5203
Location
17th St
Contractor
Kerns Family
Building Plans - Permit #
19911
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
" -T - v <br />31- O,1 S r- 410 <br />7 FIF-Q . E.Q. <br />REVISIONS <br />N01 DATE I DESCRIPTION <br />DESIGN AND WIND CRITERIA <br />(FBC 6th EDTION 2017 RESIDENTIAL) <br />Address: <br />5203 17th Street <br />Zephyrhills, Florida 33542 <br />Basic Wind Speed (V) <br />150 mph <br />Building Classification <br />RISK Category II <br />Wind Importance Factor (1) <br />1 <br />Wind Exposure <br />C <br />NOTE: <br />THIS BUILDING HAS BEEN DESIGNED TO RESIST WIND <br />INDUCED SHEAR AND UPLIFT FORCES, AS SPECIFIED TO <br />COMPLY WITH THE FLORIDA BUILDING CODE 6th EDITION <br />2017 RESIDENTIAL, SECTION R 301.2.(1) WITH A (3 <br />SECOND WIND GUST). <br />SECTION 101.1 <br />These regulations shall be known as the Florida <br />Building Code, Existing Building, hereinafter referred to <br />as "this code." In addition to the provisions of this <br />chapter, the provisions of Chapter 1, Florida Building <br />Code, Building, shall govern the administration and <br />enforcement of this code. <br />SECTION 101.2 <br />The provisions of the Florida Building Code, Existing <br />Building shall apply to the repair, alteration, change of <br />occupancy, addition to and relocation of existing <br />buildings. <br />SECTION $01 <br />Level 2 alterations as described in Section 504 shall <br />comply with the requirements of this chapter. The 2017 <br />Florida Building Code - Existing Building 6th Edition. <br />NOTE: <br />Proposed roof pitch: 6 / 12 Roof pitch "MUST" be approved by owner / and or <br />contractor before the production of any roof trusses. <br />Proposed 1 st f oor garage finish ceiling height: 9' - 4" (min.) Contractor "MUST" <br />coordinate and be approved by owner before construction begins. <br />Proposed 2nd floor garage apartment finish ceiling height: 8'- 4" (min.) Contractor <br />"MUST" coordinate and be approved by owner before construction begins. <br />All door and window header heights to start at: 6'- 8" Contractor "MUST" verify <br />"ALL" lintel height locations with owner before construction begins. <br />Truss company "MUST" field verify all existing conditions before engineering and <br />manufacturing of roof trusses. Daniel M. Ossman Drafting Service and Architect <br />who signed / sear the plans assumes no responsibility for errors in the roof truss <br />layout and dimensioning due to negligence to conduct proper and accurate field <br />inspection by truss manufacture. <br />CONTRACTOR, MUST COORDINATE WITH TRUSS MANUFACTURE FOR ALL VAULTED, TRAY, <br />FLAT AND OR OTHER CEILING TYPES. CONTRACTOR IS 100% RESPONSIBLE FOR THE <br />EXTERIOR WALL CONSTRUCTION METHOD `WHERE A GABLE END IS CONSTRUCTED. <br />ALL EXTERIOR AIALLS MUST COMPLY WITH THE FBC RESIDENTIAL CODE 6TH EDITION <br />(2017) RESIDENTIAL, CHAPTER 6, FOR WALL CONSTRUCTION METHODS. SEE ADDITIONAL <br />ATTACHED STRUCTURAL SHEETS FOR GABLE END BRACING DETAILS. DANIEL M. OSSMAN <br />DRAFTING SERVICE AND ARCHITECT WHO SIGNED 1 SEALED THE PLANS, ASSUMES NO <br />RESPONSIBILITY DUE TO NEGLIGENCE OF THE CONTRACTORS FAILURE TO FOLLOW <br />Window and Door Schedule <br />No. <br />Type <br />Size <br />Notes <br />Door or <br />Florida <br />Window <br />Product <br />Manufacturer <br />Aral # <br />Name <br />1 <br />Sectional Garage <br />7' x 9' <br />Overhead Door <br />FL 14170.10 R8 <br />Door <br />- <br />Corp <br />2 <br />Insulated exterior <br />36" x 80" <br />- <br />Thermo - Tru <br />FL 7640.1 R8 <br />door <br />corporation <br />3 <br />Single hung window <br />SH 22 <br />- <br />PGT kWusho- Inc. <br />FL 1435.5 R20 <br />4 <br />Sirsaft hung window <br />SH 24 <br />- <br />PGT kWusttries Mc. <br />FL 1435.5 R20 <br />5 <br />Single hung window <br />SH 25 <br />Fire egress single hung <br />PGT Industries Inc. <br />FL 1436.5 R20 <br />window <br />6 <br />Interior hollow core <br />30" x 80" <br />- <br />WA <br />WA <br />door <br />7 <br />Interior hollow core <br />36" x W' <br />- <br />NIA <br />N/A <br />bi4old door <br />New door and / or widow notes: <br />1. ALL EXTERIOR DOORS AND WINDOWS SPECIFIED ARE "IMPACT RESISTANT". <br />2. PROTECTION OF OPENINGS SHALL CONFORM AND MEET REQUIREMENTS AS SET <br />FORTH IN FBC 6th EDITION (2017) RESIDENTIAL, SECTION R 301.2.1.2 <br />3. Any products that are substituted, must meet or exceed products specified. Con&actor <br />"MUST" provide data to building inspector at time of inspection. <br />4. Contractor "MUST FIELD VERIFY" all existing openings specified on thin project, then <br />coordinate with manufacture before purchasing any doors and / or windows. Daniel M. Ossman <br />Drafting Service, Inc. "IS NOT" responsible for any errors in sizes, in the door / window schedule. <br />Between the garage and habitable area of the house <br />must have a fire separation constructed with 5/8" <br />type "X" drywall installed on both the garage wall <br />and ceiling. All doors from the habitable area to the <br />garage shall be a minimum thickness no less than <br />1 3/8" and be either solid wood or honeycomb steel <br />door with a 20-minute fire -rating. <br />All exterior masonry and / or frame perimeter walls <br />are to be considered shearwall segments, except at <br />door / window openings and wall lengths less than <br />2'- 8" in length. <br />First floor garage walls use 8" exterior concrete <br />block. <br />Second floor garage apartment "exterior walls" use <br />2 x 4 studs @ 16" o.c. and finish with 1/2" drywall <br />over min. R -13 insulation. For all "interior walls" use <br />2 x 4 studs @ 24" o.c. and finish with walls or any <br />other locations that are required by code. <br />N <br />r� <br />00 <br />0 <br />11 (D 1 11 11 (D'i <br />4'_ O"dImo' <br />19 l— O'' <br />2.4'-0" <br />LO <br />rb <br />SECOND FLOOR - PROPOSED FLOOR PLAN <br />Note: At all plumbing waNs use 2 x 6 studs to allow 9 <br />for ventilation plumbing stacks-.(� <br />Closet maid ventilated shelving. <br />ED <br />.19 <br />C' <br />24-1- O,, <br />24' - o " <br />SCALE: 1 /4" = 1' - 0" <br />FIRST FLOOR - PROPOSED FLOOR PLAN <br />�, <br />0 <br />It <br />N <br />SCALE: 114" = 1'- 0" <br />ci <br />a <br />pp T p�jp o <br />ea c7 'a W <br />A' e=e o = <br />a W, <br />or - <br />to <br />s. <br />•E w <br />a La a <br />a� <br />�L s <br />Nam~ <br />i p <br />M-o-v co <br />� ch LJJ V N <br />fl-c�s r10 <br />a�iM0CLffCOi <br />C 0 U Im M <br />c>a Cn ca o <br />2: L J U_ <br />cou-a <br />Ec'm°'v�E <br />� ass ca <br />U�rU32 cn <br />c� 3 0 E0 <br />L <br />1 <br />�E°'•�aCiv0 <br />r 0 C N <br />y O " 'a M <br />CO 0 �- > 00 <br />N.�!E c <br />t � t C 0 <br />UN n.=Na <br />N <br />U') <br />M <br />V) M <br />z v, <br />.0 0 <br />0 <br />LL <br />a. r*4%- vi <br />C� ce <br />Z O Q <br />Lid N <br />D <br />JOB NO. <br />5203 17TH STREET <br />DATE <br />APRIL 28, 2018 <br />DRAWN BY <br />Daniel M. Ossman <br />SHEET NO. <br />A-9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.