Jurisdiction Stainp
<br />L
<br />0
<br />w
<br />0
<br />0
<br />c
<br />T
<br />n
<br />O N
<br />ao
<br />N U
<br />L
<br />L U
<br />N N
<br />01
<br />O C
<br />U
<br />a
<br />U to
<br />7 C
<br />O
<br />0 a
<br />N
<br />0 N
<br />d
<br />3 c
<br />dM
<br />L
<br />c c'S
<br />3 0
<br />N j
<br />5
<br />O U
<br />.„
<br />�r
<br />oQ
<br />M
<br />� o
<br />a�
<br />N y
<br />U C
<br />a
<br />`o y
<br />N N
<br />C �
<br />0
<br />y t
<br />EE
<br />O O
<br />V U
<br />YN
<br />a
<br />m—
<br />h �
<br />E N
<br />o
<br />c� is
<br />m�
<br />o E
<br />m E
<br />m o
<br />c
<br />7Ui O
<br />M U
<br />m
<br />o .�
<br />� 3
<br />C to
<br />O U
<br />N �
<br />t5
<br />7
<br />O t
<br />ao
<br />Y `-
<br />`o c
<br />3-.0
<br />0 U
<br />N
<br />O
<br />N 0
<br />N U
<br />c c
<br />m a
<br />E
<br />E
<br />U L
<br />CQ
<br />m o
<br />U �
<br />� o
<br />U C
<br />�C
<br />-C O
<br />U
<br />a�
<br />T0)
<br />-a
<br />m aD
<br />0 0
<br />f0 Y
<br />3 �
<br />�C
<br />c�cv�
<br />C c
<br />C p
<br />U L)
<br />tai
<br />.ti
<br />U L
<br />O U
<br />t �
<br />VAULT CEILING ASSEMBLY:
<br />- STEEL JOIST FRAMING AS NECESSARY BY GC, 16 MSG,
<br />16" O/C;
<br />- SECURITY MESH W/ PROPRIETARY CLIPS TO JOISTS
<br />(SPEC BY TENANT), 16" O/C;
<br />- 3/4" T&G PLYWOOD;
<br />- 5/8' TYPE X GWB, FIRE -TAPED.
<br />NOTE:
<br />- FINAL HEIGHT TO BE SET BY OWNER.
<br />- SECURITY MESH TO BE LAPPED AND WIRE -TIED
<br />TO MESH IN WALL W/ #18 SWIG STEEL TIE WIRE, 16" O/C.
<br />- OWNER TO APPROVE LAYOUT OF SECURITY
<br />MESH PANELS.
<br />- VAULT WALL PARTITION SECURITY RATING TO BE
<br />SUBJECT TO REQUIRED SPECIFICATIONS OF EACH
<br />JURISDICTION. OWNER TO VERIFY REQUIREMENTS
<br />AND APPROVE ASSEMBLY.
<br />f
<br />CEILING TYPE 3: Vault Ceiling
<br />SCALE:3/4" = V-0"
<br />VAULT WALL:
<br />- 5/8" TYPE X GWB, FIRE -TAPED;
<br />- 2"x6" GALV. METAL STUDS, 16 MSG 16" O/C;
<br />- IN 2"x6" GALV. METAL TRACK (FLR & CLG);
<br />- 51/2" MINERAL WOOL SOUND ATT. BATTING;
<br />- 9 GAUGE EXPANDED METAL LATH;
<br />0
<br />112" PLYWOOD
<br />- 5/8" TYPE X GWB, FIRE -TAPED.
<br />NOTES:
<br />- FROM CONC. SLAB TO US DECK.
<br />- SET BOT. TRACK IN BUTYL SEALANT.
<br />- TENANT TO DETERMINE HEIGHT OF METAL LATH
<br />PAST CEILING HEIGHT.
<br />[�
<br />- TENANT TO APPROVE LAYOUT OF METAL LATH
<br />PANELS.
<br />- VAULT WALL PARTITION SECURITY RATING TO BE
<br />U
<br />SUBJECT TO REQUIRED SPECIFICATIONS OF EACH
<br />JURISDICTION. TENANT TO VERIFY REQUIREMENTS
<br />AND APPROVE ASSEMBLY.
