Laserfiche WebLink
Jurisdiction Stainp <br />L <br />0 <br />w <br />0 <br />0 <br />c <br />T <br />n <br />O N <br />ao <br />N U <br />L <br />L U <br />N N <br />01 <br />O C <br />U <br />a <br />U to <br />7 C <br />O <br />0 a <br />N <br />0 N <br />d <br />3 c <br />dM <br />L <br />c c'S <br />3 0 <br />N j <br />5 <br />O U <br />.„ <br />�r <br />oQ <br />M <br />� o <br />a� <br />N y <br />U C <br />a <br />`o y <br />N N <br />C � <br />0 <br />y t <br />EE <br />O O <br />V U <br />YN <br />a <br />m— <br />h � <br />E N <br />o <br />c� is <br />m� <br />o E <br />m E <br />m o <br />c <br />7Ui O <br />M U <br />m <br />o .� <br />� 3 <br />C to <br />O U <br />N � <br />t5 <br />7 <br />O t <br />ao <br />Y `- <br />`o c <br />3-.0 <br />0 U <br />N <br />O <br />N 0 <br />N U <br />c c <br />m a <br />E <br />E <br />U L <br />CQ <br />m o <br />U � <br />� o <br />U C <br />�C <br />-C O <br />U <br />a� <br />T0) <br />-a <br />m aD <br />0 0 <br />f0 Y <br />3 � <br />�C <br />c�cv� <br />C c <br />C p <br />U L) <br />tai <br />.ti <br />U L <br />O U <br />t � <br />VAULT CEILING ASSEMBLY: <br />- STEEL JOIST FRAMING AS NECESSARY BY GC, 16 MSG, <br />16" O/C; <br />- SECURITY MESH W/ PROPRIETARY CLIPS TO JOISTS <br />(SPEC BY TENANT), 16" O/C; <br />- 3/4" T&G PLYWOOD; <br />- 5/8' TYPE X GWB, FIRE -TAPED. <br />NOTE: <br />- FINAL HEIGHT TO BE SET BY OWNER. <br />- SECURITY MESH TO BE LAPPED AND WIRE -TIED <br />TO MESH IN WALL W/ #18 SWIG STEEL TIE WIRE, 16" O/C. <br />- OWNER TO APPROVE LAYOUT OF SECURITY <br />MESH PANELS. <br />- VAULT WALL PARTITION SECURITY RATING TO BE <br />SUBJECT TO REQUIRED SPECIFICATIONS OF EACH <br />JURISDICTION. OWNER TO VERIFY REQUIREMENTS <br />AND APPROVE ASSEMBLY. <br />f <br />CEILING TYPE 3: Vault Ceiling <br />SCALE:3/4" = V-0" <br />VAULT WALL: <br />- 5/8" TYPE X GWB, FIRE -TAPED; <br />- 2"x6" GALV. METAL STUDS, 16 MSG 16" O/C; <br />- IN 2"x6" GALV. METAL TRACK (FLR & CLG); <br />- 51/2" MINERAL WOOL SOUND ATT. BATTING; <br />- 9 GAUGE EXPANDED METAL LATH; <br />0 <br />112" PLYWOOD <br />- 5/8" TYPE X GWB, FIRE -TAPED. <br />NOTES: <br />- FROM CONC. SLAB TO US DECK. <br />- SET BOT. TRACK IN BUTYL SEALANT. <br />- TENANT TO DETERMINE HEIGHT OF METAL LATH <br />PAST CEILING HEIGHT. <br />[� <br />- TENANT TO APPROVE LAYOUT OF METAL LATH <br />PANELS. <br />- VAULT WALL PARTITION SECURITY RATING TO BE <br />U <br />SUBJECT TO REQUIRED SPECIFICATIONS OF EACH <br />JURISDICTION. TENANT TO VERIFY REQUIREMENTS <br />AND APPROVE ASSEMBLY. <br />- NOMINAL