />the pouring of the slab, and the system must be installed prior to final <br />building approval. <br />If the baiting system directions for use require a monitoring phase prior to <br />installation of the pesticide active ingredient, the installation of the monitoring <br />phase components shall be deemed to constitute installation of the system. <br />R E V I S 1 0 N S <br />No DATE <br />A <br />E-O7 <br />nut <br />JW <br />woF <br />Xx <br />I� <br />O� <br />w <br />� <br />O <br />rig c� <br />� <br />N <br />W <br />� <br />I TITLE SHEET I <br />EXISTING FLOOR <br />PLAN <br />- I HEREBY CERTIFY THAT I <br />HAVE REVIEWED THIS DESIGN <br />AND FOUND IT TO BE IN <br />COMPLIANCE WITH THE 7TH <br />EDITION (2020) OF THE F.B.C. <br />- THIS DRAWING IS VALID FOR <br />12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED. <br />�uuuuii <br />°��G �a����. <br />° <br />°o <br />0 <br />No. <br />i w STATE OF <br />"This Item has been digitally signed and <br />sealed by ANDRES C. HENAO on the date <br />adjacent to the seal. Printed copies of <br />this document ore not considered signed <br />and sealed and the signature must be <br />verified on any electronic copies' <br />JOB No: <br />HLH23-065 <br />DRAWN BY: <br />ACH <br />REVIEW BY: <br />DATE: <br />R318.1.8 <br />If a registered termiticide formulated and <br />used for subterranean <br />R318.1.1 through R318.1.6 do not apply. <br />registered <br />termite <br />Application <br />as a wood treatment is <br />prevention, Sections <br />of the wood treatment <br />11-02-2023 <br />SCALE: <br />SEE PLAN <br />termiticide shall <br />be as required by label <br />directions <br />for use, and must be <br />SHEET NUMBER <br />completed prior <br />to final building approval. <br />Al ■ <br />