<br />- NOMINAL STUD SIZES GIVEN, ACTUAL DIMENSIONS
<br />PER LOCAL AVAILABILITY.
<br />W3 WALL TYPE
<br />3: Vault Wall
<br />A002 SCALE:3/4" =
<br />V-0"
<br />W2
<br />A002
<br />SUSPENDED DRYWALL CEILING ASSEMBLY:
<br />- EX ROOF ASSEMBLY;
<br />- LIGHT GAUGE METAL HANGERS;
<br />- 2"X2" LIGHT GAUGE FRAMING, 20 MSG 16" O/C;
<br />- 2"X2" LIGHT GAUGE FRAMING, 20 MSG 16" O/C
<br />(OPPOSITE DIRECTION);
<br />- 5/8' TYPE X GWB, FIRE -TAPED.
<br />- PROVIDE 6" MINERAL WOOL SOUND ATT. INSUL.
<br />ABOVE ALL OFFICES, RESTROOMS, CONSULT.
<br />ROOMS, AND VAULTS. REFER TO SHEET NOTES.
<br />CEILING TYPE 2: Suspended Drywall Ceiling
<br />SCALE:3/4" = V-0"
<br />00
<br />CV',
<br />2"x 6" STUD PLUMBING PARTITION:
<br />- 5/8" TYPE X GWB, FIRE -TAPED;
<br />C}
<br />- 2"X6" GALV. METAL STUDS, 20 MSG 16" O/C;
<br />- IN 2"X6" GALV. METAL TRACK (FLR & TOP);
<br />- 51/2" MINERAL WOOL SOUND ATT. BATTING;
<br />- 5/8" TYPE X GWB, FIRE -TAPED.
<br />NOTES:
<br />- FROM CONC. SLAB TO MIN. 12" ABOVE ACT.
<br />-
<br />- BRACE TO STEEL JOISTS ABOVE AS
<br />NECESSARY.
<br />- NOMINAL STUD SIZES GIVEN, ACTUAL
<br />DIMENSIONS PER LOCAL AVAILABILITY.
<br />WALL TYPE 2: Plumbing Partition Wall
<br />SCALE:3/4" = 1'-0"
<br />35/ R' .
<br />- (2) NO. 10 WOOD
<br />SCREWS TO BOTTOM
<br />EACH EACH WOOD
<br />35/g, TRUSS; PROVIDE (1)
<br />AT EACH SIDE OF
<br />�EACH STUD, TYP.
<br />(4) NO. 10 TEK SCREW
<br />AT EACH STUD
<br />FLANGE TO TO
<br />FLANGE
<br />ALL STUDS TO BE MINIMUM OF 25 GA.
<br />STUDS SHALL BE SPACED AT 2'-0" O.C..
<br />PROVIDE VERTICAL SUPPORT AT 5'-0" MAX.
<br />DETAIL: Sofit Framing
<br />SCALE: 11/2"= V-0"
<br />TYPICAL DROP CEILING:
<br />NO. 10 TEK SCREW
<br />AT EACH STUD
<br />FLANGE TO TRACK,
<br />EACH SIDE OF METAL
<br />STUD, TYP.
<br />(4) NO. 10 TEK SCREW
<br />AT EACH STUD
<br />FLANGE TO TO
<br />FLANGE
<br />- EX ROOF ASSEMBLY;
<br />- LIGHT GAUGE METAL HANGERS;
<br />- 6" MINERAL WOOL SOUND ATT. BATT INSULATION:
<br />- T-BAR DROP CEILING W/ ACCOUSTIC
<br />CEILING TILES.
<br />- PROVIDE 6" MINERAL WOOL SOUND ATT. INSUL.
<br />ABOVE ALL OFFICES, RESTROOMS, CONSULT.
<br />ROOMS, AND VAULTS. REFER TO SHEET NOTES.
<br />CEILING TYPE 1: Typical Drop Ceiling
<br />SCALE:3/4" = V-0"
<br />NTERIOR PARTITION WALL:
<br />5/8 TYPE X GWB, FIRE -TAPED;
<br />11/2"x 35/8' GALV. METAL STUDS, 20 MSG 16" O/C;
<br />11/2"x 35/8' GALV. METAL TRACK (FLR & TOP);
<br />31/2" MINERAL WOOL SOUND ATT. BATTING;
<br />5/8" TYPE X GWB, FIRE -TAPED.