STUD SIZES GIVEN, ACTUAL DIMENSIONS <br />PER LOCAL AVAILABILITY. <br />W3 WALL TYPE <br />3: Vault Wall <br />A002 SCALE:3/4" = <br />V-0" <br />W2 <br />A002 <br />SUSPENDED DRYWALL CEILING ASSEMBLY: <br />- EX ROOF ASSEMBLY; <br />- LIGHT GAUGE METAL HANGERS; <br />- 2"X2" LIGHT GAUGE FRAMING, 20 MSG 16" O/C; <br />- 2"X2" LIGHT GAUGE FRAMING, 20 MSG 16" O/C <br />(OPPOSITE DIRECTION); <br />- 5/8' TYPE X GWB, FIRE -TAPED. <br />- PROVIDE 6" MINERAL WOOL SOUND ATT. INSUL. <br />ABOVE ALL OFFICES, RESTROOMS, CONSULT. <br />ROOMS, AND VAULTS. REFER TO SHEET NOTES. <br />CEILING TYPE 2: Suspended Drywall Ceiling <br />SCALE:3/4" = V-0" <br />00 <br />CV', <br />2"x 6" STUD PLUMBING PARTITION: <br />- 5/8" TYPE X GWB, FIRE -TAPED; <br />C} <br />- 2"X6" GALV. METAL STUDS, 20 MSG 16" O/C; <br />- IN 2"X6" GALV. METAL TRACK (FLR & TOP); <br />- 51/2" MINERAL WOOL SOUND ATT. BATTING; <br />- 5/8" TYPE X GWB, FIRE -TAPED. <br />NOTES: <br />- FROM CONC. SLAB TO MIN. 12" ABOVE ACT. <br />- <br />- BRACE TO STEEL JOISTS ABOVE AS <br />NECESSARY. <br />- NOMINAL STUD SIZES GIVEN, ACTUAL <br />DIMENSIONS PER LOCAL AVAILABILITY. <br />WALL TYPE 2: Plumbing Partition Wall <br />SCALE:3/4" = 1'-0" <br />35/ R' . <br />- (2) NO. 10 WOOD <br />SCREWS TO BOTTOM <br />EACH EACH WOOD <br />35/g, TRUSS; PROVIDE (1) <br />AT EACH SIDE OF <br />�EACH STUD, TYP. <br />(4) NO. 10 TEK SCREW <br />AT EACH STUD <br />FLANGE TO TO <br />FLANGE <br />ALL STUDS TO BE MINIMUM OF 25 GA. <br />STUDS SHALL BE SPACED AT 2'-0" O.C.. <br />PROVIDE VERTICAL SUPPORT AT 5'-0" MAX. <br />DETAIL: Sofit Framing <br />SCALE: 11/2"= V-0" <br />TYPICAL DROP CEILING: <br />NO. 10 TEK SCREW <br />AT EACH STUD <br />FLANGE TO TRACK, <br />EACH SIDE OF METAL <br />STUD, TYP. <br />(4) NO. 10 TEK SCREW <br />AT EACH STUD <br />FLANGE TO TO <br />FLANGE <br />- EX ROOF ASSEMBLY; <br />- LIGHT GAUGE METAL HANGERS; <br />- 6" MINERAL WOOL SOUND ATT. BATT INSULATION: <br />- T-BAR DROP CEILING W/ ACCOUSTIC <br />CEILING TILES. <br />- PROVIDE 6" MINERAL WOOL SOUND ATT. INSUL. <br />ABOVE ALL OFFICES, RESTROOMS, CONSULT. <br />ROOMS, AND VAULTS. REFER TO SHEET NOTES. <br />CEILING TYPE 1: Typical Drop Ceiling <br />SCALE:3/4" = V-0" <br />NTERIOR PARTITION WALL: <br />5/8 TYPE X GWB, FIRE -TAPED; <br />11/2"x 35/8' GALV. METAL STUDS, 20 MSG 16" O/C; <br />11/2"x 35/8' GALV. METAL TRACK (FLR & TOP); <br />31/2" MINERAL WOOL SOUND ATT. BATTING; <br />5/8" TYPE X GWB, FIRE -TAPED. <br />N1 a OPTION: <br />- 5/B" TYPE X GWB, FIRE -TAPED; <br />11/2"x 35/8" GALV. METAL STUDS, 20 MSG 16" O/C; <br />11/2"x 35/8" GALV. METAL TRACK (FLR & TOP); <br />31/2" MINERAL WOOL SOUND ATT. BATTING; <br />GWB ONLY ON ONE SIDE <br />VOTES: <br />FROM CONC. SLAB TO MIN. 12" ABOVE ACT. <br />BRACE TO STEEL JOISTS ABOVE AS NECESSARY. <br />-ACTUAL STUD DIMENSIONS PER LOCAL <br />AVAILABILITY. <br />WALL TYPE 1: Typical Interior Partition Wall <br />SCALE:3/4" = V-0" <br />WALL, FLOOR, AND CEILING TYPE NOTES: <br />1. TENANT IS RESPONSIBLE FOR VERIFYING JURISDICTION <br />SECURITY REQUIREMENTS FOR VAULT WALL, CEILING, AND <br />FLOOR ENCLOSURE. <br />2. VAULT WALL TYPE, VAULT CEILING ASSEMBLY, AND VAULT <br />FLOOR ASSEMBLY BY ARCHITECT IS FOR PLANNING PURPOSES <br />ONLY. TENANT IS RESPONSIBLE FOR APPROVING FINAL <br />ASSEMBLY SPECIFICATION AND APPROVING SECURITY <br />ASSEMBLY LAYOUT. <br />3. DRAWINGS HEREIN BY ARCHITECT REFER TO SECURITY MESH <br />ASSEMBLY FOR PRICING PURPOSES ONLY. <br />4. SHOP DRAWING SUBMITTAL REQUIRED FOR ALL ASSEMBLIES, <br />DOORS, ETC FOR VAULT. SHOP DRAWINGS TO BE APPROVED <br />BY TENANT AND ARCHITECT. <br />5. PROVIDE 6" MINERAL WOOL SOUND ATT. INSULATION ON TOP <br />OF CEILING TILE ABOVE CONSULT ROOM, RESTROOMS, <br />OFFICE, SURVEILLANCE, VAULT, AND ANY OTHER TENANT - <br />DIRECTED SPACES. THESE SPACES ALSO REQUIRE WALLS TO <br />THE UNDERSIDE OF DECK. <br />client <br />PLANTS OF RUSKIN LLC <br />JOHN TIPTON <br />PO BOX 126 <br />RUSKIN, FL 33575 <br />john.tipton@aitmed.com <br />electrical engineer <br />JEWITT ENGINEERING INC. <br />623 BAYSIDE DR. <br />FORT MEYERS, FL 33919 <br />239-432-1550 <br />hjewift@comr-ast.net <br />mechanical / plumbing engineer <br />KEVATRON ENGINEERING, INC. <br />2324 CORAL POINT DRIVE <br />CAPE CORAL, FL <br />KEVIN ADAMS <br />kevatron60@gmail.com <br />239-242-7367 <br />drawing releases <br />02 15 APR, 2022 ISSUED FOR PERMIT <br />01 13 APR, 2022 ISSUED FOR CLIENT REVIEW <br />issue date issued for <br />architect <br />collectiveoffice <br />ARCHITECTURE <br />INTERIORS <br />DESIGN STRATEGY <br />9 east 24th st., chicago, Illinois 60616 <br />1-312-818-2006 1 www.collectiveoffice.com <br />I hereby certify that these plans were prepared under my direction <br />and to the the best of my knowledge conform to the State and Local <br />Building Codes and Ordinances. <br />y SON . • <br />,STERED Q'�G <br />Project <br />MUV - EPHYRHILLS, FL <br />Location 5230 6TH ST <br />ZEPHYR HILLS, FL <br />Drawing Title <br />WALL & FLOOR TYPES <br />Drawing No. A002 <br />Issued For Job No. <br />22013.0 <br />Date <br />Permit 04-15-2022 <br />