<br />N1 a OPTION:
<br />- 5/B" TYPE X GWB, FIRE -TAPED;
<br />11/2"x 35/8" GALV. METAL STUDS, 20 MSG 16" O/C;
<br />11/2"x 35/8" GALV. METAL TRACK (FLR & TOP);
<br />31/2" MINERAL WOOL SOUND ATT. BATTING;
<br />GWB ONLY ON ONE SIDE
<br />VOTES:
<br />FROM CONC. SLAB TO MIN. 12" ABOVE ACT.
<br />BRACE TO STEEL JOISTS ABOVE AS NECESSARY.
<br />-ACTUAL STUD DIMENSIONS PER LOCAL
<br />AVAILABILITY.
<br />WALL TYPE 1: Typical Interior Partition Wall
<br />SCALE:3/4" = V-0"
<br />WALL, FLOOR, AND CEILING TYPE NOTES:
<br />1. TENANT IS RESPONSIBLE FOR VERIFYING JURISDICTION
<br />SECURITY REQUIREMENTS FOR VAULT WALL, CEILING, AND
<br />FLOOR ENCLOSURE.
<br />2. VAULT WALL TYPE, VAULT CEILING ASSEMBLY, AND VAULT
<br />FLOOR ASSEMBLY BY ARCHITECT IS FOR PLANNING PURPOSES
<br />ONLY. TENANT IS RESPONSIBLE FOR APPROVING FINAL
<br />ASSEMBLY SPECIFICATION AND APPROVING SECURITY
<br />ASSEMBLY LAYOUT.
<br />3. DRAWINGS HEREIN BY ARCHITECT REFER TO SECURITY MESH
<br />ASSEMBLY FOR PRICING PURPOSES ONLY.
<br />4. SHOP DRAWING SUBMITTAL REQUIRED FOR ALL ASSEMBLIES,
<br />DOORS, ETC FOR VAULT. SHOP DRAWINGS TO BE APPROVED
<br />BY TENANT AND ARCHITECT.
<br />5. PROVIDE 6" MINERAL WOOL SOUND ATT. INSULATION ON TOP
<br />OF CEILING TILE ABOVE CONSULT ROOM, RESTROOMS,
<br />OFFICE, SURVEILLANCE, VAULT, AND ANY OTHER TENANT -
<br />DIRECTED SPACES. THESE SPACES ALSO REQUIRE WALLS TO
<br />THE UNDERSIDE OF DECK.
<br />client
<br />PLANTS OF RUSKIN LLC
<br />JOHN TIPTON
<br />PO BOX 126
<br />RUSKIN, FL 33575
<br />john.tipton@aitmed.com
<br />electrical engineer
<br />JEWITT ENGINEERING INC.
<br />623 BAYSIDE DR.
<br />FORT MEYERS, FL 33919
<br />239-432-1550
<br />hjewift@comr-ast.net
<br />mechanical / plumbing engineer
<br />KEVATRON ENGINEERING, INC.
<br />2324 CORAL POINT DRIVE
<br />CAPE CORAL, FL
<br />KEVIN ADAMS
<br />kevatron60@gmail.com
<br />239-242-7367
<br />drawing releases
<br />02 15 APR, 2022 ISSUED FOR PERMIT
<br />01 13 APR, 2022 ISSUED FOR CLIENT REVIEW
<br />issue date issued for
<br />architect
<br />collectiveoffice
<br />ARCHITECTURE
<br />INTERIORS
<br />DESIGN STRATEGY
<br />9 east 24th st., chicago, Illinois 60616
<br />1-312-818-2006 1 www.collectiveoffice.com
<br />I hereby certify that these plans were prepared under my direction
<br />and to the the best of my knowledge conform to the State and Local
<br />Building Codes and Ordinances.
<br />y SON . •
<br />,STERED Q'�G
<br />Project
<br />MUV - EPHYRHILLS, FL
<br />Location 5230 6TH ST
<br />ZEPHYR HILLS, FL
<br />Drawing Title
<br />WALL & FLOOR TYPES
<br />Drawing No. A002
<br />Issued For Job No.
<br />22013.0
<br />Date
<br />Permit 04-15-2022
<br />
|